Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors 1.1 Industrial Circuit Breakers QUICKLAG(R). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW . . . . . . . . . . . QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP . . . . . . . . . . . . . . . . . . . . Bolt-On Types BAB, QBHW, HBAX, HBAW. . . . . . . . . . . . . . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP . . . . . . . . . . . . . . . . . . . . Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . . . . . . . . . . . . . Solenoid Operator--Remote-Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers . . . . . . . . . . . . . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC. . . . . . . . . . . Special Application Breakers, Types HQP, BA, QC . . . . . . . . . . . . . . . 1.2 1 V4-T1-8 1 V4-T1-11 V4-T1-14 1 V4-T1-17 1 V4-T1-20 1 V4-T1-24 1 V4-T1-28 1 V4-T1-31 1 V4-T1-34 1 V4-T1-37 V4-T1-40 V4-T1-49 V4-T1-67 1 1 1 1 UL 1077 DIN Rail Supplementary Protectors FAZ Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WMZS Circuit Breaker. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 V4-T1-5 UL 489 DIN Rail Miniature Circuit Breakers FAZ-NA Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WMZ Circuit Breaker. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 V4-T1-2 V4-T1-82 V4-T1-103 1 1 1 Learn Online 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-1 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Contents Miniature Circuit Breakers and Supplementary Protectors Description 1 Quick Reference 1 1 1 1 1 1 1 1 1 1 1 1 QUICKLAG 1 Quick Reference 1 Eaton's QUICKLAG Industrial Circuit Breakers 1 Plug-In, Bolt-On, Cable-In/Cable-Out 1 Circuit Breaker Type 1 1 Circuit Breaker Type Code Continuous Ampere Rating at 40C Number of Poles Vac Vdc Interrupting Ratings rms Symmetrical Amperes Federal Spec. W-C-375b Vac Ratings 120 120/240 240 24-48 62.5 80 Vdc Ratings 2 Page Number HQP P 10-70 1 120/240 24, 48, 62.5 10a, 11a, 12a -- 10,000 -- 5000 3 -- V4-T1-6 HQP P 10-125 2 120/240 24, 48, 80 10a, 12a -- 10,000 -- 5000 5000 5000 V4-T1-6 HQP P 10-100 2, 3 240 -- 10b, 11b, 12b -- -- 10,000 -- -- -- V4-T1-6 -- V4-T1-6 1 QPHW P 15-70 1 120/240 24, 48, 62.5 14a -- 22,000 -- 5000 3 1 QPHW P 15-125 2 120/240 24, 48, 80 14a -- 22,000 -- 5000 5000 5000 V4-T1-6 QPHW P 15-100 2, 3 240 -- 14b -- -- 22,000 -- -- -- V4-T1-6 1 QHPX P 15-70 1 120/240 24, 48, 62.5 -- -- 42,000 -- 5000 3 -- V4-T1-7 QHPX P 15-100 2 120/240 24, 48, 80 -- -- 42,000 -- 5000 5000 5000 V4-T1-7 1 QHPX P 15-100 3 240 -- -- -- -- 42,000 -- -- -- V4-T1-7 QHPW P 15-30 1 120/240 24, 48, 62.5 15a -- 65,000 -- 5000 3 -- V4-T1-7 QHPW P 15-30 2 120/240 24, 48, 80 15a -- 65,000 -- 5000 5000 5000 V4-T1-7 V4-T1-7 1 1 1 1 1 1 1 QHPW P 15-20 3 240 -- 15b -- -- 65,000 -- -- -- QPGF P, GF 15-40 1 120 -- 10a, 11a, 12a 10,000 -- -- -- -- -- V4-T1-9 QPGF P, GF 15-50 2 120/240 -- 10a, 11a, 12a -- 10,000 -- -- -- -- V4-T1-9 Notes 1 QUICKLAG circuit breakers are suitable for application in relative humidity 0-95% noncondensing. 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL(R) listed. 3 62.5 Vac interrupting rating is 3800 AIC 10-50A and 2500 AIC 55-100A continuous. Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA. For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T1-31 to V4-T1-36. For Type WMZ circuit breakers, see Pages V4-T1-67 to V4-T1-81. For Types WMZS and SPHM supplementary protectors, see Pages V4-T1-103 to V4-T1-118. V4-T1-2 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Eaton's QUICKLAG Industrial Circuit Breakers 1 Plug-In, Bolt-On, Cable-In/Cable-Out, continued Circuit Breaker Type Circuit Breaker Type Code Continuous Ampere Rating at 40C 1 Interrupting Ratings rms Symmetrical Amperes Number of Poles Vac Vdc Federal Spec. W-C-375b Vac Ratings 120 120/240 Vdc Ratings 240 24-48 2 62.5 80 Page Number QPHGF P, GF 15-30 1 120 -- 10a, 11a, 12a 22,000 -- -- -- -- -- V4-T1-9 QPHGF P, GF 15-50 2 120/240 -- 10a, 11a, 12a -- 22,000 -- -- -- -- V4-T1-9 QPGFEP P, GFEP 15-40 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-9 QPGFEP P, GFEP 15-50 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-9 QPHGFEP P, GFEP 15-30 1 120 -- -- 22,000 -- -- -- -- -- V4-T1-9 BABRSP B 15-30 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-12 BABRSP B 15-30 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-12 BRRP P 15-30 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-32 BRRP P 15-30 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-32 CLRP P 15-30 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-32 CLRP P 15-30 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-32 BAB B 10-70 1 120/240 24, 48, 62.5 10a, 11a, 12a -- 10,000 -- 5000 3 -- V4-T1-12 BAB B 10-125 2 120/240 24, 48, 80 10a, 12a -- 10,000 -- 5000 5000 5000 V4-T1-12 BAB B 10-100 2, 3 240 -- 10b, 11b, 12b -- -- 10,000 -- -- -- V4-T1-12 BABRP B 15-30 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-32 BABRP B 15-30 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-32 QBAF B, AF 15-20 1, 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-15 QBCAF B, AF, GF 15-20 1, 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-15 QBHW B 15-70 1 120/240 24, 48, 62.5 14a -- 22,000 -- 5000 3 -- V4-T1-12 QBHW B 15-125 2 120/240 24, 48, 80 14a -- 22,000 -- 5000 5000 5000 V4-T1-12 QBHW B 15-100 2, 3 240 -- 14b -- -- 22,000 -- -- -- V4-T1-12 HBAX B 15-70 1 120/240 24, 48, 62.5 -- -- 42,000 -- 5000 3 -- V4-T1-13 HBAX B 15-100 2 120/240 24, 48, 80 -- -- 42,000 -- 5000 5000 5000 V4-T1-13 HBAX B 15-100 3 240 -- -- -- 42,000 -- -- -- V4-T1-13 HBAW B 15-30 1 120/240 24, 48, 62.5 15a -- 65,000 -- 5000 3 -- V4-T1-13 HBAW B 15-30 2 120/240 24, 48, 80 15a -- 65,000 -- 5000 5000 5000 V4-T1-13 HBAW B 15-20 3 240 -- 15b -- -- 65,000 -- -- -- V4-T1-13 QBGF B, GF 15-40 1 120 -- 10a, 11a, 12a 10,000 -- -- -- -- -- V4-T1-18 QBGF B, GF 15-50 2 120/240 -- 10a, 11a, 12a -- 10,000 -- -- -- -- V4-T1-18 QBHGF B, GF 15-30 1 120 -- 10a, 11a, 12a 22,000 -- -- -- -- -- V4-T1-18 QBHGF B, GF 15-30 1 120/240 -- 10a, 11a, 12a -- 22,000 -- -- -- -- V4-T1-18 QBGFEP B, GFEP 15-40 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-18 QBGFEP B, GFEP 15-50 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-18 QBHGFEP B, GFEP 15-30 1 120 -- -- 22,000 -- -- -- -- -- V4-T1-18 QBHGFEP B, GFEP 15-30 2 120/240 -- -- 22,000 22,000 -- -- -- -- V4-T1-18 QC C 10-70 1 120/240 24, 48, 62.5 10a, 11a, 12a -- 10,000 -- 5000 3 -- V4-T1-41 QC C 10-100 2 120/240 24, 48, 80 10a, 12a -- 10,000 -- 5000 5000 5000 V4-T1-41 QC C 10-100 2, 3, 4 240 -- 10b, 11b, 12b -- -- 10,000 -- -- -- V4-T1-41 QCD C 10-60 1, 2 120/240 24, 48, 62.5 -- 10,000 10,000 -- 3000 3000 -- V4-T1-23 QCD C 10-100 2, 3 240 24, 48, 62.5 -- -- 10,000 -- 3000 3000 -- V4-T1-23 QCF C 10-60 1, 2 120/240 24, 48, 62.5 -- 10,000 10,000 -- 3000 3000 -- V4-T1-42 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Notes 1 QUICKLAG circuit breakers are suitable for application in relative humidity 0-95% noncondensing. 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed. 3 62.5 Vac interrupting rating is 3800 AIC 10-50A and 2500 AIC 55-100A continuous. 1 Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA. For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T1-31 to V4-T1-36. For Type WMZ circuit breakers, see Pages V4-T1-67 to V4-T1-81. For Types WMZS and SPHM supplementary protectors, see Pages V4-T1-103 to V4-T1-118. 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1 1 V4-T1-3 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1 Eaton's QUICKLAG Industrial Circuit Breakers 1 Plug-In, Bolt-On, Cable-In/Cable-Out, continued 1 Circuit Breaker Type 1 QCF C 15-20 1, 2 1 QCF C 15-30 2, 3 QCR C 10-60 1, 2 1 QCR C 15-20 QCR C QCHW QCHW 1 1 Continuous Ampere Rating at 40C Interrupting Ratings rms Symmetrical Amperes Vac Ratings Vdc Federal Spec. W-C-375b 120 120/240 240 24-48 62.5 80 Page Number 120/240 24, 48, 62.5 -- 22,000 -- -- 3000 3000 -- V4-T1-27 240 24, 48, 62.5 -- -- 10,000 -- 3000 3000 -- V4-T1-27 120/240 24, 48, 62.5 -- 10,000 10,000 -- 3000 3000 -- V4-T1-27 1, 2 120/240 24, 48, 62.5 -- 22,000 -- -- 3000 3000 -- V4-T1-27 15-30 2, 3 240 24, 48, 62.5 -- -- 10,000 -- 3000 3000 -- V4-T1-27 C 15-70 1 120/240 24, 48, 62.5 14a -- 22,000 -- 5000 -- V4-T1-22 C 15-100 2 120/240 24, 48, 80 14a -- 22,000 -- 5000 5000 5000 V4-T1-22 -- -- V4-T1-22 3 -- V4-T1-22 Circuit Breaker Type Code Number of Poles Vac Vdc Ratings 2 3 QCHW C 15-100 2, 3 240 -- 14b -- -- 22,000 -- 1 QHCX C 15-70 1 120/240 24, 48, 62.5 -- -- 42,000 -- 5000 QHCX C 15-100 2 120/240 24, 48, 80 -- -- 42,000 -- 5000 5000 5000 V4-T1-22 1 QHCX C 15-100 3 240 -- -- -- -- 42,000 -- -- -- V4-T1-22 QHCW C 15-30 1 120/240 24, 48, 62.5 15a -- 65,000 -- 5000 3 -- V4-T1-22 QHCW C 15-30 2 120/240 24, 48, 80 15a -- 65,000 -- 5000 5000 5000 V4-T1-22 1 QHCW C 15-20 3 240 -- 15b -- -- 65,000 -- -- -- V4-T1-22 QCGF C, GF 15-40 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-29 1 QCGF C, GF 15-50 2 120/240 -- -- -- 10,000 -- -- -- -- V4-T1-29 QCHGF C, GF 15-30 1 120 -- -- 22,000 -- -- -- -- -- V4-T1-29 QCHGF C, GF 15-30 2 120/240 -- -- -- 22,000 -- -- -- -- V4-T1-29 QCGFEP C, GFEP 15-40 1 120 -- -- 10,000 -- -- -- -- -- V4-T1-29 V4-T1-29 1 1 1 1 1 1 1 1 1 QCGFEP C, GFEP 15-50 2 120/240 -- -- -- 10,000 -- -- -- -- QCHGFEP C, GFEP 15-30 1 120 -- -- 22,000 -- -- -- -- -- V4-T1-29 QCHGFEP C, GFEP 15-30 2 120/240 -- -- -- 22,000 -- -- -- -- V4-T1-29 Notes 1 QUICKLAG circuit breakers are suitable for application in relative humidity 0-95% noncondensing. 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed. 3 62.5 Vac interrupting rating is 3800 AIC 10-50A and 2500 AIC 55-100A continuous. Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA. For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T1-31 to V4-T1-36. For Type WMZ circuit breakers, see Pages V4-T1-67 to V4-T1-81. For Types WMZS and SPHM supplementary protectors, see Pages V4-T1-103 to V4-T1-118. . 1 1 1 1 1 1 1 1 1 1 V4-T1-4 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Contents QUICKLAG Type HQP Single-Pole Description Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers. . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . . Page 1 V4-T1-2 1 V4-T1-6 V4-T1-7 1 V4-T1-8 V4-T1-11 V4-T1-14 V4-T1-17 V4-T1-20 1 1 1 1 V4-T1-24 1 V4-T1-28 1 V4-T1-31 1 V4-T1-34 V4-T1-37 V4-T1-40 1 1 1 QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW 1 Product Description 1 All products 15-100A are HACR rated Switching duty rated for 120 Vac fluorescent light applications Standards and Certifications Built and listed to UL 489 All products UL and CSA(R) listed 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-5 1.1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Product Selection QUICKLAG Type HQP Single-Pole QUICKLAG Type: HQP 10,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40C 1 Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac Three-Pole 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 10 HQP1010 HQP2010 -- HQP3010H 3 1 15 HQP1015 12 HQP2015 HQP2015H HQP3015H 20 HQP1020 12 HQP2020 HQP2020H HQP3020H 1 25 HQP1025 HQP2025 HQP2025H HQP3025H 30 HQP1030 HQP2030 HQP2030H HQP3030H 1 35 HQP1035 HQP2035 HQP2035H HQP3035H 40 HQP1040 HQP2040 HQP2040H HQP3040H 1 45 HQP1045 HQP2045 HQP2045H HQP3045H 50 HQP1050 HQP2050 HQP2050H HQP3050H 1 55 HQP1055 HQP2055 HQP2055H HQP3055H 60 HQP1060 HQP2060 HQP2060H HQP3060H 1 70 HQP1070 HQP2070 HQP2070H HQP3070H 80 -- HQP2080 HQP2080H HQP3080H 1 90 -- HQP2090 HQP2090H HQP3090H 100 HQP1100 HQP2100 HQP2100H HQP3100H 1 110 -- HQP2110 -- -- 125 -- HQP2125 -- -- 1 150 -- HQP2150 -- -- Three-Pole 1 QUICKLAG Type: HQP Non-Automatic Switches 1 Continuous Ampere Rating at 40C 1 1 Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 50 HQP1050N -- HQP2050N HQP3050N 60 HQP1060N -- HQP2060N HQP3060N 100 HQP1100N -- HQP2100N HQP3100N 1 QUICKLAG Type: QPHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers 1 Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac Three-Pole 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number QPHW3015H 1 Continuous Ampere Rating at 40C 1 15 QPHW1015 1 QPHW2015 QPHW2015H 20 QPHW1020 1 QPHW2020 QPHW2020H QPHW3020H 25 QPHW1025 QPHW2025 QPHW2025H QPHW3025H 1 1 1 1 1 1 1 1 30 QPHW1030 QPHW2030 QPHW2030H QPHW3030H 35 QPHW1035 QPHW2035 QPHW2035H QPHW3035H 40 QPHW1040 QPHW2040 QPHW2040H QPHW3040H 45 QPHW1045 QPHW2045 QPHW2045H QPHW3045H 50 QPHW1050 QPHW2050 QPHW2050H QPHW3050H 55 QPHW1055 QPHW2055 QPHW2055H QPHW3055H 60 QPHW1060 QPHW2060 QPHW2060H QPHW3060H 70 QPHW1070 QPHW2070 QPHW2070H QPHW3070H 80 -- QPHW2080 QPHW2080H QPHW3080H 90 -- QPHW2090 QPHW2090H QPHW3090H 100 -- QPHW2100 QPHW2100H QPHW3100H 110 -- QPHW2110 -- -- 125 -- QPHW2125 -- -- Notes 1 Switching duty rated for 120 Vac fluorescent light applications. 2 For special low-magnetic breaker, order HQP1015L1 or HQP1020L1. 3 Not UL listed. 1 V4-T1-6 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 QUICKLAG Type: QHPX 42,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Continuous Ampere Rating at 40C Two-Pole Two-Pole 1 Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 15 QHPX1015 1 QHPX2015 -- QHPX3015H 20 QHPX1020 1 QHPX2020 -- QHPX3020H 25 QHPX1025 QHPX2025 -- QHPX3025H 30 QHPX1030 QHPX2030 -- QHPX3030H 35 QHPX1035 QHPX2035 -- QHPX3035H 40 QHPX1040 QHPX2040 -- QHPX3040H 45 QHPX1045 QHPX2045 -- QHPX3045H 50 QHPX1050 QHPX2050 -- QHPX3050H 55 QHPX1055 QHPX2055 -- QHPX3055H 60 QHPX1060 QHPX2060 -- QHPX3060H 70 QHPX1070 QHPX2070 -- QHPX3070H 80 -- QHPX2080 -- QHPX3080H 90 -- QHPX2090 -- QHPX3090H 100 -- QHPX2100 -- QHPX3100H 1 1 1 1 1 1 1 1 1 QUICKLAG Type: QHPW 65,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number QHPW2015 -- QHPW3015H -- QHPW3020H Continuous Ampere Rating at 40C Catalog Number 15 QHPW1015 1 20 QHPW1020 1 QHPW2020 25 QHPW1025 QHPW2025 -- -- 30 QHPW1030 QHPW2030 -- -- 1 1 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 Shipping Data Number of Poles Carton Quantity Approximate Weight Lbs (kg) Dimensions 1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 1 1 1 1 Note 1 Switching duty rated for 120 Vac fluorescent light applications. 