48 x 48 Digital LCD Timer 815E Part number 88857311
Relay output digital timers
LCD or LED (815E)
Multi
-range
Multi
-voltage
1 or 2 relay outputs
Reset function on panel (Timers 815, 815E)
Data saved in the event of a break in supply (Timer 815, 815E)
Access to programming lockable (Timer 814, 815 and 815E)
Up or down timing mode
Internal power supply by battery (10 years / 20 °C) (Not 815E)
Part numbers
Specifications
A1, A1C, A2, A2C, AM, AMT, B, BM, C, CM, D, Di, DiM, Dpause, H, HM, T,TM, W,
WM
2 double timed
changeover
12-24VAC/DC100→240V
AC
TIMER 812
- 814 -
815 : 8 mm
TIMER 815E : 7mm
99,99 s
999,9 s
9999 s
99 min 59 s
99,99 min
999,9 min
9999 min
99 h 59 min
99,99 h
999,9 h
9999 h ( ? 815E)
Repetition accuracy (with constant parameters)
TIMER 812
- 814 - 815 :
±
0,03 %
±
20 ms
TIMER 815E :
±
0,01 %
TIMER 812
- 814 - 815 :
±
0,03 %
±
20 ms
TIMER 815E :
±
0,01 %
Maximum reset time by de
-
energisation during timed delay
Maximum reset time by de
-
energisation after timing
TIMER 814
- 815 : 8 A AC 8 A DC
TIMER 812 : 5 A AC 5 A DC
TIMER 815E : 5 A
- 250 V AC
TIMER 812
- 814 - 815 : 250 V AC 30 V DC
TIMER 815E : 250 V AC 20 V DC
Maximum power rating (resistive)
TIMER 814
- 815 : 2000 VA -
190 W
TIMER 812 : 1250 VA
-
120 W
TIMER 815E : 1500 VA
-
100 W
Maximum admissible current
TIMER 812
- 814 -
815 : 250 V AC 30 V DC 100 mA
TIMER 815E : 500 mW (10 V / 5 mA)
Electrical life at I max., 250 V AC resistive (cycles)
Max. permitted number of operations at 1 max 250 V AC
resistive per hour
Mechanical life (operations)
TIMER 812
- 814 - 815 : 5 x 106
TIMER 815E : 20 x 10
6
TIMER 814 : + 10 %
- 15 %
TIMER 815E : + 10 %
- 10 %
Immunity from micro power cuts
0.5 W / 12 V 1 VA / 24 V
0.5 W / 24 V 3.5 VA / 110 V
1 W / 48 V 11 VA / 220 V
TIMER 815E : Max. 3 W
Temperature limits use (°C)
TIMER 812
- 814 - 815 : -
10°C→+60°C
TIMER815E:0°C→+60°C
Temperature limits stored (°C)
TIMER 812
- 814 - 815 : -
30°C→+70°C
TIMER 815E :
-
30°C→+80°C
Degree of protection front face
TIMER 812
- 814 -
815 : IP65
TIMER 815E : IP30
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected