TDK-Lambda
ZWQ80/A
A190-01-01/A-D
SPECIFICATIONS (CONVECTION COOLING)
MODEL ZWQ80-5225/A ZWQ80-5222/A ZWQ80-5224/A
ITEMS V1 V2 V3 V4 V1 V2 V3 V4 V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +5 +5 +12 -12 +12 +5 +12 -12 +24
2 Minimum Output Current (Convection) (*1) A 0.9 0 0 0 0.9 0 0 0 0.9 0 0 0
3
Minimum Output Current (Peak Application) (*1)
A 1.4 0 0 0 1.4 0 0 0 1.4 0 0 0
4 Maximum Output Current A 8.0 2.0 2.0 7.0 8.0 2.0 2.0 3.0 8.0 2.0 2.0 1.5
5 Total Allowable Output Power (*15) W 80 80 80
6 Maximum Peak Output Current (*16) A 10.0 2.5 2.5 9.0 10.0 2.5 2.5 4.0 10.0 2.5 2.5 2.0
7 Total Allowable Peak Output Power (*15) W 104 104 104
8 Efficiency (Typ) (*2) % 72
9 Input Voltage Range (*3) - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
10 Input Current (100/200VAC) (Typ) (*2) A 1.2 / 0.6
11 Inrush Current (Typ) (*4) - 14A at 100VAC, 28A at 200VAC, Ta=25oC, Cold Start
12 PFHC - Designed to meet IEC61000-3-2
13 Power Factor (100/200VAC) (Typ) (*2) - 0.99 / 0.93
14 Output Voltage Range V 5.0-5.25 +12/+15 -12/-15 2.0-5.25 5.0-5.25 +12/+15 -12/-15 11.4-12.6 5.0-5.25 +12/+15 -12/-15 22.8-25.2
15 Output Voltage Accuracy - - +5% +5% - - +5% +5% - - +5% +5% -
16 Maximum Ripple & Noise mV 120 150 150 120 120 150 150 150 120 150 150 200
(*5) mV 160 180 180 160 160 180 180 180 160 180 180 200
17 Maximum Line Regulation (*5,6) mV 20 48 48 20 20 48 48 48 20 48 48 96
18 Maximum Load Regulation (*5,7) mV 100 300 300 100 100 300 300 300 100 300 300 400
19 Temperature Coefficient - Less than 0.02% /oC
20 Over Current Protection (*8) - More than 109.2W of Total Output Power
21 Over Voltage Protection (*9) V 5.7 - 7.0 16.5-22.5 16.5-22.5 5.7 - 7.0 5.7 - 7.0 16.5-22.5 16.5-22.5 13.8-16.2 5.7 - 7.0 16.5-22.5 16.5-22.5 27.6-32.4
22 Hold-Up Time (Typ) (*10) - 20 ms
23 Leakage Current (*11) - 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
24 Remote ON/OFF Control
25 Parallel Operation - -
26 Series Operation - -
27 Operating Temperature (*12) - -10 - +50oC (-10 - +30oC : 100%, +50oC : 50%)
28 Operating Humidity - 30 - 90%RH (No Dewdrop)
29 Storage Temperature - -30 - +85oC
30 Storage Humidity - 10 - 95%RH (No Dewdrop)
31 Cooling - Convection Cooling
32 Withstand Voltage Input - FG : 2kVAC(20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC(100mA), for 1min.
33 Isolation Resistance - More than 100MW at 25oC and 70%RH Output - FG : 500VDC
34 Vibration - At no operating, 10-55Hz (Sweep for 1min)
19.6 m/s2 Constant, X, Y, Z 1h each.
35 Shock (In package) - Less than 196.1 m/s2
36 Safety (*13) - Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Designed to meet DENAN
37 EMI - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B
38 Immunity (*14) - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11
39 Weight (Typ) - 800g
40 Size (W x H x D) mm 97.5 x 44.5 x 225 (Refer to Outline Drawing)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. For V2, V3,V4 stability, require minimum output current of V1. *11. Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25oC.
*2. At 100/200VAC, Ta=25oC and total allowable output power. *12. At standard mounting.
