5© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard T2034_T140_AXIAL_T242 • 10/19/2018
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
5
Tantalum Through-Hole Capacitors – Hermetically Sealed
T140 Series Axial MIL–PRF–39003 Polar Type and T242 (CSR23 Style)
Rated
Voltage
Rated
Cap
Case
Size
Code
KEMET Part
Number
DC
Leakage
DF
% at
25°C
MIL–PRF–39003 (CSR23) Capacitors
Dash Number Reference
KEMET
Equivalent
Military
Failure Rate Level (%/1,000 Hours)
MIL–PRF–39003/3F MIL–PRF–39003/3F
Exponential Graded
(V) 85°C µF (See below for
part options) µA at 25°C
Max/5 Minutes 120 Hz
Maximum M
(1.0) P
(0.1) R
(0.01)
S
(0.001)
G
(1)
B
(0.1)
C
(0.01)
D
(0.001) Part Number
10 560.0 DT140D567K010A(3) 20.0 10 0131 0231 0331 0431 5031 2031 3031 4031 T242D567K010(2)S
10 560.0 DT140D567M010A(3) 20.0 10
15 3.9 AT140A395(1)015A(3) 1 4
15 4.7 AT140A475K015A(3) 1 4 0132 0232 0332 0432 5032 2032 3032 4032 T242A475K015(2)S
15 4.7 AT140A475M015A(3) 1 4 0133 0233 0333 0433 5033 2033 3033 4033 T242A475M015(2)S
15 5.6 AT140A565K015A(3) 1.3 40134 0234 0334 0434 5034 2034 3034 4034 T242A565K015(2)S
15 5.6 AT140A565M015A(3) 1.3 4
15 27.0 BT140B276(1)015A(3) 3 6
15 33.0 BT140B336K015A(3) 5 6 0135 0235 0335 0435 5035 2035 3035 4035 T242B336K015(2)S
15 33.0 BT140B336M015A(3) 5 6 0136 0236 0336 0436 5036 2036 3036 4036 T242B336M015(2)S
15 39.0 BT140B396K015A(3) 5.3 60137 0237 0337 0437 5037 2037 3037 4037 T242B396K015(2)S
15 39.0 BT140B396M015A(3) 5.3 6
15 82.0 CT140C826(1)015A(3) 8 6
15 100.0 CT140C107(1)015A(3) 10 6
15 120.0 CT140C127(1)015A(3) 10 6
15 150.0 CT140C157K015A(3) 15 80138 0238 0338 0438 5038 2038 3038 4038 T242C157K015(2)S
15 150.0 CT140C157M015A(3) 15 80139 0239 0339 0439 5039 2039 3039 4039 T242C157M015(2)S
15 180.0 CT140C187K015A(3) 15 80140 0240 0340 0440 5040 2040 3040 4040 T242C187K015(2)S
15 180.0 CT140C187M015A(3) 15 8
15 220.0 DT140D227K015A(3) 20 80141 0241 0341 0441 5041 2041 3041 4041 T242D227K015(2)S
15 220.0 DT140D227M015A(3) 20 80142 0242 0342 0442 5042 2042 3042 4042 T242D227M015(2)S
15 270.0 DT140D277K015A(3) 20 80143 0243 0343 0443 5043 2043 3043 4043 T242D277K015(2)S
15 270.0 DT140D277M015A(3) 20 8
15 330.0 DT140D337K015A(3) 20 80144 0244 0344 0444 5044 2044 3044 4044 T242D337K015(2)S
15 330.0 DT140D337M015A(3) 20 80145 0245 0345 0445 5045 2045 3045 4045 T242D337M015(2)S
20 2.7 AT140A275K020A(3) 0.8 40146 0246 0346 0446 5046 2046 3046 4046 T242A275K020(2)S
20 2.7 AT140A275M020A(3) 0.8 4
20 3.3 AT140A335K020A(3) 1.0 40147 0247 0347 0447 5047 2047 3047 4047 T242A335K020(2)S
20 3.3 AT140A335M020A(3) 1.0 40148 0248 0348 0448 5048 2048 3048 4048 T242A335M020(2)S
20 3.9 AT140A395K020A(3) 1.2 40149 0249 0349 0449 5049 2049 3049 4049 T242A395K020(2)S
20 3.9 AT140A395M020A(3) 1.2 4
20 18.0 BT140B186K020A(3) 3.0 60150 0250 0350 0450 5050 2050 3050 4050 T242B186K020(2)S
20 18.0 BT140B186M020A(3) 3.0 6
20 22.0 BT140B226K020A(3) 3.0 60151 0251 0351 0451 5051 2051 3051 4051 T242B226K020(2)S
20 22.0 BT140B226M020A(3) 3.0 60152 0252 0352 0452 5052 2052 3052 4052 T242B226M020(2)S
20 27.0 BT140B276K020A(3) 4.0 60153 0253 0353 0453 5053 2053 3053 4053 T242B276K020(2)S
20 27.0 BT140B276M020A(3) 4.0 6
20 56.0 CT140C566K020A(3) 7.0 60154 0254 0354 0454 5054 2054 3054 4054 T242C566K020(2)S
20 56.0 CT140C566M020A(3) 7.0 6
20 68.0 CT140C686K020A(3) 8.0 60155 0255 0355 0455 5055 2055 3055 4055 T242C686K020(2)S
20 68.0 CT140C686M020A(3) 8.0 60156 0256 0356 0456 5056 2056 3056 4056 T242C686M020(2)S
20 82.0 CT140C826K020A(3) 10.0 60157 0257 0357 0457 5057 2057 3057 4057 T242C826K020(2)S
20 82.0 CT140C826M020A(3) 10.0 6
20 100.0 CT140C107K020A(3) 12.0 60158 0258 0358 0458 5058 2058 3058 4058 T242C107K020(2)S
20 100.0 CT140C107M020A(3) 12.0 60159 0259 0359 0459 5059 2059 3059 4059 T242C107M020(2)S
20 120.0 CT140C127K020A(3) 12.0 60160 0260 0360 0460 5060 2060 3060 4060 T242C127K020(2)S
20 120.0 CT140C127M020A(3) 12.0 6
20 150.0 DT140D157K020A(3) 15.0 80161 0261 0361 0461 5061 2061 3061 4061 T242D157K020(2)S
20 150.0 DT140D157M020A(3) 15.0 80162 0262 0362 0462 5062 2062 3062 4062 T242D157M020(2)S
(V) 85°C µF Case Size
Code
(See below for
µA at 25°C
120 Hz
M
P
R
S
G
B
C
D
Part Number
Rated
Voltage Rated
Cap KEMET Part
Number
DC
Leakage DF % at
25°C MIL–PRF–39003 (CSR23) Capacitors
Table 1 – Ratings & Part Number Reference cont'd
(1) To complete KEMET part number, insert M for ±20% or K for ±10%. Designates capacitance tolerance.
(2) To complete KEMET part number (T242), insert failure rate code from Ordering Information table.
(3) To complete KEMET T140 Part Number, insert Lead Material designator: S – Standard or T – 100% Matte Tin. Designates termination nish.