4-144
FAST AND LS TTL DATA
MC54/74F280
FUNCTION TABLE
Number of HIGH Inputs Outputs
I0-I8∑ Even ∑ Odd
0, 2, 4, 6, 8 H L
1, 3, 5, 7, 9 L H
H = HIGH Voltage Level; L = LOW Voltage Level
GUARANTEED OPERATING RANGES
Symbol Parameter Min Typ Max Unit
VCC Supply Voltage 54, 74 4.5 5.0 5.5 V
74 0 25 70
IOH Output Current — High 54, 74 –1.0 mA
IOL Output Current — Low 54, 74 20 mA
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)
Limits
Symbol Parameter Min Typ Max Unit Test Conditions
VIH Input HIGH Voltage 2.0 V Guaranteed Input HIGH Voltage for All Inputs
VIL Input LOW Voltage 0.8 V Guaranteed Input LOW Voltage for All Inputs
VIK Input Clamp Diode Voltage –1.2 V VCC = MIN, IIN = –18 MA
VOH Output HIGH Voltage 54, 74 2.5 3.4 V IOH = –1.0 mA VCC = 4.5 V
74 2.7 3.4 V IOH = 1.0 mA VCC = 4.75 V
VOL Output Low Voltage 0.35 0.5 V IOL = 20 mA VCC = MIN
IIH Input HIGH Current 20 µA VCC = MAX, VIN = 2.7 V
100 µA VCC = MAX, VIN = 7.0 V
IIL Input LOW Current –0.6 mA VCC = MAX, VIN = 0.5 V
IOS Short Circuit Current (Note 2) –60 –150 mA VCC = MAX, VOUT = 0 V
ICC Power Supply Current 25 38 mA VCC = MAX
NOTES:
1. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions for the applicable device type.
2. Not more than one output should be shorted at a time, nor for more than 1 second.