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-7 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Contents QUICKLAG Type QPGF Single-Pole Ground Fault Circuit Breaker Description 1 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Product Description Standards and Certifications QUICKLAG Ground Fault Circuit Breakers, Class A GFCI 5 mA trip sensitivity QUICKLAG Ground Fault Equipment Protectors 30 mA trip sensitivity 1 Built and listed to UL 489 QUICKLAG Ground Fault Circuit Breakers, Class A GFCI Built and tested to UL 943 QUICKLAG Ground Fault Equipment Protectors Built and listed to UL 1053 1 1 1 1 1 1 1 1 1 1 V4-T1-8 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Page V4-T1-2 V4-T1-5 V4-T1-9 V4-T1-10 V4-T1-10 V4-T1-11 V4-T1-14 V4-T1-17 V4-T1-20 V4-T1-24 V4-T1-28 V4-T1-31 V4-T1-34 V4-T1-37 V4-T1-40 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Product Selection QUICKLAG Type QPGF Single-Pole 1 1 Ground Fault Circuit Breakers--5 mA Sensitivity QUICKLAG Type: QPGF 10,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QPGF1015 QPGF2015 20 QPGF1020 QPGF2020 25 QPGF1025 QPGF2025 30 QPGF1030 QPGF2030 40 QPGF1040 QPGF2040 50 -- QPGF2050 Continuous Ampere Rating at 40C 1 1 1 1 1 1 1 QUICKLAG Type: QPHGF 22,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QPHGF1015 QPHGF2015 20 QPHGF1020 QPHGF2020 25 QPHGF1025 QPHGF2025 30 QPHGF1030 QPHGF2030 Continuous Ampere Rating at 40C 1 1 1 1 1 1 Ground Fault Equipment Breakers--30 mA Sensitivity QUICKLAG Type: QPGFEP 10,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40C Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QPGFEP1015 QPGFEP2015 20 QPGFEP1020 QPGFEP2020 25 QPGFEP1025 QPGFEP2025 30 QPGFEP1030 QPGFEP2030 40 QPGFEP1040 QPGFEP2040 50 -- QPGFEP2050 1 1 1 1 1 1 1 QUICKLAG Type: QPHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40C Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QPHGFEP1015 QPHGFEP2015 20 QPHGFEP1020 QPHGFEP2020 25 QPHGFEP1025 QPHGFEP2025 30 QPHGFEP1030 QPHGFEP2030 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-9 1.1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Special Application Ground Fault Circuit Protectors--5 mA Sensitivity QUICKLAG Type: QPGF 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2) Continuous Ampere Rating at 40C Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 1 15 QPGF1015W1 QPGF2015W1 20 QPGF1020W1 QPGF2020W1 1 25 QPGF1025W1 QPGF2025W1 30 QPGF1030W1 QPGF2030W1 1 40 -- QPGF2040W1 50 -- QPGF2050W1 1 15 QPGF1015W2 -- 20 QPGF1020W2 -- 1 25 QPGF1025W2 -- 30 QPGF1030W2 -- 1 1 1 1 Special Application Ground Fault Circuit Protectors--30 mA Sensitivity QUICKLAG Type: QPGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2) Continuous Ampere Rating at 40C Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 1 15 QPGFEP1015W1 QPGFEP2015W1 20 QPGFEP1020W1 QPGFEP2020W1 1 25 QPGFEP1025W1 QPGFEP2025W1 30 QPGFEP1030W1 QPGFEP2030W1 1 40 -- QPGFEP2040W1 1 1 50 -- QPGFEP2050W1 15 QPGFEP1015W2 -- 20 QPGFEP1020W2 -- 25 QPGFEP1025W2 -- 30 QPGFEP1030W2 -- 1 1 Wiring Diagram 1 Bell Alarm and Auxiliary Contact Schematic Blue 1 Ground Fault Breaker 1 1 1 1 Blue Wire NC Red Dimensions Approximate Dimensions in Inches (mm) 1 Shipping Data 1 1 Red Wire Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W1)--contacts change state when breaker trips. Auxiliary Switch (W2)--contacts change state when breaker is opened (or tripped) or closed. 14-inch (355.6 mm) long 18 AWG pigtail wire leads provided. 1 1 Black Wire NO Number of Poles Carton Quantity Approximate Weight Lbs (kg) 1 24 11.00 (5.0) 12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0) 2 5 5.00 (2.3) 15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3) Dimensions Note Shipped individually or in carton quantities. V4-T1-10 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Contents QUICKLAG Type BAB Single-Pole Description Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers. . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . . Page V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-12 V4-T1-13 V4-T1-14 V4-T1-17 V4-T1-20 1 1 1 1 1 1 1 V4-T1-24 1 V4-T1-28 1 V4-T1-31 1 V4-T1-34 V4-T1-37 V4-T1-40 1 1 1 Bolt-On Types BAB, QBHW, HBAX, HBAW 1 Product Description 1 All products 15-100A are HACR rated Switching duty rated for 120 Vac fluorescent light applications Standards and Certifications Built and listed to UL 489 All products UL and CSA listed 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-11 1.1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Product Selection QUICKLAG Type BAB Single-Pole QUICKLAG Type: BA 10,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 10 BAB1010 BAB2010 BAB2010H 3 BAB3010H 3 15 BAB1015 12 BAB2015 BAB2015H BAB3015H 20 BAB1020 12 BAB2020 BAB2020H BAB3020H 1 25 BAB1025 BAB2025 BAB2025H BAB3025H 30 BAB1030 BAB2030 BAB2030H BAB3030H 1 35 BAB1035 BAB2035 BAB2035H BAB3035H 40 BAB1040 BAB2040 BAB2040H BAB3040H 45 BAB1045 BAB2045 BAB2045H BAB3045H Continuous Ampere Rating at 40C 1 1 1 1 1 1 1 1 Three-Pole 50 BAB1050 BAB2050 BAB2050H BAB3050H 55 BAB1055 BAB2055 BAB2055H BAB3055H 60 BAB1060 BAB2060 BAB2060H BAB3060H 70 BAB1070 BAB2070 BAB2070H BAB3070H 80 -- BAB2080 BAB2080H BAB3080H 90 -- BAB2090 BAB2090H BAB3090H 100 BAB1100 BAB2100 BAB2100H BAB3100H 110 -- BAB2110 -- -- 125 -- BAB2125 -- -- Three-Pole QUICKLAG Type: BA Non-Automatic Switches 1 Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number BAB3050N 1 Continuous Ampere Rating at 40C 1 50 BAB1050N -- BAB2050N 60 BAB1060N -- BAB2060N BAB3060N 100 BAB1100N -- BAB2100N BAB3100N 1 1 QUICKLAG Type: QBHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers 1 Continuous Ampere Rating at 40C 1 Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac Three-Pole 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 15 QBHW1015 1 QBHW2015 QBHW2015H QBHW3015H 1 20 QBHW1020 1 QBHW2020 QBHW2020H QBHW3020H 25 QBHW1025 QBHW2025 QBHW2025H QBHW3025H 1 30 QBHW1030 QBHW2030 QBHW2030H QBHW3030H 35 QBHW1035 QBHW2035 QBHW2035H QBHW3035H 1 40 QBHW1040 QBHW2040 QBHW2040H QBHW3040H 45 QBHW1045 QBHW2045 QBHW2045H QBHW3045H 1 50 QBHW1050 QBHW2050 QBHW2050H QBHW3050H 55 QBHW1055 QBHW2055 QBHW2055H QBHW3055H 1 60 QBHW1060 QBHW2060 QBHW2060H QBHW3060H 70 QBHW1070 QBHW2070 QBHW2070H QBHW3070H 80 -- QBHW2080 QBHW2080H QBHW3080H 1 1 1 90 -- QBHW2090 QBHW2090H QBHW3090H 100 -- QBHW2100 QBHW2100H QBHW3100H 110 -- QBHW2110 -- -- 125 -- QBHW2125 -- -- Notes 1 Switching duty rated for 120 Vac fluorescent light applications. 2 For special low-magnetic breaker, order BAB1015L1 or BAB1020L1. 3 Not UL listed. 1 1 V4-T1-12 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 QUICKLAG Type: HBAX 42,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 15 HBAX1015 1 HBAX2015 -- HBAX3015H 20 HBAX1020 1 HBAX2020 -- HBAX3020H 25 HBAX1025 HBAX2025 -- HBAX3025H 30 HBAX1030 HBAX2030 -- HBAX3030H 35 HBAX1035 HBAX2035 -- HBAX3035H 40 HBAX1040 HBAX2040 -- HBAX3040H 45 HBAX1045 HBAX2045 -- HBAX3045H 50 HBAX1050 HBAX2050 -- HBAX3050H 55 HBAX1055 HBAX2055 -- HBAX3055H 60 HBAX1060 HBAX2060 -- HBAX3060H 70 HBAX1070 HBAX2070 -- HBAX3070H 80 -- HBAX2080 -- HBAX3080H 80 -- HBAX2080 -- HBAX3080H 90 -- HBAX2090 -- HBAX3090H 100 -- HBAX2100 -- HBAX3100H Continuous Ampere Rating at 40C 1 Three-Pole 1 1 1 1 1 1 1 1 1 1 1 QUICKLAG Type: HBAW 65,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number HBAW1015 1 HBAW2015 -- HBAW3015H HBAW1020 1 HBAW2020 -- HBAW3020H 25 HBAW1025 HBAW2025 -- -- 30 HBAW1030 HBAW2030 -- -- Continuous Ampere Rating at 40C 15 20 1 1 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 Shipping Data Number of Poles Carton Quantity Approximate Weight Lbs (kg) Dimensions 1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 1 1 1 1 Note 1 Switching duty rated for 120 Vac fluorescent light applications. 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-13 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Bolt-On Arc Fault Circuit Interrupter QUICKLAG Types QBAF, QBCAF Contents Description 1 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . 1 1 1 1 1 1 1 1 1 1 1 1 Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF 1 Product Description All products HACR rated 1 Features, Benefits and Functions 1 1 10 and 22 kAIC rating at 120V and 120/240V Single-pole AFCI HID ratings for HID (High Intensity Discharge) lighting All models are HACR rated Standards and Certifications Built and listed to UL 489 UL File E7819 for QBAF 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-14 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Page V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-11 V4-T1-15 V4-T1-16 V4-T1-17 V4-T1-20 V4-T1-24 V4-T1-28 V4-T1-31 V4-T1-34 V4-T1-37 V4-T1-40 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Product Selection 1 QBCAF and QBAF Type AFCIs Effective immediately, Eaton AFCIs are available for use in Sumter panels with a 22 kAIC rating. This higher rated breaker will allow us to win jobs where AFCIs are specified at higher than 10 kAIC. This breaker provides standard thermal- QBHCAF magnetic protection of branch circuits. This product will have the same form, fit and function of the current bolt-on AFCI (QBCAF and QBAF Type). Product scope is below. These breakers are in Bid ManagerTM for Pow-RLine 1a, Pow-R-Line 1a-LX, 1 Pow-R-Line 3a and Pow-RLine 4a panelboards. For series rated combinations, continue to use the less expensive 10 kAIC QBCAF and QBAF offerings. 1 1 1 Breakers can also be ordered from Vista. 1 1 1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter Poles kAIC Rating Ampere Rating Configuration Catalog Number 15 Combination AFCI QBCAF1015 20 Combination AFCI QBCAF1020 15 Combination AFCI QBHCAF1015 20 Combination AFCI QBHCAF1020 15 Branch Feeder AFCI QBAF1015 20 Branch Feeder AFCI QBAF1020 15 Branch Feeder AFCI QBHAF1015 20 Branch Feeder AFCI QBHAF1020 1 1 Type QBCAF Combination AFCI Single-pole 10 kAIC 22 kAIC 1 1 1 Type QBAF Branch Feeder AFCI Single-pole 10 kAIC 22 kAIC 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-15 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1 Wiring Diagrams 1 Single-Pole 120V Load Application Sourced by 120/240 Vac 1 1 120/240 Vac Source N A B Line B 1 1 1 Single-Pole Neutral 120V Duplex Receptacle Neutral 1 Equipment Ground 1 1 1 1 Single-Pole Shared Neutral with Multi-Duplex Receptacle Application 120/240 Vac Source N A B 1 Line B 1 Two-Pole 1 1 Neutral Neutral 1 Two 120V Duplex Receptacles Line A 1 Equipment Ground 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-16 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Contents QUICKLAG Type QBGF Single-Pole Ground Fault Circuit Breaker Description QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers. . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . . Page 1 V4-T1-5 1 V4-T1-8 V4-T1-11 1 V4-T1-14 1 1 V4-T1-18 V4-T1-19 V4-T1-19 V4-T1-20 1 1 V4-T1-24 1 V4-T1-28 1 V4-T1-31 1 V4-T1-34 V4-T1-37 V4-T1-40 1 1 1 1 Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP Product Description Built and tested to UL 489 1 QUICKLAG Ground Fault Circuit Breakers, Class A GFCI Built and tested to UL 943 1 QUICKLAG Ground Fault Equipment Protectors Built and tested to UL 1053 1 QUICKLAG Ground Fault Circuit Breakers, Class A GFCI 5 mA trip sensitivity QUICKLAG Ground Fault Equipment Protectors 30 mA trip sensitivity 1 Standards and Certifications 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-17 1.1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Product Selection QUICKLAG Type QBGF Single-Pole Ground Fault Circuit Breakers--5 mA Sensitivity QUICKLAG Type: QBGF 10,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40C 1 1 Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QBGF1015 QBGF2015 20 QBGF1020 QBGF2020 25 QBGF1025 QBGF2025 1 30 QBGF1030 QBGF2030 40 QBGF1040 QBGF2040 1 50 -- QBGF2050 1 1 QUICKLAG Type: QBHGF 22,000A Interrupting Capacity Thermal-Magnetic Breakers 1 Continuous Ampere Rating at 40C 1 1 1 1 1 Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QBHGF1015 QBHGF2015 20 QBHGF1020 QBHGF2020 25 QBHGF1025 QBHGF2025 30 QBHGF1030 QBHGF2030 Ground Fault Equipment Breakers--30 mA Sensitivity QUICKLAG Type: QBGFEP 10,000A Interrupting Capacity Thermal-Magnetic Breakers 1 Continuous Ampere Rating at 40C 1 Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 1 15 QBGFEP1015 QBGFEP2015 20 QBGFEP1020 QBGFEP2020 1 25 QBGFEP1025 QBGFEP2025 30 QBGFEP1030 QBGFEP2030 40 QBGFEP1040 QBGFEP2040 50 -- QBGFEP2050 1 1 1 QUICKLAG Type: QBHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers 1 Continuous Ampere Rating at 40C 1 Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 1 15 QBHGFEP1015 QBHGFEP2015 20 QBHGFEP1020 QBHGFEP2020 1 25 QBHGFEP1025 QBHGFEP2025 30 QBHGFEP1030 QBHGFEP2030 1 1 1 1 V4-T1-18 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Special Application Ground Fault Circuit Protectors--5 mA Sensitivity QUICKLAG Type: QBGF 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2) Single-Pole Continuous Ampere Rating at 40C 1 Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QBGF1015W1 QBGF2015W1 20 QBGF1020W1 QBGF2020W1 25 QBGF1025W1 QBGF2025W1 30 QBGF1030W1 QBGF2030W1 40 -- QBGF2040W1 50 -- QBGF2050W1 15 QBGF1015W2 -- 20 QBGF1020W2 -- 25 QBGF1025W2 -- 30 QBGF1030W2 -- 1 1 1 1 1 1 1 1 Special Application Ground Fault Circuit Protectors--30 mA Sensitivity QUICKLAG Type: QBGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2) Single-Pole Continuous Ampere Rating at 40C 1 Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 15 QBGFEP1015W1 QBGFEP2015W1 20 QBGFEP1020W1 QBGFEP2020W1 25 QBGFEP1025W1 QBGFEP2025W1 30 QBGFEP1030W1 QBGFEP2030W1 40 -- QBGFEP2040W1 50 -- QBGFEP2050W1 15 QBGFEP1015W2 -- 20 QBGFEP1020W2 -- 25 QBGFEP1025W2 -- 30 QBGFEP1030W2 -- 1 1 1 1 1 1 1 Wiring Diagram 1 Bell Alarm and Auxiliary Contact Schematic 1 Blue Ground Fault Breaker Red 1 Blue Wire NC Black Wire 1 NO Red Wire 1 Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W1)--contacts change state when breaker trips. Auxiliary Switch (W2)--contacts change state when breaker is opened (or tripped) or closed. 14-inch (355.6 mm) long 18 AWG pigtail wire leads provided. 1 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 Shipping Data Number of Poles Approximate Weight Lbs (kg) Dimensions 1 11.00 (5.0) 12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0) 2 5.00 (2.3) 15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3) 1 1 Note Shipped individually or in carton quantities. 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-19 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Contents QUICKLAG Type QC Single-Pole Description 1 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . 1 1 1 1 1 1 1 1 1 1 1 1 Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW 1 Product Description 1 1 All products 10-100A are HACR rated Switching duty rated for 120 Vac fluorescent light applications only Standards and Certifications Built and listed to UL 489 All products UL and CSA listed 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-20 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Page V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-11 V4-T1-14 V4-T1-17 V4-T1-21 V4-T1-23 V4-T1-24 V4-T1-28 V4-T1-31 V4-T1-34 V4-T1-37 V4-T1-40 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Product Selection QUICKLAG Type QC Single-Pole 1 1 QUICKLAG Type: QC 10,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40C Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac 1 Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 5 QC1005 1 QC2005 1 -- -- -- 10 QC1010 QC2010 QC2010H 1 QC3010H 1 -- 15 QC1015 2 QC2015 QC2015H QC3015H QC4015H 20 QC1020 2 QC2020 QC2020H QC3020H QC4020H 25 QC1025 QC2025 QC2025H QC3025H QC4025H 30 QC1030 QC2030 QC2030H QC3030H QC4030H 35 QC1035 QC2035 QC2035H QC3035H QC4035H 40 QC1040 QC2040 QC2040H QC3040H QC4040H 45 QC1045 QC2045 QC2045H QC3045H QC4045H 50 QC1050 QC2050 QC2050H QC3050H QC4050H 55 QC1055 QC2055 QC2055H QC3055H QC4055H 60 QC1060 QC2060 QC2060H QC3060H QC4060H 70 QC1070 QC2070 QC2070H QC3070H QC4070H 70 -- QC2080 QC2080H QC3080H QC4080H 90 -- QC2090 QC2090H QC3090H QC4090H 100 QC1100 QC2100 QC2100H QC3100H QC4100H 1 1 1 1 1 1 1 1 1 1 1 QUICKLAG Type: QC Non-Automatic Switches 1 Continuous Ampere Rating at 40C Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 50 QC1050N -- QC2050N QC3050N -- 60 QC1060N -- QC2060N QC3060N -- 100 QC1100N -- QC2100N QC3100N -- 1 1 1 Notes 1 Not UL listed. 