A Series Miniature Control Units (06/11/10) A Series Miniature Control Units Series A6 Series Miniature Control Units Mounting Hole Size o16 Type AL6 AB6 AB6M-V AS6 AS6 (key) Appearance Unit * Illuminated Pushbuttons (Momentary, Maintained) * Pilot Light Bezel Size (Operator Size) o18 * Pushbuttons (Momentary, Maintained) 18 18 x 24 * Pushbuttons (Pushlock Turn Reset) * Selector Switch (90 2-position maintained, 90 2-position spring return, 45 3-position maintained, 45 3-position spring return) o18 o18 * Key Selector Switch (90 2-position maintained, 90 2-position spring return, 45 3-position maintained, 45 3-position spring return) 18 18 x 24 (o23.5) Black Light Source LED Lamp (IDEC's LATD Type) Lens/Button Color Lens: amber, blue, green, pure white, red, white, yellow Button: black, blue, green, red, white, yellow -- Button: red only -- Knob: black SPDT, DPDT (Gold-clad silver contact) Contact Rating (resistive load) 110V AC * 1A, 24V DC * 1A Electrical Momentary: 100,000 operations minimum Maintained: 50,000 operations minimum 100,000 operations minimum Mechanical Momentary: 1,000,000 operations minimum Maintained: 100,000 operations minimum 100,000 operations minimum Degree of Protection Enclosed type (IP40) Waterproof (IP65) Terminal Style Solder terminal Accessories -- Contact Configuration Durability Contact Bezel Color -- Key cylinder: chrome plating (metal) 250,000 operations minimum Switch Guard Yes Yes -- -- -- Socket Yes Yes Yes Yes Yes Terminal Cover Yes Yes Yes Yes Yes Dust Cover Yes Yes -- -- -- Mounting Hole Plug Yes Yes Yes Yes Yes Remarks * LED lamps contain * Available with threesided barrier. a current-limiting resistor and a protection diode. * Available with threesided barrier. * Operator position can be changed by IDEC's original bezel rotating and locking system. -- Approvals Page 2 5 8 9 10 11 (06/11/10) A Series Miniature Control Units Series A Series Miniature Control Units Mounting Hole Size Type o12 AL2 o10 AB2 AL1 o8 AB1 AL8 AB8 Appearance Unit Bezel Size (Operator Size) * Illuminated Pushbuttons (Momentary, Maintained) * Pilot Light o14 * Pushbuttons (Momentary, Maintained) 14 Bezel Color 14 x18 * Illuminated Pushbuttons (Momentary, Maintained) * Pilot Light o12 * Pushbuttons (Momentary, Maintained) Black Light Source LED lamp (IDEC's LAD-S) Lens/Button Color Lens: amber, green, red, white, yellow 12 x16 12 * Illuminated Pushbuttons (Momentary, Maintained) * Pilot Light o9 Black -- Button: black, blue, green, red, white, yellow LED lamp (IDEC's LAD-S) 9 x 12 9 Black -- Lens: amber, green, red, white, yellow * Pushbuttons (Momentary, Maintained) Button: black, blue, green, red, white, yellow LED lamp (IDEC's LAD-S) -- Lens: amber, green, red, white, yellow Button: black, blue, green, red, white, yellow SPDT, DPDT (silver contact) SPDT (silver contact) SPDT (silver contact) Contact Rating (resistor load) 110V AC * 1A, 24V DC * 1A 110V AC * 1A, 24V DC * 1A 110V AC * 1A, 24V DC * 1A Electrical Momentary: 100,000 operations minimum Maintained: 50,000 operations minimum Momentary: 100,000 operations minimum Maintained: 50,000 operations minimum Momentary: 100,000 operations minimum Maintained: 50,000 operations minimum Mechanical Momentary: 200,000 operations minimum Maintained: 100,000 operations minimum Momentary: 200,000 operations minimum Maintained: 100,000 operations minimum Momentary: 200,000 operations minimum Maintained: 100,000 operations minimum Enclosed type (IP40) Degree of Protection Waterproof (IP65) Oiltight Enclosed type (IP40) Enclosed type (IP40) Terminal Style Solder terminal Solder terminal Accessories Durability Contact Contact Configuration Solder terminal Switch Guard Yes Yes Yes Socket Yes Yes Yes Terminal Cover Yes Yes Yes Dust Cover Yes -- -- Mounting Hole Plug Yes Yes Yes * External current-limiting resistor type (Note) * External current-limiting resistor type (Note) * External current-limiting resistor type (Note) Remarks Approvals Page 25 26 32 33 38 39 Note: LED lamps do not have a current-limiting resistor, and external resistor must be provided. (06/11/10) 3 A6 Series Miniature Control Units o16 Light duty type in short 22mm body length. * Features IDEC's original mechanism for snap-action switching. Suitable for a wide variety of office and factory aplications. * The LED lamp contains a current-limiting resistor and a diode for protection against reverse connection. * 16-mm mounting holes * Available in enclosed (IP40) and waterproof (IP65), and oiltight types. * UL recognized, CSA certified, and EN compliant Contact Ratings (Contact Block) Rated Insulation Voltage 250V Rated Thermal Current 3A Operating Voltage (AC/DC) AC 50/60 Hz DC Specifications 12V 24V 110V 220V Resistive Load - - 1.0A 0.5A Inductive Load - - 0.7A 0.5A Resistive Load 1.0A 1.0A 0.2A - Inductive Load 0.7A 0.7A 0.5A - Contact Material Operating Temperature Storage Temperature Operating Humidity Contact Resistance Insulation Resistance Dielectric Strength Gold-clad silver Switch Unit * Minimum applicable load: 5V AC/DC, 1 mA (applicable range may vary with operating conditions and load types) Illumination Unit Weight Weight (approx.) Vibration Resistance AL6M-M24: 8g AL6M-P4: 6g AB6M-M2: 7g AB6M-V2R: 9g AS6M-2Y2: 9g Shock Resistance Mechanical Durability (minimum operations) AS6M-2KT2A: 21g Electrical Durability (minimum operations) Degree of Protection -25 to +55C (no freezing) -30 to +80 45 to 85% RH (no condensation) 50 m maximum (initial value) 100 M minimum (500V DC megger) Between live and dead metal parts: 2,000V AC, 1 minute Between terminals of different poles: 2,000V AC, 1 minute Between terminals of the same pole: 1,000V AC, 1 minute Between contact and lamp terminals: 1,500V AC, 1 minute Between live part and ground: 2,000V AC, 1 minute Operating extremes: 5 to 55 Hz, amplitude 0.75 mm Damage limits: 500 m/s2 (50G) Operating extremes: 200 m/s2 (20G) Momentary: 1,000,000 operations Maintained: 100,000 operations Pushlock Turn Reset: 100,000 operations Selector Switch: 250,000 operations Key Selector Switch: 250,000 operations Other than Maintained: 100,000 operations Maintained: 50,000 operations (Switching frequency 1200 operations/h) Enclosed (IP40) Waterproof, dust-tight (IP65) LED Lamp Ratings (LATD Type) LATD-5 Type No. LATD-1 LATD-2 Lamp Base Exclusive for A series control units Voltage Range 5V DC 5% 12V AC/DC 10% 24V AC/DC 10% Rated Voltage 5V DC 12V AC/DC 24V AC/DC Current Draw AC -- 9 mA 9 mA DC 8 mA 8 mA 8 mA Color Code A (amber), G (green), JW (pure white), R (red), S (blue), W (white), Y (yellow) Lamp Base Color Same as illumination color Voltage Marking Die stamped on the base Life (reference value) Approx. 50,000 hours (The luminance is reduced to 50% the initial intensity when used on complete DC.) (+) (-) Internal Circuit LED Chip Protection Diode Zener Diode * Specify a color code in place of in the Type No. A (amber), G (green), JW (pure white), R (red), S (blue), W (white), Y (yellow) 4 (06/11/10) A6 Series Miniature Control Units o16 AL6 LED Illuminated Pushbuttons Shape Operation Type Round AL6M Operating Voltage 5V DC 5% Momentary 12V AC/DC 10% 24V AC/DC 10% 5V DC 5% Maintained 12V AC/DC 10% Marking plate size: o13.7 mm Engraving area: o12 mm (Depth: 0.5 mm max.) 24V AC/DC 10% Square AL6Q 5V DC 5% Momentary 12V AC/DC 10% 24V AC/DC 10% 5V DC 5% Contact Type No. IP40 IP65 SPDT AL6M-M11 AL6M-M11P DPDT AL6M-M21 AL6M-M21P SPDT AL6M-M13 AL6M-M13P DPDT AL6M-M23 AL6M-M23P SPDT AL6M-M14 AL6M-M14P DPDT AL6M-M24 AL6M-M24P AL6M-A11P SPDT AL6M-A11 DPDT AL6M-A21 AL6M-A21P SPDT AL6M-A13 AL6M-A13P DPDT AL6M-A23 AL6M-A23P SPDT AL6M-A14 AL6M-A14P DPDT AL6M-A24 AL6M-A24P AL6Q-M11P SPDT AL6Q-M11 DPDT AL6Q-M21 AL6Q-M21P SPDT AL6Q-M13 AL6Q-M13P DPDT AL6Q-M23 AL6Q-M23P SPDT AL6Q-M14 AL6Q-M14P DPDT AL6Q-M24 AL6Q-M24P SPDT AL6Q-A11 AL6Q-A11P DPDT AL6Q-A21 AL6Q-A21P 12V AC/DC 10% SPDT AL6Q-A13 AL6Q-A13P Marking plate size: 13.7 mm Engraving area: 12 mm (Depth: 0.5 mm max.) DPDT AL6Q-A23 AL6Q-A23P 24V AC/DC 10% SPDT AL6Q-A14 AL6Q-A14P DPDT AL6Q-A24 AL6Q-A24P Rectangular AL6H 5V DC 5% Maintained Momentary 12V AC/DC 10% 24V AC/DC 10% 5V DC 5% Marking plate size: 13.7 x 19.7 mm Engraving area: 12 x 18 mm (Depth: 0.5 mm max.) Maintained 12V AC/DC 10% 24V AC/DC 10% Rectangular w/three-sided barrier AL6G 5V DC 5% Momentary 12V AC/DC 10% 24V AC/DC 10% 5V DC 5% Marking plate size: 13.7 x 19.7 mm Engraving area: 12 x 18 mm (Depth: 0.5 mm max.) Maintained 12V AC/DC 10% 24V AC/DC 10% SPDT AL6H-M11 AL6H-M11P DPDT AL6H-M21 AL6H-M21P SPDT AL6H-M13 AL6H-M13P DPDT AL6H-M23 AL6H-M23P SPDT AL6H-M14 AL6H-M14P DPDT AL6H-M24 AL6H-M24P SPDT AL6H-A11 AL6H-A11P DPDT AL6H-A21 AL6H-A21P SPDT AL6H-A13 AL6H-A13P DPDT AL6H-A23 AL6H-A23P SPDT AL6H-A14 AL6H-A14P DPDT AL6H-A24 AL6H-A24P AL6G-M11P SPDT AL6G-M11 DPDT AL6G-M21 AL6G-M21P SPDT AL6G-M13 AL6G-M13P DPDT AL6G-M23 AL6G-M23P SPDT AL6G-M14 AL6G-M14P DPDT AL6G-M24 AL6G-M24P SPDT AL6G-A11 AL6G-A11P DPDT AL6G-A21 AL6G-A21P SPDT AL6G-A13 AL6G-A13P DPDT AL6G-A23 AL6G-A23P SPDT AL6G-A14 AL6G-A14P DPDT AL6G-A24 AL6G-A24P Lens Color Code Specify a color code in place of in the Type No. A: amber G: green JW: pure white R: red S: blue W: white Y: yellow * See page 7 for dimensions. (06/11/10) 5 o16 A6 Series Miniature Control Units AL6 LED Illuminated Pilot Lights Shape Round AL6M-P Marking plate size: o13.7 mm Engraving area: o12 mm (Depth: 0.5 mm max.) Square AL6Q-P Marking plate size: 13.7 mm Engraving area: 12 mm (Depth: 0.5 mm max.) Rectangular AL6H-P Marking plate size: 13.7 x 19.7 mm Engraving area: 12 x 18 mm (Depth: 0.5 mm max.) Rectangular w/three-sided barrier AL6-GP Marking plate size: 13.7 x 19.7 mm Engraving area: 12 x 18 mm (Depth: 0.5 mm max.) Operating Voltage Type No. IP40 IP65 5V DC 5% AL6M-P1 AL6M-P1P 12V AC/DC 10% AL6M-P3 AL6M-P3P 24V AC/DC 10% AL6M-P4 AL6M-P4P 5V DC 5% AL6Q-P1 AL6Q-P1P 12V AC/DC 10% AL6Q-P3 AL6Q-P3P 24V AC/DC 10% AL6Q-P4 AL6Q-P4P 5V DC 5% AL6H-P1 AL6H-P1P 12V AC/DC 10% AL6H-P3 AL6H-P3P 24V AC/DC 10% AL6H-P4 AL6H-P4P 5V DC 5% AL6G-P1 AL6G-P1P 12V AC9DC 10% AL6G-P3 AL6G-P3P 24V AC/DC 10% AL6G-P4 AL6G-P4P Lens Color Code Specify a color code in place of in the Type No. A: amber G: green JW: pure white R: red S: blue W: white Y: yellow * See page 7 for dimensions. 