http://www.tracopower.com Page 1 of 5
Metal Case Power Supplies
TXH Series, 120 –480 Watt
Features
Compact U-bracket and enclosed power
supplies
Screw terminal block
Very high efficiency up to 93 %
No internal fan for 120 W & 240 W
models.
Universal input 90 – 264 VAC
Adjustable output voltage
EMI/EMC compliance with EN 61000-6-3
and EN 61000-6-1
Compliance to EN 61000-3-2 (PFC)
Short circuit and overvoltage protection
3-year product warranty
UL 60950-1
CB
Scheme
Order code Output power
max.
Output Voltage [VDC] Output current
max.
Efficiency
typ. at 230 VAC
nominal * adjustable
TXH 120-112 12 11.4 – 13.2 10 A 90 %
TXH 120-124 120 Watt 24 22.8 – 26.4 5.0 A 91 %
TXH 120-148 48 45.6 – 52.0 2.5 A 92 %
TXH 240-112 12 11.4 – 12.6 20 A 90 %
TXH 240-124 240 Watt** 24 22.8 – 25.2 10 A 92 %
TXH 240-148 48 45.6 – 50.4 5.0 A 93 %
TXH 360-112 12 10.8 – 13.2 30 A 89 %
TXH 360-124 360 Watt 24 21.6 – 26.4 15 A 91 %
TXH 360-148 48 44.0 – 51.0 7.5 A 93 %
TXH 480-112 12 10.8 – 13.2 40 A 88 %
TXH 480-124 480 Watt 24 21.6 – 26.4 20 A 90 %
TXH 480-148 48 43.2 – 50.4 10 A 91 %
Models with Single Output
The TXH series is a family of power supplies in metal enclosure, designed for a wide
range of cost critical applications. The very high efficiency of up to 93% admits
of a compact design with free air convection coouling for the 120 and 240 Watt
models. The units are equiped with screw terminal blocks and are easy to install in
any equipment.
These power supplies have universal input and comply with European EMC stan-
dards and the Low Voltage Directive (LVD).
* 36 VDC output voltage models on request.
** at 18 CFM airflow
http://www.tracopower.com Page 2 of 5
Metal Case Power Supplies
TXH Series 120–480 Watt
Input Specifications
Input voltage – nominal 100 – 240 VAC
– AC range (universal input) 90 – 264 VAC
– DC range 120 – 370 VDC
Input frequency 47 – 63 Hz
Earth leakage current (240 VAC / 63 Hz) 360 W models: 300 µA max.
other models: 500 µA max.
Input current at full load – at 115 VAC / 230 VAC 120 W models: 1.2 A typ. / 0.6 A typ.
240 W models: 2.3 A typ. / 1.1 A typ.
360 W models: 3.6 A typ. / 1.8 A typ.
480 W models: 5.1 A typ. / 2.5 A typ.
Recommended circuit breaker 120 W models: 3.15 A
(characteristic C) or slow blow fuse 240 W models: 5 A
360 W models: 6.3 A
480 W models: 10 A
Output Specifications
Voltage set accuracy ±2 % max.
Output voltage adjustment range details see table page 1
Regulation – Input variation 1 % max.
– Load variation (0100%) 1 % max.
Minimum load not required
Ripple and noise (20 MHz bandwidth) [mVp-p] max. Models: 12 VDC 24 VDC 48 VDC
120 W 120 240 480
240 W 120 200 200
360 W 150 200 200
480 W 100 200 300
Hold-up time 10 ms min.
Current limitation 130 - 150 % foldback, auto recovery
Short circuit protection indefinite,
360 & 480 W models: auto recovery
120 & 240 W models: no auto recovery (power disconnect required)
Overvoltage protection by Zener diode 120 % of Vout typ.
360 & 480 W models: auto recovery
120 & 240 W models: no auto recovery (power disconnect required)
Overtemperature protection for 360 & 480 W models only, auto recovery
Capacitive load, [µF] max. Models: 12 VDC 24 VDC 48 VDC
120 W 23‘000 10‘000 470
240 W 23‘000 10‘000 470
360 W 85000 48‘000 13‘000
480 W 180‘000 75000 25‘000
General Specifications
Temperature ranges – Operating 480/360/120 W models: –25°C to +70°C
other models: 10°C to +70°C
– Storage (non operating) 25°C to +85°C
Derating – Ambient temperature all models: 2.5 %/K above +50°C
TXH 480 -122: 2.0 %/K below 5°C
– Low input voltage TXH 480 -122: 0.35 %/V below 180 VAC
other models 1.0 %/V below 100 VAC
Temperature coefficient 0.03 %/K
Humidity (non condensing) 95 % rel max.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com Page 3 of 5
Outline Dimensions
Weight: 390 g (13.8 oz)
137.0
6.0 4.0
100.0
13.0 50.0 13.5
(5.39)
(3.94)
(0.24) (0.16)
(1.97)
(0.53) (0.51)
41.0
(1.50) 38.0
12.0 12.0
60.5
82.0
10.8
(0.47) (0.47)
(1.61)
(3.23)
(0.43)
(2.38)
top view
7x M3 THD
(bottom)
AC IN (L)
AC IN (N)
FG
+Vout
+Vout
–Vout
–Vout
TXH 120 models
General Specifications
Switching frequency (pulse width modulation PWM) 120 & 240 W models: 100 kHz typ.
