https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page1/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Base element for type 1/2 arresters from the VALVETRAB MS T1/T2 product range, with remote indication
contact. Version: 1-channel
Why buy this product
Plug-in direction parallel to the conductor axis
Versions with and without floating remote indication contact
Rack-mount 2U panel applications
Accepts Type 1 and Type 2 VAL-MS plugs.
Coding when protective plug is inserted for the first time
DIN rail mounting
Key Commercial Data
Packing unit 1 STK
GTIN
GTIN 4046356983372
Weight per Piece (excluding packing) 1.000 g
Custom tariff number 85363030
Country of origin United States
Technical data
Dimensions
Height 77.1 mm
Width 17.6 mm
Depth 89.2 mm
Ambient conditions
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page2/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Technical data
Ambient conditions
Degree of protection IP20
IP20
Ambient temperature (operation) -40 °C ... 80 °C
Altitude max. 2000 m
Permissible humidity (operation) 5 % ... 95 %
Shock (operation) 25g
Vibration (operation) 5g
General
IEC test classification I / II
T1 / T2
EN type T1 / T2
Mounting type DIN rail: 35 mm
Color black
Housing material PBT
Degree of pollution 2
Flammability rating according to UL 94 V0
Design DIN rail module, two-section, divisible
Number of positions 1
Surge protection fault message Remote indication contact
Remote indication contact
Additional descriptions
Note
For installation into a touch protected cabinet. For applications with UC >
500 V distances at the side and distances at the connection area must be
minimum of 5 mm between different active parts including earthed parts.
Protective circuit
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC600 V AC
Rated load current IL80 A (with serial 16mm² through wiring)
80 A (with serial 16mm² through wiring)
Short-circuit current rating ISCCR 25 kA
Max. backup fuse with branch wiring 160 A (gL/gG)
Max. backup fuse with V-type through wiring 80 A AC (gL/gG)
Indicator/remote signaling
Switching function PDT contact
Operating voltage 5 V AC ... 250 V AC
125 V AC (UL)
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page3/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Technical data
Indicator/remote signaling
30 V DC
Operating current 5 mA AC ... 1 A
1 A (UL)
1 A
Connection method Screw connection
Screw thread M2
Tightening torque 0.25 Nm
0.25 Nm
4 lbf-in. (UL)
Stripping length 7 mm
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section AWG 28 ... 16 (IEC)
30 ... 14 (UL)
Connection data
Connection method Biconnect terminal blocks
Screw thread M5
Tightening torque 3 Nm ... 4.5 Nm (UL)
27 lbf-in. ... 40 lbf-in. (UL)
Stripping length 16 mm
Conductor cross section flexible min. 1.5 mm²
Conductor cross section flexible max. 25 mm²
Conductor cross section solid min. 1.5 mm²
Conductor cross section solid max. 35 mm²
Conductor cross section AWG 15 ... 2 (IEC)
10 ... 2 (UL)
UL specifications
SPD Type 4 (for Type 2 applications)
Standards and Regulations
Standards/regulations IEC 61643-1 2005
EN 61643-11/A11 2007
Drawings
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page4/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Dimensional drawing
21,22
5,02
54,02
40,9345,6
77,06
76
29,79
17,6
Circuit diagram
12 14
11
FM
L
N / PEN
Classifications
eCl@ss
eCl@ss 5.1 27130801
eCl@ss 6.0 27130802
eCl@ss 8.0 27130803
eCl@ss 9.0 27130803
ETIM
ETIM 5.0 EC000472
ETIM 6.0 EC000472
UNSPSC
UNSPSC 13.2 39121620
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / cULus Recognized
Ex Approvals
Approval details
UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page5/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Approvals
cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181
cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Accessories
Accessories
Bridge
Wiring bridge-MPB 18/1- 2-2809209
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos.
Wiring bridge-MPB 18/1- 3-2809212
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos.
Wiring bridge-MPB 18/1- 4-2809225
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos.
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page6/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Wiring bridge-MPB 18/1- 6-2748564
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos.