6 (06/11/10) A6 Series Miniature Control Units o16 Dimensions (Illuminated Pushbuttons & Pilot Lights) Terminal Width 2.8x0.5t 3 Panel Thickness 0.5 to 6 Rectangular Rectangular w/3-way barrier (TOP) Locking Ring Round Square (TOP) o18 (TOP) 5 18 5 2.5 Rubber Gasket Anti-rotation Ring 6 1 6 8 Pilot Light 0.6 22 5.7 c18 24 9 9 Illuminated Pushbutton Terminal Arrangement (bottom view) Illuminated Pushbutton Pilot Light (TOP) (TOP) NC1 NC2 NO1 NO2 C1 Lamp Terminal (+) C2 Lamp Terminal (-) Lamp Terminal (+) Lamp Terminal (-) Mounting Hole Layout Round/Square +0.2 0 o16.2 +0.2 0 Note: Determine mounting centers to ensure easy operation. 18 min. 18 min. 16.2 Rectangular Rectangular w/3-way barrier 18 min. 24 min. All dimensions in mm. (06/11/10) 7 o16 A6 Series Miniature Control Units AB6 Pushbuttons Shape Operation Type Button Type Round AB6M Contact Momentary Button Maintained Momentary Illumination Lens Maintained Square AB6Q Momentary Button Maintained Momentary Illumination Lens Maintained Rectangular AB6H Momentary Button Maintained Momentary Illumination Lens Maintained Rectangular w/three-sided barrier AB6G Momentary Button Maintained Momentary Illumination Lens Maintained Type No. SPDT IP40 AB6M-M1 IP65 AB6M-M1P DPDT AB6M-M2 AB6M-M2P SPDT AB6M-A1 AB6M-A1P DPDT AB6M-A2 AB6M-A2P SPDT AB6M-M1L AB6M-M1PL DPDT AB6M-M2L AB6M-M2PL SPDT AB6M-A1L AB6M-A1PL DPDT AB6M-A2L AB6M-A2PL SPDT AB6Q-M1 AB6Q-M1P DPDT AB6Q-M2 AB6Q-M2P SPDT AB6Q-A1 AB6Q-A1P DPDT AB6Q-A2 AB6Q-A2P SPDT AB6Q-M1L AB6Q-M1PL DPDT AB6Q-M2L AB6Q-M2PL SPDT AB6Q-A1L AB6Q-A1PL DPDT AB6Q-A2L AB6Q-A2PL SPDT AB6H-M1 AB6H-M1P DPDT AB6H-M2 AB6H-M2P SPDT AB6H-A1 AB6H-A1P DPDT AB6H-A2 AB6H-A2P SPDT AB6H-M1L AB6H-M1PL DPDT AB6H-M2L AB6H-M2PL SPDT AB6H-A1L AB6H-A1PL DPDT AB6H-A2L AB6H-A2PL SPDT AB6G-M1 AB6G-M1P DPDT AB6G-M2 AB6G-M2P SPDT AB6G-A1 AB6G-A1P DPDT AB6G-A2 AB6G-A2P SPDT AB6G-M1L AB6G-M1PL DPDT AB6G-M2L AB6G-M2PL SPDT AB6G-A1L AB6G-A1PL DPDT AB6G-A2L AB6G-A2PL Color Code B G: R: S: W: Y: A: G: R: S: W: Y: B G: R: S: W: Y: A: G: R: S: W: Y: B G: R: S: W: Y: A: G: R: S: W: Y: B G: R: S: W: Y: A: G: R: S: W: Y: black green red blue white yellow amber green red blue white yellow black green red blue white yellow amber green red blue white yellow black green red blue white yellow amber green red blue white yellow black green red blue white yellow amber green red blue white yellow * Specify a color code in place of or in the Type No. Dimensions Rubber Gasket Terminal Width 2.8x0.5t Anti-rotation Ring 2.5 3 Locking Ring Panel Thickness 0.5 to 6 Rectangular Rectangular w/3-way barrier (TOP) Square (TOP) o18 Round (TOP) 5 18 5 (Pushbutton) 1 8 0.6 9 22 24 9 Mounting Hole Layout +0.2 0 Terminal Arrangement * Rectangular * Rectangular w/3-way barrier o16.2 +0.2 0 (bottom view) * Pushbutton (TOP) Note: Determine mounting centers to ensure easy operation. 18 min. o16.2 18 min. * Round/Square 5.7 18 NC1 NC2 NO1 NO2 C1 18 min. 8 C2 24 min. All dimensions in mm. (06/11/10) A6 Series Miniature Control Units o16 AB6M-V Pushbuttons (Pushlock Turn Reset) Shape Operation Type Type No. Contact IP40 IP65 Button Color Code AB6M-V SPDT AB6M-V1R AB6M-V1PR Pushlock Turn Reset R: red only DPDT AB6M-V2R AB6M-V2PR * Do not use the AB6M-V pushbuttons as emergency stop switches. For the application of emergency stop switch, use the XA or H6 series switches (ISO 13850, IEC 60947-5-5 compliant). Dimensions (Pushlock Turn Reset Pushbutton) Rubber Gasket Terminal Width 2.8x0.5t Anti-rotation Ring 2.5 3 Locking Ring 5 5 o23.5 Panel Thickness 0.5 to 6 1 8 0.6 22 9.5 15.5 Terminal Arrangement (bottom view) Mounting Hole Layout (Pushbutton) * w/Mushroom Button (Pushlock Turn Reset) (TOP) NC1 NC2 o16.2 +0.2 0 NO1 NO2 C1 C2 SPDT has NC1, NO1, and C1 only. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. (06/11/10) 9 o16 A6 Series Miniature Control Units AS6 Selector Switches Operator position can be changed by IDEC's original bezel rotating and locking system. The bezel can be locked at every 45 and bezel rotation is prevented while mounting on a panel. * How to change the operator position 3-position Types R R L (C) (C) (C) R L (C) Pull out the bezel to release the lock. Rotate the bezel, and push it in at 45 intervals to lock the bezel. R L L Normal Operator Position 45 3-position Rectangular AS6H- Y 90 2-position 45 3-position 90 2-position Square AS6Q- Y SPDT DPDT SPDT DPDT DPDT Type No. IP40 IP65 AS6M-2Y1 AS6M-2Y1P AS6M-2Y2 AS6M-2Y2P AS6M-21Y1 AS6M-21Y1P AS6M-21Y2 AS6M-21Y2P AS6M-3Y2 AS6M-3Y2P DPDT AS6M-31Y2 AS6M-31Y2P Contact Maintained Spring return from right to left Maintained Spring return from right to center Spring return from left to center Spring return two-way Maintained Spring return from right to left Maintained Spring return from right to center Spring return from left to center Spring return two-way DPDT AS6M-32Y2 AS6M-32Y2P DPDT SPDT DPDT SPDT DPDT DPDT AS6M-33Y2 AS6Q-2Y1 AS6Q-2Y2 AS6Q-21Y1 AS6Q-21Y2 AS6Q-3Y2 DPDT AS6Q-31Y2 AS6Q-31Y2P DPDT AS6Q-32Y2 AS6Q-32Y2P DPDT SPDT DPDT SPDT DPDT DPDT AS6Q-33Y2 AS6H-2Y1 AS6H-2Y2 AS6H-21Y1 AS6H-21Y2 AS6H-3Y2 AS6Q-33Y2P AS6H-2Y1P AS6H-2Y2P AS6H-21Y1P AS6H-21Y2P AS6H-3Y2P DPDT AS6H-31Y2 AS6H-31Y2P DPDT AS6H-32Y2 AS6H-32Y2P DPDT AS6H-33Y2 AS6H-33Y2P Contact Operation Position Operation Type Spring return from right to left Maintained Spring return from right to center Spring return from left to center Spring return two-way Right Center AS6M-33Y2P AS6Q-2Y1P AS6Q-2Y2P AS6Q-21Y1P AS6Q-21Y2P AS6Q-3Y2P R NO NC NO NC -- Maintained C C DPDT L R L C Left Right Contact Contact NO NC NO NC Left Right Contact Contact NO NC NO NC Spring return from right C -- C C C DPDT R Maintained L Maintained Left SPDT L 90 2-position 45 3-position 90 2-position Round AS6M- Y Position 45 3-position Shape C R Spring return from right L C C Left Right Contact Contact NO NC NO NC Left Right Contact Contact NO NC NO NC R Spring return from left L Left Right Contact Contact NO NC NO NC C C C C C C R Two-way return * Knob: black * Bezel: black Dimensions Terminal Width 2.8x0.5t 2.5 3 Rubber Gasket Anti-rotation Ring Panel Thickness 0.5 to 6 Rectangular (TOP) Locking Ring Square (TOP) Round (TOP) 8 5 18 5 o1 8 1 8 22 15.5 c18 24 Terminal Arrangement (bottom view) Mounting Hole Layout (Selector Switch) * Round/Square o16.2 +0.2 0 * Rectangular o16.2 +0.2 0 (TOP) C1 18 min. NO1 NO2 18 min. NC1 NC2 C2 SPDT has NC1, NO1, and C1 only. 18 min. Note: Determine mounting centers to ensure easy operation. 10 24 min. All dimensions in mm. (06/11/10) o16 A6 Series Miniature Control Units AS6M Key Selector Switches Shape Position Operation Type Round AS6M Key Retained at L A Maintained 90 2-position C Spring return from right Maintained 45 3-position Spring return from right Spring return from left Spring return two-way * * * * Key is retained at positions and removable at Two keys are supplied. The front of key cylinder is made of metal. See page 14 for dimensions. B AS6M-2KT1PA AS6M-2KT2A AS6M-2KT2PA SPDT AS6M-2KT1B AS6M-2KT1PB DPDT AS6M-2KT2B AS6M-2KT2PB SPDT AS6M-2KT1C AS6M-2KT1PC DPDT AS6M-2KT2C AS6M-2KT2PC SPDT AS6M-21KT1B AS6M-21KT1PB DPDT AS6M-21KT2B AS6M-21KT2PB R DPDT AS6M-3KT2A AS6M-3KT2PA R DPDT AS6M-3KT2B AS6M-3KT2PB R DPDT AS6M-3KT2C AS6M-3KT2PC R DPDT AS6M-3KT2D AS6M-3KT2PD R DPDT AS6M-3KT2E AS6M-3KT2PE R DPDT AS6M-3KT2G AS6M-3KT2PG R DPDT AS6M-3KT2H AS6M-3KT2PH R DPDT AS6M-31KT2B AS6M-31KT2PB R DPDT AS6M-31KT2D AS6M-31KT2PD R DPDT AS6M-31KT2G AS6M-31KT2PG R DPDT AS6M-32KT2C AS6M-32KT2PC DPDT AS6M-32KT2D AS6M-32KT2PD R DPDT AS6M-32KT2H AS6M-32KT2PH R DPDT AS6M-33KT2D AS6M-33KT2PD R L R L B L C L D L E L G L H L B L D L G L C L D AS6M-2KT1A L A L H L D L C C C C C C C C C C C C C IP65 SPDT R C Type No. IP40 DPDT R L B Contact R positions. Contact Operation Operator Position & Contact Operation (Top View) Positions Contact Left Center Right NO NC NO NC SPDT L R L R C 90 2-position Maintained -- C Left Right Contact Contact NO NC NO NC Left Right Contact Contact NO NC NO NC Spring return from right DPDT -- C C L C R L R C L R L R 45 3-position DPDT Maintained (06/11/10) Spring return from right Spring return from left Spring return two-way C C C Left Right Contact Contact NO NC NO NC C C Left Right Contact Contact NO NC NO NC C C C Left Right Contact Contact NO NC NO NC C C 11 o16 A6 Series Miniature Control Units AS6Q Key Selector Switches Shape Position Key Retained at Operation Type Square AS6Q A Maintained B 90 2-position C Spring return from right Maintained 45 3-position Spring return from right Spring return from left Spring return two-way * * * * Key is retained at positions and removable at Two keys are supplied. The front of key cylinder is made of metal. See page 14 for dimensions. B L AS6Q-2KT1PA AS6Q-2KT2A AS6Q-2KT2PA SPDT AS6Q-2KT1B AS6Q-2KT1PB DPDT AS6Q-2KT2B AS6Q-2KT2PB SPDT AS6Q-2KT1C AS6Q-2KT1PC DPDT AS6Q-2KT2C AS6Q-2KT2PC SPDT AS6Q-21KT1B AS6Q-21KT1PB DPDT AS6Q-21KT2B AS6Q-21KT2PB R DPDT AS6Q-3KT2A AS6Q-3KT2PA R DPDT AS6Q-3KT2B AS6Q-3KT2PB R DPDT AS6Q-3KT2C AS6Q-3KT2PC R DPDT AS6Q-3KT2D AS6Q-3KT2PD R DPDT AS6Q-3KT2E AS6Q-3KT2PE R DPDT AS6Q-3KT2G AS6Q-3KT2PG R DPDT AS6Q-3KT2H AS6Q-3KT2PH R DPDT AS6Q-31KT2B AS6Q-31KT2PB R DPDT AS6Q-31KT2D AS6Q-31KT2PD R DPDT AS6Q-31KT2G AS6Q-31KT2PG R DPDT AS6Q-32KT2C AS6Q-32KT2PC DPDT AS6Q-32KT2D AS6Q-32KT2PD R DPDT AS6Q-32KT2H AS6Q-32KT2PH R DPDT AS6Q-33KT2D AS6Q-33KT2PD R L R L B L C L D L E L G L H L B L D L G L C L D AS6Q-2KT1A L A L H L D L C C C C C C C C C C C C C IP65 SPDT R C IP40 DPDT R L Type No. Contact R positions. Contact Operation Operator Position & Contact Operation (Top View) Positions Contact Left Center Right NO NC NO NC SPDT L R L -- R C C 90 2-position Maintained Spring return from right DPDT Left Right Contact Contact NO NC NO NC C C C L R L C R L R L R 45 3-position DPDT Maintained Spring return Spring return Spring return two-way from right from left 12 C -- C C Left Right Contact Contact NO NC NO NC C Left Right Contact Contact NO NC NO NC C Left Right Contact Contact NO NC NO NC C C C Left Right Contact Contact NO NC NO NC C C (06/11/10) o16 A6 