TDK-Lambda ZWQ80/A SPECIFICATIONS (CONVECTION COOLING) A190-01-01/A-D MODEL ZWQ80-5225/A ITEMS ZWQ80-5222/A ZWQ80-5224/A V1 V2 V3 V4 V1 V2 V3 V4 V1 V2 V3 V4 V +5 +12 -12 +5 +5 +12 -12 +12 +5 +12 -12 +24 0 1 Nominal Output Voltage 2 Minimum Output Current (Convection) (*1) A 0.9 0 0 0 0.9 0 0 0 0.9 0 0 3 Minimum Output Current (Peak Application) (*1) A 1.4 0 0 0 1.4 0 0 0 1.4 0 0 0 4 Maximum Output Current A 8.0 2.0 2.0 7.0 8.0 2.0 2.0 3.0 8.0 2.0 2.0 1.5 5 Total Allowable Output Power (*15) W 6 Maximum Peak Output Current (*16) 10.0 2.5 2.5 9.0 10.0 2.5 2.5 4.0 10.0 2.5 2.5 2.0 7 Total Allowable Peak Output Power (*15) W 8 Efficiency (Typ) (*2) % 9 Input Voltage Range (*3) - 10 Input Current (100/200VAC) (Typ) (*2) A 1.2 / 0.6 11 Inrush Current (Typ) (*4) - 14A at 100VAC, 28A at 200VAC, Ta=25 C, Cold Start Designed to meet IEC61000-3-2 12 PFHC A 80 80 104 104 (*2) 72 o - 14 Output Voltage Range V 15 Output Voltage Accuracy - 104 85 - 265VAC (47 - 63Hz) or 120 - 370VDC - 13 Power Factor (100/200VAC) (Typ) 80 0.99 / 0.93 5.0-5.25 +12/+15 -12/-15 2.0-5.25 5.0-5.25 +12/+15 -12/-15 11.4-12.6 5.0-5.25 +12/+15 -12/-15 22.8-25.2 - +5% +5% - - +5% +5% - - +5% +5% - 0 < Ta < +50oC mV 120 150 150 120 120 150 150 150 120 150 150 200 (*5) -10 < Ta < 0oC mV 160 180 180 160 160 180 180 180 160 180 180 200 17 Maximum Line Regulation (*5,6) mV 20 48 48 20 20 48 48 48 20 48 48 96 18 Maximum Load Regulation (*5,7) mV 100 300 300 100 100 300 300 300 100 300 300 400 16 Maximum Ripple & Noise 19 Temperature Coefficient Less than 0.02% /oC More than 109.2W of Total Output Power - 20 Over Current Protection (*8) 21 Over Voltage Protection (*9) V - 5.7 - 7.0 16.5-22.5 16.5-22.5 5.7 - 7.0 5.7 - 7.0 16.5-22.5 16.5-22.5 13.8-16.2 5.7 - 7.0 16.5-22.5 16.5-22.5 27.6-32.4 22 Hold-Up Time (Typ) (*10) - 20 ms 23 Leakage Current (*11) - 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC - 25 Parallel Operation - - 26 Series Operation - - - -10 - +50 C (-10 - +30 C : 100%, +50 C : 50%) 30 - 90%RH (No Dewdrop) 24 Remote ON/OFF Control 27 Operating Temperature (*12) 28 Operating Humidity - 29 Storage Temperature - 30 Storage Humidity - 31 Cooling - 32 Withstand Voltage o o o -30 - +85oC 10 - 95%RH (No Dewdrop) Convection Cooling Input - FG : 2kVAC(20mA), Input - Output : 3kVAC (20mA) Output - FG : 500VAC(100mA), for 1min. 33 Isolation Resistance - 34 Vibration - More than 100MW at 25oC and 70%RH Output - FG : 500VDC At no operating, 10-55Hz (Sweep for 1min) 19.6 m/s2 Constant, X, Y, Z 1h each. 35 Shock (In package) - 36 Safety (*13) 2 - Less than 196.1 m/s Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1 - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11 Designed to meet DENAN 37 EMI 38 Immunity (*14) 39 Weight (Typ) 40 Size (W x H x D) - 800g mm 97.5 x 44.5 x 225 (Refer to Outline Drawing) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. For V2, V3,V4 stability, require minimum output current of V1. o *2. At 100/200VAC, Ta=25 C and total allowable output power. *3. For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 240VAC(50/60Hz). *4. Not applicable for the inrush current to Noise Filter for less than 0.2ms. *5. Refer to output measuring (A190-01-05/A-_) for line & load regulation and ripple voltage. *6. 