W134M/W134S Direct RambusTM Clock Generator Features Description * Differential clock source for Direct RambusTM memory subsystem for up to 800-MHz data transfer rate * Provide synchronization flexibility: the Rambus(R) Channel can optionally be synchronous to an external system or processor clock The Cypress W134M/W134S provides the differential clock signals for a Direct Rambus memory subsystem. It includes signals to synchronize the Direct Rambus Channel clock to an external system clock but can also be used in systems that do not require synchronization of the Rambus clock. * Power-managed output allows Rambus Channel clock to be turned off to minimize power consumption for mobile applications * Works with Cypress CY2210, W133, W158, W159, W161, and W167 to support Intel(R) architecture platforms * Low-power CMOS design packaged in a 24-pin QSOP (150-mil SSOP) package Block Diagram REFCLK MULT0:1 PCLKM Pin Configuration PLL Phase Alignment CLK Output Logic 1 24 S0 2 23 S1 VDD 3 22 VDD GND 4 21 GND GND 5 20 CLK PCLKM 6 19 NC SYNCLKN 7 18 CLKB GND 8 17 GND CLKB SYNCLKN S0:1 VDDIR REFCLK VDD 9 16 VDD VDDIPD 10 15 MULT0 STOPB 11 14 MULT1 PWRDNB 12 13 GND Test Logic STOPB Cypress Semiconductor Corporation Document #: 38-07426 Rev. *C * 3901 North First Street * San Jose, CA 95134 * 408-943-2600 Revised June 1, 2005 W134M/W134S Pin Definitions Pin Name No. Type Description REFCLK 2 I Reference Clock Input. Reference clock input, normally supplied by a system frequency synthesizer (Cypress W133). PCLKM 6 I Phase Detector Input. The phase difference between this signal and SYNCLKN is used to synchronize the Rambus Channel Clock with the system clock. Both PCLKM and SYNCLKN are provided by the Gear Ratio Logic in the memory controller. If Gear Ratio Logic is not used, this pin would be connected to Ground. SYNCLKN 7 I Phase Detector Input. The phase difference between this signal and PCLKM is used to synchronize the Rambus Channel Clock with the system clock. Both PCLKM and SYNCLKN are provided by the Gear Ratio Logic in the memory controller. If Gear Ratio Logic is not used, this pin would be connected to Ground. STOPB 11 I Clock Output Enable. When this input is driven to active LOW, it disables the differential Rambus Channel clocks. PWRDNB 12 I Active LOW Power-down. When this input is driven to active LOW, it disables the differential Rambus Channel clocks and places the W134M/W134S in power-down mode. MULT 0:1 15, 14 I PLL Multiplier Select. These inputs select the PLL prescaler and feedback dividers to determine the multiply ratio for the PLL for the input REFCLK. MULT0 0 0 1 1 W134M PLL/REFCLK 4.5 6 8 5.333 MULT1 0 1 1 0 W134S PLL/REFCLK 4 6 8 5.333 CLK, CLKB 20, 18 O Complementary Output Clock. Differential Rambus Channel clock outputs. S0, S1 24, 23 I Mode Control Input. These inputs control the operating mode of the W134M/W134S. S0 0 0 1 1 NC 19 - S1 0 1 0 1 MODE Normal Output Enable Test Bypass Test No Connect VDDIR 1 RefV Reference for REFCLK. Voltage reference for input reference clock. VDDIPD 10 RefV Reference for Phase Detector. Voltage reference for phase detector inputs and StopB. VDD 3, 9, 16, 22 P Power Connection. Power supply for core logic and output buffers. Connected to 3.3V supply. GND 4, 5, 8, 13, 17, 21 G Ground Connection. Connect all ground pins to the common system ground plane. Phase Align PLL Busclk D RAC Synclk/N RMC W134M/W134S Refclk Pclk/M W133 W158 W159 W161 W167 CY2210 M N Pclk Gear 4 DLL Synclk Ratio Logic Figure 1. DDLL System Architecture Document #: 38-07426 Rev. *C Page 2 of 12 W134M/W134S Key Specifications (Rambus Channel). At the mid-point of the channel, the RAC senses Busclk using its own DLL for clock alignment, followed by a fixed divide-by-4 that generates Synclk. Supply Voltage: ...................................... VDD = 3.3V0.165V Pclk is the clock used in the memory controller (RMC) in the core logic, and Synclk is the clock used at the