SPECIFICATIONS (1)
Input
Part Number C4OAC C4OACA C4OACR C4OACAR C4ODC C4ODCA
Nominal Voltage VDC 4-32 4-32 4-32 4-32 4-32 4-32
Minimum Voltage VDC 4.0 4.0 4.0 4.0 4.0 4.0
Maximum Voltage VDC 32 32 32 32 32 32
Drop-out Voltage 1.0 1.0 1.0 1.0 1.0 1.0
Maximum Current (2) (3) 22 22 22 22 16 16
Resistance Regulated Input Regulated Input Regulated Input Regulated Input Regulated Input Regulated Input
Output
Nominal Line Voltage 120 VAC 240 VAC 120 VAC 240 VAC 5-48 VDC 5-150 VDC
Minimum Line Voltage 12 VAC 12 VAC 12 VAC 12 VAC 5.0 VDC 3 VDC
Maximum Line Voltage 140 VAC 280 VAC 140 VAC 280 VAC 60 VDC 250 VDC
Max Off-State Voltage (4) 600 Vpeak 600 Vpeak 600 Vpeak 600 Vpeak 60 VDC 250 VDC
Max Off-State Leakage (5) 0.1mArms 0.1mArms 0.1mArms 0.1mArms 10 uA 10 uA
Static Off-State dv/dt (6) 200 V/usec 200 V/usec 200 V/usec 200 V/usec n/a n/a
Maximum Rated On-State Current (7) 3.0 Arms 3.0 Arms 3.0 Arms 3.0 Arms 3.0 A 1.0 A
Minimu m On -State Curre n t 50 mArm s 50 mArms 50 mArms 50 mArms 10 mA 10 mA
Max Surge Current (8) 100 Apeak 100 Apeak 100 Apeak 100 Apeak 5.0 Apeak 5.0 Apeak
On-State Voltage Drop or Resistance
(9) 1.6 V 1.6 V 1.6 V 1.6 V 1.6 V 1.6 V
HP Rating 1/4 1/4 1/4 1/4 n/a n/a
Maximum Turn-On Time [msec] (10) 8.33 8.33 0.1 0.1 0.05 0.05
Maximum Turn-Off Time [msec] 8.33 8.33 8.33 8.33 0.05 0.05
Input/Output Isolation Voltage (11) 4000 4000 4000 4000 4000 4000
Input/Output Capacitance 4 4 4 4 4 4
Operating Temperature Range -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C
Storage Temperature Range -40 to 100°C -40 to 100°C -40 to 100°C -40 to 100°C -40 to 100°C -40 to 100°C
Line Frequency Range 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz DC DC
Weight 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g)
General Notes:
(1) Specifications apply to an ambient temperature of -30 to 80 °C unless otherwise noted.
(2) At 32 VDC typical.
(3) 13 ma at 5 VDC for AC output modules only.
(4) Maximum 1 minute duration.
(5) At maximum rated line voltage, TA=80°C.
(6) Minimum DV/DT per EIA/NARM RS443, method RS397, DV/DT ratings do not apply to DC output models.
(7) Without any external heat sink in still air, TA=45°C, at 40°C derate 40 mA/°C to 80°C.
(8) At 25°C for 1 second maximum duration: 1 AC cycle for AC modules, 1 second for DC modules.
(9) At peak rated current.
(10) Before zero voltage, Vin=4V AC modules only based on 60Hz. Vin=15V for DC modules.
(11) For 1 second maximum duration TA= 25°C.
MECHANICAL SPECIFICATIONS
AGENCY APPROVALS
E46203 38595
Rev. 121311
ANNEX - ENVIROMENTAL INFORMATION
Solid State Relays I/O Modules