85 - 265VAC , constant load. *7. Minimum load - Full load, constant input voltage. *8. Constant current limit with automatic recovery. Refer to test data (A190-53-01_). Not operate at over load or dead short condition for more than 30 seconds. *9. OVP circuit will shut down all outputs, manual reset (Line recycle). *10. At 100/200VAC, nominal output voltage and total allowable output power. *11. Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25oC. *12. At standard mounting. - Load (%) is percent of total allowable output power or each maximum output current, whichever is greater. For other mountings, refer to derating curve (A190-01-03/A-_). *13. As for DENAN, designed to meet at 100VAC. *14. Refer to test data (A190-58-01_). *15. Allowable output power is changed according to V4 voltage(Only ZWQ-5225/A), refer to derating table(A190-01-03/A-_). *16. Operating period at peak current is less than 10sec.. (Duty<0.35) DENSEI-LAMBDA ZWQ80/A SPECIFICATIONS (FORCED AIR COOLING) A190-01-02/A-A MODEL ZWQ80-5225/A ITEMS V ZWQ80-5222/A ZWQ80-5224/A V1 V2 V3 V4 V1 V2 V3 V4 V1 V2 V3 V4 +5 +12 -12 +5 +5 +12 -12 +12 +5 +12 -12 +24 1 Nominal Output Voltage 2 Minimum Output Current (*1) A 1.4 0 0 0 1.4 0 0 0 1.4 0 0 0 3 Maximum Output Current A 10.0 2.5 2.5 9.0 10.0 2.5 2.5 4.0 10.0 2.5 2.5 2.0 4 Total Allowable Output Power (*2) W 5 Input Current (100/200VAC) (Typ (*3) A 1.6 / 0.8 6 Operating Temperature (*4) - -10 ~ +60oC (-10 ~+40oC : 100%, +60oC : 50%) 7 Cooling (*5) - Forced Air Cooling 104 104 *Read instruction manual carefully, before using the power supply unit. =NOTES= *For other items, refer to convection cooling specifications (A190-01-01/A-_). *1. For V2, V3,V4 stability, require minimum output current of V1. When it is using under condition of forced air cooling, V1 minimum output current is same as convection cooling. *2. Allowable output power is changed according to V4 voltage(Only ZWQ-5225/A), refer to derating table (A190-01-04/A-_). *3. At 100/200VAC, Ta=25oC total allowable output power. *4. At standard mounting. - Load (%) is percent of total allowable output power or each maximum output current, whichever is greater. For other mountings, refer to derating curve (A190-01-04/A-_). *5. Air flow > 0.85m3/min(30cfm) 104 DENSEI-LAMBDA ZWQ80/A OUTPUT DERATING (CONVECTION COOLING) A190-01-03/A Allowable output power LOAD (%) o Ta( C) -10 ~+15 20 25 30 35 40 45 50 5225/A MOUNT A MOUNT B,C,D MOUNT E 100 100 100 100 87 75 62 50 100 100 100 87 75 62 50 100 100 87 75 62 50 A 5V 3V 2V 5223/A B C 104W 80W 86W 80W 77W 77W A B C 3.3V 88.7W 80W 3V 2V 86W 80W 77W 77W A : V4 setting voltage B : Total Allowable Peak Output Power C : Total Allowable Output Power * The period of peak current at Convection Cooling is limited less than 10sec.. (Duty< 0.35 For peak current application, refer to note (A190-01-05/A_). OUTPUT DERATING CURVE FOR CONVECTION COOLING 100 LOAD(%) 80 MOUNT A 60 MOUNT B,C,D 40 20 MOUNT E 0 -10 0 10 20 30 40 50 Ta (C) 60 70 Please refer to Instruction manual. * Load (%) is percent of total allowable output power or each maximum output current, whichever is greater. MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E PROHIBIT (STANDARD MOUNTING) x DENSEI-LAMBDA ZWQ80/A OUTPUT DERATING (FORCED