Series Miniature Control Units AS6H Key Selector Switches Shape Position Key Retained at Operation Type Rectangular AS6H A Maintained B 90 2-position C Spring return from right Maintained 45 3-position Spring return from right Spring return from left Spring return two-way * * * * Key is retained at positions and removable at Two keys are supplied. The front of key cylinder is made of metal. See page 14 for dimensions. B L AS6H-2KT1PA AS6H-2KT2A AS6H-2KT2PA SPDT AS6H-2KT1B AS6H-2KT1PB DPDT AS6H-2KT2B AS6H-2KT2PB SPDT AS6H-2KT1C AS6H-2KT1PC DPDT AS6H-2KT2C AS6H-2KT2PC SPDT AS6H-21KT1B AS6H-21KT1PB DPDT AS6H-21KT2B AS6H-21KT2PB R DPDT AS6H-3KT2A AS6H-3KT2PA R DPDT AS6H-3KT2B AS6H-3KT2PB R DPDT AS6H-3KT2C AS6H-3KT2PC R DPDT AS6H-3KT2D AS6H-3KT2PD R DPDT AS6H-3KT2E AS6H-3KT2PE R DPDT AS6H-3KT2G AS6H-3KT2PG R DPDT AS6H-3KT2H AS6H-3KT2PH R DPDT AS6H-31KT2B AS6H-31KT2PB R DPDT AS6H-31KT2D AS6H-31KT2PD R DPDT AS6H-31KT2G AS6H-31KT2PG R DPDT AS6H-32KT2C AS6H-32KT2PC DPDT AS6H-32KT2D AS6H-32KT2PD R DPDT AS6H-32KT2H AS6H-32KT2PH R DPDT AS6H-33KT2D AS6H-33KT2PD R L R L B L C L D L E L G L H L B L D L G L C L D AS6H-2KT1A L A L H L D L C C C C C C C C C C C C C IP65 SPDT R C IP40 DPDT R L Type No. Contact R positions. Contact Operation Operator Position & Contact Operation (Top View) Positions Contact Left Center Right NO NC NO NC SPDT L R L R C 90 2-position Maintained -- C Left Right Contact Contact NO NC NO NC Left Right Contact Contact NO NC NO NC Spring return from right DPDT -- C C C L R L C R L R L R 45 3-position DPDT Maintained Spring return Spring return Spring return two-way from right from left (06/11/10) C C C Left Right Contact Contact NO NC NO NC C C Left Right Contact Contact NO NC NO NC C C C Left Right Contact Contact NO NC NO NC C C 13 o16 A6 Series Miniature Control Units Dimensions 2.5 Right Contact 3 TOP Left Contact Rubber Gasket Terminal Width 2.8x0.5t 2.5 Anti-rotation Ring 3 Panel Thickness 0.5 to 6 Locking Ring Rectangular (TOP) Square (TOP) Round (TOP) 18 5 NC 5 NO C 1 8 22 26 24 18 o18 Terminal Arrangement (bottom view) (Key Selector Switch) (TOP) NC1 NC2 NO1 NO2 C1 C2 SPDT has NC1, NO1, and C1 only. Mounting Hole Layout * Round/Square +0.2 0 o16.2 +0.2 0 18 min. 18 min. o16.2 * Rectangular 18 min. 24 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 14 (06/11/10) A6 Series Miniature Control Units o16 Accessories Shape Material Type No. Ordering Type No. Package Quantity Locking Ring Wrench o18 60 Lamp Holder Tool Metal (nickel-plated brass) MT-001 MT-001 1 * Used to tighten the locking ring when installing A6 control units into a panel. * Tighten the locking ring to a torque of 0.88 N*m maximum. Rubber OR-77 OR-77 1 * Used to install and remove the LED lamps. Stainless Steel MT-101 MT-101 1 * Used to install and remove lenses and buttons. AL-K6 AL-K6 1 o9 o10 Dimensions (mm) 55 Lens Removal Tool 60 Switch Guard For round/ square units (remains 90 open) For rectangular units (remains 110 open) Guard (polyarylate) Base (polyacetal) Spring Return For round/ square units (180 spring return) See page 17 for dimensions. For rectangular units (180 spring return) For round units For square units For rectangular units Terminal Cover Translucent nylon (white) See page 18 for dimensions. Solder Terminal PC Board Terminal See page 18 for dimensions. 1 AL-K6S AL-K6S 1 AL-K6SP AL-K6SP 1 AL-KH6S AL-KH6S 1 AL-KH6SP AL-KH6SP 1 AL-D6 AL-D6 1 AL-DQ6 AL-DQ6 1 AL-DH6 AL-DH6 1 AL-V6 AL-V6PN10 10 AL-C6 AL-C6 1 AL-C6V AL-C6V 1 * Degree of protection: IP65 (when used with IP65 control units) * Used to protect pushbuttons from inadvertent operation. * Degree of protection: IP40 * Used to protect pushbuttons from inadvertent operation. * Degree of protection: IP65 (when used with IP65 control units) * Used to protect pushbuttons from inadvertent operation. * When mounting the control units with the dust covers installed, refer to mounting hole layout on page 18. * Operating temperature: -10 to +55C * When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. * Terminal cover is not attached and must be ordered separately. * Plugs on the rear of the A series control units. * Degree of protection: IP65 AL-B6PN05 o1 Mounting Hole AL-B6 5 o18 Nitryl rubber (black) Mounting Hole Plug o16.5 Rubber 6 2 + 0 0 .2 2 6. Mounting Hole Plug * Degree of protection: IP65 1 Gasket 0 .2 Mounting Hole AL-BM6 o17.8 Metal 12 2 + 0 2.5 Metal (diecast) AL-BM6 * Locking ring: plastic 6. Socket Translucent cover: elastomer Black part: polypropylene AL-KH6 o1 Dust Cover AL-KH6 * Degree of protection: IP40 * Used to protect pushbuttons from inadvertent operation. Locking Ring Panel Thickness 0.5 to 6 All dimensions in mm. (06/11/10) 15 o16 A6 Series Miniature Control Units Maintenance Parts Shape Lens Specification Round AL6M-LPN05 AL6Q-L AL6Q-LPN05 AL6H-L AL6H-LPN05 AB6M-B AB6M-BPN05 AB6Q-B AB6Q-BPN05 Rectangular AB6H-B AB6H-BPN05 Round AL6M-W AL6M-WPN05 AL6Q-W AL6Q-WPN05 Polyarylate Rectangular Round Square Marking Plate Polyarylate Square Acrylic Rectangular Large Lens Unit Ordering Type No. AL6M-L Square Button Type No. Round (installed on round units) Square (installed on square units) Rectangular (installed on square units) AL6H-W AL6H-WPN05 Translucent color lens AL6M-LK2-M AL6M-LK2-M Opaque button AB6M-BK2-M AB6M-BK2-M Translucent color lens AL6Q-LK2-Q Opaque button AB6Q-BK2-Q AB6Q-BK2-Q Translucent color lens AL6Q-LK2-H AL6Q-LK2-H Opaque button AB6Q-BK2-H AB6Q-BK2-H Plastic HA9Z-LN HA9Z-LNPN10 Package Quantity Color Code Specify a color code in place of in the Type No. A (amber), C (clear), G (green) R (red), S (blue), Y (yellow) * Use a C (clear) lens for W (white) and JW (pure white) illumination. 5 Specify a color code in place of in the Type No. B (black), G (green), R (red) S (blue), W (white), Y (yellow) * White * Specify a color code in place of in the Type No. * Degree of protection: IP65 Color Code Translucent Color Lens A (amber) G (green) R (red) S (blue) W (white) Y (yellow) AL6Q-LK2-Q 1 Opaque Button B (black) G (green) R (red) S (blue) W (white) Y (yellow) * See page 18 for dimensions. Locking Ring * Black 10 Anti-rotation Ring Metal AL6-LP AL6-LPPN10 Brass with nickel plating AS6-SK-132 AS6-SK-132PN02 Spare key For key selector switches 2 * Thickness 2.0 mm LED Lamps Operating Voltage Current Draw AC DC -- 8 mA Type No. 5V DC 5% Ordering Type No. LATD-5 LATD-5 LATD-5PN10 12V AC/DC 10% LATD-1 9 mA 8 mA LATD-1 LATD-1PN10 24V AC/DC 10% LATD-2 9 mA 8 mA LATD-2 LATD-2PN10 16 Illumination Color Code Package Quantity Specify a color code in place of in the Ordering Type No. 1 A: G: JW: R: S: W: Y: amber green pure white red blue white yellow Base 10 1 10 Exclusive for A6 series 1 10 (06/11/10) o16 A6 Series Miniature Control Units Transformer Shape Separate Mounting Type for 24V Primary Voltage Secondary Voltage Type No. 100/110V AC Applicable LED Lamp TWR512 200/220V AC 24V AC, 0.5W TWR522 400/440V AC LATD-2 TWR542 * Terminal covers are supplied with separate mounting type transformers. * Connect only one LATD LED to separate mounting type transformers. * Use mounting bracket BC9Z-E/NS35N when using on 400/440V primary voltage. Dimensions Specifications Power Consumption Rated Insulation Voltage Insulation Resistance Operating Standard Temperature Operating Condition Relative Humidity Operation Vibration Resistance Extremes Shock Resistance Damage Limits Dielectric Strength Terminal Screw Applicable Wire Secondary Side 40 48 Mounting Holes 2-o3.3 -30 to +60C (no freezing) Primary Side 35 to 85% (no condensation) 52 5 to 55 Hz, amplitude 0.5 mm 1,000 m/s2 2500V AC, 1 minute M3.5 2 mm2 maximum, 2 wires maximum Terminal Cover 40 41 Operating Voltage 22 30 M3.5 Terminal Screws 100/110V AC, 200/220V AC, 400/440V AC (50/60 Hz) 2.4VA 600V 100 M minimum (500V DC megger) Accessories Description Appearance Description DIN Rail Mounting Clip 9.5 Type No. Ordering Type No. Aluminum Weight: Approx. 200g BAA1000 BAA1000PN10 Steel Weight: Approx. 320g BAP1000 BAP1000PN10 Steel Weight: Approx.15g BNL6 BNL6PN10 Plastic Weight: Approx.15g BC9Z-E/NS35N BC9Z-E/NS35NPN10 Package Quantity 10 32.8 48.6 * Use mounting clip BC9Z-E/NS35N when using on 400/440V primary voltage. Maintenance Parts Dimensions 13 26.5 minimum Panel Thickness 0.5 to 5 32 33 (45.5 minimum for 180 opening type) 26.5 minimum 24 10.5 13 10.5 23.5 18 (06/11/10) 25 minimum R2 2 Rubber Gasket 14 28 (90/110 opening type) 19 minimum Panel Thickness 0.5 to 5 34 For rectangular units (AL-KH6) (AL-KH6S) 23.5 For Round/Square Units (AL-K6) (AL-K6S) (45.5 minimum for 180 opening type) * Switch Guard (Degree of protection: IP40) Rubber Gasket 14 28 (180 opening type) All dimensions in mm. 17 o16 A6 Series Miniature Control Units * Switch Guard (Degree of protection: IP65) For Round/Square Units (AL-K6SP) For Rectangular Units (AL-KH6SP) 45.5 min. 23.5 10.5 13 45.5 min. 23.5 10.5 13 Waterproof Gasket for Switch Guard R2 2 24 33 18 Panel Thickness 0.5 to 5 34 Rubber Gasket 0.4 28 14 19 min. 25 min. * Socket 8-1.6 2.5 Terminal 1.5x0.3t 33.5 TOP 2.5 3 +0.3 0 Holes 3 2.4 33.5 (TOP) 5 5 5 5 NC1 NC2 NO1 NO2 16.2 6 7.5 6 16.2 Solder Terminal Type (AL-C6) 3.8 PC Board Terminal Type (AL-C6V) 6 6 Lamp Terminal (+) PC Board Mounting Hole Layout (Bottom View) C1 C2 Lamp Terminal (-) Terminal Arrangement (Bottom View) * Terminal Cover 17.3 o16.8 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. 