For more Information
please call
1-800-Belden1
General Description:
Series 59, 20 AWG solid .032" bare copper-covered steel conductor, gas-injected foam polyethylene
insulation, Duofoil® or Duobond® + aluminum braid shield (40% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
120 Solid BCCS - Bare Copper Covered Steel 0.8128
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
Gas-injected FPE - Foam Polyethylene 3.6576
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid AL - Aluminum 40
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 6.020 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
UL Temperature Rating: 75°C
Bulk Cable Weight: 32.740 Kg/Km
Max. Recommended Pulling Tension: 355.856 N
Min. Bend Radius/Minor Axis: 63.500 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CATV, CM
CEC/C(UL) Specification: CM
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9275 Coax - 75 Ohm Coax
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Series Type: Series 59
Flame Test
UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75.000
Nom. Inductance:
Inductance (µH/m)
0.318257
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
53.1522
Nominal Velocity of Propagation:
VP (%)
83
Nominal Delay:
Delay (ns/m)
3.9372
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
146.005
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
55.777
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
52.46075
55 6.03704
211 11.0242
270 12.435
300 13.0912
350 14.2067
400 15.2895
450 16.2738
550 17.9799
750 21.3593
870 22.967
1000 25.1981
Max. Operating Voltage - UL:
Voltage
300 V RMS
Typical Structural Return Loss:
Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Typical SRL (dB)
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9275 Coax - 75 Ohm Coax
5550 18
Notes (Overall)
Notes: Sweep tested 5 MHz to 550 MHz.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
9275 009U1000 305 MT 10.433 KG WHITE #20 LDPE/GIFHDLDPE SH FRPVC
9275 010U1000 305 MT 10.433 KG BLACK #20 LDPE/GIFHDLDPE SH FRPVC
9275 010U500 152 MT 5.443 KG BLACK #20 LDPE/GIFHDLDPE SH FRPVC
9275 0101000 305 MT 10.886 KG BLACK #20 LDPE/GIFHDLDPE SH FRPVC
Revision Number: 2 Revision Date: 03-22-2013
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9275 Coax - 75 Ohm Coax