*3. For cases where conformance to various safety specs (UL, CSA, EN) are required, - Load (%) is percent of total allowable output power or
to be described as 100 - 240VAC(50/60Hz). each maximum output current, whichever is greater.
*4. Not applicable for the inrush current to Noise Filter for less than 0.2ms. For other mountings, refer to derating curve (A190-01-03/A-_).
*5. Refer to output measuring (A190-01-05/A-_) for line & load regulation *13. As for DENAN, designed to meet at 100VAC.
and ripple voltage. *14. Refer to test data (A190-58-01_).
*6. 85 - 265VAC , constant load. *15. Allowable output power is changed according to V4 voltage(Only ZWQ-5225/A),
*7. Minimum load - Full load, constant input voltage. refer to derating table(A190-01-03/A-_).
*8. Constant current limit with automatic recovery. Refer to test data (A190-53-01_). *16. Operating period at peak current is less than 10sec.. (Duty<0.35)
Not operate at over load or dead short condition for more than 30 seconds.
*9. OVP circuit will shut down all outputs, manual reset (Line recycle).
*10. At 100/200VAC, nominal output voltage and total allowable output power.
-
0 < Ta < +50oC
-10 < Ta < 0oC
DENSEI-LAMBD
A
ZW
Q
80/A
A190-01-02/A-A SPECIFICATIONS
FORCED AIR COOLING
MODEL ZWQ80-5225/A ZWQ80-5222/A ZWQ80-5224/A
ITEMS V1 V2 V3 V4 V1 V2 V3 V4 V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +5 +5 +12 -12 +12 +5 +12 -12 +24
2 Minimum Output Current (*1) A 1.4 0 0 0 1.4 0 0 0 1.4 0 0 0
3 Maximum Output Current A 10.0 2.5 2.5 9.0 10.0 2.5 2.5 4.0 10.0 2.5 2.5 2.0
4 Total Allowable Output Power (*2) W 104 104 104
5 Input Current (100/200VAC) (Ty
p
(*3) A 1.6 / 0.8
6 Operating Temperature (*4) - -10 ~ +60oC (-10 ~+40oC : 100%, +60oC : 50%)
7 Cooling (*5) - Forced Air Cooling
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*For other items, refer to convection cooling specifications (A190-01-01/A-_).
*1. For V2, V3,V4 stability, require minimum output current of V1.
When it is using under condition of forced air cooling, V1 minimum output current is same as convection cooling.
*2. Allowable output power is changed according to V4 voltage(Only ZWQ-5225/A), refer to derating table (A190-01-04/A-_).
*3. At 100/200VAC, Ta=25
oC total allowable output power.
*4. At standard mounting.
- Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
For other mountings, refer to derating curve (A190-01-04/A-_).
*5. Air flow > 0.85m3/min(30cfm)
DENSEI-LAMBD
A
ZWQ80/A OUTPUT DERATING
(
CONVECTION COOLING
)
A190-01-03/A
Allowable output power
5225/A 5223/A
Ta
(
oC
)
ABC ABC
-10 ~+15 5V 104W 80W 3.3V 88.7W 80W
20 3V 86W 80W 3V 86W 80W
25 2V 77W 77W 2V 77W 77W
30
35 A : V4 setting voltage
40 B : Total Allowable Peak Output Power
45 C : Total Allowable Output Power
50 * The period of peak current at Convection Cooling
is limited less than 10sec.. (Duty < 0.35)
For peak current application, refer to note
(A190-01-05/A_).
* Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
MOUNT A MOUNT B,C,D MOUNT E
LOAD (%)
100 100 100
100 100 100
100 87 75
100 100 87
87 75 62
50
75 62 50
62 50
OUTPUT DERATING CURVE FOR CONVECTION COOLING
0
20
40
60
80
100
-100 10203040506070
Ta (゚C)
LOAD(%)
MOUNT A
MOUNT B,C,D
MOUNT E
MOUNTING
B
MOUNTING
C
MOUNTING
D
PROHIBI
T
MOUNTING
A
(STANDARD MOUNTING) ×
MOUNTING
E
Please refer to Instruction manual.