33.5 * Mounting Hole Centers * Dust Cover For Square Units (AL-DQ6) For Round Units (AL-D6) For Rectangular Units (AL-DH6) c 24 30 o16.2 Rectangular Units +0.2 0 o16.2 +0.2 0 13 24 min. 7.5 7.5 13 7.5 13 24 min. 24 o24 Round/Square Units 30 min. Waterproof Gasket for Dust Cover 0.3 0.3 0.3 24 min. Waterproof Gasket for Dust Cover Waterproof Gasket for Dust Cover * Large Lens and Large Button Rubber Gasket Anti-rotation Ring Teminal Width 2.8x0.5t Locking Ring 2.5 3 Panel Thickness 0.5 to 6 6 6 1 8 0.6 22 9 15.5 23.5 Round (TOP) c 23.5 o23.5 Square (TOP) 17.5 5 5 Rectangular (TOP) 0.6 9 15.5 0.6 12.5 All dimensions in mm. 18 (06/11/10) A6 Series Miniature Control Units o16 Safety Precautions * Turn off the power to A series control units before starting installation, removal, wiring, maintenance, and inspection of the control units. Failure to turn power off may cause electrical shocks or fire hazard. * To avoid a burn on your hand, use the lamp holder tool when replacing lamps. * For wiring, use wires of a proper size to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions Replacement of Lens and Marking Plate Panel Mounting * Removal When mounting the control units into a panel, use the optional locking ring wrench (MT-001) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.88 N*m. Excessive tightening will damage the locking ring. Remove the lens assembly (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the Lens Removal Tool (MT-101) and pulling it out. Remove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be Fitting Grooves engraved on the front side Grooves as shown at right. When using a color film, insert it between the color Engraving Surface lens and marking plate. * Installation Color Lens Marking Plate Wiring Solder the terminal at 350C within 3 seconds using a 60W soldering iron. Sn-Ag-Cu type is recommended when using leadfree solder. When soldering, do not touch the control unit with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use a non-corrosive rosin flux. Lens Holder Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. Installing the Socket Marking Waterproof (IP65) / oiltight type switch guards must be used with waterproof (IP65) / oiltight type control units only. Even if IP65 type switch guards are installed, enclosed type (IP40) control units are not made waterproof. For A series illuminated pushbuttons, legends and symbols can be engraved on the built-in marking plates, or printed film can be inserted under the lens for labelling purposes. 12.0 Rectangular Engraving Area 12.0 0.8 13.6 o13.6 11.8 c13.6 19.6 * Thickness = 0.1 mm x 1 film * Recommended film material: polyester Use the lamp holder tool (OR-77) to remove lamps. Do not use pliers. * Installation Use the lamp holder tool (OR-77) to install lamps. Note the correct side of the tool for removal or installation. For removing lamps IP40 IP40 IP40 Operating Voltage of LED Lamps Other Notes * Close Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the control units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. * Operating and Storage Environment 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed type units in an environment subject to oil, water or dust accumulation. In such an area, use the waterproof/ oiltight units (IP65). * Microswitch Contacts Do not connect NO and NC contacts of a microswitch to different voltages or different power sources to prevent a dead short-circuit. OR-77 o9 o10 IP65 IP40 (enclosed type) Do not replace buttons of maintained action units while the button is in the locked position. Replacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. * Removal 55 All dimensions in mm. (06/11/10) IP65 (waterproof) * Replacement of Buttons (Illuminated/Non-illuminated) Replacing the LED Lamp For installing lamps Control Unit The operating voltage of 5V DC is measured at complete DC. * Engraving must be made on the engraving area within 0.5mm deep. * The marking plate is made of white acrylic resin. Applicable Marking Film (not supplied) Switch Guard IP65 (waterproof) IP40 (enclosed type) Engraving Area 18.0 c12.0 0.8 o12.0 0.8 Built-in Marking Plate and Engraving Area Square Engraving Area Switch Guard Item Marking Plate & Engraving Area Round Install the socket on the control unit with the TOP markings on the control unit and the socket placed in the same direction. * IP65 Type Units IP65 type units are evaluated by conventional cutting and cooling oils, and can not be used with some special oils. Contact IDEC for resistance against specific oils. 19 o16 Flush Silhouette L6/A6 Series Accessories New flush silhouette bezels for L6/A6 series o16mm miniature control units * Accessories for L6/A6 control units. * Bezel Size Round: o24 mm (Panel Cut-out: o20.2 mm) Square: 24 mm (Panel Cut-out: 20.2 mm) Rectangular: 24x30 mm (Panel Cut-out: 20.2x26.2 mm) * Applicable models L6 Series Illuminated Pushbutton Pilot Light Pushbutton Selector Switch Key Selector Switch Illuminated Selector Switch Lever Switch Buzzer A6 Series Illuminated Pushbutton Pilot Light Pushbutton Selector Switch Key Selector Switch Illuminated Selector Switch Note: Flush silhouette bezels cannot be used for mushroom buttons or lenses. Flush Bezel Shape Type Package Quantity Metal (aluminum color) LA9Z-SM61 1 Plastic (black) LA9Z-S61B 1 Specification Remarks Round Round Flush Bezel * Degree of protection: IP65 (only when used with IP65 control units) Square Plastic (black) LA9Z-S71B 1 Plastic (black) LA9Z-S81B 1 Rectangular Switch Guard with Flush Bezel (Spring Return) Rectangular Rubber Boot Plastic LA9Z-KS8 1 Round LA9Z-DS6 1 Square LA9Z-DS7 1 Rectangular LA9Z-DS8 1 * Used for L6/A6 rectangular pushbuttons and illuminated pushbuttons. Cannot be used for selector switches, illuminated selector switches, and lever switches. * Degree of protection: IP65 (only when used with IP65 control units) * Rubber boot is supplied with a flush bezel. * Degree of protection: IP65 * Applicable type: L6/A6 series illuminated pushbuttons and pushbuttons Note: Terminal covers and maintenance parts for L6/A6 other than those shown above can also be used, except switch guard (AL-K) and rubber boot (AL-D). 20 (06/11/10) Flush Silhouette L6/A6 Series Control Units Shape Specification Package Quantity Type o16 Remarks Round Plastic (black) LA9Z-BS6 1 Plastic (black) LA9Z-BS7 1 Plastic (black) LA9Z-BS8 1 Square Mounting Hole Plug * Degree of protection: IP65 * Panel thickness: 0.5 to 5 mm Rectangular Ordering Information Specifications * Control units are not supplied with flush bezels. Order flush bezels together with control units. * Based on L6/A6 series control unit specifications. Dimensions Flush Bezel with Control Units Flush Bezel Mounting Bracket Flush Bezel Gasket * L6 Series Plastic Metal * A6 Series 8 o2 o2 8.5 4 8 o1 4 o1 0.9 0.8 9.8 Panel Thickness 0.5 to 5 14.8 o 20 22.6 * Round o21.4 Panel Thickness 0.5 to 5 2 9 43 1 2 8 29 2 18 24 20 21.4 * Square 20 21.4 * Rectangular 2 A 26 27.4 24 30 23 * Key Selector Switch * Lever Switch 24 18 * Selector Switch * Illuminated Selector Switch 2 2 B Unit L6 selector switch L6 illuminated selector A6 selector switch A (mm) 10.0 10.0 8.5 Unit L6 key selector A6 key selector 17 B (mm) 18.1 18.1 Mounting Hole Layout * Rectangular * Square + - 0 0.2 .1 * Round Mounting hole layout for the L6 series is the same for both straight-lever contact type and L-lever contact type. 26.2 +0.2 - 0.1 24 24 24 +0.2 20.2 -0.1 o2 0. 2 20.2 +0.2 - 0.1 24 24 30 When mounting the rubber boot: Round and square types: 27 mm minimum Rectangular type: Vertical 27 mm, Horizontal 33 mm miniumum (06/11/10) 21 o16 Flush Silhouette L6/A6 Series Accessories Flush Bezel with Switch Guard * L6 Series [Mounting Hole Layout] * A6 Series Panel Thickness 0.5 to 5 26.4 26.4 33.1 30 24 33.1 47.5 Panel Thickness 0.5 to 5 Mounting holes are the same size as rectangular flush bezels. 1 9 43 8 5.4 29 5.4 30 Mounting Hole Plug Gasket Panel Thickness 0.5 to 5 * Round * Square * Rectangular Mounting holes are the same size as flush bezels. Mounting Bracket Locking Ring 4 30.3 2 24 24 o2 30 Rubber Boot Panel Thickness 0.5 to 5 7 6 27 6 1 o2 10.5 9 20.5 4 27 33 43 L6 Series Solder/Tab Terminal All dimensions in mm. Safety Precautions * Turn off the power to the control units before starting installation, removal, wiring, maintenance, and inspection of the products. Failure to turn power off may cause electrical shocks or fire hazard. * For wiring, use wires of a proper size to meet the voltage and current requirements and solder correctly. Improper soldering may cause overheating and fire hazard. Also, when using tab terminals, use appropriate quick connect receptacles. * To avoid burning your hand, use the lamp holder tool when replacing lamps. 22 (06/11/10) Flush Silhouette L6/A6 Series Accessories o16 Instructions Panel Mounting of Flush Bezels * L6 series 1. Remove the contact block from the operator. Remove the locking ring and anti-rotation ring. To remove the operator from the contact block, turn the locking lever in the direction opposite to the arrow on the housing. 2. Attach the flush bezel to the operator. Then insert the assembly into the panel. Attach the mounting bracket and tighten the locking ring. (Do not use the anti-rotation ring supplied with the operator.) For round flush bezels, place the projection on the bezel to the groove on the TOP side of the operator and mount onto the panel. 3. Insert the contact block, with the TOP markings on the contact block and the operator placed in the same direction. Then lock the units, turning the locking lever in the direction of the arrow. Anti-rotation ring supplied with the operator Panel Installing the Rubber Boot Replacing the Lens Attach the rubber boot and the flush bezel to the operator. Then insert the assembly into the panel. Attach the mounting bracket and tighten the locking ring. Tighten the locking ring to the recommended tightening torque of 0.88N*m. (Do not use the anti-rotation ring supplied with the operator.) * Removing Remove the lens assembly (lens, marking plate, and lens holder) from the operator by holding the lens removal tool (MT-101) and pull out. Anti-rotation ring supplied with the operator Panel Mounting bracket supplied with the flush bezel Rubber boot for flush silhouette control units L6/A6 series operator unit Flush bezel for rubber boot * Installing Insert the operator in the correct direction. * Precautions for Installing the Rubber Boot Install the rubber boot to wrap around the entire periphery of the flush bezel. Make sure that the projection on the rubber boot is placed into the groove on the back of the bezel. If the projection is not placed correctly, the normal waterproof/dustproof characteristics are not ensured. Mounting bracket supplied with the flush bezel Remove Locking ring Remove Projection on the rubber boot Rubber boot installed on the flush bezel Correct Locking ring Groove on the rubber boot L6/A6 Operator Flush Bezel/ Flush Bezel with Switch Guard Incorrect Install * A6 series 1. Remove the locking ring and antirotation ring from the operator. 