core logic interface of the RAC. The DDLL together with the Gear Ratio Logic enables users to exchange data directly from the Pclk domain to the Synclk domain without incurring additional latency for synchronization. In general, Pclk and Synclk can be of different frequencies, so the Gear Ratio Logic must select the appropriate M and N dividers such that the frequencies of Pclk/M and Synclk/N are equal. In one interesting example, Pclk = 133 MHz, Synclk = 100 MHz, and M = 4 while N = 3, giving Pclk/M = Synclk/N = 33 MHz. This example of the clock waveforms with the Gear Ratio Logic is shown in Figure 2. Operating Temperature: ................................... 0C to +70C Input Threshold: .................................................. 1.5V typical Maximum Input Voltage: ........................................ VDD+0.5V Maximum Input Frequency: .....................................100 MHz Output Duty Cycle:...................................40/60% worst case Output Type: ...........................Rambus signaling level (RSL) DDLL System Architecture and Gear Ratio Logic Figure 1 shows the Distributed Delay Lock Loop (DDLL) system architecture, including the main system clock source, the Direct Rambus clock generator (DRCG), and the core logic that contains the Rambus Access Cell (RAC), the Rambus Memory Controller (RMC), and the Gear Ratio Logic. (This diagram abstractly represents the differential clocks as a single Busclk wire.) The output clocks from the Gear Ratio Logic, Pclk/M, and Synclk/N, are output from the core logic and routed to the DRCG Phase Detector inputs. The routing of Pclk/M and Synclk/N must be matched in the core logic as well as on the board. After comparing the phase of Pclk/M vs. Synclk/N, the DRCG Phase Detector drives a phase aligner that adjusts the phase of the DRCG output clock, Busclk. Since everything else in the distributed loop is fixed delay, adjusting Busclk adjusts the phase of Synclk and thus the phase of Synclk/N. In this manner the distributed loop adjusts the phase of Synclk/N to match that of Pclk/M, nulling the phase error at the input of the DRCG Phase Detector. When the clocks are aligned, data can be exchanged directly from the Pclk domain to the Synclk domain. The purpose of the DDLL is to frequency-lock and phase-align the core logic and Rambus clocks (Pclk and Synclk) at the RMC/RAC boundary in order to allow data transfers without incurring additional latency. In the DDLL architecture, a PLL is used to generate the desired Busclk frequency, while a distributed loop forms a DLL to align the phase of Pclk and Synclk at the RMC/RAC boundary. The main clock source drives the system clock (Pclk) to the core logic, and also drives the reference clock (Refclk) to the DRCG. For typical Intel architecture platforms, Refclk will be half the CPU front side bus frequency. A PLL inside the DRCG multiplies Refclk to generate the desired frequency for Busclk, and Busclk is driven through a terminated transmission line Table 1 shows the combinations of Pclk and Busclk frequencies of greatest interest, organized by Gear Ratio. Table 1. Supported Pclk and Busclk Frequencies, by Gear Ratio Gear Ratio and Busclk Pclk 2.0 1.5 1.33 67 MHz 1.0 267 MHz 100 MHz 300 MHz 133 MHz 267 MHz 150 MHz 356 MHz 400 MHz 400 MHz 400 MHz 200 MHz 400 MHz Pclk Synclk Pclk/M = Synclk/N Figure 2. Gear Ratio Timing Diagram Document #: 38-07426 Rev. *C Page 3 of 12 W134M/W134S S0/S1 StopB W133 W158 W159 W161 W167 CY2210 Phase Align PLL Busclk D RAC Synclk/N Pclk/M RMC W134M/W134S Refclk M N Pclk Gear 4 DLL Synclk Ratio Logic Figure 3. DDLL Including Details of DRCG Figure 3 shows more details of the DDLL system architecture, including the DRCG output enable and bypass modes. Phase Detector Signals The DRCG Phase Detector receives two inputs from the core logic, PclkM (Pclk/M) and SynclkN (Synclk/N). The M and N dividers in the core logic are chosen so that the frequencies of PclkM