Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/04/12 2
Switching Power Supply
Type SPD 30W
DIN rail mounting
Rated input voltage 100 - 240VAC
Voltage range
AC 85 - 264VAC
DC 90 - 375VDC
Rated input current
(Vi : 115VAC, Io nom) Typ. 560mA
Max. 800mA
Inrush current
Vi= 115VAC 20A
Vi= 230VAC 40A
Input Data
Power dissipation
(Vi : 230VAC, Io nom)
5V Model 8.5W
12V Model 5.6W
24V Model 5.5W
48V Model 4.9W
Frequency range 47- 63Hz
Leakage current
Input-Output 0.25mA
Input-FG 3.5mA
Overload 110 – 140%
Input fuse T2A/250VAC internal1)
Output short circuit Fold forward
Power ready output
(only SPD 24) On threshold ≥19.2-19.4VDC
Off threshold ≤19.1-19.3VDC
Controls and Protections
Over voltage protection VDC
Min. Max.
5V Model 66.8
12V Model 15 16.5
24V Model 30 33
48V Model 60 66
Internal surge voltage protection
Varistor
(IEC 61000-4-5)
1) Fuse not replaceable by user
Ambient temperature -40°C to 71°C
Derating (>61°C to +71°C) 2.5%/°C
Ambient humidity 20 ~ 90%RH
Storage -40°C to +85°C
Protection degree IP20
Cooling Free air convection
Pollution degree 2
General Data (@ nominal line, full load, 25°C )
MTBF (Bellcore issue 6 @ 40°C, GB)
5V Model 551000 Hours
12V Model 582000 Hours
24V Model 588000 Hours
48V Model 609000 Hours
Case material Plastic: PC, UL94-V0
Dimensions LxWxD mm(inch) 90(3.6) x 40.5(1.59) x 114(4.49)
Weight 270g
Vibration resistance meet IEC 60068-2-6
(Mounting by rail: 10-500Hz,
2G, along X, Y, Z each Axis,
60 min for each Axis)
Shock resistance meet IEC 60068-2-27
(15G, 11ms, 3 Axis, 6 faces,
3 times for each face)
UL / cUL UL508 listed, UL60950-1,
UL1310 Class 2 Power
(only 5V, w/o Class 2)
Recognized, ISA 12.12.01
(Class 1, Division 2,
Groups A, B, C and D)
TUV EN 60950-1, CB scheme
EN 61558-1,
EN 61558-2-17
(meet EN 60204)
CCC
GB4943, GB9254, GB17625.1
Norms and Standards
CE EN 61000-6-3, EN 55022
Class B, EN 61000-3-2,
EN 61000-3-3,
EN 61000-6-2,
EN 55024,
EN 61000-4-2 Level 4,
EN 61000-4-3 Level 3,
EN 61000-4-4 Level 4,
EN 61000-4-5 L-Level 3,
L/N-FG Level 4,
EN 61000-4-6 Level 3,
EN 61000-4-8 Level 4,
EN 61000-4-11,
ENV 50204 Level 2,
EN 61204-3