2. Attach the flush bezel to the operator. Then insert the assembly into the panel. Attach the mounting bracket and tighten the locking ring. (Do not use the anti-rotation ring supplied with the operator.) For round flush bezels, place the projection on the bezel to the groove on the TOP side of the operator and mount onto the panel. Panel Mounting of Flush Bezels with Switch Guard For installation, see Panel Mounting of Flush Bezels. * For other instructions, refer to L6 series catalog and page 19. (06/11/10) 23 A2 Series Miniature Control Units o12 Short 22-mm-long body miniature control unit series with bright LED illumination face and snap-action switching. * Available in enclosed (IP40) and waterproof (IP65), and oiltight types. * 12-mm mounting holes * All series have terminals on the same plane. * UL recognized, CSA certified Contact Ratings (Contact Block) Specifications Rated Insulation Voltage 250V Operating Temperature -25 to +55C (no freezing) Rated Thermal Current 3A Storage Temperature -30 to +80 45 to 85% RH (no condensation) 24V 110V 220V Operating Humidity Resistive Load - 1.0A 0.5A Contact Resistance 50 m maximum (initial value) Inductive Load - 0.7A 0.5A Insulation Resistance 100 M minimum (500V DC megger) Operating Voltage (AC/DC) AC 50/60 Hz DC Resistive Load 1.0A 0.2A - Inductive Load 0.7A 0.1A - Contact Material Silver Dielectric Strength * Minimum applicable load: 5V AC/DC, 3 mA (applicable range may vary with operating conditions and load types) Weight Switch Unit Between live and dead metal parts: 2,000V AC, 1 minute Between terminals of different poles: 2,000V AC, 1 minute Between terminals of the same pole: 1,000V AC, 1 minute Between contact and lamp terminals: 1,500V AC, 1 minute Illumination Unit Between live part and ground: 2,000V AC, 1 minute AL2M-M11: 4g Weight (approx.) AL2M-P1: 4g AB2M-M1: 4g Vibration Resistance Operating extremes: 5 to 55 Hz, amplitude 0.75 mm Shock Resistance Damage limits: 500 m/s2 (50G) Operating extremes: 200 m/s2 (20G) Mechanical Durability (minimum operations) Momentary: 200,000 operations Maintained: 100,000 operations Electrical Durability (minimum operations) Momentary: 100,000 operations Maintained: 50,000 operations (Switching frequency 1200 operations/h) Degree of Protection Enclosed (IP40) Waterproof, dust-tight (IP65) LED Lamp Ratings (LAD-S Type) Type No. LAD-SA Lamp Base LAD-SG LAD-SR LAD-SY Exclusive for A series control units Forward Current (If) 20 mA Forward Voltage (Vf) (nominal) 2.2V 2.1V 1.7V Reverse Voltage (Vr) 2.2V 4V Illumination Color A G R Y LED Lamp Color Amber Clear Yellow Diffused Red Clear Yellow Clear Amber Green Red Yellow and White Applicable Lens Color Base Plastic Color Red LED Lamp Life (reference value) Approx. 50,000 hours (The illuminance reduces to 50% the initial intensity when used on complete DC.) Operating Voltage & External Current-limiting Resistor (recommended value) (Note) Internal Circuit 5V DC: 6V DC: 12V DC: 24V DC: 150, 1/2W 200, 1/2W 510, 1W 1.1 k, 1W (+) (-) Note: When LED lamps are used on voltages other than the above, external resistor value R is determined by the following formula: R = (operating voltage - Vf) / If * LED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage must be provided. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. Because no protection diode is contained, ensure the correct polarity is observed. 24 (+) (-) Current Limiting Resistor Lamp Terminal (+) Lamp Terminal (-) (06/11/10) o12 A2 Series Miniature Control Units AL2 LED Illuminated Pushbuttons & Pilot Lights Type No. Operation Type Shape Round AL2M Contact IP40 IP65 SPDT AL2M-M11 AL2M-M11P DPDT AL2M-M21 AL2M-M21P SPDT AL2M-A11 AL2M-A11P DPDT AL2M-A21 AL2M-A21P -- AL2M-P1 AL2M-P1P SPDT AL2Q-M11 AL2Q-M11P DPDT AL2Q-M21 AL2Q-M21P SPDT AL2Q-A11 AL2Q-A11P DPDT AL2Q-A21 AL2Q-A21P -- AL2Q-P1 AL2Q-P1P SPDT AL2H-M11 AL2H-M11P DPDT AL2H-M21 AL2H-M21P SPDT AL2H-A11 AL2H-A11P DPDT AL2H-A21 AL2H-A21P -- AL2H-P1 AL2H-P1P Lens Color Code LED Lamp Type No., Rated Current (External Resistor Recommended Value) Momentary Maintained Marking plate size: o10 mm Engraving area: o8.2 mm (Depth: 0.5 mm max.) Square AL2Q Pilot Light Momentary Maintained Marking plate size: 10 mm Engraving area: 8.2 mm (Depth: 0.5 mm max.) Rectangular AL2H Pilot Light Specify a color code in place of in the Type No. A: amber G: green R: red W: white Y: yellow A: G: R: W/Y: LAD-SA LAD-SG LAD-SR LAD-SY Rated Current: 20 mA 5V DC: 6V DC: 12V DC: 24V DC: 150, 1/2W 200, 1/2W 510, 1W 1.1 k, 1W Momentary Maintained Marking plate size: 10 x 14 mm Engraving area: 8.2 x 12.2 mm Pilot Light (Depth: 0.5 mm max.) * LED lamps do not have a current-limiting resistor. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. * External current-limiting resistor is not necessary when an optional socket with built-in resistor is used (see page 27). LED Lamp * AP2M series pilot lights (round bezel only) with built-in current-limiting resistors are also available. Internal Circuit (+) (-) Dimensions Panel Thickness 0.5 to 6 Rubber Gasket Rectangular (TOP) Locking Ring Square (TOP) Round (TOP) c14 o14 2.8 5 5.5 o14 14 9.2 2.8 Terminal Width 1.8x0.4t 0.6 7 Terminal Arrangement 22 0.6 9 18 9 Mounting Hole Layout * Round/Square Units Lamp Terminal (+) 5.5 (TOP) o12 * Rectangular Units +0.2 0 o12 +0.2 0 NC1 NC2 C1 C2 Note: Determine mounting centers to ensure easy operation. 14 min. 14 min. NO1 NO2 SPDT has NC1, NO1, and C1 only. Lamp Terminal (-) 14 min. 18 min. All dimensions in mm. (06/11/10) 25 o12 A2 Series Miniature Control Units AB2 Pushbuttons Shape Operation Type Button Type Round AB2M Momentary Button Maintained Momentary Illumination Lens Maintained Square AB2Q Momentary Button Maintained Momentary Illumination Lens Maintained Rectangular AB2H Type No. Contact Momentary Button Maintained Momentary Illumination Lens Maintained IP40 IP65 SPDT AB2M-M1 AB2M-M1P DPDT AB2M-M2 AB2M-M2P SPDT AB2M-A1 AB2M-A1P DPDT AB2M-A2 AB2M-A2P SPDT AB2M-M1L AB2M-M1PL DPDT AB2M-M2L AB2M-M2PL SPDT AB2M-A1L AB2M-A1PL DPDT AB2M-A2L AB2M-A2PL SPDT AB2Q-M1 AB2Q-M1P DPDT AB2Q-M2 AB2Q-M2P SPDT AB2Q-A1 AB2Q-A1P DPDT AB2Q-A2 AB2Q-A2P SPDT AB2Q-M1L AB2Q-M1PL DPDT AB2Q-M2L AB2Q-M2PL SPDT AB2Q-A1L AB2Q-A1PL DPDT AB2Q-A2L AB2Q-A2PL SPDT AB2H-M1 AB2H-M1P DPDT AB2H-M2 AB2H-M2P SPDT AB2H-A1 AB2H-A1P DPDT AB2H-A2 AB2H-A2P SPDT AB2H-M1L AB2H-M1PL DPDT AB2H-M2L AB2H-M2PL SPDT AB2H-A1L AB2H-A1PL DPDT AB2H-A2L AB2H-A2PL Color Code B: G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow B: G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow B: G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow * Specify a color code in place of or in the Type No. Dimensions Panel Thickness 0.5 to 6 Rubber Gasket Locking Ring Square (TOP) Round (TOP) c14 o14 5 0.6 5.5 22 Terminal Arrangement (TOP) 0.6 9 18 * Round/Square Units o12 * Rectangular Units +0.2 0 14 min. C1 C2 9 Mounting Hole Layout NC1 NC2 NO1 NO2 5.5 o12 +0.2 0 14 min. 2.8 14 2.8 Rectangular (TOP) SPDT has NC1, NO1, and C1 only. 14 min. 18 min. Note: Determine mounting centers to ensure easy operation. 26 All dimensions in mm. (06/11/10) o12 A2 Series Miniature Control Units Accessories Shape Material Type No. Ordering Type No. Package Quantity Locking Ring Wrench o14 Dimensions (mm) Metal (nickel-plated brass) MT-002 MT-002 1 * Used to tighten the locking ring when installing the A2 control units into a panel. * Tighten the locking ring to a torque of 0.78 N*m maximum. Stainless Steel MT-101 MT-101 1 * Used to remove lens and button. Rubber OR-66 OR-66 1 * Used to remove and install LED lamps. AL-K2 AL-K2 1 AL-KH2 1 60 Lens Removal Tool 60 Lamp Holder Tool 70 Switch Guard For round/ square Unit 90 open For rectangular AL-KH2 unit * Degree of protection: IP40 * Used to protect pushbuttons from inadvertent operation. * See page 28 for dimensions. (remains 90 open) Socket Solder Terminal AL-C2 AL-C2 1 PC Board Terminal AL-C2V AL-C2V 1 5V DC AL-C21 AL-C21 1 Blue 6V DC AL-C22 AL-C22 1 Green 12V DC AL-C23 AL-C23 1 24V DC AL-C24 AL-C24 1 5V DC AL-C21V AL-C21V 1 6V DC PC Board Terminal 12V DC AL-C22V AL-C22V 1 AL-C23V AL-C23V 1 Yellow 24V DC AL-C24V AL-C24V 1 Red Solder Terminal Terminal Cover Nylon AL-V2 AL-V2PN10 10 For round units AL-D2 AL-D2 1 For square units AL-DQ2 AL-DQ2 1 For rectangular units AL-DH2 AL-DH2 1 Nitryl rubber (black) AL-B2 AL-B2PN05 5 Illumination color: amber LAD-SA Illumination color: green LAD-SG Illumination color: red LAD-SR Illumination color: yellow LAD-SY LAD-SA LAD-SAPN10 LAD-SG LAD-SGPN10 LAD-SR LAD-SRPN10 LAD-SY LAD-SYPN10 1 10 1 10 1 10 1 10 Dust Cover Socket Bottom Color Socket with Built-in Resistor * Snaps on the rear of the A2 series control units. (see page 28 for dimensions) Yellow Red Blue Green * A current limiting resistor is contained, eliminating the need for external resistors. * When using the socket with a built-in resistor, make sure that the continuous current is 1A maximum and the operating temperature is -25 to +40C. In collective mounting, keep center-to center-spacing of 20 mm or more between adjacent units in consideration of built-in resistor heating. * See page 28 for dimensions. * When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. * Terminal cover is not attached and must be ordered separately. * When mounting the control units with the dust covers installed, refer to mounting hole layout on page 29. * Operating temperature: -10 to +55C * Material Front part: Elastomer (transparent) Rear part: Polypropylene (black) * See page 29 for dimensions and mounting hole layout. Mounting Hole Plug 5.3 9.0 All dimensions in mm. (06/11/10) Amber LED color: amber clear Lens color Current-limiting resistor is not contained. o4.0 LED Lamp * Degree of protection: IP65 Green LED color: yellow diffused Red LED color: clear red White/ LED color: yellow clear Yellow 27 o12 A2 Series Miniature Control Units Maintenance Parts Shape