A190-01-01/A-D
SPECIFICATIONS (CONVECTION COOLING)
MODEL ZWQ80-5225/A ZWQ80-5222/A ZWQ80-5224/A
ITEMS V1 V2 V3 V4 V1 V2 V3 V4 V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +5 +5 +12 -12 +12 +5 +12 -12 +24
2 Minimum Output Current (Convection) (*1) A 0.9 0 0 0 0.9 0 0 0 0.9 0 0 0
3
Minimum Output Current (Peak Application) (*1)
A 1.4 0 0 0 1.4 0 0 0 1.4 0 0 0
4 Maximum Output Current A 8.0 2.0 2.0 7.0 8.0 2.0 2.0 3.0 8.0 2.0 2.0 1.5
5 Total Allowable Output Power (*15) W 80 80 80
6 Maximum Peak Output Current (*16) A 10.0 2.5 2.5 9.0 10.0 2.5 2.5 4.0 10.0 2.5 2.5 2.0
7 Total Allowable Peak Output Power (*15) W 104 104 104
8 Efficiency (Typ) (*2) % 72
9 Input Voltage Range (*3) - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
10 Input Current (100/200VAC) (Typ) (*2) A 1.2 / 0.6
11 Inrush Current (Typ) (*4) - 14A at 100VAC, 28A at 200VAC, Ta=25oC, Cold Start
12 PFHC - Designed to meet IEC61000-3-2
13 Power Factor (100/200VAC) (Typ) (*2) - 0.99 / 0.93
14 Output Voltage Range V 5.0-5.25 +12/+15 -12/-15 2.0-5.25 5.0-5.25 +12/+15 -12/-15 11.4-12.6 5.0-5.25 +12/+15 -12/-15 22.8-25.2
15 Output Voltage Accuracy - - +5% +5% - - +5% +5% - - +5% +5% -
16 Maximum Ripple & Noise mV 120 150 150 120 120 150 150 150 120 150 150 200
(*5) mV 160 180 180 160 160 180 180 180 160 180 180 200
17 Maximum Line Regulation (*5,6) mV 20 48 48 20 20 48 48 48 20 48 48 96
18 Maximum Load Regulation (*5,7) mV 100 300 300 100 100 300 300 300 100 300 300 400
19 Temperature Coefficient - Less than 0.02% /oC
20 Over Current Protection (*8) - More than 109.2W of Total Output Power
21 Over Voltage Protection (*9) V 5.7 - 7.0 16.5-22.5 16.5-22.5 5.7 - 7.0 5.7 - 7.0 16.5-22.5 16.5-22.5 13.8-16.2 5.7 - 7.0 16.5-22.5 16.5-22.5 27.6-32.4
22 Hold-Up Time (Typ) (*10) - 20 ms
23 Leakage Current (*11) - 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
24 Remote ON/OFF Control
25 Parallel Operation - -
26 Series Operation - -
27 Operating Temperature (*12) - -10 - +50oC (-10 - +30oC : 100%, +50oC : 50%)
28 Operating Humidity - 30 - 90%RH (No Dewdrop)
29 Storage Temperature - -30 - +85oC
30 Storage Humidity - 10 - 95%RH (No Dewdrop)
31 Cooling - Convection Cooling
32 Withstand Voltage Input - FG : 2kVAC(20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC(100mA), for 1min.
33 Isolation Resistance - More than 100MW at 25oC and 70%RH Output - FG : 500VDC
34 Vibration - At no operating, 10-55Hz (Sweep for 1min)
19.6 m/s2 Constant, X, Y, Z 1h each.
35 Shock (In package) - Less than 196.1 m/s2
36 Safety (*13) - Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Designed to meet DENAN
37 EMI - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B
38 Immunity (*14) - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11
39 Weight (Typ) - 800g
40 Size (W x H x D) mm 97.5 x 44.5 x 225 (Refer to Outline Drawing)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. For V2, V3,V4 stability, require minimum output current of V1. *11. Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25oC.
*2. At 100/200VAC, Ta=25oC and total allowable output power. *12. At standard mounting.
*3. For cases where conformance to various safety specs (UL, CSA, EN) are required, - Load (%) is percent of total allowable output power or
to be described as 100 - 240VAC(50/60Hz). each maximum output current, whichever is greater.
*4. Not applicable for the inrush current to Noise Filter for less than 0.2ms. For other mountings, refer to derating curve (A190-01-03/A-_).
*5. Refer to output measuring (A190-01-05/A-_) for line & load regulation *13. As for DENAN, designed to meet at 100VAC.
and ripple voltage. *14. Refer to test data (A190-58-01_).
*6. 85 - 265VAC , constant load. *15. Allowable output power is changed according to V4 voltage(Only ZWQ-5225/A),
*7. Minimum load - Full load, constant input voltage. refer to derating table(A190-01-03/A-_).
*8. Constant current limit with automatic recovery. Refer to test data (A190-53-01_). *16. Operating period at peak current is less than 10sec.. (Duty<0.35)
Not operate at over load or dead short condition for more than 30 seconds.
*9. OVP circuit will shut down all outputs, manual reset (Line recycle).
*10. At 100/200VAC, nominal output voltage and total allowable output power.
-
0 < Ta < +50oC
-10 < Ta < 0oC