Features
1 of 8
Optimum Technology
Matching® Applied
GaAs HBT
InGaP HBT
GaAs MESFET
SiGe BiCMOS
Si BiCMOS
SiGe HBT
GaAs pHEMT
Si CMOS
Si BJT
GaN HEMT
RF MICRO DEVICES®, RFMD®, Optimum Technology Matching®, Enabling Wireless Connectivity™, PowerStar®, POLARIS™ TOTAL RADIO™ and UltimateBlue™ are trademarks of RFMD, LLC. BLUETOOTH is a trade-
mark owned by Bluetooth SIG, Inc., U.S.A. and licensed for use by RFMD. All other trade names, trademarks and registered trademarks are the property of their respective owners. ©2006, RF Micro Devices, Inc.
Product Description
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
RF MEMS
CGB-1089Z
50MHz to 1000MHz SINGLE ENDED
InGaP/GaAs HBT MMIC CATV AMPLIFIER
RFMD’s CGB-1089Z is a high performance InGaP HBT MMIC amplifier uti-
lizing a Darlington configuration with a 75Ω active bias network. The
active bias network provides stable current over temperature and process
Beta variations. Designed to run directly from a 5V supply, the CGB-1089Z
does not require a dropping resistor as compared to typical Darlington
amplifiers. The CGB-1089Z product is designed for high linearity 5V gain
block applications that require small size and minimal external compo-
nents. It is internally matched to 75Ω.
-5
0
5
10
10
12
14
16
18
L
oss dB
B
Gain & Return L o s s
db(S21)
db(S11)
-30
-25
-20
-15
-10
0
2
4
6
8
10
50 150 250 350 450 550 650 750 850 950
Return
L
Gain d
B
Frequency MHz
db(S22)
Flat Gain
Response:16dB±0.4dB
Excellent Return Loss:21dB
Low Distortion:-77/-65dBc
CTB/CSO
Single Fixed 5V Supply
Robust 1000V ESD, Class 1C
Applications
CATV Network Amplifiers
CATV Drop Amplifiers
Optical Rx/Tx
FTTH Video Solutions
EDS-104857 Rev D
9
9
CGB-1089Z
50Mhz to
1000MHz Sin-
gle Ended
InGaP/GaAs
HBT MMIC
CATV Amplifier
Parameter Specification Unit Condition
Min. Typ. Max.
Small Signal Gain 14.5 16.0 17.5 dB 500MHz
Output Power at 1dB Compression 16.5 18.0 dBm 500MHz
Third Order Intercept Point 35.0 dBm 500MHz
Second Order Intercept Point 50.0 dBm 500MHz
79Ch., Flat Tilt, 25dBmV, -65.0 dBc CSO
79Ch., Flat Tilt, 25dBmV -77.0 dBc CTB
79Ch., Flat Tilt, 25dBmV 76.0 dBc XMOD
Worst Case Input Return Loss 18.0 19 dB 50MHz to 1000MHz
Worst Case Output Return Loss 14 15 dB 50MHz to 1000MHz
Noise Figure 3.5 4.0 dB 500MHz
Reverse Isolation, 19.0 dB 50MHz to 1000MHz
Thermal Resistance 48.8 °C/W junction - lead
Device Operating Voltage 5.0 V
Device Operating Current 68.0 80.0 92.0 mA
Test Conditions: VD=5V, ID=80mA Typ., OIP3, OIP2 Tone Spacing=6MHz, POUT per tone=0dBm, TL=25°C, ZS=ZL=75Ω, Tested will App Circuit
2 of 8 EDS-104857 Rev D
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
CGB-1089Z
Typical RF Performance with Application Circuit at Key Operating Frequencies
Typical Unit Performance
Absolute Maximum Ratings
Parameter Rating Unit
Device Current (ID)110mA
Device Voltage (VD)5.5V
RF Input Power +12 dBm
Junction Temp (TJ)+150°C
Operating Temp Range (TL) -40 to +85 °C
Storage Temp +150 °C
Operating Dissipated Power 0.61 W
ESD Rating - Human Body Model
(HBM) Class 1A
Operation of this device beyond any one of these limits may cause permanent dam-
age. For reliable continuous operation, the device voltage and current must not
exceed the maximum operating values specified in the table on page one.
Bias Conditions should also satisfy the following expression:
IDVD<(T
J-TL)/RTH, j-l and TL=TLEAD
Parameter Unit 50
MHz
100
MHz
250
MHz
500
MHz
850
MHz
1000
MHz
Small Signal Gain (S21) dB 15.8 15.8 15.6 15.1 14.6 14.4
Output Third Order Intercept Point (OIP3) dBm 39.8 39.2 36.8 35.0 32.7 31.6
Output Second Intercept Point (OIP2) dBm 58.7 59.2 57.2 50.0 44.0 42.5
Output Power at 1dB Compression (P1dB) dBm 18.0 18.0 18.0 18.0 17.5 17.0
Input Return Loss (S11) dB 14.8 18.9 20.5 16.6 15.9 18.9
Output Return Loss (S22) dB 28.333.028.318.922.919.5
Reverse Isolation (S12) dB 19.019.019.019.019.019.0
Noise Figure (NF) dB 3.5 3.4 3.6 3.5 3.6 3.6
Test Conditions: VCC=5V ID=80mA Typ. OIP3, OIP2 Tone Spacing =6MHz, POUT per tone=0dBm
TL=25°C ZS=ZL=75Ω
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.