2 Switching duty rated for 120 Vac fluorescent light applications only. 1 1 For special low-magnetic breaker, order QC1015L1 or QC1020L1.Non-automatic switches, see Page V4-T1-42. 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-21 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers QUICKLAG Type: QCHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers 1 Single-Pole Two-Pole Two-Pole Three-Pole 1 Continuous Ampere Rating at 40C 120/240 Vac 120/240 Vac 240 Vac 240 Vac Four-Pole 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 1 15 QCHW1015 1 QCHW2015 QCHW2015H QCHW3015H QCHW4015H 1 20 QCHW1020 1 QCHW2020 QCHW2020H QCHW3020H QCHW4020H 25 QCHW1025 QCHW2025 QCHW2025H QCHW3025H QCHW4025H 1 30 QCHW1030 QCHW2030 QCHW2030H QCHW3030H QCHW4030H 35 QCHW1035 QCHW2035 QCHW2035H QCHW3035H QCHW4035H 1 40 QCHW1040 QCHW2040 QCHW2040H QCHW3040H QCHW4040H 45 QCHW1045 QCHW2045 QCHW2045H QCHW3045H QCHW4045H 1 1 1 1 1 50 QCHW1050 QCHW2050 QCHW2050H QCHW3050H QCHW4050H 55 QCHW1055 QCHW2055 QCHW2055H QCHW3055H QCHW4055H 60 QCHW1060 QCHW2060 QCHW2060H QCHW3060H QCHW4060H 70 QCHW1070 QCHW2070 QCHW2070H QCHW3070H QCHW4070H 70 -- QCHW2080 QCHW2080H QCHW3080H QCHW4080H 90 -- QCHW2090 QCHW2090H QCHW3090H QCHW4090H 100 -- QCHW2100 QCHW2100H QCHW3100H QCHW4100H 1 QUICKLAG Type: QHCX 42,000A Interrupting Capacity Thermal-Magnetic Breakers 1 Continuous Ampere Rating at 40C Single-Pole Two-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 15 QHCX1015 1 QHCX2015 -- QHCX3015H -- 1 20 QHCX1020 1 QHCX2020 -- QHCX3020H -- 25 QHCX1025 QHCX2025 -- QHCX3025H -- 1 30 QHCX1030 QHCX2030 -- QHCX3030H -- 1 35 QHCX1035 QHCX2035 -- QHCX3035H -- 40 QHCX1040 QHCX2040 -- QHCX3040H -- 1 45 QHCX1045 QHCX2045 -- QHCX3045H -- 50 QHCX1050 QHCX2050 -- QHCX3050H -- 1 55 QHCX1055 QHCX2055 -- QHCX3055H -- 60 QHCX1060 QHCX2060 -- QHCX3060H -- 1 70 QHCX1070 QHCX2070 -- QHCX3070H -- 1 70 -- QHCX2080 -- QHCX3080H -- 90 -- QHCX2090 -- QHCX3090H -- 100 -- QHCX2100 -- QHCX3100H -- 1 1 1 Four-Pole QUICKLAG Type: QHCW 65,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40C Single-Pole Two-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 15 QHCW1015 1 QHCW2015 -- QHCW3015H -- 1 20 QHCW1020 1 QHCW2020 -- QHCW3020H -- 1 25 QHCW1025 QHCW2025 -- -- -- 30 QHCW1030 QHCW2030 -- -- -- 1 1 1 Notes 1 Switching duty rated for 120 Vac fluorescent light applications only. 1 Non-automatic switches, see Page V4-T1-42. 1 V4-T1-22 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Four-Pole Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 QUICKLAG Type QCD Miniature Circuit Breakers Flexible power feed QCD breakers are used primarily in HVAC and connection: industrial applications. wire size, position Single-, two- and Same breaker size for three-pole options entire rating range Modular construction Field mountable accessories: DIN mounted finger shroud proof, quick (symmetrical rail 35 x connect terminals 7.5 DIN/EN 50 022) Other accessories: QCD same profile as jumper unit Type QCR QUICKLAG Type QCD Miniature Circuit Breaker 1 1 1 1 1 1 1 QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40C Single-Pole Two-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 10 QCD1010 QCD2010 -- -- 15 QCD1015 QCD2015 QCD2015H QCD3015H 20 QCD1020 QCD2020 QCD2020H QCD3020H 25 QCD1025 QCD2025 QCD2025H QCD3025H 30 QCD1030 QCD2030 QCD2030H QCD3030H 35 QCD1035 QCD2035 QCD2035H QCD3035H 40 QCD1040 QCD2040 QCD2040H QCD3040H 45 QCD1045 QCD2045 QCD2045H QCD3045H 50 QCD1050 QCD2050 QCD2050H QCD3050H 55 QCD1055 QCD2055 QCD2055H QCD3055H 60 QCD1060 QCD2060 QCD2060H QCD3060H 70 -- QCD2070 QCD2070H QCD3070H 80 -- QCD2080 QCD2080H QCD3080H 90 -- QCD2090 QCD2090H QCD3090H 100 -- QCD2090 QCD2090H QCD3100H -- QCD2100 QCD2100H -- 1 1 1 1 1 1 1 1 1 1 1 1 1 QUICKLAG Type QCD Non-Automatic Switches Continuous Ampere Rating at 40C Single-Pole Two-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 60 -- -- QCD2060NA -- 100 -- -- -- -- 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 Shipping Data Number of Poles Carton Quantity 1 Approximate Weight Lbs (kg) Dimensions 1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-23 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Contents Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH Description 1 1 1 1 1 Single-Pole Two-Pole QCR (Rear-Mounted Breakers) Single-Pole Two-Pole QCF (Front-Mounted Breakers) 1 1 1 1 1 1 Page Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH Product Selection . . . . . . . . . . . . . . . . . . . . . . . . QCR and QCF Options and Accessories . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-11 V4-T1-14 V4-T1-17 V4-T1-20 V4-T1-25 V4-T1-27 V4-T1-28 V4-T1-31 V4-T1-34 V4-T1-37 V4-T1-40 1 1 Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH 1 Product Description Application Description Eaton Type QCR circuit breakers have as a standard feature provisions for 35 mm DIN rail rear mounting with a spring-loaded release. Optional clips for individual mounting are available as a separate accessory. QCR and QCF circuit breakers are only 1/2-inch (12.7 mm) wide per pole and are excellent for general purpose industrial applications where space savings is required. 1 1 1 1 1 1 1 1 Type QCF have two threaded steel inserts to facilitate front mounting with #6-32 steel screws. The clamp type terminals are accessible from the rear of the breaker so that cables can be accessed without removal of the breaker from the front cover. Features, Benefits and Functions 1/2-inch (12.7 mm) wide per pole Cable-in/cable-out Black cases with black handles Three position handle: ON, Tripped (center), OFF Thermal-magnetic protection 1 1 1 1 1 1 1 V4-T1-24 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Standards and Certifications Built and listed to UL 489 UL File No. E7819 CSA File No. LR48907 Type QCR and QCF circuit breakers are UL listed circuit breakers that are suitable for use as branch circuit protectors All ratings 15-60A are HACR rated Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Product Selection Cable-In/Cable-Out, 1/2-Inch Wide 1 1 QCR Breaker Catalog Numbers 1234 Continuous Ampere Rating at 40C Three-Pole 1 Catalog Number Catalog Number 1 Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac 5 Catalog Number Catalog Number QCR Breaker 10 kAIC Interrupting Ratings 10 15 20 25 30 QCR1010 QCR2010 -- -- QCR1010T QCR2010T -- -- -- QCR2010P -- -- QCR1015 6 QCR2015 QCR2015H QCR3015H QCR1015T 6 QCR2015T QCR2015HT QCR3015HT -- QCR2015P -- -- QCR1020 6 QCR2020 QCR2020H QCR3020H QCR1020T 6 QCR2020T QCR2020HT QCR3020HT -- QCR2020P -- -- QCR1025 QCR2025 QCR2025H QCR3025H QCR1025T QCR2025T QCR2025HT QCR3025HT -- QCR2025P -- -- QCR1030 QCR2030 QCR2030H QCR3030H QCR1030T QCR2030T QCR2030HT QCR3030HT -- QCR2030P -- -- QCR1035 QCR2035 -- -- -- QCR2035P -- -- QCR1040 QCR2040 -- -- -- QCR2040P -- -- QCR1045 QCR2045 -- -- -- QCR2045P -- -- QCR1050 QCR2050 -- -- -- QCR2050P -- -- 55 QCR1055 QCR2055 -- -- -- QCR2055P -- -- 60 7 QCR1060 QCR2060 -- -- -- QCR2060P -- -- -- -- QCRH2015T -- -- QCRH2020 -- -- QCRH2020T -- -- 35 40 45 50 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 QCR Breaker 22 kAIC Interrupting Ratings 15 QCRH1015 6 QCRH1015T 20 6 QCRH1020 6 QCRH1020T 6 QCRH2015 1 1 1 Notes 1 Standard breaker terminals are box type lugs. 2 Breakers with T Catalog Number Suffix are suitable for line and load side ring terminal connection (#10-32 plus/minus terminal screw provided). 3 Breakers with P Catalog Number Suffix are suitable for terminating two 10 AWG Quick-Connect Type Terminals per phase on breaker load side. 4 Breakers with Shunt Trip (extra pole required on breaker right-hand side) are available on single-, two- and three-pole. Contact the Customer Support Center at 1-800-356-1243. 5 Breakers with H Catalog Suffix have 240 Vac construction. 6 All 15 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications. 7 60/75C Cu/Al wire on all ratings except 60A, which requires Cu only conductor. 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-25 1.1 1 Cable-In/Cable-Out, 1/2-Inch Wide Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers QCF Breaker Catalog Numbers 123 Single-Pole Two-Pole Two-Pole 120/240 Vac 120/240 Vac 240 Vac 4 Catalog Number Catalog Number Catalog Number Catalog Number 1 Continuous Ampere Rating at 40C 1 QCF Breaker 10 kAIC Interrupting Ratings 10 1 1 15 1 20 Three-Pole QCF1010 QCF2010 -- -- QCF1010T QCF2010T -- -- QCF1015 5 QCF2015 QCF2015H QCF3015H QCF1015T 5 QCF2015T QCF2015HT QCF3015HT QCF1020 5 QCF2020 QCF2020H QCF3020H QCF1020T 5 QCF2020T QCF2020HT QCF3020HT QCF1025 QCF2025 QCF2025H QCF3025H QCF1025T QCF2025T QCF2025HT QCF3025HT QCF2030 QCF2030H QCF3030H 1 25 1 30 QCF1030 1 QCF1030T QCF2030T QCF2030HT QCF3030HT 35 QCF1035 QCF2035 -- -- 1 40 QCF1040 QCF2040 -- -- 1 45 QCF1045 QCF2045 -- -- 50 QCF1050 QCF2050 -- -- 1 55 QCF1055 QCF2055 -- -- 60 6 QCF1060 QCF2060 -- -- 1 QCF Breaker 22 kAIC Interrupting Ratings 15 1 20 1 QCFH1015 5 QCFH2015 -- -- QCFH1015T 5 QCFH2015T -- -- QCFH1020 5 QCFH2020 -- -- QCFH2020T -- -- QCFH1020T 1 5 Notes 1 Standard breaker terminals are box type lugs. 2 Breakers with T Catalog Number Suffix are suitable for line and load side ring terminal connection (#10-32 plus/minus terminal screw provided). 3 Breakers with Shunt Trip Attachment (extra pole required on breaker right-hand side) are available. Contact the Customer Support Center. 4 Breakers with H Catalog Suffix have 240 Vac construction. 5 All 15 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications. 6 60/75C Cu/Al wire on all ratings except 60A, which requires Cu only conductor. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-26 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 QCR and QCF Options and Accessories QCR and QCF Standard Box Terminals Factory-installed line and load side breaker terminal to accommodate14 AWG to 4 AWG wire. Standard Box Terminals 1 QCR and QCF Ring or Spade Lug Terminals (10 to 30A Ratings Only) Factory-installed line and load side terminals each equipped with a #10-32 screw suitable for terminating one 10 AWG wire with insulated ring or spade type terminal as shown. Catalog Suffix "T" QCR Quick-Connect Terminals Factory-installed two-prong quick-connect terminal on breaker load side suitable for terminating two 10 AWG wire with insulated slip-on terminals as shown. Line side terminal is the standard type. Available QCR and QCF Breaker Accessories 1 Catalog Number 1 Steel mounting clip mounts QCR breaker if individual mounting is required. Quantity two required for single- and twopole and four required for three-pole breakers. QCRMTGFT 1 Removable padlock device for single-pole QCR or QCF breaker. QCRFPL1P Removable padlock device for multi-pole QCR or QCF breaker. QCRFPLMP Padlock bracket assembly for QCR or QCF single- or multi-pole breakers (OFF only). QCRFLOFF Padlock bracket for QCR, lock-off only. QCRPLOFF Description 1 1 1 1 1 1 1 1 Catalog Suffix "P" 1 1 1 1 Technical Data and Specifications Single-, two- and three-pole 10 kAIC at 120/240 Vac, 10-60A 22 kAIC at 120/240 Vac, 15-20A 10 kAIC at 240 Vac, 10-30A 3 kAIC at 62.5 Vdc (single-pole) 3 kAIC at 130 Vdc (two poles in series) Normal operating environment: 0-40C 5-95% humidity (noncondensing) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-27 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Contents QUICKLAG Type QCGF Single-Pole Ground Fault Circuit Breaker Description 1 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Product Description Standards and Certifications QUICKLAG Ground Fault Circuit Breakers, Class A GFCI 5 mA trip sensitivity QUICKLAG Ground Fault Circuit Breakers, Class A GFCI Built and tested to UL 943 QUICKLAG Ground Fault Equipment Protectors 30 mA trip sensitivity QUICKLAG Ground Fault Equipment Protectors Built and tested to UL 1053 1 1 1 1 1 1 1 1 1 1 1 V4-T1-28 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Page V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-11 V4-T1-14 V4-T1-17 V4-T1-20 V4-T1-24 V4-T1-29 V4-T1-30 V4-T1-30 V4-T1-31 V4-T1-34 V4-T1-37 V4-T1-40 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Product Selection QUICKLAG Type QCGF Single-Pole Ground Fault Circuit Breaker 1 Breaker Catalog Numbers Continuous Ampere Rating at 40C Single-Pole Two-Pole 120 Vac 120/240 Vac Catalog Number Catalog Number 1 1 1 Ground Fault Circuit Breakers--5 mA Sensitivity QUICKLAG Type: QCGF 10,000A Interrupting Capacity Thermal-Magnetic Breakers 15 QCGF1015 QCGF2015 20 QCGF1020 QCGF2020 25 QCGF1025 QCGF2025 30 QCGF1030 QCGF2030 40 QCGF1040 QCGF2040 50 -- QCGF2050 1 1 1 1 QUICKLAG Type: QCHGF 22,000A Interrupting Capacity Thermal-Magnetic Breakers 15 QCHGF1015 QCHGF2015 20 QCHGF1020 QCHGF2020 25 QCHGF1025 QCHGF2025 30 QCHGF1030 QCHGF2030 1 1 Ground Fault Equipment Protectors--30 mA Sensitivity QUICKLAG Type: QCGFEP 10,000A Interrupting Capacity Thermal-Magnetic Breakers 1 15 QCGFEP1015 QCGFEP2015 20 QCGFEP1020 QCGFEP2020 1 25 QCGFEP1025 QCGFEP2025 30 QCGFEP1030 QCGFEP2030 40 QCGFEP1040 QCGFEP2040 50 -- QCGFEP2050 1 1 1 QUICKLAG Type: QCHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers 15 QCHGFEP1015 QCHGFEP2015 20 QCHGFEP1020 QCHGFEP2020 25 QCHGFEP1025 QCHGFEP2025 30 QCHGFEP1030 QCHGFEP2030 1 1 1 Special Application Ground Fault Circuit Protector--5 mA Sensitivity QUICKLAG Type: QCGF 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2) 15 QCGF1015W1 QCGF2015W1 20 QCGF1020W1 QCGF2020W1 25 QCGF1025W1 QCGF2025W1 30 QCGF1030W1 QCGF2030W1 40 -- QCGF2040W1 50 -- QCGF2050W1 15 QCGF1015W2 -- 20 QCGF1020W2 -- 25 QCGF1025W2 -- 30 QCGF1030W2 -- 1 1 1 1 1 1 Special Application Ground Fault Equipment Protectors--30 mA Sensitivity QUICKLAG Type: QCGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2) 15 QCGFEP1015W1 QCGFEP2015W1 20 QCGFEP1020W1 QCGFEP2020W1 25 QCGFEP1025W1 QCGFEP2025W1 30 QCGFEP1030W1 QCGFEP2030W1 40 -- QCGFEP2040W1 50 -- QCGFEP2050W1 15 QCGFEP1015W2 -- 20 QCGFEP1020W2 -- 25 QCGFEP1025W2 -- 30 QCGFEP1030W2 -- Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1 1 1 1 1 1 V4-T1-29 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1 Wiring Diagram 1 Bell Alarm and Auxiliary Contact Schematic 1 Blue Ground Fault Breaker 1 1 1 1 1 Blue Wire NC Red Black Wire NO Red Wire Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W1)--contacts change state when breaker trips. Auxiliary Switch (W2)--contacts change state when breaker is opened (or tripped) or closed. 