and SynclkN are identical. The Phase Detector detects the phase difference between the two input clocks, and drives the DRCG Phase Aligner to null the input phase error through the distributed loop. When the loop is locked, the input phase error between PclkM and SynclkN is within the specification tERR,PD given in the Device Characteristics table after the lock time given in the State Transition Section. The Phase Detector aligns the rising edge of PclkM to the rising edge of SynclkN. The duty cycle of the phase detector input clocks will be within the specification DCIN,PD given in the Operating Conditions table. Because the duty cycles of the two phase detector input clocks will not necessarily be identical, the falling edges of PclkM and SynclkN may not be aligned when the rising edges are aligned. The voltage levels of the PclkM and SynclkN signals are determined by the controller. The pin VDDIPD is used as the voltage reference for the phase detector inputs and should be connected to the output voltage supply of the controller. In some applications, the DRCG PLL output clock will be used directly, by bypassing the Phase Aligner. If PclkM and SynclkN are not used, those inputs must be grounded. Selection Logic Table 2 shows the logic for selecting the PLL prescaler and feedback dividers to determine the multiply ratio for the PLL from the input Refclk. Divider A sets the feedback and divider B sets the prescaler, so the PLL output clock frequency is set by: PLLclk = Refclk*A/B. Document #: 38-07426 Rev. *C Table 2. PLL Divider Selection W134M W134S Mult0 Mult1 A B A B 0 0 9 2 4 1 0 1 6 1 6 1 1 1 8 1 8 1 1 0 16 3 16 3 Table 3 shows the logic for enabling the clock outputs, using the StopB input signal. When StopB is HIGH, the DRCG is in its normal mode, and Clk and ClkB are complementary outputs following the Phase Aligner output (PAclk). When StopB is LOW, the DRCG is in the Clk Stop mode, the output clock drivers are disabled (set to Hi-Z), and the Clk and ClkB settle to the DC voltage VX,STOP as given in the Device Characteristics table. The level of VX,STOP is set by an external resistor network. Table 3. Clock Stop Mode Selection Mode StopB Clk ClkB Normal 1 PAclk PAclkB Clk Stop 0 VX,STOP VX,STOP Table 4 shows the logic for selecting the Bypass and Test modes. The select bits, S0 and S1, control the selection of these modes. The Bypass mode brings out the full-speed PLL output clock, bypassing the Phase Aligner. The Test mode brings the Refclk input all the way to the output, bypassing both the PLL and the Phase Aligner. In the Output Test mode (OE), both the Clk and ClkB outputs are put into a high-impedance state (Hi-Z). This can be used for component testing and for board-level testing. Page 4 of 12 W134M/W134S Normal 0 0 Gnd PAclk PAclkB and S1 must be stable before power is applied to the device, and can only be changed in Power-down mode (PwrDnB = 0). The reference inputs, VDDR and VDDPD, may remain on or may be grounded during the Power-down mode. Table 6. Examples of Frequencies, Dividers, and Gear Ratios Output Test (OE) 0 1 - Hi-Z Hi-Z Bypass 1 0 PLLclk PLLclk PLLclkB Pclk Refclk Busclk Synclk A B M N Ratio F@PD Test 1 1 Refclk Refclk RefclkB Table 4. Bypass and Test Mode Selection Mode S0 S1 Bypclk (int.) Clk ClkB Table 5 shows the logic for selecting the Power-down mode, using the PwrDnB input signal. PwrDnB is active LOW (enabled when 0). When PwrDnB is disabled, the DRCG is in its normal mode. When PwrDnB is enabled, the DRCG is put into a powered-off state, and the Clk and ClkB outputs are three-stated. Table 5. Power-down Mode Selection Mode PwrDnB Clk ClkB Normal 1 PAclk PAclkB Power-down 0 GND GND 67 33 267 67 8 1 2 2 1.0 33 100 50 300 75 6 1 8 6 1.33 12.5 100 50 400 100 8 1 4 4 1.0 25 133 67 267 67 4 1 4 2 2.0 33 133 67 400 100 6 1 8 6 1.33 16.7 The control signals Mult0 and Mult1 can be used in two ways. If they are changed during Power-down mode, then the