DC/AC MicroProbe Model K110 (pdf) Rev. 04 02/08
Technical Assistance (800) 343-1391 www.aemc.com
1
of 4
DC/AC MicroProbe
Model K110
The Model K110 has exceptional AC/
DC current measurement capabilities.
Very small and compact, this micro-
probe is designed for accurate mea-
surement of very low currents with
50µAd c sensitivity.
Its very small size and “clip” shape
make it ideal for probing and measuring
in tight wiring areas such as circuit
boards, 4 to 20mA process loops or
automotive electronic circuitry. Model
K110 is an excellent companion to all
DMMs and instruments that will bene-
fit from the probe’s high sensitivity,
dynamic range and waveform displaying
characteristics.
The Model K110 provides higher
sensitivity and better accuracy with
an output of 10mV/mA. It provides
AC + DC output signal proportional to
the total current under test, without
the need of probe ranging or signal
filtering. True RMS measurements
with total AC + DC components are
possible.
Features
Measures extremely low level
DC from 100µA
Outputs signal proportional to total
current (AC + DC)
Low noise
Ultra-compact size and non-contact
clamp-on convenience
Simple plug-in operation
Designed for use with DMMs
and oscilloscopes
Accurate display of wave forms
No range or mode (AD/DC)
switching required
Extended battery life
Red LED indicates momentary or
continuous overload
Green LED indicates power and
battery condition
Double Insulation
CE Mark
Applications
Industrial process controls
(4 to 20mA current loops)
Electronic circuit design, testing
and repair
Automobile wiring and engine
control systems
Avionics systems maintenance
and repair
Shipboard maintenance and repair
Fault and signal location in complex
networks
Ground and leakage current
measurement
Pre-deployment testing of
power-conscious equipment
DC/AC MicroProbe Model K110 (pdf) Rev. 04 02/08
Technical Assistance (800) 343-1391 www.aemc.com
2
of 4
Specifications
MODELS K110
ELECTRICAL
Nominal Range 0 to 300mArms/0 to ±450mAd c
Measurement Range 0 to ±450mA
Output Signal 10mV/mA
Accuracy (450mA Range)
AC ±0.8% of Reading ± 200µA
DC ±0.5% of Reading ± 150µA
Overload Red LED indicates momentary or continuous overload
Frequency Range DC to 1.5kHz (@ -3dB sine)
Load Impedance 200
Working/Common
Mode Voltage 300V, EN 61010-1, Cat. II
Battery 9V Alkaline, NEDA 1604, 6LR61 or IEC 6 LF22
(Approx. 20 hours life)
Output Termination 4mm Safety Banana Plugs
MECHANICAL
Operating Temperature -14° to 131°F (-10° to 55°C)
Storage Temperature -40° to 176°F (-40° to 80°C)
Operating Relative
Humidity <95% @ 35°C, 75% @ 55°C
Zero Adjustment ±25mA approx. by 10 turn knob at base of case
Maximum Conductor Size 3/16", 0.180" (4.5mm)
Dimensions Probe: 4.4 x 0.6 x 1.0" (111 x 15 x 25mm); Electronic Module: 4.9 x 2.5 x 1.1" (124 x 64 x 28mm)
Weight 9 oz (250g)
SAFETY
Electrical EN 61010-2-32
Double Insulation Yes
CE Mark Yes
Note: Reference conditions: 23°C ±3°C, 20 to 75%RH, battery voltage 9V ±0.1V; earth’s magnetic field <40A/m; absence of AC fields;
input impedance of display device 1M/100pF; DC or sinusoidal AC current 45 to 65Hz.
DC/AC MicroProbe Model K110 (pdf) Rev. 04 02/08
Technical Assistance (800) 343-1391 www.aemc.com
3
of 4
ORDERING INFORMATION CATALOG NO.
AC/DC Microprobe Model K110 (Jack – 10mV/mA 450mA max) ............................... Cat. #2111.73
Includes a 9V battery and user manual
2.5"
(124mm)
1.0"
(25mm)
4.4"
(111mm)
4.9"
(124mm)
Ø=0.180" max.
(4.5mm)
Shrouded
Banana Plugs:
Two 4mm safety
banana plugs;
standard 3/4"
(19mm) spacing
DC/AC MicroProbe Model K110 (pdf) Rev. 04 02/08
Technical Assistance (800) 343-1391 www.aemc.com
4
of 4
Contact Us
United States & Canada:
Chauvin Arnoux®, Inc.
d.b.a. AEMC® Instruments
200 Foxborough Blvd.
Foxborough, MA 02035 USA
(508) 698-2115 Fax (508) 698-2118
www.aemc.com
Customer Support – for placing an order, obtaining price & delivery:
customerservice@aemc.com
Sales Department – for general sales information:
sales@aemc.com
Repair and Calibration Service – for information on repair & calibration, obtaining a user manual:
repair@aemc.com
Technical and Product Application Support – for technical and application support:
techinfo@aemc.com
Webmaster – for information regarding www.aemc.com:
webmaster@aemc.com
South America, Central America, Mexico, Caribbean, Australia & New Zealand:
Chauvin Arnoux®, Inc.
d.b.a. AEMC® Instruments
15 Faraday Drive
Dover, NH 03820 USA
(978) 526-7667 Fax (978) 526-7605
export@aemc.com
www.aemc.com
All other countries:
Chauvin Arnoux SCA
190, rue Championnet
75876 Paris Cedex 18, France
33 1 44 85 45 28 Fax 33 1 46 27 73 89
info@chauvin-arnoux.com
www.chauvin-arnoux.com