14-inch (355.6 mm) long 18 AWG pigtail wire leads provided. Dimensions Approximate Dimensions in Inches (mm) 1 Shipping Data 1 Number of Poles Carton Quantity Approximate Weight Lbs (kg) Dimensions 1 1 20 11.00 (5.0) 12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0) 2 5 5.00 (2.3) 15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-30 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Contents BABRP and BABRSP Breakers-- Single- and Two-Pole Description Page Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers. . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . . V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-11 1 1 1 1 V4-T1-14 1 V4-T1-17 1 V4-T1-20 V4-T1-24 1 V4-T1-28 1 1 V4-T1-32 V4-T1-33 V4-T1-33 1 V4-T1-34 V4-T1-37 V4-T1-40 1 1 1 1 Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP Product Description Application Description Features, Benefits and Functions The BABRP and BABRSP are bolt-on branch circuit breakers designed for use in panelboards. The BRRP is a plug-on branch circuit breaker designed for use in loadcenters not manufactured with breakers with a 1-inch wide format and are listed on the "Compatibility list for Classified Applications"-- Pub. 26271. In addition to providing conventional branch circuit protection, they include a unique solenoid-operated mechanism that provides for efficient breaker pulse-on and pulse-off operation when used with a suitable controller like Eaton's Pow-R-CommandTM lighting control system. These breakers can also be controlled by pushbutton or a PLC unit. Eaton's BABRP, BABRSP, BRRP and CLRP breakers are remotely operated molded case circuit breakers ideally suited for lighting control applications or energy management applications. Bolt-on line-side terminal (BABRP, BABRSP-- Type BA) Plug-on line-side terminal (BRRP--Type BR, CLRP-- Type CL) Cable connected load-side terminal Four-position control terminal Bi-metal assembly for thermal overload protection Fast-acting short-circuit protection Arc-chute assembly for fast-acting arc extinction Three-position handle: OFF, TRIP (Center), ON 1 Handle permits manual switching when control power is lost Mechanical trip indicator 15 and 20A breakers SWD (switching duty) rated HID ratings for HID (high intensity discharge) lighting All models HACR rated Status feedback of control circuit (BABRSP) Series rated (BABRP, BABRSP only) BRRP series rated same as BR breakers BABRP, BABRSP same as BA breakers 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-31 1.1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Product Selection QUICKLAG Type QCGF Single-Pole Ground Fault Circuit Breaker BABRP UL 489 and CSA 22.2 Interrupting Ratings BRRP UL 489 and CSA 22.2 Interrupting Ratings Interrupting Capacity (Symmetrical Amperes) Interrupting Capacity (Symmetrical Amperes) 1 Catalog Number Ampere Vac (50/60 Hz) 120/240 277/480 Number of Poles Rating 1 120 Number Ampere of Poles Rating Vac (50/60 Hz) 120 120/240 Catalog Number 1 1 1 15 10,000 -- -- BABRP1015 15 10,000 -- BRRP115 20 10,000 -- -- BABRP1020 20 10,000 -- BRRP120 25 10,000 -- -- BABRP1025 25 10,000 -- BRRP125 30 10,000 -- -- BABRP1030 30 10,000 -- BRRP130 15 -- 10,000 -- BABRP2015 15 -- 10,000 BRRP215 1 20 -- 10,000 -- BABRP2020 20 -- 10,000 BRRP220 25 -- 10,000 -- BABRP2025 25 -- 10,000 BRRP225 1 30 -- 10,000 -- BABRP2030 30 -- 10,000 BRRP230 1 1 2 1 BABRP and BABRSP Wire Harness 1 Catalog Number Description 1 This 60-inch (1524.0 mm) wire pigtail provides SLBKRPTL1 a connection from a single BABRP's control plug to a customer's pushbutton, relay or PLC. Each box contains 12 pigtails. Wires are 22 AWG, 600V. Order in multiples of 12. 1 2 CLRP UL 489 and CSA 22.2 Interrupting Ratings Interrupting Capacity (Symmetrical Amperes) Number Ampere of Poles Rating 1 1 BABRSP UL 489 and CSA 22.2 Interrupting Ratings 1 1 Interrupting Capacity (Symmetrical Amperes) Vac (50/60 Hz) Number Ampere of Poles Rating 1 120 1 1 Catalog 120/240 277/480 Number 15 10,000 -- -- BABRSP1015 1 20 10,000 -- -- BABRSP1020 1 25 10,000 -- -- BABRSP1025 30 10,000 -- -- BABRSP1030 15 -- 10,000 -- BABRSP2015 20 -- 10,000 -- BABRSP2020 25 -- 10,000 -- BABRSP2025 30 -- 10,000 -- BABRSP2030 2 1 1 2 120/240 Catalog Number 15 10,000 -- CLRP115 20 10,000 -- CLRP120 25 10,000 -- CLRP125 30 10,000 -- CLRP130 15 -- 10,000 CLRP215 20 -- 10,000 CLRP220 25 -- 10,000 CLRP225 30 -- 10,000 CLRP230 Note 1 Continuous current rating at 40C. 1 1 1 1 1 1 1 1 1 V4-T1-32 Vac (50/60 Hz) 120 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Technical Data and Specifications 1 1 Control Circuit for the BABRP and BABRSP BABRP BABRSP Remote Contact Remote Contact Line Load Breaker Contact RM a 1 BKR a Red Black Off Remote Coil Status Blue Yellow RM b On Coil Off Remote Coil Status 1 1 Blue RM a On Coil 1 Line Breaker Contact RM b 1 Yellow Load Black Operation Tripping system--the BABRP, BABRSP, BRRP and CLRP circuit breakers have a permanent trip unit that contains a factory preset thermal (overload) trip element in each pole Operating mechanism-- the BABRP, BABRSP, BRRP and CLRP circuit breakers have an over-center toggle mechanism that provides quick-make, quick-break operation. The operating mechanism is trip free. An internal cross-bar provides a common tripping of all multi-pole circuit breakers Red Solenoid Operating Data Power requirements: 24 Vac/dc (20.4V minimum- 30V maximum) Controlled signal: +AC/DC 8 ms minimum with zero cross, 300 ms maximum AC: 1.3 cycles minimum, 18 cycles or 300 ms maximum DC: 8 ms minimum, 300 ms maximum Maximum duty cycle of 6 OPEN/CLOSE cycles per minute Current draw: open 1A, close 3/4A Blue wire: power input (see power requirements) Black wire: remote opening Red wire: remote closing Yellow wire: feedback status from power input, maximum 0.50A draw (BABRSP only) Wiring Diagrams 1 1 1 Operating/Application Data Ambient temperature: 0 to 40C Nominal pulse magnitude: 24 Vac/dc Frequency: 50/60 Hz Maximum breaker cycling: 6 operations per minute Tolerance: +10% to -15% of nominal voltage Humidity: 0 to 95% noncondensing 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-33 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Contents GHBS and GHQRSP Description 1 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC . . . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Solenoid Operator--Remote-Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers Product Description Eaton's GHBS, GBHS and GHQRSP circuit breakers are bolt-on branch circuit breakers designed for use in 277/480 Vac panelboards. In addition to providing conventional branch circuit protection, they include a unique solenoid-operated mechanism that provides for efficient breaker pulse-on and pulse-off operation when used with a suitable controller like Eaton's Pow-R-Command lighting control system. Features, Benefits and Functions 1 Bolt-on line-side terminal Cable-connected load-side terminal Status switch--remote status and breaker status available from internal auxiliary switches Bi-metal assembly for thermal overload protection Fast-acting short-circuit protection Arc-runner and arc-chute assembly for fast-acting arc extinction Three-position breaker handle: OFF, TRIP (Center), ON Visual indication of the remotely operated contact's position (open, closed or trip) Remote override handle permits manual switching when control power is lost 15 and 20A breakers SWD (switching duty) rated. 15 and 20A breakers HID rated for HID (High intensity discharge) lighting All models HACR rated Series rated with various Eaton main circuit breakers 1 1 1 1 1 1 V4-T1-34 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Page V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-11 V4-T1-14 V4-T1-17 V4-T1-20 V4-T1-24 V4-T1-28 V4-T1-31 V4-T1-35 V4-T1-36 V4-T1-36 V4-T1-37 V4-T1-40 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Product Selection GHBS--Single-Pole 1 1 GHBS UL 489 Interrupting Ratings 1 Interrupting Capacity (Symmetrical Amperes) Number of Poles Ampere Rating 1 Vac (50/60 Hz) 120 240 277/480 Catalog Number 1 15 65,000 -- 14,000 GHBS1015D 20 65,000 -- 14,000 GHBS1020D 30 65,000 -- 14,000 GHBS1030D 15 -- 65,000 14,000 GHBS2015D 20 -- 65,000 14,000 GHBS2020D 30 -- 65,000 14,000 GHBS2030D 2 1 1 1 1 1 GBHS CSA 22.2 Interrupting Ratings (Not UL Listed) 1 Interrupting Capacity (Symmetrical Amperes) Number of Poles 1 2 Ampere Rating 1 1 Vac (50/60 Hz) 347/600 Catalog Number 15 10,000 GBHS1015D 20 10,000 GBHS1020D 15 10,000 GBHS2015D 20 10,000 GBHS2020D 1 1 1 1 GHQRSP UL 489 and CSA 22.2 Interrupting Ratings Interrupting Capacity (Symmetrical Amperes) Number of Poles Ampere Rating 1 Vac (50/60 Hz) 120 120/240 277 480Y/277 Catalog Number 2 1 15 65,000 65,000 14,000 14,000 GHQRSP1015 20 65,000 65,000 14,000 14,000 GHQRSP1020 30 65,000 65,000 14,000 14,000 GHQRSP1030 15 65,000 65,000 14,000 14,000 GHQRSP2015 20 65,000 65,000 14,000 14,000 GHQRSP2020 30 65,000 65,000 14,000 14,000 GHQRSP2030 2 1 1 1 1 1 1 Notes 1 Continuous current rating at 40C. 2 All UL listed circuit breakers are HID (high intensity discharge) rated. 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-35 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1 Technical Data and Specifications 1 1 Solenoid Operating Data Power requirements: 24 Vac/dc (20.4V minimum- 30V maximum) Controlled signal: +AC/ DC 8 ms minimum with zero cross, 300 ms maximum AC: 1.3 cycles minimum, 18 cycles or 300 ms maximum DC: 8 ms minimum, 300 ms maximum Maximum duty cycle of 6 OPEN/CLOSE cycles per minute Current draw: open 1A, close 3/4A Blue wire: power input (see power requirements) Black wire: remote opening 1 Terminal Type 1 Circuit Breaker Type Circuit Breaker Amperes Screw Head Type Terminal Type Range 1 GHQRSP 15-20 Slotted Clamp #14-#4 AWG 1 1 1 1 1 1 1 1 Wiring Diagrams Red wire: remote closing Yellow wire: feedback status from power input, maximum 0.50A draw Operation Mechanism manually operated by external handle allowing ON, OFF and RESET operation. Handle assumes a center TRIP position after performing protective response. Operating/Application Data Ambient temperature: 0-40C Frequency: 48-62 Hz Humidity: 0-95% noncondensing Typical Single-Pole Circuit Breaker Schematic Diagram for GHBS and GBHS Breakers Circuit Breaker Solenoid Common AMP Inc. Conductor Plug 1 a Solenoid Auxiliary / Cycle Maximum 28 Vac Pulse Source 1 2 28 Vac Circuit Breaker Open/Closed Status Typical Single-Pole Circuit Breaker Schematic Diagram for GHQRSP Breakers GHQRSP Remote Breaker Contact Contact Load Line 1 Blue 1 Black Yellow 1 Red 1 On Coil Off Coil Power Input Status 1 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 Dimensions per Pole 1 1 Circuit Breaker Type Width Height 2 Length 3 GHQRSP 1.00 (25.4) 4.63 (117.6) 2.81 (71.4) Notes 1 Purchase separate AMP Inc. conductor plug #640426-3. 2 Excluding line terminal. 3 Excluding handle. 1 1 1 1 1 1 V4-T1-36 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Contents International Rated Description Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers. . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Special Application Breakers, Types HQP, BA, QC . . . . Page V4-T1-2 V4-T1-5 V4-T1-8 V4-T1-11 1 1 1 1 V4-T1-14 1 V4-T1-17 1 V4-T1-20 V4-T1-24 1 V4-T1-28 1 V4-T1-31 1 V4-T1-34 1 V4-T1-38 V4-T1-39 V4-T1-39 V4-T1-40 1 1 1 International Rated Types HQP, BA, QC, GFMB, GFXBC 1 Product Description Standards and Certifications 1 QUICKLAG International Circuit Breakers Bolt-on Type BA QUICKLAG International Circuit Breakers Built and test certified to BS3871, Pt. 1 50/60 Hz, 40C 1 QUICKLAG International Ground Fault Circuit Breakers Plug-on Type GFMB Cable-in/cable-out Type GFXBC 1 1 QUICKLAG International Ground Fault Circuit Breakers Built and test certified to BS3871, Pt. 1; BS3871, Section 31-C; BS4293 50/60 Hz, 40C; 30 mA sensitivity 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-37 1.1 1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Product Selection BAB Breaker Catalog Numbers Single-Pole Two-Pole Three-Pole 240/415 Vac 240/415 Vac 240/415 Vac Catalog Number Catalog Number Catalog Number 1 Continuous Ampere Rating at 40C 1 3000A Interrupting Capacity (M3) Bolt-On Thermal-Magnetic Circuit Breakers 1 10 BAB1010E BAB2010E 15 BAB1015E BAB2015E BAB3015E 1 16 -- -- -- 20 BAB1020E BAB2020E BAB3020E 1 25 BAB1025E BAB2025E BAB3025E 30 BAB1030E BAB2030E BAB3030E 1 32 -- -- -- 1 40 BAB1040E BAB2040E BAB3040E 50 BAB1050E BAB2050E BAB3050E 1 60 BAB1060E BAB2060E BAB3060E 70 BAB1070E BAB2070E BAB3070E 1 90 -- BAB2090E BAB3090E 1 100 -- BAB2100E BAB3100E 6000A Interrupting Capacity (M6) Bolt-On Thermal-Magnetic Circuit Breakers BAB3010E 1 15 BAB1015HE BAB2015HE BAB3015HE 20 BAB1020HE BAB2020HE BAB3020HE 1 25 BAB1025HE BAB2025HE BAB3025HE 30 BAB1030HE BAB2030HE BAB3030HE 1 40 BAB1040HE BAB2040HE BAB3040HE 1 50 BAB1050HE BAB2050HE BAB3050HE 60 BAB1060HE BAB2060HE BAB3060HE 1 70 BAB1070HE BAB2070HE BAB3070HE 90 -- BAB2090HE BAB3090HE 1 100 -- BAB2100HE BAB3100HE 1 Breaker Catalog Numbers--Ground Fault Single-Pole 30 mA Sensitivity 1 Continuous Ampere Rating at 40C 1 240/415 Vac Catalog Number 3000A Interrupting Capacity (M3) Plug-On Thermal-Magnetic Circuit Breakers 1 10 GFMB110B2 1 15 GFMB115B2 16 GFMB116B2 1 20 GFMB120B2 25 GFMB125B2 1 30 GFMB130B2 32 GFMB132B2 1 40 GFMB140B2 1 Note For other 240/415V applications, please contact the Customer Support Center at 1-800-356-1243. 1 1 1 V4-T1-38 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Technical Data and Specifications 1 Interrupting Ratings Ratings Suffix E 1 Suffix HE 1 International Circuit Breakers NEMA(R) 120/240 Vac 10,000 AIC 10,000 AIC BS3871 220/380, 240/415 Vac 3000 AIC 6000 AIC 1 1 International Ground Fault Circuit Breakers BS3871 220/380, 240/415 Vac 1 3000 AIC 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 Shipping Data Miniature Circuit Breaker QUICKLAG Type B Number of Poles Standard Carton Quantity Approximate Carton Weight Lbs (kg) 1 Approximate Standard Carton 1 1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 1 20 11.00 (5.0) 12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0) 1 QUICKLAG Ground Fault Type P--All 1 Types B and C--All 1 20 11.00 (5.0) 12.50 x 7.00 x 5.50 (317.5 x 177.8 x 139.7) Types P and B--All 2 5 5.00 (2.3) 12.50 x 6.00 x 4.50 (317.5 x 152.4 x 114.3) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-39 1.1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Contents QUICKLAG Type P Switching Neutral Description Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . Solenoid Operator--Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers . . . . . . . International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Factory Modifications and Installed Terminals . . Technical Data and Specifications . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 1 1 1 1 1 1 1 1 1 Special Application Breakers, Types HQP, BA, QC 1 Product Description 1 Breakers Plug-on Type HQP: 10-30A, single- and two-pole, 10 kAIC Bolt-on Type BA: 10-30A, single- and two-pole, 10 kAIC Cable-in Type QC: 10-30A, single- and two-pole, 10 kAIC 1 1 1 1 1 1 1 1 1 QUICKLAG HID (High Intensity Discharge) Breakers Plug-on Type HQP: 15-60A, single- and two-pole, 10 kAIC Bolt-on Type BA: 15-60A, single- and two-pole, 10 kAIC Cable-in Type QC: 15-60A, single- and two-pole, 10 kAIC Breakers designed specifically for use with high intensity discharge (HID) lighting applications. (UL listed as standard lighting breakers.) Molded Case Switches--Nonautomatic QUICKLAG Molded Case Switch Plug-on Type HQP: 50, 60,100A, single-, two- and three-pole Bolt-on Type BA: 50, 60,100A, single-, two- and three-pole Cable-in Type QC: 50, 60,100A, single-, two- and three-pole 1 1 1 1 1 V4-T1-40 V4-T1-8 V4-T1-11 V4-T1-14 V4-T1-17 V4-T1-20 V4-T1-24 V4-T1-28 V4-T1-31 V4-T1-34 V4-T1-37 V4-T1-41 V4-T1-43 V4-T1-46 V4-T1-47 V4-T1-48 Standards and Certifications Switching neutral QUICKLAG breakers available in singleand two-pole configurations, plus neutral pole for applications in accordance with NEC(R) 514.5, 240.22 and 380.2. A single-pole device takes two pole spaces, and a two-pole device takes three pole spaces. Page V4-T1-2 V4-T1-5 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com All products UL and CSA listed Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1.1 Product Selection QUICKLAG Type P Switching Neutral 1 1 Breaker Catalog Numbers Continuous Ampere Rating at 40C Single-Pole Two-Pole Two-Pole Three-Pole 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 1 1 QUICKLAG Type: HQP Switching Neutral Thermal-Magnetic Breakers 10 HQP2010B HQP3010B -- -- 15 HQP2015B HQP3015B -- -- 20 HQP2020B HQP3020B -- -- 25 HQP2025B HQP3025B -- -- 30 HQP2030B HQP3030B -- -- 1 1 1 1 QUICKLAG Type: BA Switching Neutral Thermal-Magnetic Breakers 10 BAB2010C BAB3010C -- -- 15 BAB2015C BAB3015C -- -- 20 BAB2020C BAB3020C -- -- 25 BAB2025C BAB3025C -- -- 30 BAB2030C BAB3030C -- -- 1 1 1 QUICKLAG Type: QC Switching Neutral Thermal-Magnetic Breakers 10 QC2010B QC3010B -- -- 15 QC2015B QC3015B -- -- 20 QC2020B QC3020B -- -- 25 QC2025B QC3025B -- -- 30 QC2030B QC3030B -- -- 1 1 1 QUICKLAG Type: HQP HID (High Intensity Discharge) Thermal-Magnetic Breakers 15 HQP1015D HQP2015D -- -- 20 HQP1020D HQP2020D -- -- 25 HQP1025D HQP2025D -- -- 30 HQP1030D HQP2030D -- -- 35 HQP1035D HQP2035D -- -- 40 HQP1040D HQP2040D -- -- 50 HQP1050D HQP2050D -- -- 60 HQP1060D HQP2060D -- -- 1 1 1 1 1 QUICKLAG Type: BA HID (High Intensity Discharge) Thermal-Magnetic Breakers 15 BAB1015D BAB2015D -- -- 20 BAB1020D BAB2020D -- -- 25 BAB1025D BAB2025D -- -- 30 BAB1030D BAB2030D -- -- 35 BAB1035D BAB2035D -- -- 40 BAB1040D BAB2040D -- -- 50 BAB1050D BAB2050D -- -- 60 BAB1060D BAB2060D -- -- 1 1 1 1 1 1 QUICKLAG Type: QC HID (High Intensity Discharge) Thermal-Magnetic Breakers 15 QC1015D QC2015D -- -- 20 QC1020D QC2020D -- -- 25 QC1025D QC2025D -- -- 30 QC1030D QC2030D -- -- 35 QC1035D QC2035D -- -- 40 QC1040D QC2040D -- -- 50 QC1050D QC2050D -- -- 60 QC1060D QC2060D -- -- 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-41 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1 Breaker Catalog Numbers, continued Single-Pole Two-Pole Two-Pole 1 Continuous Ampere Rating at 40C 120/240 Vac 120/240 Vac 240 Vac 240 Vac Catalog Number Catalog Number Catalog Number Catalog Number 1 QUICKLAG Type: HQP Non-Automatic Switches 1 50 HQP1050N -- HQP2050N HQP3050N 60 HQP1060N -- HQP2060N HQP3060N 1 100 HQP1100N -- HQP2100N HQP3100N 1 50 BAB1050N -- BAB2050N BAB3050N 60 BAB1060N -- BAB2060N BAB3060N 1 100 BAB1100N -- BAB2100N BAB3100N 1 50 QC1050N -- QC2050N QC3050N 1 60 QC1060N -- QC2060N QC3060N 100 QC1100N -- QC2100N QC3100N 1 QUICKLAG Type: QCD Non-Automatic Switches 1 60 -- -- QCD2060NA -- 100 -- -- -- -- Three-Pole QUICKLAG Type: BA Non-Automatic Switches QUICKLAG Type: QC Non-Automatic Switches 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-42 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Accessories 1 1 1 Handle Locks: Non-Padlockable 2 QL1NPL Description Order in Multiples of Catalog Number QUICKLAG Type P, B, C--single-pole 10 QL1NPL 1 1 1 1 QL23NPL QUICKLAG Type P, B, C--two- and three-pole 10 1 QL23NPL 1 1 1 1 1 Handle Locks: Padlockable 2 QL1PL Description Order in Multiples of Catalog Number QUICKLAG Type P, B, C--single-pole 10 QL1PL 1 1 1 1 1 QL123PL QUICKLAG Type P, B and ground fault--single-, two- and three-pole 10 1 QL123PL 1 1 1 QC123PL QUICKLAG Type C --single-, two- and three-pole 10 1 QC123PL 1 1 1 QUICKLAG Type P, B--single-, two- and three-pole (off only) 10 QL123PLOFF QUICKLAG Type C--single-, two- and three-pole (off only) 10 QC123PLOFF 1 1 Notes 1 See Page V4-T1-27 for QCR and QCF accessories. 2 Can lock in ON or OFF position. 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-43 1.1 Industrial Circuit Breakers Mounting Hardware 1 1 Miniature Circuit Breakers and Supplementary Protectors Description Order in Multiples of Catalog Number QCFCLIP QUICKLAG Type C face mounting clip 24 QCFCLIP QC1FP QUICKLAG Type C face mounting plate--single-pole 10 QC1FP QC2FP QUICKLAG Type C face mounting plate--two-pole 10 QC2FP QC3FP QUICKLAG Type C face mounting plate--three-pole 10 QC3FP QUICKLAG Type C face mounting plate and lock-off (off only)--two-pole 1 10 QC2FPLOFF QUICKLAG Type C face mounting plate and lock-off (off only)--three-pole 10 QC3FPLOFF QCBCLIP QUICKLAG Type C base mounting clamp 10 QCBCLIP QC6BP QUICKLAG Type mounting plate--six poles total 10 QC6BP 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Note 1 Suitable for ground fault breakers. 1 1 V4-T1-44 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Mounting Hardware, continued Description QCDJ4 Order in Multiples of Catalog Number QUICKLAG Type C base mounting plate--six poles total--heavy-duty screw-secured 10 QC6BPS QUICKLAG Type C (QCD) 2-way jumper unit with cover 10 QCDJ2 QUICKLAG Type C (QCD) 4-way jumper unit with cover 10 QCDJ4 1 1 1 1 1 QCDINADAPT 1 QUICKLAG Type C (QCD) 6-way jumper unit with cover 10 QCDJ6 QUICKLAG Type C (QCD) 2-way jumper unit, no cover 10 QCDJ2T QUICKLAG Type C (QCD) 4-way jumper unit, no cover 10 QCDJ4T QUICKLAG Type C (QCD) 6-way jumper unit, no cover 10 QCDJ6T QUICKLAG Type QCD Finger protection attachment 10 QCDFP QUICKLAG Type QCD 4-prong Quick Connect 10 QCDQUICK QUICKLAG Type C DIN rail adapter 6 QCDINADAPT 1 1 1 1 1 QCDRING QUICKLAG Type QCD ring lug attachment 10 1 QCDRING 1 1 1 1 Dummy Breakers Description Order in Multiples of Catalog Number QUICKLAG Type P 1 HQP1000 QUICKLAG Type B 1 BAB1000 QUICKLAG Type C 1 QC1000 QUICKLAG Type C clear choice breaker 4 QC30SAMPLE 1 1 1 1 QCRSPACER Miscellaneous Description Order in Multiples of Catalog Number QUICKLAG Type C Spacer 1 QCRSPACER 1 1 1 1 1 QL1HT Handle Tie Description Order in Multiples of Catalog Number QUICKLAG handle tie--single-pole 100 QL1HT 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-45 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers 1 Factory Modifications and Installed Terminals 1 Factory Modifications 1 Type of Modification Breaker Type Catalog Suffix Shunt trip (requires one extra pole space on right side) 120, 208, 240 Vac Draws 2.6A at 120V, draws 11A at 24 Vdc QUICKLAG Types P, B and C S Shunt trip (requires one extra pole space on right side) 24, 48 Vac/dc Draws 2.6A at 120V, draws 11A at 24 Vdc QUICKLAG Types P, B and C S1 Special calibration (50C) (no UL) QUICKLAG Types P, B and C V Shock testing QUICKLAG Types P, B and C L 1 Freeze testing QUICKLAG Types P, B and C Y Moisture-fungus treatment QUICKLAG Types P, B, C and ground fault F 1 Marine duty QUICKLAG Types P, B, C H08 1 Naval duty QUICKLAG Types P, B, C H09 400 Hz calibration QUICKLAG Types P, B, C G Specific DC ratings (breaker marked with a max. Vdc rating) QUICKLAG Types P, B, C Q thru Q9 2 1 1 1 1 1 1 Spare Terminal Hardware Screws (Lugs not Included) Terminal Type Description Order in Multiples of Catalog Number 1 QUICKLAG terminal screw 10 QLLDTSA 1 2 QUICKLAG terminal screw 10 QLLDTSB 1 3 QUICKLAG terminal screw 10 QLLDTSC 5 QUICKLAG binding head terminal screw and clamp 10 QLBHTSE 6 and 7 QUICKLAG terminal screw 10 QLLNTSFG 1 1 1 Notes 1 Contact Eaton for factory modifications available for QCR and QCF breakers. 2 Q = 32 Vdc; Q1 = 32-40 Vdc; Q2 = 37.5 Vdc; Q3 = 45 Vdc; Q4 = 48 Vdc; Q5 = 50 Vdc; Q6 = 62.5 Vdc; Q7 = 75 Vdc (2P); Q8 = 80 Vdc (2P); Q9 = 125 Vdc (QCR 2P); Q10 = 62.5 Vdc (QCR 1P). 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-46 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Technical Data and Specifications 1 Factory-Installed Breaker Terminals Breaker Type QUICKLAG Type P HQP, QPHW, QHPX, QHPW Continuous Ampere Rating Standard Line Terminal Standard Load Terminal Terminal Wire Type Type Terminal Type Wire Type Wire Range (AWG) Line 10-30 Plug-on female clips that mate with the bus stabs 1 Cu/Al 14-4 N/A 3 2 Cu/Al 14-4 N/A 3 3 Cu/Al 8-1/0 N/A -- Plug-on female clips that mate with the bus stabs 1 (single-pole) Cu/Al 14-4 N/A 3 1 Cu/Al -- N/A 3 1 Cu 14-8 N/A -- Extended tangs that bolt directly to the bus 1 (single- and two-pole) Cu/Al 14-4 N/A 3 2 (three-pole) Cu/Al 14-4 N/A 3 3 Cu/Al 8-1/0 N/A -- 1 (single-pole) Cu/Al 14-4 N/A N/A 35-50 Wire Range (AWG) 55-125 QUICKLAG ground fault QPGF, QPGFEP, QPHGF, QPHGFEP 10-40 10-40 10-30 QUICKLAG Type B BAB, QBHW, HBAX, HBAW 10-40 35-50 55-125 QUICKLAG ground fault QBGF, QBGFEP, QBHGFEP, QBHGF 10-40 10-40 Extended tangs that bolt directly to the bus 10-30 QUICKLAG Type C QC, QCHW, QHCX, QHCW Optional Terminals Load 1 Cu/Al 14-8 N/A N/A 1 Cu 14-8 N/A N/A 1 1 1 1 Cu/Al TBD 5 Cu/Al 14-10 6, 7 6, 7, 8 6 Cu/Al TBD 2 Cu/Al 14-4 5, 7 5, 6, 7, 8 7 Cu/Al TBD 3 Cu/Al 8-1/0 5 5, 7, 8 1 Cu/Al TBD 1 Cu/Al 14-4 N/A N/A 60 1 Cu TBD 1 Cu 14-4 N/A N/A QUICKLAG ground fault QCGF, QCGFEP, QCHGF, QCHGFEP 10-20 6 Cu/Al TBD 14-8 Cu/Al 14-4 6, 7 5 25-50 6 Cu/Al TBD 1 Cu/Al 14-4 5, 7 5 10-30 6 -- -- -- -- -- -- -- 10-60 9 Cu/Al 14-4 9 Cu/Al 14-4 See Accessories 70-100 10 Cu 4-1/0 10 Cu 4-1/0 See Accessories 1 1 5 10-55 QUICKLAG QCD 1 25-60 70-100 2 3 1 1 10-20 QUICKLAG QCR, QCF 1 1 1 1 1 1 1 1 5 1 1 Steel Box Lug 6 Steel Box Lug 7 Steel Box Lug 8 1 Steel Ring Type 9 1 10 1 4-Prong Quick Connect Aluminum Box Lug Aluminum Box Lug QCD Terminal Assembly 10-60A QCD Terminal Assembly 70-100A 1 1 Note 1 Clamp on line side only. 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-47 1.1 1 1 1 1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors Industrial Circuit Breakers Dimensions Approximate Dimensions in Inches (mm) Shipping Data Miniature Circuit Breaker Number of Poles Standard Carton Quantity Approximate Carton Weight Lbs (kg) Approximate Standard Carton QUICKLAG Types B, P, C-all 1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) QUICKLAG Types B, P, C-all 2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) QUICKLAG Types B, P, C-all 3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) QUICKLAG ground fault Type P-all 1 20 11.00 (5.0) 12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0) Types B and C-all 1 20 11.00 (5.0) 12.50 x 7.00 x 5.50 (317.5 x 177.8 x 139.7) Types P and B-all 2 5 5.00 (2.3) 12.50 x 6.00 x 4.50 (317.5 x 152.4 x 114.3) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-48 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1.2 Contents FAZ-NA Circuit Breakers Description Page FAZ-NA Circuit Breakers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . WMZ Circuit Breaker. . . . . . . . . . . . . . . . . . . . . . . V4-T1-50 V4-T1-51 V4-T1-55 V4-T1-57 V4-T1-66 V4-T1-67 1 1 1 1 1 1 1 1 Optimum and Efficient Protection for Every Application 1 1 1 FAZ-NA Circuit Breakers Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eaton's FAZ-NA DIN rail mountable circuit breaker is designed for use in branch service applications. Powerful Offering for Machine and System Builders The FAZ-NA is available with B, C and D characteristics in accordance with UL(R) 489, CSA(R) C22.2 No.5; UL 1077, CSA C22.2 No.235 and IEC 60947-2. These devices are CE marked. Application Description Feeder and branch circuit protection for: Convenience receptacle circuits (internal/external) Motor control circuits Load circuits leaving the equipment (external) HACR internal/external equipment (heating, air conditioning, refrigeration) PLC I/O points Computers Power supplies Control instrumentation Relays UPS Power conditioners Complete range of UL 489 listed DIN rail mounted miniature circuit breakers up to 40A current rating Standard ratings of 10 kAIC up to 277/480 Vac Select amperages available at 14 kAIC up to 277/480 Vac and 10 kAIC up to 125 Vdc per pole Fulfill UL 489, CSA C22.2 No.5 and also IEC 60947-2 Standard For use in applications for which UL 1077 or CSA C22.2 No.235 are also allowed Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit Suitable for branch circuit device protection Thermal-magnetic overcurrent protection Three levels of shortcircuit protection, categorized by B, C and D curves Trip-free design--breaker can not be defeated by holding the handle in the ON position SWD (switching duty)-- suitable for switching fluorescent lighting loads (In 20A) Field-installable shunt trip and auxiliary switch subsequent mounting Separate version for ringtongue connection (Type FAZ-RT), terminal screws can be removed (on both sides) Module width of only 17.7 mm (per pole) Contact Position Indicator (red/green) Easy installation on DIN rail Possibility for sealing the toggle in ON or OFF position 1 Device Printing on Front and Side Installation options 1 These branch circuit breakers are available in two terminal configurations: standard box terminals that accept multiple conductors and ring-tongue terminals, ideally suited to demanding requirements of the semi-conductor industry. All breakers mount on standard 35 mm DIN rail. Bus connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies. These circuit breakers can also be reverse feed. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Captive screws cannot be lost 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-49 1.2 1 1 1 FAZ-NA complies with the latest national and international standards. 1 1 1 1 UL 489 Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection Products meet the requirements of the National Electrical Code(R) (NEC(R)) CSA C22.2 No.5 Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection (corresponds closely to UL 489 Standard) Products meet the requirements of the Canadian Electrical Code (CEC) 1 1 1 1 UL 489 DIN Rail Miniature Circuit Breakers Standards and Certifications 1 1 Miniature Circuit Breakers and Supplementary Protectors RoHS compliant VDE compliant ABS compliant Catalog Number Selection 1 FAZ C 6 / 1 NA SP 1 Breaker Family 1 FAZ = FAZ UL circuit breaker Single Package Trip Characteristics 1 B = 3-5X In C = 5-10X In D = 10-20X In 1 1 1 1 1 1 Terminal Ampere Rating 2 0.5 = 1 = 1.5 = 2 = 3 = 4 = 5 = 6 = 7 = 8 = 0.5A 1A 1.5A 2A 3A 4A 5A 6A 7A 8A 10 = 10A 13 = 13A 15 = 15A 16 = 16A 20 = 20A 25 = 25A 30 = 30A 32 = 32A 35 = 32A 40 = 40A Number of Poles 1 = Single-pole 2 = Two-pole 3 = Three-pole Notes 1 I = Rated current for instantaneous trip characteristics. n 2 B curve starts at 1 ampere. 