Power-down transition timings determine the settling time of the DRCG. However, the Mult0 and Mult1 control signals can also be changed during Normal mode. When the Mult control signals are "hot-swapped" in this manner, the Mult transition timings determine the settling time of the DRCG. In Normal mode, the clock source is on, and the output is enabled. Table of Frequencies and Gear Ratios Table 6 shows several supported Pclk and Busclk frequencies, the corresponding A and B dividers required in the DRCG PLL, and the corresponding M and N dividers in the gear ratio logic. The column Ratio gives the Gear Ratio as defined Pclk/Synclk (same as M and N). The column F@PD gives the divided down frequency (in MHz) at the Phase Detector, where F@PD = Pclk/M = Synclk/N. State Transitions The clock source has three fundamental operating states. Figure 4 shows the state diagram with each transition labelled A through H. Note that the clock source output may NOT be glitch-free during state transitions. Upon powering up the device, the device can enter any state, depending on the settings of the control signals, PwrDnB and StopB. In Power-down mode, the clock source is powered down with the control signal, PwrDnB, equal to 0. The control signals S0 VDD Turn-On M Table 7 lists the control signals for each state. Table 7. Control Signals for Clock Source States State Power-down Clock Stop Normal PwrDnB 0 1 1 StopB X 0 1 Clock Source OFF ON ON Output Buffer Ground Disabled Enabled Figure 5 shows the timing diagrams for the various transitions between states, and Table 8 specifies the latencies of each state transition. Note that these transition latencies assume the following. Refclk input has settled and meets specification shown in the Operating Conditions table. The Mult0, Mult1, S0 and S1 control signals are stable. VDD Turn-On J G L Test K VDD Turn-On N B Power-Down Normal F A E D VDD Turn-On Clk Stop C H Figure 4. Clock Source State Diagram Document #: 38-07426 Rev. *C Page 5 of 12 W134M/W134S Timing Diagrams Power-down Exit and Entry PwrDnB tPOWERDN tPOWERUP Clk/ClkB Output Enable Control tON StopB tSTOP tCLKON tCLKOFF tCLKSETL Clk/ClkB Output clock Clock enabled not specified and glitch-free glitches may occur Clock output settled within 50 ps of the phase before disabled Figure 5. State Transition Timing Diagrams Mult0 and/or Mult1 tMULT Clk/ClkB Figure 6. Multiply Transition Timing Table 8. State Transition Latency Specifications Transition Latency Transition From To Parameter Max. A Power-down Normal tPOWERUP 3 ms Time from PwrDnB to Clk/ClkB output settled (excluding tDISTLOCK). C Power-down Clk Stop tPOWERUP 3 ms Time from PwrDnB until the internal PLL and clock has turned ON and settled. K Power-down Test tPOWERUP 3 ms Time from PwrDnB to Clk/ClkB output settled (excluding tDISTLOCK). G VDD ON Normal tPOWERUP 3 ms Time from VDD is applied and settled until Clk/ClkB output settled (excluding tDISTLOCK). H VDD ON Clk Stop tPOWERUP 3 ms Time from VDD is applied and settled until internal PLL and clock has turned ON and settled. M VDD ON Test tPOWERUP 3 ms Time from VDD is applied and settled until internal PLL and clock has turned ON and settled. J Normal Normal tMULT 1 ms Time from when Mult0 or Mult1 changed until Clk/ClkB output resettled (excluding tDISTLOCK). Document #: 38-07426 Rev. *C Description Page 6 of 12 W134M/W134S Table 8. State Transition Latency Specifications (continued) Transition Latency Transition From To Parameter Max. E Clk Stop Normal tCLKON 10 ns E Clk Stop Normal tCLKSETL F Normal Clk Stop tCLKOFF 5 ns Time from StopB to Clk/ClkB output disabled. L Test Normal tCTL 3 ms Time from when S0 or S1 is changed until CLK/CLKB output has resettled (excluding tDISTLOCK). N Normal Test tCTL 3 ms Time from when S0 or S1 is changed until CLK/CLKB output has resettled (excluding tDISTLOCK). 1 ms Time from PwrDnB to the device in Power-down. B,D Description Time from StopB until Clk/ClkB provides glitch-free clock edges. 