P1dB v s Frequency, Typ U ni t vs Temp
12
13
14
15
16
17
18
19
20
0 100 200 300 400 500 600 700 800 900 1000
Frequency(MHz)
P1dB(dBm)
-40C +25C +85C
OIP3 Vs Freq. Typ. Unit Pout/Tone = 0dBm, 6MHz Spacing
30
32
34
36
38
40
42
0 100 200 300 400 500 600 700 800 900 1000
Freq.(MHz)
OIP3(dBm)
-40C +25C +85C
3 of 8EDS-104857 Rev D
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
CGB-1089Z
Reverse Isolation vs Temp
-30
-25
-20
-15
-10
0 100 200 300 400 500 600 700 800 900 1000
Frequency (MHz)
S12 (dB)
-40C
25c
85C
Forwa rd Gain vs Temp
10
12
14
16
18
20
0 100 200 300 400 500 600 700 800 900 1000
Frequency (MHz)
S21 (dB)
-40C
25c
85C
Typical Unit S-Parameters vs Temperature. See page 5 for application circuit.
DC Current Supply vs Voltage, Typ Unit.
0
20
40
60
80
100
120
0123456
Voltage(V)
Idq(mA)
-40C +25C +85C
Noise Figure vs Freq, Typ Unit, Temp Data
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 200 400 600 800 1000
Freq(MHz)
NF(dB)
-40c +25c +85c
Typical Unit Performance. See page 5 for application circuit.
4 of 8 EDS-104857 Rev D
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
CGB-1089Z
yp
Vd=5V, Id=80mA, T=+25c, 79 Channel Plan, +25dBmV Flat Tilt Output
Composite Tri p le Beat v s F requency
Typ Unit, +25d BmV Flat, 79C h
70
72
74
76
78
80
82
84
86
88
90
0 100 200 300 400 500 600
Freq(MHz)
CTB(dBc)
-40C +25C +85C
Cross Modulation vs Frequency, Typ. Unit
+25dBmV Flat, 79Ch
0
20
40
60
80
100
120
140
0 100 200 300 400 500 600
Freq(MHz)
XMOD(dBc)
-40C +25C +85C
Composite Second Order(-) vs Fre quency
+25dBmV Flat Output, 79Ch
50
55
60
65
70
75
80
85
90
95
100
0 100 200 300 400 500 600
Freq(MHz)
CSO(dBc)
-40C +25C +85C
Composite Second Order(+) vs Frequency
+25dBmV Flat Output, 79Ch
50
55
60
65
70
75
80
85
90
95
100
0 100 200 300 400 500 600
Freq(MHz)
CSO(dBc)
-40C +25C +85C
5 of 8EDS-104857 Rev D
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
CGB-1089Z
Suggested PCB Pad Layout
Nominal Package Dimensions
Dimensions in inches (millimeters)
Refer to drawing posted at www.rfmd.com for tolerances.
Pin Function Description
1RF IN
RF input pin. This pin requires the use of an external DC blocking capacitor chosen for the frequency of operation.
2, 4 GND Connection to ground. Use via holes for best performance to reduce lead inductance as close to ground leads as possi-
ble.
3RF OUT/BIAS
RF output and bias pin. DC voltage is present on this pin, therefore a DC blocking capacitor is necessary for proper oper-
ation.
6 of 8 EDS-104857 Rev D
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
CGB-1089Z
Application Schematic
Reference
Designator
Frequency (MHz) 50 to 100
CB1/CB2 330pF
CB3 .5pF
LC1.2uH LS Coilcraft
LS6.8nH Toko
Vs
1uF 1200pF
Lc
Ls
Cb1 Cb2 Cb3
CGB-1089
RF in
75 RF out
75
41
23
7 of 8EDS-104857 Rev D
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
CGB-1089Z
Evaluation Board Layout and Bill of Materials
Mounting Instructions
1. Solder the copper pad on the backside of the device package to
the ground plane.
2. Use a large ground pad area with many plated through-holes as
shown.
3. We recommend 1 or 2 ounce copper. Measurement for this
datasheet were made on a 60 mil thick GTEK board with 1
ounce copper on both sides.
8 of 8 EDS-104857 Rev D
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
CGB-1089Z
Part Identification
Part will be symbolized with a “CB1Z” marking.
Ordering Information