AIR COOLING) A190-01-04/A Allowable output power Ta() -10 ~+30 35 40 45 50 55 LOAD (%) MOUNT A,B,C,D,E 100 100 100 87 75 62 60 50 5225/A B A 104W 5V 3V 86W 2V 77W 5223/A B A 3.3V 88.7W 3V 86W 2V 77W A : V4 setting voltage B : Total Allowable Output Power * Air flow > 0.85m 3/min(30cfm) Air must flow through component side. OUTPUT DERATING CURVE FOR CONVECTION COOLING 100 LOAD(%) 80 60 MOUNT A,B,C,D,E 40 20 0 -10 0 10 20 30 40 50 60 70 80 Ta (C) Please refer to Instraction manual. * Load (%) is percent of total allowable output power or each maximum output current, whichever is greater. MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E PROHIBIT (STANDARD MOUNTING) x DENSEI-LAMBDA ZWQ80/A NOTE A190-01-05/A Output Measuring 150mm P.S Measuring Point for Ripple & Noise. Measure with EIAJ RC-9131 probe. Bandwidth of scope : 100MHz AWG18 A V1 + C5 C1 RL1 G1 V2 A C2 C6 + RL2 G2 A C3 C7 V3 V4 + RL3 A C4 C8 C1,C2,C3,C4 C5 C6,C7,C8 : Film Cap. : Elec. Cap. : Elec. Cap. Capacitance 0.1 F 1000 F 100 F + RL4 G3 Measuring Point for Vo and Line/Load Regulation. Peak Output Current (Convection Cooling) Im Ip 0A Ip aA 0A T Iav Im = Im T Ip x Iav Im = (Ip - a ) x +a Ip : Peak output current ( A ) Iav : Average output current ( A ) ( Maximum output current (Convection) in Spec. ) Im : Average output current ( A ) : Pulse width of peak output current ( sec ) ( Operating time at peak output ) T : Period ( sec ) : more than 10ms * The period of peak current at Convection Cooling is limited less than 10sec.. (Duty< 0.35 * Take V1 minmum output current more than 1.4A. TDK-Lambda ZWQ80/A SPECIFICATIONS (CONVECTION COOLING) A190-01-06/A-D MODEL ZWQ80-5223/A ITEMS 1 Nominal Output Voltage V1 V2 V3 V4 V +5 +12 -12 +3.3 0 2 Minimum Output Current (Convection) (*1) A 0.9 0 0 3 Minimum Output Current (Peak Application) (*1) A 1.4 0 0 0 4 Maximum Output Current A 8.0 2.0 2.0 7.0 5 Total Allowable Output Power (*16) W 6 Maximum Peak Output Current (*17) 10.0 2.5 2.5 9.0 7 Total Allowable Peak Output Power (*16) W 8 Efficiency (Typ) (*2) % 9 Input Voltage Range (*3) - 10 Input Current (100/200VAC) (Typ) (*2) A 1.2 / 0.6 11 Inrush Current (Typ) (*4) - 14A at 100VAC, 28A at 200VAC, Ta=25 C, Cold Start Designed to meet IEC61000-3-2 12 PFHC 80 A 88.7 72 85 - 265VAC (47 - 63Hz) or 120 - 370VDC o - 13 Power Factor (100/200VAC) (Typ) (*2) - 0.99 / 0.93 14 Output Voltage Range V 5.0-5.25 +12/+15 -12/-15 15 Output Voltage Accuracy - - +5% +5% - 0 < Ta < +50oC mV 120 150 150 120 (*5) -10 < Ta < 0oC mV 160 180 180 160 17 Maximum Line Regulation (*5,6) mV 20 48 48 20 18 Maximum Load Regulation (*5,7) mV 100 300 300 100 16 Maximum Ripple & Noise 19 Temperature Coefficient Less than 0.02% /oC More than 93.1W of Total Output Power - 20 Over Current Protection (*8) 21 Over Voltage Protection (*9) V 5.7 - 7.0 16.5-22.5 16.5-22.5 22 Hold-Up Time (Typ) (*10) - 20 ms 23 Leakage Current (*11) - 24 Remote ON/OFF Control (*14) 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC Possible 25 Parallel Operation - - 26 Series Operation - - - -10 - +50 C (-10 - +30 C : 100%, +50 C : 50%) 30 - 90%RH (No Dewdrop) 27 Operating Temperature (*12) 28 Operating Humidity - 29 Storage Temperature - 30 Storage Humidity - 31 Cooling - 2.0-3.63 32 Withstand