LOGIC CONTROLLER A Year 2000 compatible realtime calendar clock as standard on the whole range, with 350 programmable ON/OFF cycles! When setting the date, the day of the week is calibrated automatically, plus automatic changeover between winter/summer time! replace expensive programming clocks. 1 Part numbers Power Maximum consumption micro-cut 3 VA 4 VA 3W 3W 8 VA 6W 6W 10 ms 10 ms 5 ms 5 ms 10 ms 5 ms 5 ms Maximum inrush current Inputs / Outputs Power supply 0,7 A - 1,5 A 0,7 A - 1,5 A 7A 7A 0,7 A - 1,5 A 7A 7A 4E - 2S Relay 6E - 4S Relay 6E - 4S Relay 6E - 4S Solid state 12E - 8S Relay 12E - 8S Relay 12E - 8S Solid state 100-240 VAC + 10 % - 15 % 50/60 Hz 100-240 VAC + 10 % - 15 % 50/60 Hz 24 VDC + 20 % - 15 % 24 VDC + 20 % - 15 % 100-240 VAC + 10 % - 15 % 50/60 Hz 24 VDC + 20 % - 15 % 24 VDC + 20 % - 15 % 89 750 001 89 750 002 89 750 003 89 750 013 89 750 004 89 750 005 89 750 015 2 Accessories Millenium programming software - CD-ROM PC-module interface, length 3 m EEPROM memory module Faceplate for mounting on front panel MAS 6 - 10 Faceplate for mounting on front panel MAS 20 89 750 100 89 750 101 89 750 102 89 750 103 89 750 109 SOLID STATE OUTPUT CHARACTERISTICS AC INPUT CHARACTERISTICS Input voltage Input impedance Pull-in voltage at logic state 1 Drop-out voltage at logic state 0 Response time Status indicator 100-240 VAC + 10 %-15 %, 50-60 Hz > or = 800 kOhms Breaking voltage Breaking current 80 V Minimum load Max. inductive load Max. incandescent load Off-state leakage Response time Insulation Status indicator 40 V 50 ms YES on LCD screen DC INPUT CHARACTERISTICS Input voltage Input current Pull-in voltage at logic state 1 Drop-out voltage at logic state 0 Response time Status indicator Sensor type 24 VDC + 20 %-15 % 5 mA 18 V 4V 15 ms YES on LCD screen NPN or PNP 2 or 3-wire ELECTRICAL - ENVIRONMENTAL SPECIFICATIONS Insulation Safety class Earthing Protection Certifications Conformity with ANALOGUE INPUT CHARACTERISTICS MAS 10 MAS 20 Measurement range Resolution Conversion time Input voltage Input impedance Precision Temp. dependent derating 6 inputs from l01 to l06 8 inputs from l01 to l08 0-255 8 bits - 10 000 / 256 mV 10 ms 0-10 VDC 150 kOhms min. +/- 5 % (0.5 VDC) +/- 3 LSB Programming method Program size Program memory Removable memory Data memory Operating temperature Storage temperature Humidity RELAY OUTPUT CHARACTERISTICS Max. breaking voltage Breaking voltage Service life Minimum load Response time Status indicator 5 - 30 VDC 1 A / point (8 - 30 VDC), 0,1 A / point (5 - 8 VDC) 1 mA 1 A / 24 VDC (24 W) 0,125 A / 24 VDC (3 W) =<0,1 mA / 30 VDC =<1 ms Non YES on LCD screen 250 VAC - 30 VDC 8 A (10 A for 110 VAC outputs) 100,000 operations at 8 A / 240 VAC or 24 VDC 30,000 operations at 10 A / 110 VAC 50 mW (10 mA at 5 VDC) 10 ms YES on LCD screen Dimensions (l x h x d) To order, specify : Standard products 1 H Standard products, non stocked Part number 3 Accessory Example : Simple automation control modules - 89 750 001 - 89 750 100 1/65 7 MOhms at 500 VDC between connectors according to EN 60730-1 II None IP 20 CE, UL/cUL UL 508 EN 60730-1 EN 61010-1 EN 50081-1 EN 50082-1 EN 50082-2 Function blocks 64 function blocks or 1,500 bytes EEPROM built-in as standard YES - optional EEPROM cartridge Backed up for 20 days 0-55 C - 30 to + 70 C 35 - 85 % relative humidity without condensation 6-10 : 71.2 x 90 x 55 mm 20 : 124.6 x 90 x 55 mm 1 Connections PNP 100 - 240 VAC 50/60 Hz L N + + 500 mA - 500 mA + - (A) (B) 1 2 3 4 5 6 L N NCNC 1 2 3 4 5 6 Caution : Do not invert phase (L) and neutral (N) on the inputs 1 NPN OUT1 + 500 mA + or a + - (A) (B) 1 2 3 4 5 6 - 0V Dimensions 90 55 MAS 10 RCA 6/10 E/S : 71,2 20 E/S : 124,6 1/66 OUT2 OUT3 OUT4 -