72 Series - Monitoring relays 16 A Features 72.01 72.11 Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator * Reinforced insulation (6 kV - 1.2/50 s) between: - supply and contacts - electrodes and supply - contacts and electrodes * 35 mm rail (EN 50022) mount * Control about a single level or between Min./Max. limits * 72.01 available also for supply 400 V * * * * * Sensitivity range (5...150) k adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable U = 24 V DC 24 V AC 50/60 Hz (110...125)V AC 50/60 Hz (230...240)V AC 50/60 Hz L/+ N/54.6 35 42.3 * * * Sensitivity fixed 150 k Delay time fixed: 1s Emptying or filling functions link selectable U = 24 V DC 24 V AC 50/60 Hz (110...125)V AC 50/60 Hz (230...240)V AC 50/60 Hz L/+ N/- FL FS FS ES A1 A2 EL 11 14 A1 B1 B2 A2 12 11 14 F = Filling Z1 Z2 LEVEL LEVEL 44.8 84 12 E = Emptying Z1 Z2 B3 B1 B2 B3 Z1 Z2 T=1s R = 150 k R = (5...150)k 58 FL = Filing - 7s delay FS = Filling - 0.5s delay ES = Emptying - 0.5s delay EL = Emptying - 7s delay FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE "General technical information" page V Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/Maximum switching voltage V AC Rated load AC1 1 CO (SPDT) 16/30 16/30 250/400 250/400 4,000 4,000 VA Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load 1 CO (SPDT) A VA 750 750 kW 0.55 0.55 16/0.3/0.12 16/0.3/0.12 500 (10/5) 500 (10/5) AgCdO AgCdO A mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) V AC Rated power AC/DC VA (50 Hz)/W 400 24 - 110...125 - 230...240 24 -- 24 2.5/1.5 2.5/1.5 2.5/1.5 AC (0.8...1.1)UN (0.9...1.15)UN (0.8...1.1)UN DC (0.8...1.1)UN -- (0.8...1.1)UN V DC Operating range 24 - 110...125 - 230...240 Technical data Electrical life at rated load AC1 cycles Electrode voltage V AC Electrode current mA Run-on time Max sensitivity range s k Insulation between supply/contacts/electrode (1.2/50 s) kV Ambient temperature Protection category C 100 * 103 100 * 103 4 4 0.2 0.2 0.5 - 7 (selectable) 1 5...150 (adjustable) 150 (fixed) 6 6 -20...+60 -20...+60 IP20 IP20 Approvals (according to type) 1 72 Series - Monitoring relays 6 A Features 72.31 3 Phase - Rotation and phase loss monitoring relay Universal voltage monitoring (UN from 208 V to 480 V, 50/60 Hz) * Phase loss monitoring, under phase regeneration * Positive safety logic - make contact opens if the relay detects an error * Small size (17.5 mm wide) * 35 mm rail (EN 50022) mount * European patent pending for the fully innovative principle at the root of the 3 phase monitoring and error survey system * * * Phase rotation monitoring Phase loss monitoring 56.5 43.5 26.5 UN= (208...480) V AC 3~ (50/60 Hz) L1 L2 L3 17.5 A2 A1 A3 45 84 A1 A2 A3 3~U 14 11 14 11 12 12 Contact specification 1 CO (SPDT) Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) 250/400 1,500 VA 250 kW 0.185 A 3/0.35/0.2 mW(V/mA) 500 (10/5) Breaking capacity DC1: 30/110/220 V Minimum switching load 6/15 AgCdO Standard contact material Supply specification Nominal system voltage (UN) Frequency Rated power Operating range V AC 3 ~ Hz VA 50 Hz/ W 208...480 50/60 8/1 V AC 3 ~ 170...500 cycles 100 * 103 s <0.5/<0.5 C -20...+50 Technical data Electrical life at rated load AC1 Switch-off/reaction time Ambient temperature Protection category Approvals (according to type) 2 IP20 72 Series - Monitoring relays 6 -16 A Ordering information Level control relays Example: 72 series level control relay, adjustable sensitivity range, (230...240)V AC supply voltage. 7 2 . 0 Series Type 0 = Sensitivity range adjustable (5...150)k 35 mm rail (EN 50022) mount 1 = Sensitivity fixed 150 k 35 mm rail (EN 50022) mount No. of poles 1 = 1 CO (SPDT) 1 . 8 . 2 4 0 . 0 0 0 0 Supply voltage 024 = 24 V 125 = (110...125)V AC 240 = (230...240)V AC 400 = 400 V AC (72.01 only) Supply version 8 = AC (50/60 Hz) 9 = DC Monitoring relays Example : 3 phase line monitoring relay, phase rotation and loss monitoring, supply voltage (208...480)V AC 3~. 7 2 . 3 Series Type 3 = 3 phase AC line monitoring No. of poles 1 = 1 CO 1 . 