Specification Marking Plate Type No. Ordering Type No. Round AL2M-W AL2M-WPN05 Square AL2Q-W AL2Q-WPN05 Rectangular AL2H-W AL2H-WPN05 Round AL2M-LK1- AL2M-LK1-PN02 Square AL2Q-LK1- AL2Q-LK1-PN02 Rectangular AL2H-LK1- AL2H-LK1-PN02 Round AL2M-LK2- AL2M-LK2- Square AL2Q-LK2- AL2Q-LK2- Lens Unit For IP40 units For IP65 illuminated pushbuttons Rectangular AL2H-LK2- AL2H-LK2- Round AL2M-LK3- AL2M-LK3- Square AL2Q-LK3- AL2Q-LK3- Rectangular AL2H-LK3- AL2H-LK3- Package Quantity 5 * White 2 * Specify a color code in place of in the Type No. A (amber) G (green) R (red) W (white) Y (yellow) 1 For IP65 pilot lights Button Unit For IP40 pushbuttons For IP65 pushbuttons Round AB2M-BK1- AB2M-BK1-PN02 Square AB2Q-BK1- AB2Q-BK1-PN02 Rectangular AB2H-BK1- AB2H-BK1-PN02 Round AB2M-BK2- AB2M-BK2- Square AB2Q-BK2- AB2Q-BK2- Rectangular AB2H-BK2- AB2H-BK2- Color Code * Specify a color code in place of in the Type No. B (black) G (green) R (red) S (blue) W (white) Y (yellow) 2 1 Dimensions * Switch Guard 11 22.5 min. 19.5 22.5 min. Rubber Gasket 12.5 Panel Thickness 0.5 to 5 26.5 18 11 8.5 15 min. Rubber Gasket 12.5 19 min. * Socket (AL-C2, AL-C2V, AL-C2 ) 6 1 33 6 1 6.5 13 2.8 17 Solder Terminal Type (AL-C2) 1 NC1 NC2 17 4.5 8-1.0 +0.2 0 C1 C2 Lamp Terminal (-) Holes Panel Cut-out Bottom View PC Board Terminal (AL-C2V) 6 NO1 NO2 36 1 6 20 Solder Terminal Type with Built-in Resistor (AL-C2 c ) 2.8 2.8 10.2 5.3 4.9 6.5 7.3 13 2.8 5.5 7 10.5 6.5 7.3 2.8 36 Lamp Terminal (+) (TOP) 10.5 10.5 2.8 2.8 33 Terminal Arrangement Terminal 0.8 x 0.3t 2.8 19.5 For Rectangular Units (AL-KH2) Panel Thickness 0.5 to 5 26.5 14 8.5 For Round/Square Units (AL-K2) 3.5 20 5 PC Board Terminal Type with Built-in Resistor (AL-C2 c V) 8-1.0 +0.2 0 Holes Panel Cut-out Bottom View All dimensions in mm. 28 (06/11/10) A2 Series Miniature Control Units o12 Dimensions * Terminal Cover (AL-V2) o12.8 17.3 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. 33.5 * Dust Cover For Square Units (AL-DQ2) For Rectangular Units (AL-DH2) c 20 24 20 o20 o12 12 (Rectangular Units) Waterproof Gasket for Dust Cover o12 20 min. 6.5 Waterproof Gasket for Dust Cover 0.3 6.5 Waterproof Gasket for Dust Cover 0.3 12 12 20 min. 6.5 0.3 Mounting Hole Centers (Round Units, Square Units) 20 min. For Round Units (AL-D2) 24 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. (06/11/10) 29 o12 A2 Series Miniature Control Units Safety Precautions * Turn off the power to A series control units before starting installation, removal, wiring, maintenance, and inspection of the control units. Failure to turn power off may cause electrical shocks or fire hazard. * To avoid burning your hand, use the lamp holder tool when replacing lamps. * For wiring, use wires of a proper gauge to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions Replacement of Lens and Marking Plate Wiring * Removal Solder the terminal at 350C within 3 seconds using a 60W soldering iron. Sn-Ag-Cu type is recommended when using leadfree solder. When soldering, do not touch the control unit with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use non-corrosive rosin flux. Remove the lens assembly (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the Lens Removal Tool (MT-101) and pulling it out. Remove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. Latches Installing the Socket Install the socket on the control unit with the TOP markings on the control unit and the socket placed in the same direction. Engraving Area Color Lens Marking Plate Operating Voltage of LED Lamps Lens Holder * Installation Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. * Installing Non-illuminated Button Non-illuminated pushbuttons contain a marking plate like illuminated units. Be sure to install the marking plate when replacing the button. Replacing the LED Lamp * Removal Use the lamp holder tool (OR-66) to remove lamps. Do not use pliers. * Installation Use the lamp holder tool (OR-66) to install lamps. Note the correct side of the tool for removal or installation. Lamp Holder Tool OR-66 (o8, o10, o12 series) For removing lamps For installing lamps The operating voltage is measured at complete DC. When using a pulsating voltage such as a full-wave rectification voltage, keep peak currents within the forward current If. Peak currents exceeding the If may shorten the LED lamp life. Other Notes * Close Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the control units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. * Replacement of Buttons (Illuminated/Non-illuminated) Do not replace buttons of maintained action units while the button is in the locked position. Replacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. * Operating and Storage Environment 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed type units (IP40) in an environment subject to oil, water or dust accumulation. In such an area, use the waterproof/oiltight units (IP65). * Microswitch Contacts Do not connect NO and NC contacts of the microswitch to different voltages or different power sources to prevent a dead short-circuit. Panel Mounting * IP65 Type Units When mounting the control units onto a panel, use the optional locking ring wrench (MT-002) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.78 N*m. Excessive tightening will damage the locking ring. IP65 type units are evaluated by conventional cutting and cooling oils, and can not be used with some special oils. Contact IDEC for resistance against special oils. 30 (06/11/10) A1 Series Miniature Control Units o10 Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. * * * * Bright and clear LED illumination. 10-mm mounting holes All series have terminals on the same plane. UL recognized, CSA certified Contact Ratings (Contact Block) Specifications Rated Insulation Voltage 250V Operating Temperature -25 to +55C (no freezing) Rated Thermal Current 3A Operating Humidity 45 to 85% RH (no condensation) Operating Voltage (AC/DC) AC 50/60 Hz DC 24V 110V 220V Contact Resistance 50 m maximum (initial value) Insulation Resistance 100 M minimum (500V DC megger) Resistive Load - 1.0A 0.5A Inductive Load - 0.7A 0.5A Resistive Load 1.0A 0.2A - 0.7A 0.1A - Inductive Load Contact Material Dielectric Strength Silver * Minimum applicable load: 5V AC/DC, 3 mA (applicable range may vary with operating conditions and load types) Weight AL1M-M11: 3g Weight (approx.) AL1M-P1: 3g AB1M-M1: 3g Switch Unit Between live and dead metal parts: 2,000V AC, 1 minute Between terminals of different poles: 2,000V AC, 1 minute Between terminals of the same pole: 1,000V AC, 1 minute Between contact and lamp terminals: 1,500V AC, 1 minute Illumination Unit Between live part and ground: 2,000V AC, 1 minute Vibration Resistance Operating extremes: 5 to 55 Hz, amplitude 0.75 mm Shock Resistance Damage limits: 500 m/s2 (50G) Operating extremes: 200 m/s2 (20G) Mechanical Durability (minimum operations) Momentary: 200,000 operations Maintained: 100,000 operations Electrical Durability (minimum operations) Momentary: 100,000 operations Maintained: 50,000 operations (Switching frequency 1200 operations/h) Degree of Protection Enclosed (IP40) LED Lamp Ratings (LAD-S Type) Type No. LAD-SA Lamp Base LAD-SG LAD-SR LAD-SY Exclusive for A series control units Forward Current (If) 20 mA Forward Voltage (Vf) (nominal) 2.2V 2.1V 1.7V Reverse Voltage (Vr) 2.2V 4V Illumination Color A G R Y LED Lamp Color Amber Clear Yellow Diffused Red Clear Yellow Clear Amber Green Red Yellow and White Applicable Lens Color Base Plastic Color Red LED Lamp Life (reference value) Approx. 50,000 hours (The illuminance reduces to 50% the initial intensity when used on complete DC.) Operating Voltage & External Current-limiting Resistor (recommended value) (Note) Internal Circuit 5V DC: 6V DC: 12V DC: 24V DC: 150, 1/2W 200, 1/2W 510, 1W 1.1 k, 1W (+) (-) Note: When LED lamps are used on voltages other than the above, external resistor value R is determined by the following formula: R = (operating voltage - Vf) / If * LED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage must be provided. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. Because (+) no protection diode is contained, ensure the correct polarity is observed. Current Limiting Resistor (06/11/10) (-) Lamp Terminal (+) Lamp Terminal (-) 31 o10 A1 Series Miniature Control Units AL1 LED Illuminated Pushbuttons & Pilot Lights Type No. Operation Type Shape Round AL1M Marking plate size: o8.5 mm Engraving area: o7 mm (Depth: 0.5 mm max.) Square AL1Q Marking plate size: 8.5 mm Engraving area: 7 mm (Depth: 0.5 mm max.) Rectangular AL1H Lens Color Code IP40 Momentary SPDT AL1M-M11 Maintained SPDT AL1M-A11 Pilot Light -- AL1M-P1 Momentary SPDT AL1Q-M11 Maintained SPDT AL1Q-A11 Pilot Light Marking plate size: 8.5 x 12.5 mm Engraving area: 7 x 11 mm (Depth: 0.5 mm max.) Contact -- AL1Q-P1 SPDT AL1H-M11 Maintained SPDT AL1H-A11 Pilot Light -- AL1H-P1 (External Resistor Recommended Value) A: G: Specify a color code in R: place of in the Type W/Y: No. A: G: R: W: Y: Momentary LED Lamp Type No., Rated Current amber green red white yellow LAD-SA LAD-SG LAD-SR LAD-SY Rated Current: 20 mA 5V DC: 6V DC: 12V DC: 24V DC: * LED lamps do not have a current-limiting resistor. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. * AP1M series pilot lights (round bezel only) with built-in current-limiting resistor are also available. 