1 1 1 1 1 1 1 1 V4-T1-50 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com NA = UL 489 branch circuit with screw terminals RT = UL 489 branch circuit with ring tongue terminals DC = UL 489 branch circuit at 125 Vdc per pole SP = Single package for C and D curve single-pole only Blank = Standard packaging 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1 1.45 FAZ-NA B Curve UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as branch circuit breakers Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947-2 Current limiting device UL file number E235139 1.13 Product Selection 2.55 I : N 1 Type B: 3 x I : t > 0.1 s N 1 7200 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1200 600 t = 1-60 s (IN < 32A) t = 1-120 s (IN > 32A) Specified tripping current IT = 1.45 x IN for t < 1 h 300 Type B: 5 x I : t < 0.1 s N 1 120 1 60 1 30 1 t [sec] 10 5 1 2 1 1 0.5 1 0.2 3 0.1 1 B 2 0.05 0.02 1 0.01 0.005 1 0.002 0.001 1 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 30 40 50 1 I / IN Single-Pole FAZ-NA UL 489 Circuit Breakers--10 kAIC, 14 kAIC B Curve (15-25A) Single-Pole 1 Catalog Amperes Number Two-Pole Three-Pole Catalog Number Catalog Number Single-Pole Single-Pole 1 Two-Pole Catalog Amperes Number B Curve (3-5X In Current Rating) Two-Pole Three-Pole 1 FAZ-B1/1-NA FAZ-B1/2-NA 1.5 FAZ-B1.5/1-NA FAZ-B1.5/2-NA FAZ-B1.5/3-NA 2 FAZ-B2/1-NA FAZ-B2/2-NA FAZ-B2/3-NA 3 FAZ-B3/1-NA FAZ-B3/2-NA FAZ-B3/3-NA 4 FAZ-B4/1-NA FAZ-B4/2-NA FAZ-B4/3-NA 5 FAZ-B5/1-NA FAZ-B5/2-NA FAZ-B5/3-NA 6 FAZ-B6/1-NA FAZ-B6/2-NA FAZ-B6/3-NA 7 FAZ-B7/1-NA FAZ-B7/2-NA FAZ-B7/3-NA 8 FAZ-B8/1-NA FAZ-B8/2-NA FAZ-B8/3-NA 10 FAZ-B10/1-NA FAZ-B10/2-NA FAZ-B10/3-NA FAZ-B13/1-NA FAZ-B13/2-NA FAZ-B13/3-NA 15 FAZ-B15/1-NA FAZ-B15/2-NA FAZ-B15/3-NA 16 FAZ-B16/1-NA FAZ-B16/2-NA FAZ-B16/3-NA 20 FAZ-B20/1-NA FAZ-B20/2-NA FAZ-B20/3-NA 25 FAZ-B25/1-NA FAZ-B25/2-NA FAZ-B25/3-NA 30 FAZ-B30/1-NA FAZ-B30/2-NA FAZ-B30/3-NA 32 FAZ-B32/1-NA FAZ-B32/2-NA FAZ-B32/3-NA 35 2 FAZ-B35/1-NA FAZ-B35/2-NA FAZ-B35/3-NA 2 FAZ-B40/1-NA FAZ-B40/2-NA FAZ-B40/3-NA 40 Catalog Number Two-Pole Three-Pole FAZ-B1/2-RT 1 Catalog Number 1 1 1 FAZ-B1/1-RT 1.5 FAZ-B1.5/1-RT FAZ-B1.5/2-RT FAZ-B1.5/3-RT 2 FAZ-B2/1-RT FAZ-B2/2-RT FAZ-B2/3-RT 3 FAZ-B3/1-RT FAZ-B3/2-RT FAZ-B3/3-RT 4 FAZ-B4/1-RT FAZ-B4/2-RT FAZ-B4/3-RT 5 FAZ-B5/1-RT FAZ-B5/2-RT FAZ-B5/3-RT 6 FAZ-B6/1-RT FAZ-B6/2-RT FAZ-B6/3-RT 7 FAZ-B7/1-RT FAZ-B7/2-RT FAZ-B7/3-RT 8 FAZ-B8/1-RT FAZ-B8/2-RT FAZ-B8/3-RT 10 FAZ-B10/1-RT FAZ-B10/2-RT FAZ-B10/3-RT 13 FAZ-B13/1-RT FAZ-B13/2-RT FAZ-B13/3-RT 15 FAZ-B15/1-RT FAZ-B15/2-RT FAZ-B15/3-RT 16 FAZ-B16/1-RT FAZ-B16/2-RT FAZ-B16/3-RT 20 FAZ-B20/1-RT FAZ-B20/2-RT FAZ-B20/3-RT 25 FAZ-B25/1-RT FAZ-B25/2-RT FAZ-B25/3-RT 30 FAZ-B30/1-RT FAZ-B30/2-RT FAZ-B30/3-RT 32 FAZ-B32/1-RT FAZ-B32/2-RT FAZ-B32/3-RT 35 2 FAZ-B35/1-RT FAZ-B35/2-RT FAZ-B35/3-RT 40 2 FAZ-B40/1-RT FAZ-B40/2-RT FAZ-B40/3-RT FAZ-B1/3-RT 1 1 1 1 1 1 1 1 1 1 1 1 Notes 1 Two-piece order. Quantities of two per box. 2 240 Vac rated only. Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1 Three-Pole B Curve with Ring-Tongue Terminals (3-5X In Current Rating) FAZ-B1/3-NA 13 FAZ-RT UL 489 Circuit Breakers with Ring-Tongue Terminals--10 kAIC, 14 kAIC B Curve (15-25A) 1 V4-T1-51 1.2 1 1 FAZ-NA C Curve UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as branch circuit breakers Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947-2 Current limiting device UL file number E235139 1.45 UL 489 DIN Rail Miniature Circuit Breakers 1.13 1 Miniature Circuit Breakers and Supplementary Protectors 7200 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1200 300 120 60 30 1 t [sec] 10 1 5 2 1 1 0.5 0.2 1 2 0.1 1 0.05 1 0.02 0.005 0.002 0.001 1 0.0005 1 1 Single-Pole FAZ-NA UL 489 Circuit Breakers--10 kAIC, 14 kAIC C Curve (15-25A) Single-Pole 1 1 Catalog Amperes Number 1 Two-Pole Three-Pole Catalog Number Catalog Number Single-Pole 3 4 5 6 7 8 9 10 15 20 30 40 50 FAZ-C0.5/1-NA-SP FAZ-C0.5/2-NA FAZ-C0.5/3-NA 1 FAZ-C1/1-NA-SP 1.5 FAZ-C1.5/1-NA-SP FAZ-C1.5/2-NA FAZ-C1.5/3-NA 2 FAZ-C2/1-NA-SP FAZ-C2/2-NA FAZ-C2/3-NA 3 FAZ-C3/1-NA-SP FAZ-C3/2-NA FAZ-C3/3-NA 4 FAZ-C4/1-NA-SP FAZ-C4/2-NA FAZ-C4/3-NA 5 FAZ-C5/1-NA-SP FAZ-C5/2-NA FAZ-C5/3-NA 6 FAZ-C6/1-NA-SP FAZ-C6/2-NA FAZ-C6/3-NA 7 FAZ-C7/1-NA-SP FAZ-C7/2-NA FAZ-C7/3-NA 8 FAZ-C8/1-NA-SP FAZ-C8/2-NA FAZ-C8/3-NA 10 FAZ-C10/1-NA-SP FAZ-C10/2-NA FAZ-C10/3-NA 13 FAZ-C13/1-NA-SP FAZ-C13/2-NA FAZ-C13/3-NA 15 FAZ-C15/1-NA-SP FAZ-C15/2-NA FAZ-C15/3-NA 1 16 FAZ-C16/1-NA-SP FAZ-C16/2-NA FAZ-C16/3-NA 1 20 FAZ-C20/1-NA-SP FAZ-C20/2-NA FAZ-C20/3-NA 25 FAZ-C25/1-NA-SP FAZ-C25/2-NA FAZ-C25/3-NA 1 30 FAZ-C30/1-NA-SP FAZ-C30/2-NA FAZ-C30/3-NA 32 FAZ-C32/1-NA-SP FAZ-C32/2-NA FAZ-C32/3-NA 1 35 2 FAZ-C35/1-NA-SP FAZ-C35/2-NA FAZ-C35/3-NA 40 2 FAZ-C40/1-NA-SP FAZ-C40/2-NA FAZ-C40/3-NA 1 Two-Pole 1 1 1 Three-Pole 1 1 FAZ-C1/2-NA FAZ-RT UL 489 Circuit Breakers with Ring-Tongue Terminals--10 kAIC, 14 kAIC C Curve (15-25A) Single-Pole 1 Catalog Amperes Number C Curve (5-10X In Current Rating) 0.5 1 2 I / IN 1 1 C 0.01 1 1 Type C: 10 x I : t < 0.1 s N Specified tripping current IT = 1.45 x IN for t < 1 h 600 1 Type C: 5 x I : t > 0.1 s N Two-Pole Three-Pole Catalog Number Catalog Number C Curve with Ring-Tongue Terminals (5-10X In Current Rating) FAZ-C1/3-NA Two-Pole Three-Pole 1 0.5 FAZ-C0.5/1-RT-SP FAZ-C0.5/2-RT FAZ-C0.5/3-RT 1 FAZ-C1/1-RT-SP 1.5 FAZ-C1.5/1-RT-SP FAZ-C1.5/2-RT FAZ-C1.5/3-RT 2 FAZ-C2/1-RT-SP FAZ-C2/2-RT FAZ-C2/3-RT 3 FAZ-C3/1-RT-SP FAZ-C3/2-RT FAZ-C3/3-RT 4 FAZ-C4/1-RT-SP FAZ-C4/2-RT FAZ-C4/3-RT 5 FAZ-C5/1-RT-SP FAZ-C5/2-RT FAZ-C5/3-RT 6 FAZ-C6/1-RT-SP FAZ-C6/2-RT FAZ-C6/3-RT 7 FAZ-C7/1-RT-SP FAZ-C7/2-RT FAZ-C7/3-RT 8 FAZ-C8/1-RT-SP FAZ-C8/2-RT FAZ-C8/3-RT 10 FAZ-C10/1-RT-SP FAZ-C10/2-RT FAZ-C10/3-RT 13 FAZ-C13/1-RT-SP FAZ-C13/2-RT FAZ-C13/3-RT 15 FAZ-C15/1-RT-SP FAZ-C15/2-RT FAZ-C15/3-RT 16 FAZ-C16/1-RT-SP FAZ-C16/2-RT FAZ-C16/3-RT 20 FAZ-C20/1-RT-SP FAZ-C20/2-RT FAZ-C20/3-RT 25 FAZ-C25/1-RT-SP FAZ-C25/2-RT FAZ-C25/3-RT 30 FAZ-C30/1-RT-SP FAZ-C30/2-RT FAZ-C30/3-RT FAZ-C1/2-RT FAZ-C1/3-RT 32 FAZ-C32/1-RT-SP FAZ-C32/2-RT FAZ-C32/3-RT 35 2 FAZ-C35/1-RT-SP FAZ-C35/2-RT FAZ-C35/3-RT 40 2 FAZ-C40/1-RT-SP FAZ-C40/2-RT FAZ-C40/3-RT Notes 1 Option for single packaging on single-pole C and D curves only; add suffix SP when ordering. 2 240 Vac rated only. 1 V4-T1-52 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.2 Miniature Circuit Breakers and Supplementary Protectors 1 1.45 FAZ-NA D Curve UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as branch circuit breakers Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947-2 Current limiting device UL file number E235139 1.13 UL 489 DIN Rail Miniature Circuit Breakers 7200 2.55 I : N Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1200 Specified tripping current IT = 1.45 x IN for t < 1 h 600 300 1 t = 1-60 s (IN < 32A) t = 1-120 s (IN > 32A) Type D: 10 x I : t > 0.1 s N 1 Type D: 20 x I : t < 0.1 s N 1 120 1 60 30 1 t [sec] 10 5 1 2 1 1 1 0.5 0.2 1 3 0.1 2 0.05 D 1 0.02 0.01 0.005 1 0.002 0.001 1 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 30 40 50 1 I / IN Single-Pole Single-Pole FAZ-NA UL 489 Circuit Breakers--10 kAIC, 14 kAIC D Curve (13-20A) Single-Pole 1 Catalog Amperes Number Two-Pole Three-Pole Catalog Number Catalog Number Single-Pole Two-Pole Three-Pole FAZ-D0.5/1-NA-SP FAZ-D0.5/2-NA FAZ-D0.5/3-NA 1 FAZ-D1/1-NA-SP 1.5 FAZ-D1.5/1-NA-SP FAZ-D1.5/2-NA FAZ-D1.5/3-NA 2 FAZ-D2/1-NA-SP FAZ-D2/2-NA FAZ-D2/3-NA 3 FAZ-D3/1-NA-SP FAZ-D3/2-NA FAZ-D3/3-NA 4 FAZ-D4/1-NA-SP FAZ-D4/2-NA FAZ-D4/3-NA 5 FAZ-D5/1-NA-SP FAZ-D5/2-NA FAZ-D5/3-NA 6 FAZ-D6/1-NA-SP FAZ-D6/2-NA FAZ-D6/3-NA 7 FAZ-D7/1-NA-SP FAZ-D7/2-NA FAZ-D7/3-NA 8 FAZ-D8/1-NA-SP FAZ-D8/2-NA FAZ-D8/3-NA 10 FAZ-D10/1-NA-SP FAZ-D10/2-NA FAZ-D10/3-NA 13 FAZ-D13/1-NA-SP FAZ-D13/2-NA FAZ-D13/3-NA 15 FAZ-D15/1-NA-SP FAZ-D15/2-NA FAZ-D15/3-NA 16 FAZ-D16/1-NA-SP FAZ-D16/2-NA FAZ-D16/3-NA 20 FAZ-D20/1-NA-SP FAZ-D20/2-NA FAZ-D20/3-NA 25 FAZ-D25/1-NA-SP FAZ-D25/2-NA FAZ-D25/3-NA 30 FAZ-D30/1-NA-SP FAZ-D30/2-NA FAZ-D30/3-NA 32 FAZ-D32/1-NA-SP FAZ-D32/2-NA FAZ-D32/3-NA 35 2 FAZ-D35/1-NA-SP FAZ-D35/2-NA FAZ-D35/3-NA 2 FAZ-D40/1-NA-SP FAZ-D40/2-NA FAZ-D40/3-NA 40 FAZ-D1/2-NA FAZ-D1/3-NA 1 Catalog Amperes Number Two-Pole Three-Pole Catalog Number Catalog Number D Curve with Ring-Tongue Terminals (10-20X In Current Rating) D Curve (10-20X In Current Rating) 0.5 FAZ-RT UL 489 Circuit Breakers with Ring-Tongue Terminals--10 kAIC, 14 kAIC D Curve (13-20A) Two-Pole Three-Pole 0.5 FAZ-D0.5/1-RT-SP FAZ-D0.5/2-RT FAZ-D0.5/3-RT 1 FAZ-D1/1-RT-SP 1.5 FAZ-D1.5/1-RT-SP FAZ-D1.5/2-RT FAZ-D1.5/3-RT 2 FAZ-D2/1-RT-SP FAZ-D2/2-RT FAZ-D2/3-RT 3 FAZ-D3/1-RT-SP FAZ-D3/2-RT FAZ-D3/3-RT 4 FAZ-D4/1-RT-SP FAZ-D4/2-RT FAZ-D4/3-RT 5 FAZ-D5/1-RT-SP FAZ-D5/2-RT FAZ-D5/3-RT 6 FAZ-D6/1-RT-SP FAZ-D6/2-RT FAZ-D6/3-RT 7 FAZ-D7/1-RT-SP FAZ-D7/2-RT FAZ-D7/3-RT 8 FAZ-D8/1-RT-SP FAZ-D8/2-RT FAZ-D8/3-RT 10 FAZ-D10/1-RT-SP FAZ-D10/2-RT FAZ-D10/3-RT 13 FAZ-D13/1-RT-SP FAZ-D13/2-RT FAZ-D13/3-RT 15 FAZ-D15/1-RT-SP FAZ-D15/2-RT FAZ-D15/3-RT 16 FAZ-D16/1-RT-SP FAZ-D16/2-RT FAZ-D16/3-RT 20 FAZ-D20/1-RT-SP FAZ-D20/2-RT FAZ-D20/3-RT 25 FAZ-D25/1-RT-SP FAZ-D25/2-RT FAZ-D25/3-RT 30 FAZ-D30/1-RT-SP FAZ-D30/2-RT FAZ-D30/3-RT FAZ-D1/2-RT FAZ-D1/3-RT 32 FAZ-D32/1-RT-SP FAZ-D32/2-RT FAZ-D32/3-RT 35 2 FAZ-D35/1-RT-SP FAZ-D35/2-RT FAZ-D35/3-RT 40 2 FAZ-D40/1-RT-SP FAZ-C40/2-RT FAZ-D40/3-RT Notes 1 Option for single packaging on single-pole C and D curves only; add suffix SP when ordering. 2 240 Vac rated only. Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-53 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 1 1 1 1 UL 489 DIN Rail Miniature Circuit Breakers FAZ-NA-DC C Curve 1 1 Miniature Circuit Breakers and Supplementary Protectors UL approved (UL 489) and CSA Certified (CSA C22.2 No.5-02) as Branch Circuit Breakers Interrupting capacity: 10 kA at 125 Vdc UL/CSA, 10 kA at 250 Vdc 125 Vdc for one-pole, 250 Vdc for two-pole in series Current limiting device Polarity (+/-) sensitive and not for use on photovoltaic string application UL file number E235139 1 1 1 1 1 1 1 1 1 Single-Pole 1 FAZ-NA-DC UL 489 Circuit Breakers-- 10 kAIC at 125 Vdc Per Pole Single-Pole 1 Catalog Amperes Number 1 Two-Pole Catalog Number C Curve (5-10X In Current Rating) 1 2 FAZ-C2/1-NA-DC-SP FAZ-C2/2-NA-DC 3 FAZ-C3/1-NA-DC-SP FAZ-C3/2-NA-DC 4 FAZ-C4/1-NA-DC-SP FAZ-C4/2-NA-DC 1 5 FAZ-C5/1-NA-DC-SP FAZ-C5/2-NA-DC 1 6 FAZ-C6/1-NA-DC-SP FAZ-C6/2-NA-DC 7 FAZ-C7/1-NA-DC-SP FAZ-C7/2-NA-DC 1 8 FAZ-C8/1-NA-DC-SP FAZ-C8/2-NA-DC 10 FAZ-C10/1-NA-DC-SP FAZ-C10/2-NA-DC 1 13 FAZ-C13/1-NA-DC-SP FAZ-C13/2-NA-DC 15 FAZ-C15/1-NA-DC-SP FAZ-C15/2-NA-DC 1 16 FAZ-C16/1-NA-DC-SP FAZ-C16/2-NA-DC 1 20 FAZ-C20/1-NA-DC-SP FAZ-C20/2-NA-DC 25 FAZ-C25/1-NA-DC-SP FAZ-C25/2-NA-DC 1 30 FAZ-C30/1-NA-DC-SP FAZ-C30/2-NA-DC 32 FAZ-C32/1-NA-DC-SP FAZ-C32/2-NA-DC 1 35 FAZ-C35/1-NA-DC-SP FAZ-C35/2-NA-DC 40 FAZ-C40/1-NA-DC-SP FAZ-C40/2-NA-DC 1 Two-Pole 1 Note 1 Option for single packaging on single-pole C curves only; add suffix SP when ordering. 1 1 V4-T1-54 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1.2 Accessories Contact 1 FAZ-NA UL 489 Breakers FAZ-NA UL 489 Breakers, continued Description Catalog Number Description Two-pole contact or auxiliary contact/trip indicating contact Z-NHK 1 Busbar Catalog Number Busbar--single-pole, 6 terminals 2345 Z-SV/UL-16/1P-1TE/6 Busbar--single-pole, 12 terminals 2345 Z-SV/UL-16/1P-1TE/12 Busbar--single-pole, 18 terminals 2345 Z-SV/UL-16/1P-1TE/18 Busbar--two-pole, 6 terminals 2345 Z-SV/UL-16/2P-2TE/12 Busbar--two-pole, 18 terminals 2345 Z-SV/UL-16/2P-2TE/18 Busbar--three-pole, 6 terminals 2345 Z-SV/UL-16/3P-3TE/6 Busbar--two-pole, 12 terminals Auxiliary Contact Auxiliary contact Z-SV/UL-16/2P-2TE/6 2345 Busbar--three-pole, 12 terminals 2345 Z-SV/UL-16/3P-3TE/12 Z-IHK-NA Busbar--three-pole, 18 terminals 2345 Z-SV/UL-16/3P-3TE/18 Busbar Shroud Three-pole busbar shroud 1 1 1 1 1 1 1 1 ZV-BS-UL 1 1 Extension Terminal Shunt Trip Shunt trip 110-415 Vac FAZ-XAA-NA110-415VAC Shunt trip 12-110 Vac FAZ-XAA-NA12-110VAC Extension terminal-- 35 mm2 (2-14 AWG) 1 Z-EK/35/UL 1 1 1 Padlock Hasp Padlock hasp 1 IS/SPE-1TE Bus Connector Bus connector--conductors up to 50 mm2 (~1/0 AWG) 1 Z-EB/50/UL 1 Notes 1 Voltage of FAZ-NA circuit breaker is limited to 300V with this auxiliary contact installed. 2 Do not cut commoning link. 3 A maximum of three commoning links may be used in conjunction. Each breaker connected to the commoning link must have the same number of poles for proper use. 4 Not for use with ring-tongue circuit breakers. 5 Bus may be center fed for high current capacity. 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-55 1.2 1 1 1 1 1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Tripping Signal Switch Z-NHK, Z-IHK-NA Design according to IEC/EN 60947-5-1, IEC/EN 62019 Field installable The specified minimum voltages are per contact--take into account particularly in case of series connection Self-cleaning contacts Contact material and design particularly suitable for extra low voltage Z-NHK: the function of one of the two change-over contacts can be switched from "auxiliary switch" to "tripping signal switch" Tripping signal contact transmits message of electric tripping, not mechanical switch-off Test key for contact function "electrical tripping" Z-IHK-NA: will allow for > 480Y/277 Vac rating 1 Connection Diagram Z-IHK-NA Z-NHK 4.14/4.12 13 4.11 14 22 1.11 Same Polarity 1.14 1.12 Busbar Connection Example 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-56 21 4.12/4.14 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1.2 Technical Data and Specifications Trip Curve Chart Eaton FAZ-NA branch circuit breakers are available with "B," "C" and "D" tripping characteristics. B-curve devices are suitable for applications where low levels of inrush current are expected. C-curve devices are suitable for applications where medium levels of inrush current are expected. Applications include small transformers, lighting, pilot devices, control circuits and coils. C-curve devices provide a medium magnetic trip point. 1 Tripping Characteristics 1 D-curve devices are suitable for applications where high levels of inrush current are expected. The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies. 1 1 1 1 Eaton FAZ-NA devices are current limiting, which means they interrupt fault currents within one half cycle of the fault. Current limiting devices offer superior protection by reducing peak let-through current and energy. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-57 1.2 1 1 Connection Diagrams UL 489 DIN Rail Miniature Circuit Breakers Miniature Circuit Breakers FAZ-NA Technical Data Description Single-Pole Rated voltage FAZ-NA UL/CSA 1 1 1 Two-Pole Specification Electrical Design according to 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 489, CSA C22.2 No.5, IEC 60947-2 10 kAIC at 277/480V from 0.5A to 32A 14 kAIC at select amperages B and C Curves (15-25A), D Curve (13-20A) UL/CSA 10 kAIC at 240 Vac for 35A and 40A UL/CSA 10 kAIC at 48 Vdc per pole IEC 947-2 15 kAIC at 240/415 Vac Rated voltage FAZ-NA-DC UL/CSA 10 kAIC at 125 Vdc per pole (two poles maximum) 10 kAIC at 250 Vdc with two poles connected in series 1 Rated frequency 1 Characteristic B, C, D Endurance 20,000 operations 1 Line voltage connection Suitable for reverse feed 1 Frame size 45 mm Device height 105 mm Device width 17.7 mm per pole Terminal protection Finger and hand touch safe according to BGV A3, OVE-EN 6 1 50/60 Hz Mechanical Three-Pole 1 1 1 1 1 Mounting Quick fastening with two lock-in positions on IEC/EN 60715 Upper and lower terminals Open mouth/lift terminals Terminal capacity One wire: AWG 18-6 Two wires: AWG 18-10 Terminal fastening torque AWG 18-21: 21 lb-in AWG 10-8: 25 lb-in AWG 6: 36 lb-in Mounting Independent of position Calibration temperature UL 489, CSA C22.2 No.5 1 IEC 60947-2 40C 30C 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-58 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Power Loss at ln Characteristic B Characteristic C 1 Characteristic D Single-Pole Two-Pole Three-Pole Single-Pole Two-Pole Three-Pole Single-Pole Two-Pole Three-Pole In [A] P [W] P [W] P [W] P [W] P [W] P [W] P [W] P [W] P [W] 0.5 -- -- -- 1.6 3.2 4.7 1.6 3.2 4.8 1.0 1.1 2.2 3.4 1.1 2.2 3.4 0.8 1.5 2.3 1.5 2.2 4.4 6.6 1.3 2.6 3.9 1.0 2.1 3.1 2.0 1.4 2.8 4.3 1.4 2.8 4.3 1.0 2.1 3.1 3.0 2.1 4.2 6.4 1.2 2.4 3.6 1.2 2.4 3.6 4.0 1.4 2.9 4.3 1.4 2.9 4.3 1.4 2.9 4.3 5.0 1.8 3.7 5.5 1.9 3.7 5.6 1.5 2.9 4.4 6.0 1.7 3.5 5.2 1.2 2.3 3.5 1.2 2.3 3.5 7.0 2.0 4.0 6.0 1.4 2.8 4.3 1.4 2.8 4.3 8.0 2.0 3.9 5.9 1.4 2.8 4.2 1.2 2.4 3.7 10.0 1.8 3.6 5.3 1.8 3.6 5.3 1.5 3.0 4.5 13.0 2.4 4.7 7.1 2.4 4.7 7.1 2.0 4.1 6.1 15.0 1.9 3.8 5.6 1.9 3.8 5.6 1.5 3.1 4.6 16.0 2.1 4.3 6.4 2.1 4.3 6.4 1.7 3.5 5.2 20.0 2.9 5.8 8.7 2.9 5.8 8.7 1.8 3.7 5.5 25.0 3.1 6.2 9.3 3.1 6.2 9.3 2.6 5.1 7.7 30.0 3.0 6.0 9.0 3.0 6.0 9.0 2.7 5.4 8.1 32.0 3.4 6.8 10.2 3.4 6.8 10.2 3.1 6.2 9.3 35.0 4.0 8.1 12.1 3.7 7.4 11.0 3.8 7.6 11.3 40.0 4.0 8.1 12.1 4.0 8.1 12.1 3.9 7.8 11.6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-59 1.2 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Let-Through Energy Characteristic B (1-32A), 277V Characteristic B (35-40A), 240V Characteristic C (0.5-32A), 277V Characteristic C (40A), 240V 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-60 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Characteristic D (0.5-32A), 277V 1.2 Characteristic D (40A), 240V 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-61 1.2 1 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Influence of Ambient Temperature T on Load Carrying Capacity Device Market Current Rating In (A) at 40C 15C 20C 25C 30C 40C 50C 55C 60C 1 0.5 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.1 1.1 1.1 1.0 1.0 1.0 0.9 0.9 1 1.5 1.7 1.6 1.6 1.6 1.5 1.4 1.4 1.4 1 2.0 2.2 2.2 2.1 2.1 2.0 1.9 1.9 1.8 3.0 3.3 3.2 3.2 3.1 3.0 2.9 2.9 2.8 1 4.0 4.4 4.3 4.2 4.2 4.0 3.8 3.8 3.7 5.0 5.5 5.4 5.3 5.2 5.0 4.8 4.7 4.6 1 6.0 6.6 6.5 6.4 6.2 6.0 5.8 5.6 5.5 7.0 7.7 7.6 7.4 7.3 7.0 6.7 6.6 6.4 8.0 8.8 8.6 8.5 8.3 8.0 7.7 7.5 7.4 1 10.0 11.0 10.8 10.6 10.4 10.0 9.6 9.4 9.2 13.0 14.3 14.0 13.8 13.5 13.0 12.5 12.5 12.0 1 15.0 16.5 16.2 15.9 15.6 15.0 14.4 14.1 13.8 16.0 17.6 17.3 17.0 16.6 16.0 15.4 15.0 14.7 1 20.0 22.0 21.6 21.2 20.8 20.0 19.2 18.8 18.4 1 25.0 27.5 27.0 26.5 26.0 25.0 24.0 23.3 23.0 30.0 33.0 32.4 31.8 31.2 30.0 28.8 28.2 27.6 32.0 35.2 34.6 33.9 33.3 32.0 30.7 30.1 29.4 40.0 44.0 43.2 42.4 41.6 40.0 38.4 37.6 36.8 1 1 1 In (A) at Higher Ambient Temperature 1 Load Carrying Capacity of Adjoining Miniature Circuit Breakers 1 1.00 1 1 1 Load Factor KT [I/IN] 1 Rated Diversity Factor 1 1 0.90 0.80 0.70 1 1 2 3 4 5 6 Number of Circuit Breakers 1 1 Ambient Temperature T [C] Maximum Load IL at ambient temperature T: IL (T) = IN KT(T) 1 1 1 1 1 1 V4-T1-62 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 7 8 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Z-NHK 1.2 Contact and Auxiliary Contact Description Z-NHK Z-IHK-NA 2CO 1NO + 1NC 1 1 Electrical Contact function Z-IHK-NA Rated voltage 230V 250V Frequency 50/60 Hz 50/60 Hz Rated current 2A 6A 1 1 Rated thermal current Ith 2A 6A Utilization category AC13 Rated operational current Ie 1 3A/250 Vac 3A/250 Vac Utilization category AC15 Rated operational current Ie 1 2A/250 Vac 2A/250 Vac Utilization category DC12 Rated operational current Ie 1 0.5A/110 Vdc 0.5A/110 Vdc 0.25A/220 Vdc 1 Rated insulation voltage UI 250 Vac 250 Vac Minimum operational voltage per contact Umin 5 Vdc 5 Vdc 1 Minimum operational current Imin 10 mA DC 10 mA AC/DC Rated peak withstand voltage Uimp (1.2/50) 2.5 kV 4 kV Conditional short-circuit current Ik with backup fuse 6A 1 kA 1 kA Max. backup fuse, overload and short circuit 6A gL -- 1 1 1 Mechanical Tripping indicator "electrical tripping" Blue/white -- Frame size 45 mm 45 mm Device height 80 mm 80 mm Device width 8.8 mm (0.5MU) 8.8 mm (0.5MU) Mounting Onto switching device -- 1 1 1 1 Degree of protection, built-in IP40 IP40 Terminal protection Finger and hand touch safe According to BGV A3, OVE-EN 6 Finger and hand touch safe According to BGV A3, OVE-EN 6 1 Terminals Lift terminals Lift terminals Terminal capacity 20-14 AWG 0.5-2.5 mm2 1 Terminal screws M3 (Posidrive Z0) M3 (Posidrive Z0) Fastening torque of terminal screws 7 lb-in Max. 1.2 Nm 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-63 1.2 1 1 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Shunt trip release FAZ-XAA-NA Remote release for subsequent mounting onto FAZ-NA/RT Additional installation of standard auxiliary switch is possible Position indicator red-green Connection Diagram 1 Shunt Trip Release FAZ-XAA-NA Description FAZ-XAA-NA12-110VAC FAZ-XAA-NA110-415VAC Can be mounted onto FAZ-NA / FAZ-NA-DC / FAZ-RT FAZ-NA / FAZ-NA-DC / FAZ-RT Operational voltage range 12-110 Vac 12-60 Vdc 110-415 Vac 110-230 Vdc Frequency 50/60 Hz 50/60 Hz Electrical 1 1 2 1 1 Mechanical Frame size 45 mm 45 mm 1 Device height 105 mm 105 mm Device width 17.5 mm 17.5 mm 1 Mounting Quick fastening with two lock-in positions on EN 50022 1 Terminal protection Degree of protection, built-in IP40 1 1 1 1 1 1 1 Connection Diagrams Three-Pole Busbar Open mouthed/lift Open mouthed/lift Terminal capacity One and two wires 18-10 AWG 18-10 AWG Busbar Block UL 489 (Pin) Description UL 489 IEC/EN 60947-2 Rated operational voltage 480/277 Vac 96 Vdc -- Rated frequency 50/60 Hz -- Rated voltage 480 Vac 690 Vac Electrical 1 Two-Pole Busbar 1 1 1 Terminals Busbar block UL 489 (pin) Tested according to UL 489 Do not cut Extension terminal 35 mm2 Z-EK/35/UL for copper conductors Incoming terminal 50 mm2 Z-EB/50/UL For covering of not used pins, use busbar tag shrouds ZV-BS-UL 1 1 IP40 Finger and hand touch safe according to BGV A3, OVE-EN 6 Single-Pole Busbar 1 1 Overvoltage category -- III Rated impulse withstand voltage Uimp -- 9.5 kV Rated current 80A at 40C 80A at 30C Rated conditional short-circuit current AC with 350A gG -- 15 kA Short-circuit current 10 kA -- Mechanical Busbar cross section -- 16 mm2 Cu Flame class according to UL 94 V0 -- Pollution degree -- 2 1 Comparative tracking index -- CTI 600 Minimum clearance (internal/external) -- > 9.5/25.4 mm 1 Minimum creepage distance (internal/external) -- > 12.7/50.8 mm Resistance to climatic conditions -- According to DIN/EN 60068 1 1 V4-T1-64 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Application Guidelines 1 Example of UL 489 and UL 1077 Application 1 1 UL 489 Breaker 1 1 1 UL 489 Branch UL 1077 Internal Receptacle 1 External Receptacle 1 1 Electronics 1 UL 489 Branch UL 1077 Other Sensitive Devices External Motor 1 M 1 UL 489 Branch 1 UL 489 Branch UL 1077 HACR External Motor 1 M 1 1 Motor Controller 1 1 1 Example of UL 489 and UL 1077 Application 1 UL 489 circuit breakers 1 Used for branch circuit protection, internal/external receptacles, external motors and HACR equipment (heating, air conditioning and refrigeration). 1 UL 1077 supplementary protectors 1 Used for overcurrent protection within appliances or electrical equipment, where branch circuit protection is already provided or not required. 1 Note: UL 4 89 devices can be used in place of UL 1077; UL 1077 devices cannot be used in place of UL 489. 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-65 1.2 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Dimensions Approximate Dimensions in Inches (mm) Lockout Attachment--IS/SPE-ITE Miniature Circuit Breakers 1 Single-Pole Two-Pole Three-Pole 1 1 1 4.13 (105.0) 1 4.13 (105.0) 1 1 .70 .70 (17.7) (17.7) 2.09 (53.1) .70 (17.7) 1.39 (35.3) .70 (17.7) 1 4.13 (105.0) Accessories 1 Z-SV/UL-16/6 ZV-BS-UL Z-SV/UL-18...12 1 1 1 1 1 1 Z-EK/35/UL Z-SV/UL-16.../18 1 1 1 1 1 1 Z-EK/35/UL Z-EB/50/UL 1 Description UL 489 1 Ue f IEC/EN 60947-2 Description UL 489 IEC/EN 60947-2 480 Vac/96 Vdc 240/415 Vac Ue 480 Vac/96 Vdc 240/415 Vac 50/60 Hz 50/60 Hz f 50/60 Hz 50/60 Hz Uimp -- 9.5 kV Uimp -- 9.5 kV Ie 80A at 40C 80A at 30C Ie 115A at 40C 160A at 30C 1 #2-14 AWG 60/75C Cu 2.5-35 mm2 Cu #1-14 AWG 60/75C Cu 1.5-50 mm2 Cu 1 0.56 in 14 mm 0.56 in 14 mm 1 1 1 V4-T1-66 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1.2 Contents WMZ Circuit Breakers Description FAZ-NA Circuit Breakers . . . . . . . . . . . . . . . . . . . . WMZ Circuit Breaker Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V4-T1-49 V4-T1-68 V4-T1-69 V4-T1-70 V4-T1-72 V4-T1-73 V4-T1-80 1 1 1 1 1 1 1 1 Optimum and Efficient Protection for Every Application 1 1 1 WMZ Circuit Breaker Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eaton's WMZ DIN rail mountable circuit breaker is designed for use in branch service applications. Application Description Feeder and branch circuit protection for: Convenience receptacle circuits (internal/external) Motor control circuits Load circuits leaving the equipment (external) HACR internal/external equipment (heating, air conditioning, refrigeration) PLC I/O points Computers Power supplies Control instrumentation Relays UPS Power conditioners Complete range of UL 489 listed DIN rail mounted miniature circuit breakers up to 40A current rating Standard ratings of 10 kAIC at 277/480 Vac Select amperages available at 14 kAIC at 277/480 Vac and 10 kAIC at125 Vdc Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit Suitable for branch circuit device protection Thermal-magnetic overcurrent protection Two levels of shortcircuit protection, categorized by C and D curves Trip-free design--breaker can not be defeated by holding the handle in the ON position Captive screws cannot be lost SWD (switching duty)-- suitable for switching fluorescent lighting loads (In d 20A) 1 For use in applications for which UL 1077 or CSA C22.2 No.235 are also allowed Field-installable shunt trip and auxiliary switch subsequent mounting Separate version for ringtongue connection (Type WMZT....T), terminal screws can be removed (on both sides) Module width of only 17.7 mm (per pole) Contact Position Indicator (red/green) Easy installation on DIN rail Possibility for sealing the toggle in ON or OFF position 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-67 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Standards and Certifications 1 1 Device Printing on Front and Side Installation options 1 These branch circuit breakers are available in two terminal configurations: standard box terminals that accept multiple conductors and ring-tongue terminals, ideally suited to demanding requirements of the semi-conductor industry. 1 1 1 All breakers mount on standard 35 mm DIN rail. Bus connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies. These circuit breakers can also be reverse feed. 1 1 1 1 1 UL 489 Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection Products meet the requirements of the National Electrical Code(R) (NEC) Powerful Offering for Machine and System Builders The WMZ is available with C and D characteristics in accordance with UL 489, CSA C22.2 No.5; UL 1077, CSA C22.2 No.235 and IEC 60947-2. Conductor Type 1 Breaker Status Indicator 1 Calibration Temperature UL/CSA 1 Rated Current 1 1 1 Rated Voltage UL/CSA Catalog Number 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-68 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com CSA C22.2 No.5 Standard for molded case circuit breakers for feeder and branch circuit protection (corresponds closely to UL 489 Standard) Products meet the requirements of the Canadian Electrical Code (CEC) These devices are RoHS compliant 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Catalog Number Selection 1 WMZ T 1 C 16 T 1 Breaker Family WMZ = WMZ UL circuit breaker 1 Terminal Breaker Type T =10 kAIC H =14 kAIC D =10 kAIC/DC 12 Ampere Rating Number of Poles 1 = Single-pole 2 = Two-pole 3 = Three-pole 3 Protective Curve C = C Curve (5-10X In) D = D Curve (10-20X In) 3 X0 = 0.5A 01 = 1A X1 = 1.5A 02 = 2A 03 = 3A 04 = 4A 05 = 5A 06 = 6A 07 = 7A 08 = 8A 10 = 10A 13 = 13A 15 = 15A 16 = 16A 20 = 20A 25 = 25A 30 = 30A 32 = 32A 40 = 40A T = Ring terminals [blank] = Standard box terminals 1 1 1 1 1 Notes 1 Limited curve and ampere offerings. 2 125 Vdc for single-pole, 250 Vdc for two-pole in series. 3 Not offered for Type WMZD. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-69 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1 Product Selection 1 WMZT 1 Single-Pole 1 WMZT UL 489 Circuit Breakers--10 kAIC Amperes Single-Pole Two-Pole Three-Pole Catalog Number Catalog Number Catalog Number 1 0.5 WMZT1CX0 WMZT2CX0 WMZT3CX0 1 1 WMZT1C01 WMZT2C01 WMZT3C01 1.5 WMZT1CX1 WMZT2CX1 WMZT3CX1 2 WMZT1C02 WMZT2C02 WMZT3C02 3 WMZT1C03 WMZT2C03 WMZT3C03 4 WMZT1C04 WMZT2C00 WMZT3C04 5 WMZT1C05 WMZT2C05 WMZT3C05 6 WMZT1C06 WMZT2C06 WMZT3C06 7 WMZT1C07 WMZT2C07 WMZT3C07 8 WMZT1C08 WMZT2C08 WMZT3C08 10 WMZT1C10 WMZT2C10 WMZT3C10 1 13 WMZT1C13 WMZT2C13 WMZT3C13 15 WMZT1C15 WMZT2C15 WMZT3C15 1 16 WMZT1C16 WMZT2C16 WMZT3C16 20 WMZT1C20 WMZT2C20 WMZT3C20 25 WMZT1C25 WMZT2C25 WMZT3C25 1 30 WMZT1C30 WMZT2C30 WMZT3C30 32 WMZT1C32 WMZT2C32 WMZT3C32 1 40 WMZT1C40 WMZT2C40 WMZT3C40 1 1 1 1 1 Three-Pole 1 1 1 Single-Pole Two-Pole Three-Pole Catalog Number Catalog Number Catalog Number C Curve with Ring-Tongue Terminals (5-10X In Current Rating) Two-Pole Three-Pole D Curve (10-20X In Current Rating) 1 WMZT UL 489 Circuit Breakers with Ring-Tongue Terminals--10 kAIC Amperes C Curve (5-10X In Current Rating) Two-Pole Single-Pole 0.5 WMZT1CX0T WMZT2CX0T WMZT3CX0T 1 WMZT1C01T WMZT2C01T WMZT3C01T 1.5 WMZT1CX1T WMZT2CX1T WMZT3CX1T 2 WMZT1C02T WMZT2C02T WMZT3C02T 3 WMZT1C03T WMZT2C03T WMZT3C03T 4 WMZT1C04T WMZT2C04T WMZT3C04T 5 WMZT1C05T WMZT2C05T WMZT3C05T 6 WMZT1C06T WMZT2C06T WMZT3C06T 7 WMZT1C07T WMZT2C07T WMZT3C07T 8 WMZT1C08T WMZT2C08T WMZT3C08T 10 WMZT1C10T WMZT2C10T WMZT3C10T 13 WMZT1C13T WMZT2C13T WMZT3C13T 15 WMZT1C15T WMZT2C15T WMZT3C15T 16 WMZT1C16T WMZT2C16T WMZT3C16T 20 WMZT1C20T WMZT2C20T WMZT3C20T 25 WMZT1C25T WMZT2C25T WMZT3C25T 30 WMZT1C30T WMZT2C30T WMZT3C30T 32 WMZT1C32T WMZT2C32T WMZT3C32T 40 WMZT1C40T WMZT2C40T WMZT3C40T 0.5 WMZT1DX0 WMZT2DX0 1 WMZT1D01 WMZT2D01 WMZT3D01 D Curve with Ring-Tongue Terminals (10-20X In Current Rating) 1.5 WMZT1DX1 WMZT2DX1 WMZT3DX1 0.5 WMZT1DX0T WMZT2DX0T WMZT3D02 1 WMZT1D01T WMZT2D01T WMZT3D01T WMZT1DX1T WMZT2DX1T WMZT3DX1T 2 WMZT1D02 WMZT2D02 WMZT3DX0 WMZT3DX0T 3 WMZT1D03 WMZT2D03 WMZT3D03 1.5 1 4 WMZT1D04 WMZT2D04 WMZT3D04 2 WMZT1D02T WMZT2D02T WMZT3D02T WMZT1D05 WMZT2D05 WMZT3D05 WMZT1D03T WMZT2D03T WMZT3D03T 1 5 3 6 WMZT1D06 WMZT2D06 WMZT3D06 4 WMZT1D04T WMZT2D04T WMZT3D04T 7 WMZT1D07 WMZT2D07 WMZT3D07 5 WMZT1D05T WMZT2D05T WMZT3D05T WMZT3D08 6 WMZT1D06T WMZT2D06T WMZT3D06T WMZT3D10 7 WMZT1D07T WMZT2D07T WMZT3D07T WMZT1D08T WMZT2D08T WMZT3D08T 1 8 WMZT1D08 WMZT2D08 1 10 1 13 WMZT1D13 WMZT2D13 WMZT3D13 8 15 WMZT1D15 WMZT2D15 WMZT3D15 10 WMZT1D10T WMZT2D10T WMZT3D10T 16 WMZT1D16 WMZT2D16 WMZT3D16 13 WMZT1D13T WMZT2D13T WMZT3D13T WMZT3D20 15 WMZT1D15T WMZT2D15T WMZT3D15T WMZT3D25 16 WMZT1D16T WMZT2D16T WMZT3D16T WMZT1D20T WMZT2D20T WMZT3D20T 1 20 1 25 1 1 1 WMZT1D10 WMZT1D20 WMZT1D25 WMZT2D10 WMZT2D20 WMZT2D25 30 WMZT1D30 WMZT2D30 WMZT3D30 20 32 WMZT1D32 WMZT2D32 WMZT3D32 25 WMZT1D25T WMZT2D25T WMZT3D25T 40 WMZT1D40 WMZT2D40 WMZT3D40 30 WMZT1D30T WMZT2D30T WMZT3D30T 32 WMZT1D32T WMZT2D32T WMZT3D32T 40 WMZT1D40T WMZT2D40T WMZT3D40T Notes Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947. Optional connections for ring-tongue terminals. 