Wiring bridge-MPB 18/1- 7 BU-2856278
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 7-pos., color: Blue
Wiring bridge-MPB 18/1- 8 BU-2858470
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos., color: Blue
Wiring bridge-MPB 18/1- 8-2748577
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos.
Wiring bridge-MPB 18/1- 9-2748580
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos.
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page7/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Wiring bridge-MPB 18/1-12-2748593
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos.
Wiring bridge-MPB 18/1-57-2809238
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos.
Wiring bridge-MPB 18/3- 6-2809241
Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos.
Wiring bridge-MPB 18/3- 9-2809254
Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 9-pos.
Wiring bridge-MPB 18/4- 8-2809283
Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos.
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page8/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Wiring bridge-MPB 18/4-12-2809296
Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos.
Wiring bridge-MPB F200X16/ 1GS-2818339
Wiring bridge flexible, diameter 16 mm², with a fork-type cable lug on one side, length: 200 mm
Wiring bridge-MPB F400X16/ 1GS-2818342
Wiring bridge flexible, diameter 16 mm², with a fork-type cable lug on one side, length: 400 mm
Wiring bridge-MPB F600X16/ 1GS-2818355
Wiring bridge flexible, diameter: 16 mm², with a fork-type cable lug on one side, length: 600 mm
Wiring bridge-MPB F600X16/ 1GS-2818355
Wiring bridge flexible, diameter: 16 mm², with a fork-type cable lug on one side, length: 600 mm
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page9/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Wiring bridge-MPB F400X16/ 1GS-2818342
Wiring bridge flexible, diameter 16 mm², with a fork-type cable lug on one side, length: 400 mm
Wiring bridge-MPB F200X16/ 1GS-2818339
Wiring bridge flexible, diameter 16 mm², with a fork-type cable lug on one side, length: 200 mm
Wiring bridge-MPB 18/1-10/1.0.0-2830443
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 10 pitches with contact sequence 1-0-0
Wiring bridge-MPB 18/1-20/1.2.5-2830168
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 20 pitches with contact sequence 1-2-0-0-5
Wiring bridge-MPB 18/4-12-2809296
Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos.
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page10/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Wiring bridge-MPB 18/4- 8-2809283
Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos.
Wiring bridge-MPB 18/3- 6-2809241
Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos.
Wiring bridge-MPB 18/1-57-2809238
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos.
Wiring bridge-MPB 18/1-12-2748593
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos.
Wiring bridge-MPB 18/1- 9-2748580
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos.
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page11/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Wiring bridge-MPB 18/1- 8-2748577
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos.
Wiring bridge-MPB 18/1- 6-2748564
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos.
Wiring bridge-MPB 18/1- 4-2809225
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos.
Wiring bridge-MPB 18/1- 3-2809212
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos.
Wiring bridge-MPB 18/1- 2-2809209
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos.
Device marking
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page12/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Zack marker strip-ZBN 18:UNBEDRUCKT-2809128
Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, Mounting type: Snap
into tall marker groove, for terminal block width: 18 mm, Lettering field: 18 x 5 mm
Feed-through terminal block
Feed-through terminal block-DK-BIC-35-2749880
Feed-through terminal block for VAL and FLT applications
Labeled device marker
Marker for terminal blocks-ZBN 18,LGS:ERDE-2749589
Marker for terminal blocks, Strip, white, labeled, Horizontal:Grounding symbol, Mounting type: Snap into tall marker
groove, for terminal block width: 18 mm, Lettering field: 18 x 5 mm
Marker for terminal blocks-ZBN 18,LGS:L1-N,ERDE-2749576
Marker for terminal blocks, Strip, white, labeled, Horizontal:L1, L2, L3, N, GND, Mounting type: Snap into tall marker
groove, for terminal block width: 18 mm, Lettering field: 18 x 5 mm
Marker pen
https://www.phoenixcontact.com/us/products/2905652
04/13/2017Page13/13
Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652
Accessories
Marker pen-B-STIFT-1051993
Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm
Phoenix Contact 2017 © - all rights reserved
http://www.phoenixcontact.com