150, 1/2W 200, 1/2W 510, 1W 1.1 k, 1W LED Lamp Internal Circuit (+) (-) Dimensions Panel Thickness 0.5 to 6 Rectangular (TOP) 2.8 Locking Ring Square (TOP) Round (TOP) c12 o12 2.8 12 Terminal Width 1.8x0.4t o12 6 5.5 5.5 22 16 9 Terminal Arrangement (bottom view) Mounting Hole Layout * Round/Square Units (TOP) o10 * Rectangular Units +0.2 0 o10 +0.2 0 Lamp Terminal (+) COM Lamp Terminal (-) 12 min. NO 12 min. NC 12 min. 16 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 32 (06/11/10) A1 Series Miniature Control Units o10 AB1 Pushbuttons Shape Button Type Round AB1M Type No. IP40 Operation Type Contact Momentary SPDT AB1M-M1 Maintained SPDT AB1M-A1 Momentary SPDT AB1M-M1L Maintained SPDT AB1M-A1L Momentary SPDT AB1Q-M1 Maintained SPDT AB1Q-A1 Momentary SPDT AB1Q-M1L Maintained SPDT AB1Q-A1L Momentary SPDT AB1H-M1 Maintained SPDT AB1H-A1 Momentary SPDT AB1H-M1L Maintained SPDT AB1H-A1L Button Illumination Lens Square AB1Q Button Illumination Lens Rectangular AB1H Button Illumination Lens Color Code B G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow B G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow B G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow * Specify a color code in place of or in the Type No. Dimensions Panel Thickness 0.5 to 6 2.8 Locking Ring Rectangular (TOP) Square (TOP) Round (TOP) c12 o12 2.8 12 Terminal Width 1.8x0.4t 6 5.5 5.5 22 16 9 Terminal Arrangement (bottom view) Mounting Hole Layout * Round/Square Units (TOP) o10 * Rectangular Units +0.2 0 o10 +0.2 0 COM 12 min. NO 12 min. NC 12 min. 16 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. (06/11/10) 33 o10 A1 Series Miniature Control Units Accessories Shape Material Type No. Ordering Type No. Package Quantity Locking Ring Wrench o12 Dimensions (mm) Metal (nickel-plated brass) MT-003 MT-003 1 * Used to tighten the locking ring when installing the A1 control units into a panel. * Tighten the locking ring to a torque of 0.29 N*m maximum. Stainless Steel MT-101 MT-101 1 * Used to remove lens and button. Rubber OR-66 OR-66 1 * Used to remove and install LED lamps. AL-K1 AL-K1 1 AL-KH1 1 60 Lens Removal Tool 60 Lamp Holder Tool 70 Switch Guard For round/ square Unit 90 open For rectangular AL-KH1 unit * Used to protect pushbuttons from inadvertent operation. * See page 35 for dimensions. (remains 90 open) Socket Solder Terminal AL-C1 AL-C1 1 PC Board Terminal AL-C1V AL-C1V 1 * Snaps on the rear of the A1 series control units. (see page 35 for dimensions) Terminal Cover Nylon AL-V1 AL-V1PN10 10 * Degree of protection: IP65 AL-B1 Illumination color: amber LAD-SA Illumination color: green LAD-SG Illumination color: red LAD-SR Illumination color: yellow LAD-SY AL-B1PN05 5 o12 4.4 Nitryl rubber (black) 2 Mounting Hole Plug * When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. * Terminal cover is not attached and must be ordered separately. 5.3 9.0 o4.0 Current-limiting resistor is not contained. All dimensions in mm. 34 LAD-SA 1 LAD-SAPN10 10 LAD-SG 1 LAD-SGPN10 10 LAD-SR 1 LAD-SRPN10 10 LAD-SY 1 LAD-SYPN10 10 Amber LED color: amber clear Lens color LED Lamp Green LED color: yellow diffused Red LED color: clear red White/ LED color: yellow clear Yellow (06/11/10) A1 Series Miniature Control Units o10 Maintenance Parts Shape Marking Plate Lens Unit Type No. Package Quantity Ordering Type No. Round AL1M-W AL1M-WPN05 Square AL1Q-W AL1Q-WPN05 Rectangular AL1H-W AL1H-WPN05 Round AL1M-LK1- AL1M-LK1-PN02 Square AL1Q-LK1- AL1Q-LK1-PN02 Rectangular AL1H-LK1- AL1H-LK1-PN02 Round AB1M-BK1- AB1M-BK1-PN02 Square AB1Q-BK1- AB1Q-BK1-PN02 Rectangular AB1H-BK1- AB1H-BK1-PN02 5 Color Code * White Specify a color code in place of in the Type No. A (amber), G (green), R (red) W (white), Y (yellow) 2 Button Unit Specify a color code in place of in the Type No. B (black), G (green), R (red) S (blue), W (white), Y (yellow) Dimensions * Switch Guard For Round/Square Units (AL-K1) For Rectangular Units (AL-KH1) 10 20.5 min. 17.5 20.5 min. Panel Thickness 0.5 to 5 24.5 7.5 10 16 7.5 17.5 12 13 min. 12.5 17 min. * Socket (AL-C1, AL-C1V) Terminal 0.8 x 0.3t 33 Terminal Arrangement (TOP) 7.3 2.8 7.3 2.8 33 NC 5 11 17 2.8 17 2.8 NO 3 5-1.0 Solder Terminal (AL-C1) PC Board Terminal (AL-C1V) +0.2 0 Holes Lamp Terminal (+) (PC Board Terminal Mounting Hole Layout) COM Lamp Terminal (-) (Bottom View) * Terminal Cover o10.8 17.3 33.5 (06/11/10) Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. All dimensions in mm. 35 o10 A1 Series Miniature Control Units Safety Precautions * Turn off the power to A series control units before starting installation, removal, wiring, maintenance, and inspection of the control units. Failure to turn power off may cause electrical shocks or fire hazard. * To avoid burning your hand, use the lamp holder tool when replacing lamps. * For wiring, use wires of a proper gauge to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions Replacement of Lens and Marking Plate Wiring * Removal Solder the terminal at 350C within 3 seconds using a 60W soldering iron. Sn-Ag-Cu type is recommended when using leadfree solder. When soldering, do not touch the control unit with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use non-corrosive rosin flux. Remove the lens assembly (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the Lens Removal Tool (MT-101) and pulling it out. Remove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. Latches Installing the Socket Install the socket on the control unit with the TOP markings on the control unit and the socket placed in the same direction. Color lens Engraving Area Marking Plate Spring Lens Retaining Holder Groove Spring Note: Make sure that the spring is inserted in the correct direction. The base of spring must fit the groove in the holder. * Installation Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. * Installing Non-illuminated Button Non-illuminated pushbuttons contain a marking plate like illuminated units. Be sure to install the marking plate when replacing the button. Replacing the LED Lamp * Removal Use the lamp holder tool (OR-66) to remove lamps. Do not use pliers. * Installation Use the lamp holder tool (OR-66) to install lamps. Note the correct side of the tool for removal or installation. Lamp Holder Tool OR-66 (o8, o10, o12 series) For removing lamps Operating Voltage of LED Lamps The operating voltage is measured at complete DC. When using a pulsating voltage such as a full-wave rectification voltage, keep peak currents within the forward current If. Peak currents exceeding the If may shorten the LED lamp life. Other Notes * Close Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the control units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. * Replacement of Buttons (Illuminated/Non-illuminated) Do not replace buttons of maintained action units while the button is in the locked position. Replacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. * Operating and Storage Environment 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed type units in an environment subject to oil, water or dust accumulation. * Microswitch Contacts Do not connect NO and NC contacts of the microswitch to different voltages or different power sources to prevent a dead short-circuit. For installing lamps Panel Mounting When mounting the control units into a panel, use the optional locking ring wrench (MT-003) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.29 N*m. Excessive tightening will damage the locking ring. 36 (06/11/10) A8 Series Miniature Control Units o8 Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. * * * * Bright and clear LED illumination. 8-mm mounting holes All series have terminals on the same plane. UL recognized, CSA certified Contact Ratings (Contact Block) Rated Insulation Voltage 250V Rated Thermal Current 3A Operating Voltage (AC/DC) AC 50/60 Hz DC Specifications 24V 110V 220V Resistive Load - 1.0A 0.5A Inductive Load - 0.7A 0.5A Resistive Load 1.0A 0.2A - Inductive Load 0.7A 0.1A - Contact Material Operating Temperature Operating Humidity Contact Resistance Insulation Resistance Dielectric Strength Silver * Minimum applicable load: 5V AC/DC, 3 mA (applicable range may vary with operating conditions and load types) Switch Unit Illumination Unit Weight Vibration Resistance AL8M-M11: 2g Weight (approx.) -25 to +55C (no freezing) 45 to 85% RH (no condensation) 50 m maximum (initial value) 100 M minimum (500V DC megger) Between live and dead metal parts 2,000V AC, 1 minute Between terminals of different poles: 2,000V AC, 1 minute Between terminals of the same pole: 1,000V AC, 1 minute Between contact and lamp terminals: 1,500V AC, 1 minute Between live part and ground: 2,000V AC, 1 minute Operating extremes: 5 to 55 Hz, amplitude 0.75 mm Damage limits: 500 m/s2 (50G) Operating extremes: 200 m/s2 (20G) Momentary: 200,000 operations Maintained: 100,000 operations Momentary: 100,000 operations Maintained: 50,000 operations (Switching frequency 1200 operations/h) Enclosed (IP40) AL8M-P1: Shock Resistance 2g Mechanical Durability (minimum operations) AB8M-M1: 2g Electrical Durability (minimum operations) Degree of Protection LED Lamp Ratings (LAD-S Type) Type No. LAD-SA Lamp Base LAD-SG LAD-SR LAD-SY Exclusive for A series control units Forward Current (If) 20 mA Forward Voltage (Vf) (nominal) 2.2V 2.1V 1.7V Reverse Voltage (Vr) 2.2V 4V Illumination Color A G R Y LED Lamp Color Amber Clear Yellow Diffused Red Clear Yellow Clear Amber Green Red Yellow and White Applicable Lens Color Base Plastic Color Red LED Lamp Life (reference value) Approx. 50,000 hours (The illuminance reduces to 50% the initial intensity when used on complete DC.) Operating Voltage & External Current-limiting Resistor (recommended value) (Note) Internal Circuit 5V DC: 6V DC: 12V DC: 24V DC: 150, 1/2W 200, 1/2W 510, 1W 1.1 k, 1W (+) (-) Note: When LED lamps are used on voltages other than the above, external resistor value R is determined by the following formula: R = (operating voltage - Vf) / If * LED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage must be provided. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. Because no protection (+) diode is contained, ensure the correct polarity is observed. Current Limiting Resistor (06/11/10) (-) Lamp Terminal (+) Lamp Terminal (-) 37 o8 A8 Series Miniature Control Units AL8 LED Illuminated Pushbuttons & Pilot Lights Type No. Operation Type Shape Round AL8M Marking plate size: o6 mm Engraving area: o4.5 mm (Depth: 0.5 mm max.) Square AL8Q Marking plate size: 6 mm Engraving area: 4.5 mm (Depth: 0.5 mm max.) Rectangular AL8H Marking plate size: 6 x 9 mm Engraving area: 4.5 x 7.5 mm (Depth: 0.5 mm max.) Contact IP40 Momentary SPDT AL8M-M11 Maintained SPDT AL8M-A11 Pilot Light -- AL8M-P1 Momentary SPDT AL8Q-M11 Maintained SPDT AL8Q-A11 Pilot Light -- AL8Q-P1 Momentary SPDT AL8H-M11 Maintained SPDT AL8H-A11 Pilot Light -- AL8H-P1 LED Lamp Lens Color Code Specify a color code in place of in the Type No. A: amber G: green R: red W: white Y: yellow * LED lamps do not have a current-limiting resistor. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. * AP8M series pilot lights (round bezel only) with built-in current-limiting resistor are also available. Type No., Rated Current (External Resistor Recommended Value) A: G: R: W/Y: LAD-SA LAD-SG LAD-SR LAD-SY Rated Current: 20 mA 5V DC: 6V DC: 12V DC: 24V DC: 150, 1/2W 200, 1/2W 510, 1W 1.1 k, 1W LED Lamp Internal Circuit (+) (-) Dimensions Panel Thickness 0.5 to 6 Rectangular (TOP) Locking Ring Square (TOP) Round (TOP) c9 o9 2.5 9 2.5 Terminal Width 1.8 x 0.4t o9 5 5.5 7 5.5 22 Terminal Arrangement 12 9 Mounting Hole Layout * Round/Square Units (TOP) o8 Lamp Terminal (+) Lamp Terminal (-) o8 +0.2 0 9 min. NO COM 9 min. NC * Rectangular Units +0.2 0 9 min. Note: Determine mounting centers to ensure easy operation. 38 12 min. All dimensions in mm. (06/11/10) A8 Series Miniature Control Units o8 AB8 Pushbuttons Shape Button Type Type No. IP40 Operation Type Contact Momentary SPDT AB8M-M1 Maintained SPDT AB8M-A1 Momentary SPDT AB8M-M1L Maintained SPDT AB8M-A1L Momentary SPDT AB8Q-M1 Maintained SPDT AB8Q-A1 Momentary SPDT AB8Q-M1L Maintained SPDT AB8Q-A1L Momentary SPDT AB8H-M1 Maintained SPDT AB8H-A1 Momentary SPDT AB8H-M1L Maintained SPDT AB8H-A1L Rectangular (TOP) Square (TOP) Round (TOP) c9 o9 Round AB8M Color Code Button Illumination Lens Square AB8Q Button Illumination Lens Rectangular AB8H Button Illumination Lens B G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow B G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow B G: R: S: W: Y: black green red blue white yellow A: G: R: W: Y: amber green red white yellow * Specify a color code in place of or in the Type No. Dimensions Panel Thickness 0.5 to 6 Locking Ring 2.5 9 2.5 Terminal Width 1.8 x 0.4t 5.5 7 5.5 22 12 9 Terminal Arrangement (bottom view) Mounting Hole Layout * Round/Square Units (TOP) o8 * Rectangular Units +0.2 0 o8 +0.2 0 9 min. NO COM 9 min. NC 9 min. 12 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. (06/11/10) 39 o8 A8 Series Miniature Control Units Accessories Shape Material Type No. Ordering Type No. Package Quantity Dimensions (mm) Locking Ring Wrench o9 Metal (nickel-plated brass) MT-004 MT-004 1 * Used to tighten the locking ring when installing the A8 series control units into a panel. * Tighten the locking ring to a torque of 0.29 N*m maximum. Stainless Steel MT-101 MT-101 1 * Used to remove the lens and button. Rubber OR-66 OR-66 1 * Used to remove and install the LED lamps. AL-K8 AL-K8 1 AL-KH8 1 60 Lens Removal Tool 60 Lamp Holder Tool 70 Switch Guard For round/ square Unit 90 open For rectangular AL-KH8 unit * Used to protect pushbuttons from inadvertent operation. * See page 41 for dimensions. (remains 90 open) Socket Solder Terminal AL-C8 AL-C8 1 PC Board Terminal AL-C8V AL-C8V 1 Terminal Cover * Snaps on the rear of the A8 series control units. (see page 41 for dimensions) Nylon AL-V8 AL-V8PN10 10 * When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. * Terminal cover is not attached and must be ordered separately. Nitryl rubber (black) AL-B8 AL-B8PN05 5 * Degree of protection: IP65 Illumination color: amber LAD-SA Illumination color: green LAD-SG Illumination color: red LAD-SR Illumination color: yellow LAD-SY Mounting Hole Plug 5.3 9.0 o4.0 Current-limiting resistor is not contained. All dimensions in mm. 40 LAD-SA 1 LAD-SAPN10 10 LAD-SG 1 LAD-SGPN10 10 LAD-SR 1 LAD-SRPN10 10 LAD-SY 1 LAD-SYPN10 10 Amber LED color: amber clear Lens color LED Lamp Green LED color: yellow diffused Red LED color: clear red White/ LED color: yellow clear Yellow (06/11/10) A8 Series Miniature Control Units o8 Maintenance Parts Shape Marking Plate Lens Unit Type No. Package Quantity Ordering Type No. Round AL8M-W AL8M-WPN05 Square AL8Q-W AL8Q-WPN05 Rectangular AL8H-W AL8H-WPN05 Round AL8M-LK1- AL8M-LK1-PN02 Square AL8Q-LK1- AL8Q-LK1-PN02 Rectangular AL8H-LK1- AL8H-LK1-PN02 Round AB8M-BK1- AB8M-BK1-PN02 Square AB8Q-BK1- AB8Q-BK1-PN02 Rectangular AB8H-BK1- AB8H-BK1-PN02 5 Color Code * White Specify a color code in place of in the Type No. A (amber), G (green), R (red) W (white), Y (yellow) 2 Button Unit Specify a color code in place of in the Type No. B (black), G (green), R (red) S (blue), W (white), Y (yellow) Dimensions * Switch Guard For Round/Square Units (AL-K8) For Rectangular Units (AL-KH8) Panel Thickness 0.5 to 5 8.5 17.5 min. 14.5 17.5 min. 6 8.5 6 14.5 21.5 12 10 12.5 13 min. 11 min. * Socket (AL-C8, AL-C8V) Terminal 0.8 x 0.3t Terminal Arrangement (TOP) 6.3 2.5 33 6.3 2.5 33 NC 5 8.8 Solder Terminal (AL-C8) 17 3 PC Board Terminal (AL-C8V) 2.5 17 2.5 NO 5-1.0 +0.2 0 Holes Lamp Terminal (+) (PC Board Terminal Mounting Hole Layout) COM Lamp Terminal (-) (Bottom View) * Terminal Cover (AL-V8) o9.1 17.3 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. 33.5 All dimensions in mm. (06/11/10) 41 o8 A8 Series Miniature Control Units Safety Precautions * Turn off the power to A series control units before starting installation, removal, wiring, maintenance, and inspection of the control units. Failure to turn power off may cause electrical shocks or fire hazard. * To avoid burning your hand, use the lamp holder tool when replacing lamps. * For wiring, use wires of a proper size to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions Replacement of Lens and Marking Plate Panel Mounting * Removal When mounting the control units onto a panel, use the optional locking ring wrench (MT-004) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.29 N*m. Excessive tightening will damage the locking ring. Remove the operator (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the Lens Removal Tool (MT-101) and pulling it out. Remove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. Latches Color lens Engraving Area Marking Plate Spring Lens Retaining Holder Groove Spring * Note: Make sure that the spring is inserted in the correct direction. The base of spring must fit the groove in the holder. Wiring Solder the terminal at 350C within 3 seconds using a 60W soldering iron. Sn-Ag-Cu type is recommended when using leadfree solder. When soldering, do not touch the enabling switch with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use a non-corrosive rosin flux. Installing the Socket Install the socket on the control unit with the TOP markings on the control unit and the socket placed in the same direction. Operating Voltage of LED Lamps Installation Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. * Installing Non-illuminated Button Non-illuminated pushbuttons contain a marking plate like illuminated units. Be sure to install the marking plate when replacing the button. Replacing the LED Lamp * Removal Use the lamp holder tool (OR-66) to remove lamps. Do not use pliers. * Installation Use the lamp holder tool (OR-66) to install lamps. Note the correct side of the tool for removal or installation. The operating voltage of 5V DC is measured at complete DC. When using a pulsating voltage such as a full-wave rectification voltage, keep peak currents within the forward current If. Peak currents exceeding the If may shorten the LED lamp life. Other Notes * Close Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the control units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. * Replacement of Buttons (Illuminated/Non-illuminated) Do not replace buttons of maintained action units while the button is in the locked position. Replacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. * Operating and Storage Environment Lamp Holder Tool OR-66 (o8, o10, o12 series) For removing lamps For installing lamps 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed type units in an environment subject to oil, water or dust accumulation. * Microswitch Contacts Do not connect NO and NC contacts of the microswitch to different voltages or different power sources to prevent a dead short-circuit. 42 (06/11/10) A Series Miniature Control Units (06/11/10) 43 Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 E-mail: products@idec.co.jp IDEC CORPORATION (USA) 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Fax: +1-408-744-9055 / (800) 635-6246 E-mail: opencontact@idec.com IDEC CANADA LIMITED Unit 22-151, Brunel Road Mississauga, Ontario, L4Z 1X3, Canada Tel: +1-905-890-8561, Toll Free: (888) 317-4332 Fax: +1-905-890-8562 E-mail: sales@ca.idec.com IDEC AUSTRALIA PTY. LTD. 2/3 Macro Court, Rowville, Victoria 3178, Australia Tel: +61-3-9763-3244, Toll Free: 1800-68-4332 Fax: +61-3-9763-3255 E-mail: sales@au.idec.com IDEC ELECTRONICS LIMITED www.idec.com Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire RG24 8WA, UK Tel: +44-1256-321000, Fax: +44-1256-327755 E-mail: sales@uk.idec.com IDEC ELEKTROTECHNIK GmbH IDEC IZUMI (H.K.) CO., LTD. Wendenstrasse 331, 20537 Hamburg, Germany Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24 E-mail: service@idec.de Unit 1505-07, DCH Commercial Centre No. 25, Westlands Road, Quarry Bay, Hong Kong Tel: +852-2803-8989, Fax: +852-2565-0171 E-mail: info@hk.idec.com IDEC (SHANGHAI) CORPORATION Room 608-609, 6F, Gangtai Plaza, No. 700, Yan'an East Road, Shanghai 200001, P.R.C. Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 E-mail: idec@cn.idec.com IDEC (SHANGHAI) CORPORATION IDEC TAIWAN CORPORATION 8F-1, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 E-mail: service@idectwn.com.tw Beijing Office IDEC IZUMI ASIA PTE. LTD. Unit 1002, No. 10 Kuntai Building, Zhaowai Dajie, Zhao Yang District, Beijing, 100020, P.R.C. Tel: +86-10-6599-5541, Fax: +86-10-6599-5540 No. 31, Tannery Lane #05-01, Dragon Land Building, Singapore 347788 Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: info@sg.idec.com IDEC (SHENZHEN) CORPORATION Unit AB-3B2, Tian Xiang Building, Tian'an Cyber Park, Fu Tian District, Shenzhen, Guang Dong 518040, P.R.C. Tel: +86-755-8356-2977, Fax: +86-755-8356-2944 Cat. No. EP1149-0 OCTOBER 2006 14.1DNP PRINTED(06/11/10) IN JAPAN