20 cycles Time from StopB to Clk/ClkB output settled to within 50 ps of the phase before CLK/CLKB was disabled. Normal or Clk Stop Power-down tPOWERDN Figure 5 shows that the Clk Stop to Normal transition goes through three phases. During tCLKON, the clock output is not specified and can have glitches. For tCLKON < t < tCLKSETL, the clock output is enabled and must be glitch-free. For t > tCLKSETL, the clock output phase must be settled to within 50 ps of the phase before the clock output was disabled. At this time, the clock output must also meet the voltage and timing specifications of the Device Characteristics table. The outputs are in a high-impedance state during the Clk Stop mode. Table 9. Distributed Loop Lock Time Specification Parameter Description tDISTLOCK Time from when Clk/ClkB output is settled to when the phase error between SynclkN and PclkM falls within the tERR,PD spec in Table . Min. Max. Unit 5 ms Min. Max. Unit Table 10.Supply and Reference Current Specification Parameter Description IPOWERDOWN "Supply" current in Power-down state (PwrDnB 1 = 0) - 250 A ICLKSTOP "Supply" current in Clk Stop state (StopB = 0) - 65 mA INORMAL "Supply" current in Normal state (StopB = 1, PwrDnB = 1) - 100 mA IREF,PWDN Current at VDDIR or VDDIPD reference pin in Power-down state (PwrDnB = 0) - 50 A IREF,NORM Current at VDDIR or VDDIPD reference pin in Normal or Clk Stop state (PwrDnB = 1) - 2 mA Document #: 38-07426 Rev. *C Page 7 of 12 W134M/W134S Absolute Maximum Conditions[1] Parameter Description Min. Max. Unit VDD, ABS Max. voltage on VDD with respect to ground -0.5 4.0 V VI, ABS Max. voltage on any pin with respect ground -0.5 VDD + 0.5 V External Component Values[2] Parameter Description Min. Max. Unit 39 5% RS Serial Resistor RP Parallel Resistor 51 5% CF Edge Rate Filter Capacitor 4-15[3] 10% pF CMID AC Ground Capacitor 470 pF 0.1 F 20% Operating Conditions[4] Parameter Description Min. Max. Unit 3.135 3.465 V Ambient Operating Temperature 0 70 C Refclk Input Cycle Time 10 40 ns VDD Supply Voltage TA tCYCLE,IN Jitter[5] tJ,IN Input Cycle-to-Cycle - 250 ps DCIN Input Duty Cycle over 10,000 Cycles 40 60 %tCYCLE FMIN Input Frequency of Modulation 30 33 kHz PMIN[6] Modulation Index for Triangular Modulation - 0.6 % % ns Modulation Index for Non-Triangular Modulation - 0.5[8] tCYCLE,PD Phase Detector Input Cycle Time at PclkM & SynclkN 30 100 tERR,INIT Initial Phase error at Phase Detector Inputs -0.5 0.5 tCYCLE,PD DCIN,PD Phase Detector Input Duty Cycle over 10,000 Cycles 25 75 tCYCLE,PD tI,SR Input Slew Rate (measured at 20%-80% of input voltage) for PclkM, SynclkN, and Refclk 1 4 V/ns CIN,PD Input Capacitance at PclkM, SynclkN, and Refclk[7] - 7 pF DCIN,PD Input Capacitance matching at PclkM and SynclkN[7] - 0.5 pF CIN,CMOS Input Capacitance at CMOS pins (excluding PclkM, SynclkN, and Refclk)[7] - 10 pF VIL Input (CMOS) Signal Low Voltage - 0.3 VDD VIH Input (CMOS) Signal High Voltage 0.7 - VDD VIL,R Refclk input Low Voltage - 0.3 VDDIR VIH,R Refclk input High Voltage 0.7 - VDDIR VIL,PD Input Signal Low Voltage for PD Inputs and StopB - 0.3 VDDIPD VIH,PD Input Signal High Voltage for PD Inputs and StopB 0.7 - VDDIPD VDDIR Input Supply Reference for Refclk 1.235 3.465 V VDDIPD Input Supply Reference for PD Inputs 1.235 2.625 V Notes: 1. Represents stress ratings only, and functional operation at the maximums is not guaranteed. 2. Gives the nominal values of the external components and their maximum acceptable tolerance, assuming ZCH = 28. 3. Do not populate CF. Leave pads for future use. 4. Multiple Supplies: The voltage on any input or I/O pin cannot exceed the power pin during power-up. Power supply sequencing is NOT required. 5. Refclk jitter measured at VDDIR (nom)/2. 6. If input modulation is used: input modulation is allowed but not required. 