Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
800-227-4856
FAX 800-227-4866
Raychem
PolySwitch®
PTC Devices
Resettable Fuse
PRODUCT: AGR500S
DOCUMENT: SCD 24702
PCN: 767948-000
REV LETTER: A
REV DATE: FEBRUARY 6, 2001
PAGE NO.: 1 OF 2
Specification Status: RELEASED
Electrical Rating
Voltage: 16V MAX
Current: 100A MAX
INSULATING MATERIAL:
Cured, Flame Retarded Epoxy Polymer
meets UL94 V-0 Requirements
LEAD MATERIAL:
20 AWG Tin/Lead Plated Copper
(0.81mm [0.032] nom. diameter)
PART MARKING:
Raychem Logo
and Voltage
Lot Identification
(can be on back)
Part Identification
16
G 5
TABLE I. DIMENSIONS:
A B C D E F G
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX TYP MIN MAX
mm: 9.4 10.4 9.4 14.3 4.3 5.8 7.6 - 2.0 3.0 1.2 - 3.94
in*: (0.37) (0.41) (0.37) 0.56) (0.17) (0.23) (0.30) - (0.08) (0.12) (0.05) - (0.155)
*Rounded off approximation
TABLE II. PERFORMANCE RATINGS:
I HOLD CURRENT
RATINGS TIME TO
TRIP RESISTANCE TRIPPED-STATE
POWER
DISSIPATION
AMPS
25°C AMPS
AT 25°C SECONDS AT
25°C, 25 A OHMS
AT 25°C WATTS AT
25°C, 16V
OLD HOLD TRIP MAX MIN MAX TYP
5.00 5.00 8.50 2.0 0.015 0.034 2.6
Recognition: CSA / TUV / UL approved.
Reference Documents: PS300
Precedence: This specification takes precedence over documents referenced herein.
Effectivity: Reference documents shall be the issue in effect on the date of invitation for bid.
CAUTION: Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
800-227-4856
FAX 800-227-4866
Raychem
PolySwitch®
PTC Devices
Resettable Fuse
PRODUCT: AGR500S
DOCUMENT: SCD 24702
PCN: 767948-000
REV LETTER: A
REV DATE: FEBRUARY 6, 2001
PAGE NO.: 2 OF 2
TABLE III. AUTOMOTIVE SPECIFIC STRESS TESTS AND TEST CONDITIONS:
ELECTRICAL STRESS TESTS
TEST CONDITIONS (see note 2)
ESD Voltage Withstand
(see note 1) 25kV
Short Circuit Fault Current Durability 25 cycles, 16V, 200A
Fault Current Durability
350 cycles, 16V/100A
End-of-life Mode Verification
1750 cycles, 16V/100A
Jump Start Endurance
(see note 1) 3 cycles, 26V, 1 minute duration
Load Dump Endurance
(see note 1) 10 cycles, 86.5V
Note 1: The PolySwitch devices are tested in series with a load resistance and the voltages specified in the test conditions are
shared between the PolySwitch device and the load resistance as specified in PS400.
Note 2: Please refer to Appendix A of PS400 for the detailed test procedures