360 W models: 75 kHz typ.
480 W models: 62.5 kHz typ.
Isolation voltage (60 sec.) – Input / Output 120 & 240 W models: 4‘000 VAC
360 & 480 W models: 3‘000 VAC
– Input / Case 120 & 240 W models: 2‘000 VAC
360 & 480 W models: 1‘500 VAC
– Output / Case 500 VAC
Reliability /calculated MTBF 120, 240 & 360 W models: >120‘000 h
(MIL-HDBK-217F, at +25°C, ground benign) 480 W models: >100’000 h
Electromagnetic compatibility
– Conducted input RI suppression EN 55022, class B, FCC part 15, level B
(EMC), Emissions – Harmonic current emissions
IEC/EN 61000-3-2 class B
Electromagnetic compatibility
EN 55024
(EMC), Immunity
Degree of protection class I
Safety standards UL 60950-1, IEC/EN 60950-1
Safety approvals – UL/cUL 60950 -1 www.ul.com -> certifications -> File e188913
– CB report according to IEC 60950-1 www.tracopower.com/products/txh-cb.pdf
Environment – Vibration 3 axes, sine sweep, 10–500Hz, 2g, 0.1 oct/min
Environmental compliance – Reach www.tracopower.com/products/txh-reach.pdf
– RoHS RoHS directive 2011/65/EU
Altitude during operation 120 / 240 & 360 W models: up to 4‘000 m (13120 ft) approved
480 W models: up to 3‘000 m (9‘840 ft) approved
Optional Cover
TXH 120–COV Cover incl. screws for TXH 120 models
Metal Case Power Supplies
TXH Series 120–480 Watt
Max mounting screw penetration: 2.5 mm (0.1)
http://www.tracopower.com Page 4 of 5
Weight: 750 g (26 oz)
Outline Dimensions
TXH 360 models
Weight: 580 g (20.5 oz)
150.0
127.0
13.0 57.0 11.5
(5.91)
(5.00)
(2.24)
(0.45) (0.51)
53.0 (1.38) 35.0
12.0 12.0
63.5
106.0
21.25
(0.47) (0.47)
(2.09)
(4.17)
(0.83)
(2.50)
top view
7x M3 THD
(bottom)
AC IN (L)
AC IN (N)
PE
+Vout
+Vout
–Vout
–Vout
1
3
4
7
TXH 240 models
Optional Cover
TXH 240–COV Cover incl. screws for TXH 240 models
Metal Case Power Supplies
TXH Series 120–480 Watt
Dimensions in [mm], () = Inch
Tolerances ±0.8 (±0.03)
Mounting hole pich tolerances ±0.5 (±0.02)
Max mounting screw penetration: 2.5 mm (0.10)
Terminal rating: 25A
At higher current connection has to be splitted
Max mounting screw penetration: 2.5 mm (0.10)
Terminal rating: 25A
At higher current connection has to be splitted
Input terminal
1FG
2AC (N)
3AC (L)
Output terminal
4-6 + Vout
7-9 - Vout
Outline Dimensions
Metal Case Power Supplies
TXH Series 120–480 Watt
177.8
202.8
27.44
47.71
30.5
45.0
C 1
C 3
C 5
C 7
C 2
C 4
C 6
C 8
45.0
106.5
Vo A D J .
4
7
5
8
6
9
177.8
24.0
41.25
137.8
106.5
88.7
13.1
75.8
A =F or fixture to din rail clip only
A = M 3x 0. 5P
B =M 3x 0. 5P
B=F or fix ture to pcb/chas sis only
A
A
A
B B
B B
TXH 480 models
Dimensions in [mm], () = Inch
Tolerances ±0.8 (±0.03)
Mounting hole pich tolerances ±0.5 (±0.02)
Input terminal
1AC (N)
2AC (L)
3FG
Output terminal
4-6 + Vout
7-9 - Vout
Control connector
C1 + Sense
C2 - Sense
C3 Remote Control: open = On, short = Off
C4
C5 DC-OK: 4-6 VDC = On, 0-1 VDC = Off
C6 GND
C7 +5 VDC aux. ±10%, 0.6 A max.
C8 GND aux.
Page 5 of 5
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Rev. September 7, 2018
Mating connector:
Housing: JST PHDR-08VS
Crimp: JST SPHD-002T-P0.5
Connection cable with 500mm
flying leads included!
Max mounting screw penetration: 2.5 mm (0.10)
Terminal rating: 25A
At higher current connection has to be splitted
Weight: 1050 g (37 oz)