Voltage o o 3.79 - 4.95 o -30 - +85oC 10 - 95%RH (No Dewdrop) Convection Cooling Input - FG : 2kVAC(20mA), Input - Output : 3kVAC (20mA) Output - FG : 500VAC(100mA), for 1min. 33 Isolation Resistance - 34 Vibration - More than 100MW at 25oC and 70%RH Output - FG : 500VDC At no operating, 10-55Hz (Sweep for 1min) 19.6 m/s2 Constant, X, Y, Z 1h each. 35 Shock (In package) - 36 Safety (*13) 2 - Less than 196.1 m/s Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1 - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11 Designed to meet DENAN 37 EMI 38 Immunity (*15) 39 Weight (Typ) 40 Size (W x H x D) - 800g mm 97.5 x 44.5 x 225 (Refer to Outline Drawing) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. For V2, V3,V4 stability, require minimum output current of V1. o *2. At 100/200VAC, Ta=25 C and total allowable output power. *3. For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 240VAC(50/60Hz). *4. Not applicable for the inrush current to Noise Filter for less than 0.2ms. *5. Refer to output measuring (A190-01-05/A-_) for line & load regulation and ripple voltage. *6. 85 - 265VAC , constant load. *7. Minimum load - Full load, constant input voltage. *8. Constant current limit with automatic recovery. Refer to test data (A190-53-01_). Not operate at over load or dead short condition for more than 30 seconds. *9. OVP circuit will shut down all outputs, manual reset (Line recycle). *10. At 100/200VAC, nominal output voltage and total allowable output power. *11. Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25oC. *12. At standard mounting. - Load (%) is percent of total allowable output power or each maximum output current, whichever is greater. For other mountings, refer to derating curve (A190-01-03/A-_). *13. As for DENAN, designed to meet at 100VAC. *14. Refer to test data (A190-58-01_). *15. Allowable output power is changed according to V4 voltage, refer to derating table (A190-01-03/A-_). *16. Operating period at peak current is less than 10sec.. (Duty<0.35) DENSEI-LAMBDA ZWQ80/A SPECIFICATIONS (FORCED AIR COOLING) A190-01-07/A-A MODEL ZWQ80-5223/A ITEMS V V1 V2 V3 V4 +5 +12 -12 +3.3 1 Nominal Output Voltage 2 Minimum Output Current (*1) A 1.4 0 0 0 3 Maximum Output Current A 10.0 2.5 2.5 9.0 4 Total Allowable Output Power (*2) W 5 Input Current (100/200VAC) (Typ (*3) A 1.6 / 0.8 6 Operating Temperature (*4) - -10 ~ +60oC (-10 ~+40oC : 100%, +60oC : 50%) 7 Cooling (*5) - Forced Air Cooling 88.7 *Read instruction manual carefully, before using the power supply unit. =NOTES= *For other items, refer to convection cooling specifications (A190-01-01/A-_). *1. For V2, V3,V4 stability, require minimum output current of V1. When it is using under condition of forced air cooling, V1 minimum output current is same as convection cooling. *2. Allowable output power is changed according to V4 voltage, refer to derating table (A190-01-04/A-_). *3. At 100/200VAC, Ta=25oC total allowable output power. *4. At standard mounting. - Load (%) is percent of total allowable output power or each maximum output current, whichever is greater. For other mountings, refer to derating curve (A190-01-04/A-_). *5. Air flow > 0.85m3/min(30cfm) Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: ZWQ805224/A