8 . 4 0 0 . 0 0 0 0 Supply voltage 400 = (208...480)V AC 3~ Supply version 8 = AC (50/60 Hz) 3 72 Series - Monitoring relays 6 - 16 A Technical data for 72.01 and 72.11 Insulation Insulation Dielectric strength Impulse (1.2/50 s) between supply and contacts 4,000 V AC 6 kV between electrodes, Z1-Z2 and supply* 4,000 V AC 6 kV between contacts and electrodes 4,000 V AC 6 kV between open contacts 1,000 V AC 1.5 kV EMC specifications Type of test Electrostatic discharge Reference standard contact discharge EN 61000-4-2 4 kV air discharge EN 61000-4-2 8 kV Radio-frequency electromagnetic field (80 / 1000 MHz) EN 61000-4-3 10 V/m Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV Surges (1.2/50 s) on Supply terminals EN 61000-4-5 4 kV Radio-frequency common mode (0.15 / 80 MHz) on Supply terminals EN 61000-4-6 10 V Radiated and conducted emission EN 55022 class B Other data Current absorption on Z1 and Z2 Power lost to the environment without contact current with rated current Screw torque mA <1 W 1.5 W 3.2 Nm 0.8 Max. wire size solid cable mm 2 AWG Max cable length between electrode and relay m stranded cable 1x6 / 2x4 1x4 / 2x2.5 1x10 / 2x12 1x12 / 2x14 200 (max. capacitance of 100 nF/km) * There is no electrical isolation between electrodes and supply voltage for the 24 V DC types (72.x1.9.024.0000). Therefore, for SELV applications it would be necessary to use a SELV (non-grounded) power supply. In the case of a PELV (grounded) power supply take care to protect the level control relay against harmful circulating currents by ensuring that no electrodes are grounded. However, there is no such problem for the 24 V AC types (72.x1.8.024.0000) which, by virtue of an internal isolating transformer, assure reinforced isolation between electrodes and supply. Technical data for 72.31 Insulation Insulation Dielectric strength Impulse (1.2/50 s) between supply and contacts 3,000 V 5 kV between open contacts 1,000 V 1.5 kV EMC specifications Type of test Electrostatic discharge Reference standard contact discharge EN 61000-4-2 4 kV air discharge EN 61000-4-2 8 kV Fast transients (burst) (5-50ns, 5kHz) on A1, A2, A3 EN 61000-4-4 2 kV Surge (1.2/50 s) EN 61000-4-5 4 kV differential mode Other data Start up time (NO contact closure after energising) s Regeneration level (Maximum) Power lost to the environment Screw torque without contact current W 1 with rated current W 1.4 Nm 0.8 Max. wire size solid cable mm 2 AWG 4 <2 80% of average of other 2 phase stranded cable 1x6 / 2x4 1x4 / 2x2.5 1x10 / 2x12 1x12 / 2x14 72 Series - Monitoring relays 16 A Functions for 72.01 and 72.11 U = Supply voltage B1 = Max level electrode B2 B3 Contacts Supply voltage NO output contact Open Closed = Min level electrode OFF Open 11 - 14 11 - 12 = Common ON Open 11 - 14 11 - 12 ON Open (Timing in Progress) 11 - 14 11 - 12 ON Closed 11 - 12 11 - 14 LED = Contact 11-14 Z1-Z2 = Link to select emptying (Type 72.11) Function and Run-on time Type 72.01 FL = Level control by Filling, Long (7sec) run-on delay. FS = Level control by Filling, Short (0.5sec) run-on delay. ES = Level control by Emptying, Short (0.5sec) run-on delay. EL = Level control by Emptying, Long (7sec) run-on delay. Type 72.11 F = Level control by Filling, Z1-Z2 open. Run-on time fixed at 1sec. E = Level control by Emptying, Z1-Z2 linked. Run-on time fixed at 1sec. Filling functions Wiring diagram Examples with 3 electrodes Type 72.01 U = 24 V DC 24 V AC 50/60 Hz (110...125)V AC 50/60 Hz (230...240)V AC 50/60 Hz L/+ N/- A1 A2 12 11 14 FS FL FS ES EL Filling Control - between Min. and Max. levels. Under normal operation the liquid level can be expected to cycle between the Minimum and the Maximum electrodes, B2 and B1 (plus a degree of over and under-shoot). U Level B1 B2 B3 LEVEL B1 B2 Switch On: * On "power-up", if the liquid is below B1 the output relay will operate after time T has expired. * On the liquid level falling below B2, the output relay will operate after time T has expired. B3 R = (5...150)k Type 72.11 L/+ N/- A1 A2 12 F = Filling 11 14 T Z1 Z2 T T T T LEVEL B1 B2 B3 Z1 Z2 T=1s R = 150 k Wiring diagram Examples with 2 electrodes Type 72.01 U = 24 V DC 24 V AC 50/60 Hz (110...125)V AC 50/60 Hz (230...240)V AC 50/60 Hz L/+ N/- FL A1 A2 12 11 14 FS FS ES Filling Control - about a single level, B1. Under normal operation the liquid evel can be expected to cycle about the level set by electrode B1 with a degree of over and under-shoot. U Level B1 B2 B3 EL Switch On: * On "power-up", if the liquid is below B1 the output relay will operate after time T has expired. * On the liquid level falling below B1, the output relay will operate after time T has expired. LEVEL B1 B2 B3 R = (5...150)k Type 72.11 L/+ N/- F = Filling A1 A2 12 11 14 Z1 Z2 LEVEL B1 B2 B3 Z1 Z2 Switch Off: * On the liquid level reaching electrode B1, the output relay will de-energise after time T has expired. * On "power-off", the output relay will immediately de-energise. T T T T T Switch Off: * On the liquid level reaching electrode B1, the output relay will de-energise after time T has expired. * On "power-off", the output relay will immediately de-energise. T=1s R = 150 k 5 72 Series - Monitoring relays 16 A Emptying functions Wiring diagram Examples with 3 electrodes Emptying Control - between Max. and Min. levels. Under normal operation the liquid level can be expected to cycle between the Maximum and the Minimum electrodes, B1 and B2 (plus a degree of over and under-shoot). Type 72.01 U = 24 V DC 24 V AC 50/60 Hz (110...125)V AC 50/60 Hz (230...240)V AC 50/60 Hz L/+ N/- A1 A2 12 U FL 11 14 EL FS ES Level EL B1 B2 B3 LEVEL B1 B2 Switch On: * On "power-up", if the liquid level is above B2 the output relay will operate after time T has expired. * On the liquid level rising to B1, the output relay will operate after time T has expired. B3 R = (5...150)k Type 72.11 L/+ N/- A1 A2 12 E = Emptying 11 14 Z1 Z2 T LEVEL T T T T B1 B2 B3 Z1 Z2 T=1s R = 150 k Wiring diagram Examples with 2 electrodes Type 72.01 L/+ N/- Emptying Control about a single level, B1. Under normal operation the liquid level can be expected to cycle about the level set by electrode B1 with a degree of over and under-shoot. U = 24 V DC 24 V AC 50/60 Hz (110...125)V AC 50/60 Hz (230...240)V AC 50/60 Hz A1 A2 12 Switch Off: * On the liquid level falling below electrode B2, the output relay will de-energise after time T has expired. * On "power-off", the output relay will immediately de-energise. FL 11 14 Level EL FS ES EL LEVEL Switch On: * On "power-up", if the liquid is above B1 the output relay will operate after time T has expired. * On the liquid level rising to B1, the output relay will operate after time T has expired. B1 B2 B3 R = (5...150)k Type 72.11 L/+ N/- A1 A2 12 11 14 Z1 Z2 Switch Off: * On the liquid level falling below electrode B1, the output relay will de-energise after time T has expired. * On "power-off", the output relay will immediately de-energ E = Emptying LEVEL B1 B2 B3 Z1 Z2 T=1s R = 150 k Applications for 72.01 and 72.11 FILLING function: Examples with 3 electrodes and with a contactor connected to the contact. L1 L2 L3 N L1 L2 L3 N A1 A2 B1 B2 B3 12 11 14 A1 A2 B1 B2 B3 Max Max Min Com The 72 series level control relays work by measuring the resistance through the liquid, between the common (B3) electrode and Min. and Max. electrodes (B2 and B1). If the tank is metalic, then this can be substituted as the B3 electrode. Take care to ensure that the liquid has a suitable resistivity - see below: S S 6 EMPTYING function: Examples with 3 electrodes and with a motor pump connected directly to the contact. Min Com 12 11 14 SUITABLE LIQUIDS - City water - Well water - Rainwater - Sea water - Liquids with low-percentage alcohol - Wine - Milk, Beer, Coffee - Sewage - Liquids fertilizer UN-SUITABLE LIQUIDS - Demineralised water - Fuels - Oil - Liquids with high-percentage alcohol - Liquid gas - Paraffins - Ethylene glycol - Paint 72 Series - Monitoring relays 6 A Functions for 72.31 L1, L2, L3 = Supply voltage Supply voltage LED status = Contact 11- 14 Supply voltage OFF OFF - Incorrect phase rotation - Phase loss ON Normal operation L1 UN= (208...480) V AC 3~ (50/60 Hz) L1 L2 L3 A1 A2 UN A3 L2 3~U L3 14 11 12 0.8 UN (*) ON NO output contact Contacts Closed Open Open 11 - 14 11 - 12 Closed 11 - 12 11 - 14 Switch off - Incorrect phase rotation - Phase loss Output contact (11 - 14) - Closed, if monitored system healthy (*) Phase loss monitoring possible under regeneration up to 80% of the average of the other 2 phases 11 - 14 7 72 Series - Monitoring relays Accessories for 72.01 and 72.11 Suspended electrode for conductive liquids, complete with cable. Suitable for level monitoring in wells and reservoirs not under pressure. All materials used are compatible with food processing applications (according to European Directive 2002/72 and cod. FDA title 21 part 177). Order appropriate number of electrodes - additional to the relay. 072.01.06 Cable length: 6 m (1.5 mm2) 072.01.06 Cable length: 15 m (1.5 mm2) 072.01.15 Technical data C +100 58 6m/15m Max. liquid temperature 23 Electrode holder with two pole connector, one connected directly to the electrode and the second connected to the grounded installation thread. Suitable for metal tank with G3/8" linkage. Electrode not incuded. Order appropriate number of electrodes holders - additional to the relay. 072.51 Technical data 072.51 Max liquid temperature C + 100 Max tank pressure bar 12 Cable grip mm O6 2 9 1 11 ch 22 10 G 3/8" 9 8 M4 M4 6 14 Electrode holder with three poles. Electrode not incuded. Order appropriate number of electrodes holders - additional to the relay. 072.53 Technical data Max liquid temperature 072.53 C 23 66 80 20 12 18 83 10 O5 91 25 2" GAS 8 M4 + 130 72 Series - Monitoring relays Accessories for 72.01 and 72.11 Electrode and electrode connector, multiple electrodes may be interconneced to provide required length Technical data Electrode - 500 mm long, M4 thread, stainless steel 072.500 Inter-electrode connector - M4 thread, stainless steel 072.501 072.500 Illustration of interconnection of electrodes. 072.501 9 72 Series - Monitoring relays Application notes for 72.01 and 72.11 Applications The main application for these relays is for the sensing and control of the level of conductive liquids. Selectable options allow for this control to be achieved either through a filling operation or through an emptying operation, and in either case "positive logic" is used. Level control can be achieved around a single level - using 2 electrodes, or between Minimum and Maximum levels - using 3 electrodes. Additionally, the 72.01, with its adjustable sensitivity setting, can be ideal for monitoring the conductivity of liquids. Positive safety logic These relays work according to the principle that it is the closure of a normally open output contact that will be used to control the pump, both in filling and emptying applications. Consequently, in the event of a failure of the supply local to the relay, the filling or emptying will cease. This is generally considered to be the safest option. Overrunning of tank on filling Care must be exercised to ensure that the tank cannot overrun. Factors that have to be considered are the pump performance, the rate of discharge from the tank, the position of the single level electrode (or maximum electrode), and the run-on time delay. Keeping the time delay to a minimum will minimise the possibility of tank overrun, but will increase the installed switching rate. Prevent dry running of pump on emptying Care must be exercised to ensure that the pump cannot run dry. Similar considerations must be given as outlined above. In particular, keeping the run-on time delay to a minimum will minimise the risk, but again, it will increase the installed switching rate. Run-on time In commercial and light industrial applications the use of a short Run-on time delay is more appropriate, due