AUGUST 2003
NICKEL CADMIUM HANDBOOK, PAGE 59
P-500DR D size (KR33/62) Type: R
Dimensions (with tube) (mm)
Specifications
* 0.2It discharge capacity after charging at 0.1It for 16 hours.
** For reference only.
*** Refer to “Charge Methods for Ni-Cd Batteries”
Battery performance and cycle life are strongly affected by how they are
used. In order to maximize battery safety, please consult Panasonic when
determining charge / discharge specs, warning label contents and unit
design.
Typical Discharge Characteristics
Typical Charge Characteristics
NICKEL CADMIUM BATTERIES: INDIVIDUAL DATA SHEET
0 1 2 3 4 5 6 7 8
Discharge Time (hours)
Voltage (V)
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
1A(0.2It)
2.5A(0.5It)
Charge: 5000mA(1It)x 1.5hrs., 20˚C.
Discharge Temperature: 20˚C.
0 10 20 30 40 50 60 70 80 9
Discharge Time (minutes)
Voltage (V)
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
Charge: 5000mA(1It)x 1.5hrs., 20˚C.
Discharge Temperature: 20˚C.
5A(1It)
10A(2It)
1.3
1.2
1.1
1.0
0.90 20 40 60 80 100 12
Charge Time (minutes)
Voltage (V)
1.8
1.7
1.6
1.5
1.4
Charge: 5000mA(1It)x 1.5hrs.
10˚C
20˚C
40˚C
Charge: 500mA(0.1It)x 15hrs
1.3
1.2
1.1
1.0
0.90 2 4 6 8 10 12 14 16 1
Charge Time (hours)
Voltage (V)
1.8
1.7
1.6
1.5
1.4
0˚C
20˚C
45˚C
(+)
( )
61.0+
-0
1.
33.0+
-0
1.0
Note: [It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
• [It] is the reference test current in ampres
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
Diameter
Height
Approximate
Weight
mm inch
Grams Ounces
33.0 +0/-1.0
61.0 +0/-1.5 1.30 +0/-0.04
2.40 +0/-0.06
145g 5.10
Nominal V oltage 1.2V
5500mAh
5000mAh
5mΩ
Discharge
Capacity* Average**
Rated (Min.)
Approx. Internal impedance at
1000Hz at charged state
Charge
Charge
Storage
Discharge
Standard
Rapid***
Standard
Rapid
Ambient
Temperature
˚C ˚F
0˚C to 45˚C
10˚C to 45˚C
-20˚C to 65˚C
-20˚C to 35˚C
-20˚C to 45˚C
32˚F to 113˚F
50˚F to 113˚F
-4˚F to 149˚F
-4˚F to 95˚F
-4˚F to 113˚F
< 2 years
< 6 months
500mA (0.1It) x 16 hrs.
5000mA (0.33It) x 4.5 hrs.