7. Capacitance measured at Freq=1 MHz, DC bias = 0.9V and VAC < 100 mV. 8. The amount of allowed spreading for any non-triangular modulation is determined by the induced downstream tracking skew, which cannot exceed the skew generated by the specified 0.6% triangular modulation. Typically, the amount of allowed non-triangular modulation is about 0.5%. Document #: 38-07426 Rev. *C Page 8 of 12 W134M/W134S Device Characteristics Parameter Description tCYCLE Clock Cycle Time tJ Cycle-to-Cycle Jitter at Clk/ClkB[9] Total Jitter over 2, 3, or 4 Clock Cycles[9] 266-MHz Cycle-to-Cycle Jitter[10] 266-MHz Total Jitter over 2, 3, or 4 Clock Cycles[10] Min. Max. Unit 2.5 3.75 ns - 60 ps - 100 ps - 100 ps - 160 ps 1 - ps tSTEP Phase Aligner Phase Step Size (at Clk/ClkB) tERR,PD Phase Detector Phase Error for Distributed Loop Measured at PclkM-SynclkN (rising edges) (does not include clock jitter) -100 100 ps tERR,SSC PLL Output Phase Error when Tracking SSC -100 100 ps VX,STOP Output Voltage during Clk Stop (StopB=0) 1.1 2.0 V VX Differential Output Crossing-Point Voltage 1.3 1.8 V VCOS Output Voltage Swing (p-p single-ended)[11] 0.4 0.6 V VOH Output High Voltage - 2.0 V VOL Output Low voltage 1.0 - V rOUT Output Dynamic Resistance (at pins)[12] 12 50 IOZ Output Current during Hi-Z (S0 = 0, S1 = 1) - 50 A IOZ,STOP Output Current during Clk Stop (StopB = 0) - 500 A DC Output Duty Cycle over 10,000 Cycles 40 60 %tCYCLE tDC,ERR Output Cycle-to-Cycle Duty Cycle Error - 50 ps tR,tF Output Rise and Fall Times (measured at 20%-80% of output voltage) 250 500 ps tCR,CF Difference between Output Rise and Fall Times on the Same Pin of a Single Device (20%-80%) - 100 ps Notes: 9. Output Jitter spec measured at tCYCLE = 2.5 ns. 10. Output Jitter Spec measured at tCYCLE = 3.75 ns. 11. VCOS = VOH-VOL. 12. rOUT = DVO/ D IO. This is defined at the output pins. Document #: 38-07426 Rev. *C Page 9 of 12 W134M/W134S Layout Example +3.3V Supply FB C4 0.005 F G 10 F C3 G VDDIR G G G G G G G VDDIPD 1 2 3 4G 5G 6 7 8G 9 10 11 12 24 23 22 G21 20 19 18 G17 46 15 14 G13 G G G G G Internal Power Supply Plane FB = Dale ILB1206 - 300 (300 @ 100 MHz) G = VIA to GND plane layer All Bypass cap = 0.1 Ceramic XR7 Ordering Information Ordering Code Package Type W134MH 24-pin QSOP (150 mils, SSOP) W134MHT 24-pin QSOP (150 mils, SSOP) - Tape and Reel W134SH 24-pin QSOP (150 mils, SSOP) W134SHT 24-pin QSOP (150 mils, SSOP) - Tape and Reel Lead-free CYW134MOXC 24-pin QSOP (150 mils, SSOP) CYW134MOXCT 24-pin QSOP (150 mils, SSOP), Tape and Reel CYW134SOXC 24-pin QSOP (150 mils, SSOP) CYW134SOXCT 24-pin QSOP (150 mils, SSOP), Tape and Reel Document #: 38-07426 Rev. *C Page 10 of 12 W134M/W134S Package Diagram 24-Lead Quarter Size Outline Q13 51-85055-*B Direct Rambus is a trademark and Rambus is a registered trademark of Rambus Inc. Intel is a registered trademark of Intel Corporation. All product and company names mentioned in this document may be the trademarks of their respective holders. Document #: 38-07426 Rev. *C Page 11 of 12 (c) Cypress Semiconductor Corporation, 2005. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use of any circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any license under patent or other rights. Cypress products are not warranted nor intended to be used for medical, life support, life saving, critical control or safety applications, unless pursuant to an express written agreement with Cypress. Furthermore, Cypress does not authorize its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges. W134M/W134S Document History Page Document Title: W134M/W134S Direct RambusTM Clock Generator Document Number: 38-07426 REV. ECN NO. Issue Date Orig. of Change Description of Change ** 115531 05/10/02 DSG Change from Spec number: 38-00822 to 38-07246 *A 122927 12/14/02 RBI Add power-up requirements to operating information *B 131671 12/15/03 RGL Added Lead-free to the W134M device in the ordering information table *C 375120 See ECN RGL Corrected the lead-free coding Document #: 38-07426 Rev. *C Page 12 of 12