ITEM
NUMBER TE PART
NUMBER DESCRIPTION QTY PER KIT
1 1055439-1 Cable Fixture Sub-Assembly 1
2 1055441-1 Clamp Insert for 2.16 [.085] Cable 1 Set
3 1055540-1 Clamp Insert for 3.58 [.141] Cable 1 Set
4 91362-1 0.38 [.015] Thick Solder Gage 1
5 1055470-1 Locator Tool 1
6 1055471-1 Locator Tool 1
7 1055472-1 Center Contact Holder 1
8 1055473-1 Dielectric Insert Tool 1
© 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
1 of 3
Instruction Sheet
TOOLING ASSISTANCE CENTER
1-800-722-1111
PRODUCT INFORMATION
1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com LOC B
408-8781
Solder Assembly Kit 1055468-1 11 AUG 11 Rev A
Figure 1
1. INTRODUCTION
Solder Assembly Kit 105546 8-1, shown in Figure 1, for
Type N Connectors contains everything necessary to
solder Type N solder-style connectors to 2.16 [.085]
and 3.58 [.141] diameter semi-rigid cable.
CAUTION
!
Tool directions in this document are for reference
only. Refer to the appropriate connector assembly
instructions to insure proper assembly. Refer to
Figure 2 for connector assemblies and their
associated instruction sheets.
NOTE
i
Dimensions are in metric units [with U.S. customary
units in brackets], unless otherwise indicated.
Contact custome r service or refer to Ca talog 1307191
for additional information.
2. DESCRIPTION
Solder Assembly Kit 1055468-1 contains the tooling
required to properl y solder Type N connectors to semi-
rigid coax cable. The kit contains a cable fixture sub-
assembly, two sets of clamp inse rts for 2.1 6 [.085] and
3.58 [.141] cable, and two types of locators that are
used to proper ly align the connector and cable. The kit
also contains a solder gage for proper spacing of the
center contact, a center contact holder , and a dielectric
insertion tool.
SEMI-RIGID CABLE APPLICATIONS
Connector Part Number Instruction Sheet
1057165-1 408-4744
1057176-1 408-4884
1057154-1 408-4903
1093513-1 408-4905
1057174-1 408-4908
1057175-1 408-4909
1057085-1
1057087-1 408-4910
1057160-1 408-4911
1057119-1
1057178-1 408-4912
1057116-1 408-4913
1057094-1 408-4914
1057088-1 408-4915
1058628-1 408-8243
1058627-1 408-8245
408-8781
2 of 3
Rev A
Figure 2
The cable fixture sub a sse m bly co ns ists of a fixture
frame, thumbscrew, positioning tool and spring. See
Figure 3. When used with the proper clamp insert s the
assembly holds and locates coaxial cable for
soldering.
3. IINSTALLING/REPLACING THE CLAMP INSERT
NOTE
i
Clamp inserts come in sets of two. Upper and lower
inserts are interchangeable.
1. Select the appropriate clamp inserts. Refer to
Figure 1 for the appropriate clamp inserts.
2. Remove the cable fixture thu mbscrew by rot ating
it in a counterclockwise direction.
3. Remove the positioning tool by rotating it in a
counterclockwise direction.
4. Remove the clamp inserts from the frame after
the positioning tool is removed.
5. Sandwich the spring in the pockets on the
replacement clamp inserts.
6. Place clamp inserts in the fixture frame and
reinstall the positioning tool.
7. Retighten positioning tool.
8. Reinstall the thumbscrew.
4. TRIMMING CABLE WITH FIXTURE FRAME
The fixture frame is equipped with six trimming holes
designed to remove the outer jacket and cable
dielectric. The side marked with the number 2 is for
trimming 1.78 [ .07 0 ], 2. 16 [.08 5 ], an d 3. 58 [. 14 1]
cable. See Figures 3 and 4. When cable is fully
bottomed during trimming, a strip length of 2.79 [.110]
will result. If different strip lengths are required the
center conductor must be trimmed separately.
The side marked with a number the number "1" is for
trimming cable already mounted in a connector
housing. See the connector specific instruction sheet
for more informa tio n.
NOTE
i
Trim blades are NOT included with the kit. Use a
razor blade with 0.38 [.015] maximum thickness.
5. USING SOLDER GAGE AND CENTER CONTACT
HOLDER
The center contact holder is designed to hold both
male and female center contact s for the Type N
connectors.
The solder gage is used to properly space the Type N
center contact away from the cable dielectric. Refer to
the connector specific instruction sheet for the
appropriate solder gage to be used during the
assembly procedure.
CAUTION
!
Center contact holders contains small amounts of
lead. The lead is used for assembly.
NOTE
i
Maximum operating temperature for the center
contact holder is 300°C [572°F]
DANGER
STOP
To avoid personal injury, be sure to observe all local
safety practices (including the use of gloves). The
solder gage, center contact holder, and the contact
may be hot after soldering.
6. USING LOCATING TOOLS
Solder Assembly Kit 1055468-1 contains two locating
tools. Refer to the connector specific instruction sheet
for selection of proper locator tool and assembly
instructions.
These tools are designed to be used with the fixture
subassembly. To insure proper connector assembly,
follow the instructions listed below.
1. Place connector housing on end of cable sub-
assembly. The subassembly refers to cabl e with
center contact.
Fixture Frame Thumb Screw Positioning
Tool
Spring
Trimming
Holes
Cable
Clamp
Inserts
408-8781
3 of 3
Rev A
Figure 3
2. Place loose connector assembly in fixture base.
3. Nest the center contact in locator tool.
4. Tighten the thumbscrew to secure the cable.
5. Tighten the locato r tool to seat the cable firmly.
6. Slide connector housing over locator tool.
7. Maintain position of housing fir mly against locator
tool.
DANGER
STOP
To avoid personal injury, be sure to follow all local
safety practices when using solder and solder
equipment.
For 1.78
[.070] Cable
For 2.16
[.085] Cable
For 3.58
[.141] Cable
Figure 4
8. Solder according to the connector specific
instructions.
NOTE
i
Fixture should be clamped vertically in vise to keep
housing seated against locator tool.
7. USING DIELECTRIC TOOLS
Solder Assembly Kit 10554668-1 contains one
dielectric tool. The dielectric (insertion) tool is used to
insert the dielectric bushing into the connector
housing.
Use the following instruction to press the dielectric
bushing into the connector subassembly.
1. Thread the insertion tool into connector
subassembly.
2. Insert the dielectric into insertion tool housing.
3. Place insertion tool plunger into position.
4. Press the plunger until the flange bottoms on the
tool housing.
8. REVISION SUMMARY
Since the previous release of this instruction sheet,
the new company logo was applied.