DENSEI-LAMBD
A
ZWQ80/A OUTPUT DERATING
(
FORCED AIR COOLING
)
A190-01-04/A
Allowable output power
5225/A 5223/A
Ta(℃)AA
-10 ~+30 100 5V 3.3V
35 100 3V 3V
40 100 2V 2V
45 87
50 75 A : V4 setting voltage
55 62 B : Total Allowable Output Power
60 50
* Air flow > 0.85m3/min
(
30cfm
)
Air must flow through component side.
* Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
77W
B
88.7W
86W
LOAD (%)
MOUNT A,B,C,D,E 104W
86W
77W
B
OUTPUT DERATING CURVE FOR CONVECTION COOLING
0
20
40
60
80
100
-100 1020304050607080
Ta (゚C)
LOAD(%)
MOUNT A,B,C,D,E
MOUNTING
B
MOUNTING
C
MOUNTING
D
PROHIBI
T
MOUNTING
A
(
STANDARD MOUNTING
)
×
MOUNTING
E
Please refer to Instraction manual.
DENSEI-LAMBD
A
ZW
Q
80/A NOTE
A190-01-05/A
Output Measuring
C1,C2,C3,C4 : Film Cap. 0.1
µ
F
C5 : Elec. Ca
p
.1000
µ
F
C6,C7,C8 : Elec. Ca
p
.100
µ
F
Peak Output Current (Convection Cooling)
Ip : Peak output current ( A )
Iav : Average output current ( A )
( Maximum output current (Convection) in Spec. )
Im : Average output current ( A )
Ï„ : Pulse width of peak output current ( sec )
( Operating time at peak output )
T : Period ( sec ) : more than 10ms
* The period of peak current at Convection Cooling
is limited less than 10sec.. (Duty < 0.35)
* Take V1 minmum output current more than 1.4A.
Capacitance
G3
V4
V3
G1
V1
Measure with EIAJ RC-9131 probe.
Bandwidth of scope : 100MHz
V2
G2
P.S 150mm
C5
C1 RL1
AWG18
C6 +
C2 RL2
C7 +
C3 RL3
C8 +
C4 RL4
T
Ip Im
Ï„
0A
T
Ip Im
Ï„
0A
aA
Iav Ip
≥=
×
Im
Ï„
Τ
(
)
a
aIp
Iav +
Τ
×
−
=≥
Ï„
Im
Measuring Point for Vo and Line/Load Regulation.
+
+
+
+
A
A
A
A
Measuring Point for Ripple & Noise.
TDK-Lambda
ZWQ80/A
A190-01-06/A-D
SPECIFICATIONS (CONVECTION COOLING)
MODEL ZWQ80-5223/A
ITEMS V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +3.3
2 Minimum Output Current (Convection) (*1) A 0.9 0 0 0
3
Minimum Output Current (Peak Application) (*1)
A 1.4 0 0 0
4 Maximum Output Current A 8.0 2.0 2.0 7.0
5 Total Allowable Output Power (*16) W 80
6 Maximum Peak Output Current (*17) A 10.0 2.5 2.5 9.0
7 Total Allowable Peak Output Power (*16) W 88.7
8 Efficiency (Typ) (*2) % 72
9 Input Voltage Range (*3) - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
10 Input Current (100/200VAC) (Typ) (*2) A 1.2 / 0.6
11 Inrush Current (Typ) (*4) - 14A at 100VAC, 28A at 200VAC, Ta=25oC, Cold Start
12 PFHC - Designed to meet IEC61000-3-2
13 Power Factor (100/200VAC) (Typ) (*2) - 0.99 / 0.93
14 Output Voltage Range V 5.0-5.25 +12/+15 -12/-15 2.0-3.63
15 Output Voltage Accuracy - - +5% +5% -
16 Maximum Ripple & Noise mV 120 150 150 120
(*5) mV 160 180 180 160
17 Maximum Line Regulation (*5,6) mV 20 48 48 20
18 Maximum Load Regulation (*5,7) mV 100 300 300 100
19 Temperature Coefficient - Less than 0.02% /oC
20 Over Current Protection (*8) - More than 93.1W of Total Output Power
21 Over Voltage Protection (*9) V 5.7 - 7.0 16.5-22.5 16.5-22.5 3.79 - 4.95
22 Hold-Up Time (Typ) (*10) - 20 ms
23 Leakage Current (*11) - 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
24 Remote ON/OFF Control (*14)
25 Parallel Operation - -
26 Series Operation - -
27 Operating Temperature (*12) - -10 - +50oC (-10 - +30oC : 100%, +50oC : 50%)
28 Operating Humidity - 30 - 90%RH (No Dewdrop)
29 Storage Temperature - -30 - +85oC
30 Storage Humidity - 10 - 95%RH (No Dewdrop)
31 Cooling - Convection Cooling
32 Withstand Voltage Input - FG : 2kVAC(20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC(100mA), for 1min.
33 Isolation Resistance - More than 100MW at 25oC and 70%RH Output - FG : 500VDC
34 Vibration - At no operating, 10-55Hz (Sweep for 1min)
19.6 m/s2 Constant, X, Y, Z 1h each.
35 Shock (In package) - Less than 196.1 m/s2
36 Safety (*13) - Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Designed to meet DENAN
37 EMI - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B
38 Immunity (*15) - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11
39 Weight (Typ) - 800g
40 Size (W x H x D) mm 97.5 x 44.5 x 225 (Refer to Outline Drawing)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. For V2, V3,V4 stability, require minimum output current of V1. *11. Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25oC.
*2. At 100/200VAC, Ta=25oC and total allowable output power. *12. At standard mounting.
*3. For cases where conformance to various safety specs (UL, CSA, EN) are required, - Load (%) is percent of total allowable output power or
to be described as 100 - 240VAC(50/60Hz). each maximum output current, whichever is greater.
*4. Not applicable for the inrush current to Noise Filter for less than 0.2ms. For other mountings, refer to derating curve (A190-01-03/A-_).
*5. Refer to output measuring (A190-01-05/A-_) for line & load regulation *13. As for DENAN, designed to meet at 100VAC.
and ripple voltage. *14. Refer to test data (A190-58-01_).
*6. 85 - 265VAC , constant load. *15. Allowable output power is changed according to V4 voltage, refer to derating table
*7. Minimum load - Full load, constant input voltage. (A190-01-03/A-_).
*8. Constant current limit with automatic recovery. Refer to test data (A190-53-01_). *16. Operating period at peak current is less than 10sec.. (Duty<0.35)
Not operate at over load or dead short condition for more than 30 seconds.
*9. OVP circuit will shut down all outputs, manual reset (Line recycle).
*10. At 100/200VAC, nominal output voltage and total allowable output power.
Possible
0 < Ta < +50oC
-10 < Ta < 0oC
DENSEI-LAMBD
A
ZW
Q
80/A
A190-01-07/A-A SPECIFICATIONS
FORCED AIR COOLING
MODEL ZWQ80-5223/A
ITEMS V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +3.3
2 Minimum Output Current (*1) A 1.4 0 0 0
3 Maximum Output Current A 10.0 2.5 2.5 9.0
4 Total Allowable Output Power (*2) W 88.7
5 Input Current (100/200VAC) (Ty
p
(*3) A 1.6 / 0.8
6 Operating Temperature (*4) - -10 ~ +60oC (-10 ~+40oC : 100%, +60oC : 50%)
7 Cooling (*5) - Forced Air Cooling
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*For other items, refer to convection cooling specifications (A190-01-01/A-_).
*1. For V2, V3,V4 stability, require minimum output current of V1.
When it is using under condition of forced air cooling, V1 minimum output current is same as convection cooling.
*2. Allowable output power is changed according to V4 voltage, refer to derating table (A190-01-04/A-_).
*3. At 100/200VAC, Ta=25
oC total allowable output power.
*4. At standard mounting.
- Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
For other mountings, refer to derating curve (A190-01-04/A-_).
*5. Air flow > 0.85m3/min(30cfm)