to the relatively small size of tanks and the consequential need to react quickly to the change in level. Larger scale industrial applications involving larger tanks and powerful pumps must avoid a frequent switching cycle, and the use of the 72.01 set for the longer Run-on time of 7 seconds is suggested. Note that the short run-on time will always achieve closer control to the desired level(s), but at the cost of more frequent switching. Electrical life of the output contact The electrical life of the output contact will be enhanced where a larger distance between the Max. and Min. electrodes (3-electrode control) can be realised. A smaller distance, or level control to a single level (2-electrode control), will result in more frequent switching and therefore a shorter electrical life for the contacts. Similarly, the long run-on time will enhance, and the short time will reduce, electrical life. Pump control Small single-phase pumps within the kW (0.55 kW - 230 V AC) rating stated may be driven directly by the level relay output contact. However, where very frequent switching is envisaged, it is better to "slave" a higher power relay or contactor to drive the pump motor. Large pumps (singlephase and three-phase) will of course require an interposing contactor. 10 Electrodes and cable lengths Normally 2 electrodes or 3 electrodes will be required for control about a single level, or control between Min. and Max. levels, respectively. However, if the tank is made of conductive material it is possible to use this as the common electrode, B3, if electrical connection can be made to it. The maximum permitted length of cable between the electrode and the relays is 200m, for a cable not exceeding 100nF/km. A maximum of 2 relays and associated electrodes can be employed in the same tank - if two different levels need monitoring. Note: It is permitted to make direct electrical connection between terminals B1-B3, and B2-B3, (without using electrodes/liquid), but in this case it is not possible to set up the sensitivity. Electrode choice The choice of electrodes may depend on the liquid being monitored. Standard electrodes 072.01.06 and 072.51 are suitable for many applications but some liquids may be corrosive for example, and may therefore require custom made electrodes - but these can usually be used with the 72.01 and 72.11 relays. On site commissioning To confirm the suitability of the relay sensitivity to the resistance between electrodes it is suggested that the following checks are made. For convenience it is suggested that the fill function and the shortest run-on time are selected. Commissioning Follow these setting-up instructions to achieve correct operation: 72.01 Select the function "FS" (Filling and Short delay of 0.5 s), and set the sensitivity control to 5 k. Ensure that all electrodes are immersed in the liquid - expect the output relay to be ON. Then, slowly rotate the sensitivity control in the 150 k direction until the level relay switches OFF (internal output relay will switch OFF and red LED will switch slowly flash). (If the level relay does not switch OFF then, either the electrodes are not immersed, or the liquid has too high impedance or the distance between electrodes is too long). Finally, select the filling or emptying function as required, run in real time and confirm that the level relay works as required. 72.11 Select the Filling function "F", (Z1 - Z2 open). Ensure that all electrodes are immersed in the liquid, but leave electrode B3 disconnected - output relay should be ON. Connect electrode B3, and the level relay should switch OFF (internal output relay will switch OFF and red LED will switch slowly flash). (If the level relay does not switch OFF then, either the electrodes are not immersed, or the liquid has too high impedance or the distance between electrodes is too long.) Finally, select the filling or emptying function as required, run in real time and confirm that the level relay works as required.