BURNDY Compression TWO HOLE HYLUGTM FLEX CONDUCTOR LONG BARREL WITH INSPECTION WINDOW BEVELED ENTRY DIE AND COLOR CODE INFORMATION INSPECTION WINDOW CRIMPS TYPE YAZ-FX ELECTRO-TIN PLATED UL LISTED 90 C, 600 VOLT TO 35 KV CABLE ACCOMMODATION B C-77 B B 90 T T T 45 L L L Fig. 1 Fig. 2 Fig. 3 Conductor Catalog Number YAZ8C2TC10FX YAZ8C2TC10FX45 YAZ8C2TC10FX90 YAZ8C2TC10E2FX YAZ8C2TC10E2FX45 YAZ8C2TC10E2FX90 YAZ8C2TC14E1FX YAZ8C2TC14E1FX45 YAZ8C2TC14E1FX90 YAZ8C2TC14FX YAZ8C2TC14FX45 YAZ8C2TC14FX90 YAZ8C2TC14E2FX YAZ8C2TC14E2FX45 YAZ8C2TC14E2FX90 YAZ8C2TC38FX YAZ8C2TC38FX45 YAZ8C2TC38FX90 YAZV6C2TC10E2FX YAZV6C2TC10E2FX45 YAZV6C2TC10E2FX90 YAZV6C2TC14FX YAZV6C2TC14FX45 YAZV6C2TC14FX90 YAZV6C2TC14E2FX YAZV6C2TC14E2FX45 YAZV6C2TC14E2FX90 YAZV6C2TC14E1FX YAZV6C2TC14E1FX45 YAZV6C2TC14E1FX90 YAZV6C2TC38FX YAZV6C2TC38FX45 YAZV6C2TC38FX90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 37/24 #8 WELD Stud Stud Hole Hole Tongue Size Spacing Width # 10 5/8 .41 # 10 3/4 .41 1/4 1 .44 ** 10 #3 AWG 1/4 5/8 .44 1/4 3/4 .44 3/8 1 .58 # 10 3/4 .48 1/4 5/8 .48 1/4 3/4 .48 1/4 1 .48 3/8 1 .58 61/24 #6 WELD ** 16 #6 AWG Figure Dimensions (B) (T) (L) 2.20 .75 .08 2.09 1.37 2.33 .75 .08 2.22 1.50 2.70 .75 .08 2.60 1.87 2.32 .75 .08 2.20 1. 2.45 .75: .08 2.33 1.62 2.89 .75 .06 2.72 2.05 2.64 .75 .08 2.48 1.51 2.65 .75 .08 2.45 1.51 2.78 .75 .08 2.58 1.63 3.03 .75 .08 2.83 1.88 3.22 .75 .06 2.97 2.06 Dieless (# of crimps) Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length Y8MRB-1 (1) W8CVT (2) W8CVT (2) Y2MR (2) W8CRT (2)) W8CRT (2) MY29-11 (2) X8CRT (2) X8CRT (2) Y1MR (2) U8CRT (2) Red 49 1 Y2MR (2) W5CVT (2) W5CVT (2) MY29-11 (2) W5CRT (2) W5CRT (2) Y644M (1) X5CRT (2) X5CRT (2) Y1MR (2) U5CRT (2) Blue 7 1-3/16 * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** The MM2 conductor size referenced here is for both Class 2 and Class 5 conductor. *** The MM2 conductor size listed are the recommendations for Class 5 conductor. See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connecotrs. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 Catalog Number YAZV6C2TC38E2FX YAZV6C2TC38E2FX-45 YAZV6C2TC38E2FX-90 YAZV6C2TC38E6FX YAZV6C2TC38E6FX-45 YAZV6C2TC38E6FX-90 YAZV4C2TC38E2-FX YAZV4C2TC38E2-FX-45 YAZV4C2TC38E2-FX-90 YAZV4C2TC38FX YAZV4C2TC38FX45 YAZV4C2TC38FX90 YAZV4C2TC14FX YAZV4C2TC14FX45 YAZV4C2TC14FX90 YAZV4C2TC14E2FX YAZV4C2TC14E2FX45 YAZV4C2TC14E2FX90 YAZV2C2TC14FX YAZV2C2TC14FX45 YAZV2C2TC14FX90 YAZV2C2TC14E2FX YAZV2C2TC14E2FX45 YAZV2C2TC14E2FX90 YAZV2C2TC38FX YAZV2C2TC38FX45 YAZV2C2TC38FX90 YAZV2C2NTCFX YAZV2C2NTCFX45 YAZV2C2NTCFX90 YAZV1C2TC14FX YAZV1C2TC14FX45 YAZV1C2TC14FX90 YAZV1C2TC14E1FX YAZV1C2TC14E1FX45 YAZV1C2TC14E1FX90 YAZV1C2TC14E2FX YAZV1C2TC14E2FX45 YAZV1C2TC14E2FX90 YAZV1C2TC38FX YAZV1C2TC38FX45 YAZV1C2TC38FX90 YAZV1C2TC516E6FX YAZV1C2TC516E6FX-45 YAZV1C2TC516E6FX-90 YAZV1C2TC516FX YAZV1C2TC516FX45 YAZV1C2TC516FX90 Fig *** # AWG MM2 1 2 61/24 3 ** #6 WELD 1 16 #6 AWG 2 3 1 2 3 1 91/24-105/24 2 3 #4 WELD 1 2 #4 AWG 3 1 2 3 1 2 3 1 125/24-150/24 2 3 #2 WELD 35 1 2 #2 AWG 3 1 2 3 1 2 3 1 2 3 1 175/24-225/24 2 3 #1 WELD 1 2 #1 AWG 3 1 2 3 1 2 3 Stud Stud Hole Hole Tongue Size Spacing Width 3/8 3/4 .58 3/8 7/8 .58 3/8 3/4 .58 3/8 1 .58 1/4 5/8 .55 1/4 3/4 .55 1/4 5/8 .68 1/4 3/4 .68 3/8 1 .68 1/2 1-3/4 .83 1/4 5/8 .75 1/4 1 .75 1/4 3/4 .75 3/8 1 .75 5/16 7/8 .75 5/16 1 .75 L L L Fig. 1 Fig. 2 Figure Dimensions (B) (T) (L) 2.97 .75 .06 2.72 1.81 3.09 .75 .06 2.85 1.94 3.14 1.25 08 2.88 1.86 3.39 1.25 .08 3.13 2.11 2.83 1.25 .09 2.59 1.55 2.95 1.25 .09 2.72 1.68 3.01 1.38 .10 2.75 1.60 3.13 1.38 .10 2.87 1.73 3.57 1.38 .10 3.31 2.16 4.76 1.38 .10 4.50 3.35 3.04 1.38 .12 2.81 1.64 3.41 1.38 .12 3.18 2.01 3.16 1.38 .12 2.93 1.76 3.60 1.38 .12 3.37 2.20 3.35 1.38 .12 3.12 1.95 3.47 1.38 .12 3.24 2.08 Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length W5CVT (2) W5CRT (2) X5CRT (2) W5CVT (2) W5CRT (2) X5CRT (2) U5CRT (2) Blue 7 1-3/16 W4CVT (2) W4CRT (2) X4CRT (2) W4CVT (2) W4CRT (2) X4CRT (2) U4CRT (2) Gray 8 1-5/16 W2CVT (2) W2CRT (2) X2CRT (2) W2CVT (2) W2CRT (2) X2CRT (2) U2CRT (2) Brown 10 1-7/16 U1CRT-1 (2) Green 11 1-7/16 Conductor C-78 B B Dieless (# of crimps) Y1MR (2) Y2MR (2) MY29-11 (2) Y644M (1) Fig. 3 Y1MR (4) Y2MR (4) MY29-11 (2) Y644M (1) MY29-11 (2) Y644M (1) W1CVT (2) W1CVT (2) W1CRT-1 (2) W1CRT-1 (2) X1CRT-1 (2) X1CRT-1 (2) * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** The MM2 conductor size referenced here is for both Class 2 and Class 5 conductor. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connecotrs. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 L Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 275/24 1/0 WELD .83 1/4 3/4 .83 1 .83 1/2 1-3/4 .83 1/4 5/8 .93 1/4 3/4 .93 70 3/8 2/0 AWG 1 .93 1/2 1-3/4 .93 1/4 1.03 3/4 95 550/24 4/0 WELD 5/8 3/8 325/24 450/24 3/0 WELD 3/0 AWG 1/4 50 1/0 AWG 2/0 WELD Stud Stud Hole Hole Tongue Size Spacing Width ** 120 4/0 AWG 3/8 1 1.03 1/4 3/4 1.14 3/8 1 .94 3/8 1 1.14 1/2 1-3/4 1.14 550/24 4/0 WELD - 5/16 1-3/4 1.20 L L Fig. 1 Fig. 2 Figure Dimensions (B) (T) (L) 3.20 1.50 .12 2.92 1.66 3.32 1.50 .12 3.04 1.79 3.76 1.50 .12 3.48 2.23 4.95 1.50 .12 4.67 3.41 3.20 1.50 .13 2.92 1.66 3.32 1.50 .13 3.05 1.79 3.76 1.50 .13 3.48 2.23 4.95 1.50 .13 4.67 3.41 3.36 1.50 .14 3.08 1.82 3.80 1.50 .14 3.52 2.25 3.52 1.62 .15 3.23 1.86 3.96 1.62 .15 3.67 2.30 3.96 1.62 .15 3.67 2.30 4.93 1.62 .15 4.64 3.27 4.62 2.00 .16 4.35 2.96 Mechanical MD6, OUR840 MD7-34R Conductor Catalog Number YAZV252TC14FX YAZV252TC14FX45 YAZV252TC14FX90 YAZV252TC14E2FX YAZV252TC14E2FX45 YAZV252TC14E2FX90 YAZV252TC38FX YAZV252TC38FX45 YAZV252TC38FX90 YAZV252NTCFX YAZV252NTCFX45 YAZV252NTCFX90 YAZV262TC14FX YAZV262TC14FX45 YAZV262TC14FX90 YAZV262TC14E2FX YAZV262TC14E2FX45 YAZV262TC14E2FX90 YAZV262TC38FX YAZV262TC38FX45 YAZV262TC38FX90 YAZV262NTCFX YAZV262NTCFX45 YAZV262NTCFX90 YAZV272TC14E2FX YAZV272TC14E2FX-45 YAZV272TC14E2FX-90 YAZV272TC38FX YAZV272TC38FX45 YAZV272TC38FX90 YAZV282TC14E2FX YAZV282TC14E2FX45 YAZV282TC14E2FX90 YAZV282NT38FX YAZV282NT38FX-45 YAZV282NT38FX-90 YAZV282TC38FX YAZV282TC38FX45 YAZV282TC38FX90 YAZV282NTCFX YAZV282NTCFX45 YAZV282NTCFX90 YAZV292NT516FX YAZV292NT516FX-45 YAZV292NT516FX-90 B B Dieless (# of crimps) Fig. 3 Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length W25VT (4) W25VT (4) W25RT (4) W25RT (4) X25RT (4) X25RT (4) U25RT (2) Pink 12 1-9/16 W26VT (4) W26VT (4) W26RT (4) W26RT (4) X26RT (4) X26RT (4) U26RT (2) Black 13 1-9/16 W27VT (4) W27VT (4) W27RT (4) W27RT (4) X27RT (4) X27RT (4) U27RT (2) Orange 14 1-9/16 W28VT (4) W28VT (4) W28RT (4) W28RT (4) X28RT (6) X28RT (6) U28RT (2) Purple 15 1-11/16 W29RT (4) W29VT (4) X29RT (8) U29RT (2) Yellow MY29-11 (2) Y644M (1) Y644M (1) W29VT (4) X29RT (8) * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** The MM2 conductor size referenced here is for both Class 2 and Class 5 conductor. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connectors. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. 16 1-11/16 C-79 BURNDY Compression B TWO HOLE HYLUGTM FLEX CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 L Catalog Number YAZ302TC38FX YAZ302TC38FX-45 YAZ302TC38FX-90 YAZ312TC38FX YAZ312TC38FX45 YAZ312TC38FX90 YAZ312TC14E2FX YAZ312TC14E2FX-45 YAZ312TC14E2FX-90 YAZ322TC38FX YAZ322TC38FX45 YAZ322TC38FX90 YAZ342TC14E2FX YAZ342TC14E2FX-45 YAZ342TC14E2FX-90 YAZ342NT38FX YAZ342NT38FX-45 YAZ342NT38FX-90 YAZ342TC38FX YAZ342TC38FX45 YAZ342TC38FX90 YAZ342NTCFX YAZ342NTCFX45 YAZ342NTCFX90 YAZ362TC38FX YAZ362TC38FX45 YAZ362TC38FX90 YAZ382NT38FX YAZ382NT38FX-45 YAZ382NT38FX-90 YAZ382TC38FX YAZ382TC38FX45 YAZ382TC38FX90 YAZ382NNTFX YAZ382NNTFX-45 YAZ382NNTFX-90 YAZ382NTCFX YAZ382NTCFX45 YAZ382NTCFX90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 *** AWG MM2 250 FLEX CLASS G 259 STR. CLASS H 427 STR. 250 FLEX 637/24 150 CLASS I, K, M 775/24 185 313.1 kcmil 373.3 kcmil 925/24 Stud Stud Hole Hole Tongue Size Spacing Width 3/8 1 1.20 3/8 1 1.28 1/4 3/4 1.29 3/8 1 1.55 1/4 3/4 1.55 3/8 1 .96 240 3/8 (350 MCM NOM) 1 1.55 1/2 1-3/4 1.55 1100/24 444.4 kcmil - 535.3 kcmil 1325/24 (500 MCM NOM) 3/8 1 1.72 3/8 1 1.63 3/8 1 1.81 300 1/2 1-3/4 1.63 1/2 1-3/4 1.81 L L Fig. 1 Fig. 2 Figure Dimensions (B) (T) (L) 4.42 2.00 .16 4.05 2.37 4.45 2.00 .18 4.10 2.41 4.02 2.00 .18 3.66 1.97 4.62 2.12 .19 4.25 2.46 4.42 2.25 .23 4.06 2.10 4.85 2.25 .23 4.50 2.54 4.85 2.25 .23 4.50 2.54 6.04 2.25 .23 5.69 3.73 5.55 2.69 .27 5.14 2.81 5.72 2.81 .27 5.26 2.84 5.72 2.81 .27 5.26 2.84 6.72 2.81 .27 6.26 3.84 6.72 2.81 .27 6.26 3.84 Mechanical MD6, OUR840 MD7-34R Conductor C-80 B B Dieless (# of crimps) W29VT (4) X29RT (8) Fig. 3 Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length W29RT (4) W29VT (4) U29RT (2) Yellow 16 2-1/16 X29RT (8) W30VT (4) W30VT (4) W30RT (4) U30RT (4) White 17 2-1/16 W31VT (4) W31VT (4) W31RT (4) U31RT (4) Red 18 2-3/16 W32VT (4) W32VT (4) W32RT (4) U32RT (4) Blue 19 2-5/16 - - U34RT (4) Brown 20 - - U38XRT (4) Pink L99 2-7/8 Y644M (1) * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. *** The MM2 conductor sizes listed are the recommendations for Class 5 conductor. See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for "-FX" connecotrs. For nest/indentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. 2-3/4