1 V4-T1-70 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers WMZH Single-Pole WMZD WMZH UL 489 Circuit Breakers -- 14 kAIC Single-Pole Amperes Catalog Number Two-Pole Catalog Number Single-Pole Three-Pole 1 WMZD UL 489 Circuit Breakers--10 kAIC at 125 Vdc Per Pole Catalog Number Amperes C Curve (5-10X In Current Rating) Two-Pole 1.2 15 WMZH1C15 WMZH2C15 WMZH3C15 16 WMZH1C16 WMZH2C16 WMZH3C16 20 WMZH1C20 WMZH2C20 WMZH3C20 25 WMZH1C25 WMZH2C25 WMZH3C25 D Curve (10-20X In Current Rating) 13 WMZH1D13 WMZH2D13 WMZH3D13 15 WMZH1D15 WMZH2D15 WMZH3D15 16 WMZH1D16 WMZH2D16 WMZH3D16 20 WMZH1D20 WMZH2D20 WMZH3D20 Three-Pole Single-Pole Two-Pole Catalog Number Catalog Number C Curve (5-10X In Current Rating) Two-Pole 2 WMZD1C02 WMZD2C02 3 WMZD1C03 WMZD2C03 4 WMZD1C04 WMZD2C04 5 WMZD1C05 WMZD2C05 6 WMZD1C06 WMZD2C06 7 WMZD1C07 WMZD2C07 8 WMZD1C08 WMZD2C08 10 WMZD1C10 WMZD2C10 13 WMZD1C13 WMZD2C13 15 WMZD1C15 WMZD2C15 16 WMZD1C16 WMZD2C16 20 WMZD1C20 WMZD2C20 25 WMZD1C25 WMZD2C25 30 WMZD1C30 WMZD2C30 32 WMZD1C32 WMZD2C32 40 WMZD1C40 WMZD2C40 Notes Interrupting capacity: 10 kA UL/CSA; 15 kA IEC 60947. Optional connections for ring-tongue terminals. Single-Pole Amperes Two-Pole Three-Pole Catalog Number Catalog Number Catalog Number Two-Pole WMZH1C15T WMZH2C15T WMZH3C15T 16 WMZH1C16T WMZH2C16T WMZH3C16T 20 WMZH1C20T WMZH2C20T WMZH3C20T 25 WMZH1C25T WMZH2C25T WMZH3C25T WMZH1D13T WMZH2D13T WMZH3D13T 15 WMZH1D15T WMZH2D15T WMZH3D15T 16 WMZH1D16T WMZH2D16T WMZH3D16T 20 WMZH1D20T WMZH2D20T WMZH3D20T 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 D Curve (10-20X In Current Rating) 13 1 1 C Curve (5-10X In Current Rating) 15 1 1 WMZH UL 489 Circuit Breakers with RingTongue Terminals Single-Pole 1 1 1 1 Three-Pole 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-71 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1 Accessories 1 WMZ UL 489 Breakers Description Catalog Number Two-pole contact or auxiliary contact/trip indicating contact WMZSAUXTRIP 1 Auxiliary contact WMZTAUX Shunt trip 110-415 Vac WMZTST415 1 Shunt trip 12-110 Vac WMZTST110 Padlock hasp WMZPLK 1 Busbar--single-pole, 6 terminals WMZT1P6T 1 Busbar--single-pole, 12 terminals WMZT1P12T Busbar--single-pole, 18 terminals WMZT1P18T 1 Busbar--two-pole, 6 terminals WMZT2P6T Busbar--two-pole, 12 terminals WMZT2P12T 1 Busbar--two-pole, 18 terminals WMZT2P18T 1 Busbar--three-pole, 6 terminals WMZT3P6T Busbar--three-pole, 12 terminals WMZT3P12T Busbar--three-pole, 18 terminals WMZT3P18T Three-pole busbar shroud WMZT3PSHROUD Extension terminal--35 mm2 (2-14 AWG) WMZT35EXT Bus connector--conductors up to 50 mm2 (~1/0 AWG) WMZTBCON 1 1 1 Tripping Signal Switch WMZSAUXTRIP, WMZTAUX Design according to IEC/EN 60947-5-1, IEC/EN 62019 and UL Field installable The specified minimum voltages are per contact--take into account particularly in case of series connection Self-cleaning contacts Contact material and design particularly suitable for extra low voltage WMZSAUXTRIP: the function of one of the two change-over contacts can be switched from "auxiliary switch" to "tripping signal switch" Attention: The voltage of the WMZT...circuit breaker is limited to 300V with this auxiliary installed. Tripping signal contact transmits message of electric tripping, not mechanical switch-off Test key for contact function "electrical tripping" WMZTAUX: will allow for > 480Y/277 Vac rating Connection Diagram WMZTAUX WMZSAUXTRIP 4.14/4.12 1 21 4.12/4.14 1 13 4.11 1 1 14 1 22 1.11 Same Polarity 1.14 1 1.12 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-72 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Technical Data and Specifications Trip Curve Chart Eaton WMZ branch circuit breakers are available with "C" and "D" tripping characteristics. C-curve devices are suitable for application where medium levels of inrush current are expected. Applications include small transformers, lighting, pilot devices, control circuits and coils. C-curve devices provide a medium magnetic trip point. 1 Tripping Characteristics D-curve devices are suitable for applications where high levels of inrush current are expected. The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies. Eaton WMZ devices are current limiting, which means they interrupt fault currents within one-half cycle of the fault. Current limiting devices offer superior protection by reducing peak let-through current and energy. 1 Tripping characteristic acc. to UL 489 Conventional non-tripping current Int = 1.0 IN (T=40) Conventional tripping current It = 1.35 IN: t < 1 h (T=25) 2.0 IN: t = 12 - 120 s (T=25) Instantaneous tripping acc. to IEC 60898-1 type C: 5 IN: t > 0.1 s 10 IN: t < 0.1 s type D: 10 IN: t > 0.1 s 20 IN: t < 0.1 s 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-73 1.2 1 1 Connection Diagrams 1 1 Miniature Circuit Breakers WMZ Technical Data Two-Pole 1 1 1 1 Three-Pole 1 Specification Electrical Design according to UL 489, CSA C22.2 No.5, IEC 60947-2 Rated voltage WMZT UL/CSA UL/CSA UL/CSA IEC 947-2 10 kAIC at 277/480V from 0.5A to 32A 10 kAIC at 240 Vac for 40A 10 kAIC at 48 Vdc per pole 15 kAIC at 240/415 Vac Rated voltage WMZD UL/CSA 1 1 UL 489 DIN Rail Miniature Circuit Breakers Description Single-Pole 1 1 Miniature Circuit Breakers and Supplementary Protectors 10 kAIC at 125 Vdc per pole (two poles max.) 10 kAIC at 250 Vdc with two poles connected in series Rated voltage WMZH UL/CSA IEC 947-2 14 kAIC at 277/480V at listed amperages 15 kAIC at 240/415 Vac Rated frequency 50/60 Hz Rated breaking capacity WMZT UL/CSA IEC 947-2 10 kA 15 kA Rated breaking capacity WMZH UL/CSA IEC 947-2 14 kA 15 kA Characteristic C, D Endurance 20,000 operations Line voltage connection Suitable for reverse feed Mechanical 1 1 1 1 1 Frame size 45 mm Device height 105 mm Device width 17.7 mm per pole Mounting Quick fastening with two lock-in positions on IEC/EN 60715 Upper and lower terminals Open mouth/lift terminals Terminal capacity One wire AWG 18-6 Two wires AWG 8-10 Terminal fastening torque AWG 18-21: 21 lb-in AWG 10-8: 25 lb-in 1 AWG 6: 36 lb-in 1 1 Mounting Independent of position Calibration temperature UL 489, CSA C22.2 No.5 IEC 60947-2 40C 30C 1 1 1 1 1 1 1 1 1 V4-T1-74 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1.2 Power Loss at ln Characteristic C 1 Characteristic D Single-Pole Two-Pole Three-Pole Single-Pole Two-Pole Three-Pole In [A] P [W] P [W] P [W] P [W] P [W] P [W] 0.5 1.6 3.2 4.7 1.6 3.2 4.8 1.0 1.1 2.2 3.4 0.8 1.5 2.3 1.5 1.3 2.6 3.9 1.0 2.1 3.1 2.0 1.4 2.8 4.3 1.0 2.1 3.1 3.0 1.2 2.4 3.6 1.2 2.4 3.6 4.0 1.4 2.9 4.3 1.4 2.9 4.3 5.0 1.9 3.7 5.6 1.5 2.9 4.4 6.0 1.2 2.3 3.5 1.2 2.3 3.5 7.0 1.4 2.8 4.3 1.4 2.8 4.3 8.0 1.4 2.8 4.2 1.2 2.4 3.7 10.0 1.8 3.6 5.3 1.5 3.0 4.5 13.0 2.4 4.7 7.1 2.0 4.1 6.1 15.0 1.9 3.8 5.6 1.5 3.1 4.6 16.0 2.1 4.3 6.4 1.7 3.5 5.2 20.0 2.9 5.8 8.7 1.8 3.7 5.5 25.0 3.1 6.2 9.3 2.6 5.1 7.7 30.0 3.0 6.0 9.0 2.7 5.4 8.1 32.0 3.4 6.8 10.2 3.1 6.2 9.3 35.0 3.7 7.4 11.0 3.8 7.6 11.3 40.0 4.0 8.1 12.1 3.9 7.8 11.6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-75 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1 Let-Through Energy 1 Characteristic C (0.5-32A), 277V Characteristic C (40A), 240V Characteristic D (0.5-32A), 277V Characteristic D (40A), 240V 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-76 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.2 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Influence of Ambient Temperature T on Load Carrying Capacity 1 Device Market Current Rating In (A) at 40C In (A) at Higher Ambient Temperature 15C 20C 25C 30C 40C 50C 55C 60C 0.5 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.1 1.1 1.1 1.0 1.0 1.0 0.9 0.9 1.5 1.7 1.6 1.6 1.6 1.5 1.4 1.4 1.4 2.0 2.2 2.2 2.1 2.1 2.0 1.9 1.9 1.8 3.0 3.3 3.2 3.2 3.1 3.0 2.9 2.9 2.8 4.0 4.4 4.3 4.2 4.2 4.0 3.8 3.8 3.7 5.0 5.5 5.4 5.3 5.2 5.0 4.8 4.7 4.6 6.0 6.6 6.5 6.4 6.2 6.0 5.8 5.6 5.5 7.0 7.7 7.6 7.4 7.3 7.0 6.7 6.6 6.4 8.0 8.8 8.6 8.5 8.3 8.0 7.7 7.5 7.4 10.0 11.0 10.8 10.6 10.4 10.0 9.6 9.4 9.2 13.0 14.3 14.0 13.8 13.5 13.0 12.5 12.5 12.0 15.0 16.5 16.2 15.9 15.6 15.0 14.4 14.1 13.8 16.0 17.6 17.3 17.0 16.6 16.0 15.4 15.0 14.7 20.0 22.0 21.6 21.2 20.8 20.0 19.2 18.8 18.4 25.0 27.5 27.0 26.5 26.0 25.0 24.0 23.3 23.0 30.0 33.0 32.4 31.8 31.2 30.0 28.8 28.2 27.6 32.0 35.2 34.6 33.9 33.3 32.0 30.7 30.1 29.4 40.0 44.0 43.2 42.4 41.6 40.0 38.4 37.6 36.8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-77 1.2 1 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers WMZ UL 489 Auxiliary and Trip Indicating Contacts Description WMZSAUXTRIP WMZTAUX 1NO + 1NC 1 Electrical 1 Contact function 2CO Rated voltage 230V 250V Frequency 50/60 Hz 50/60 Hz Rated current 2A 6A 1 1 Rated thermal current Ith 2A 6A Utilization category AC13 rated operational current Ie 3A/250 Vac 3A/250 Vac Utilization category AC15 rated operational current Ie 2A/250 Vac 2A/250 Vac 1 Utilization category DC12 rated operational current Ie 0.5A/110 Vdc 0.5A/110 Vdc 1 Rated insulation voltage UI 250 Vac 1 Minimum operational voltage per contact Umin 5 Vdc 5 Vdc Minimum operational current Imin 10 mA DC 10 mA AC/DC 1 1 1 0.25A/220 Vdc 250 Vac Rated peak withstand voltage Uimp (1.2/50) 2.5 kV 4 kV Conditional short-circuit current Ik with back-up fuse 6A 1 kA 1 kA Max. back-up fuse, overload and short circuit 6A gL -- Mechanical 1 Tripping indicator "electrical tripping" Blue/white -- 1 Frame size 45.0 mm 45.0 mm Device height 80.0 mm 80.0 mm 1 Device width 8.8 mm (0.5MU) 8.8 mm (0.5MU) Mounting Onto switching device -- Degree of protection, built-in IP40 IP40 Terminal protection Finger and hand touch safe according to BGV A3, OVE-EN 6 Finger and hand touch safe according to BGV A3, OVE-EN 6 Terminals Lift terminals Lift terminals 1 Terminal capacity 20-14 AWG 0.5-2.5 mm2 Terminal screws M3 (Pozidrive Z0) M3 (Pozidrive Z0) 1 Fastening torque of terminal screws 7 lb-in Max. 1.2 Nm 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-78 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1.2 Shunt Trip Release WMZTST Remote release for subsequent mounting onto WMZT Additional installation of standard auxiliary switch is possible Position indicator red-green Connection Diagram 1 1 1 1 Shunt Trip Release WMZTST WMZTST110 WMZTST415 1 Can be mounted onto WMZT/WMZH/WMZD WMZT/WMZH/WMZD 1 Operational voltage range 12-110 Vac 110-415 Vac 12-60 Vdc 110-230 Vdc 50/60 Hz 50/60 Hz 1 Frame size 45.0 mm 45.0 mm 1 Device height 105.0 mm 105.0 mm Device width 17.5 mm 17.5 mm Mounting Quick fastening with two lock-in positions on EN 50022 Degree of protection, built-in IP40 Description Electrical 2 Frequency 1 Mechanical 1 1 IP40 Terminal Protection Finger and hand touch safe according to BGV A3, OVE-EN 6 Terminals Open mouthed/lift Open mouthed/lift Terminal capacity 1 and 2 wires 18-10 AWG 18-10 AWG 1 1 1 1 Busbar Block UL 489 (Pin) Tested according to UL 489 Do not cut Extension terminal 35 mm2 WMZT35EXT for copper conductors For covering of not used pins, use busbar tag shrouds WMZT3PSHROUD Connection Diagrams Three-Pole Busbar 1 1 1 Busbar Block UL 489 (Pin) Description UL 489 IEC/EN 60947-2 480/277 Vac -- 96 Vdc -- Rated frequency 50/60 Hz -- Rated voltage -- 690 Vac 1 Electrical Rated operational voltage Two-Pole Busbar Single-Pole Busbar Overvoltage category -- III Rated impulse withstand voltage Uimp -- 9.5 kV Rated current 80A 80A Rated conditional short-circuit current AC with 350A gG -- 15 kA Short-circuit current 10 kA -- Busbar cross section -- 16 mm2 Cu Flame class according to UL 94 V0 -- 1 1 1 1 1 1 Mechanical Pollution degree -- 2 Comparative tracking index -- CTI 600 Minimum clearance (internal/external) -- > 9.5/25.4 mm Minimum creepage distance (internal/external) -- > 12.7/50.8 mm Resistance to climatic conditions -- According to DIN/ EN60068 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-79 1.2 1 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers Dimensions Approximate Dimensions in Inches (mm) WMZ Z-SV/UL-16/6 ZV-BS-UL Z-SV/UL-18...12 1 1 1 1 1 1 1 Z-EK/35/UL Z-SV/UL-16.../18 1 1 1 1 1 1 1 1 WMZT35EXT Lockout Attachment UL 489 IEC/EN 60947-2 1 # 2-14 AWG 2.5-35 mm2 1 60/75C Cu Cu 1 1 1 1 Description 0.56 in Tested according to UL 486A 14 mm Tightening torque of terminal screws # 14 AWG 2.3 Nm UL 486B # 8-12 AWG 2.8 Nm UL 486E # 6-1 AWG 4 Nm 1 1 1 1 1 1 V4-T1-80 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 489 DIN Rail Miniature Circuit Breakers 1.2 Approximate Dimensions in Inches (mm) 1 Miniature Circuit Breakers WMZ 1 0.20 (5.0) 1 1 1 4.13 (105.0) 1 1.77 (45.0) 1 1 0.39 (10.0) 1 1 1.73 (44.0) 0.70 (17.7) 1 2.36 (60.0) 1 1 WMZ UL 489 0.20 (5.5) 0.35 (8.8) 3.15 (80.0) 1 2.08 (53.0) 1.73 (44.0) 1.77 (45.0) 0.39 (10.0) 1 1 2.82 (71.6) 1.77 (45.0) 3.78 (96.0) 1.73 (44.0) 2.36 (60.0) WMZSAUXTRIP 1 2.36 (60.0) 0.22 (5.5) 1 0.35 (8.8) 1 1 WMZTAUX 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-81 1.3 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Contents FAZ Circuit Breakers Description 1 FAZ Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . WMZS Circuit Breaker . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 Optimum and Efficient Protection for Every Application 1 1 1 1 1 FAZ Circuit Breakers 1 Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eaton's FAZ DIN rail mountable circuit breaker is designed for use in control panel applications. Complete range of UL 1077 recognized DIN rail mounted miniature circuit breakers up to 63A current rating Standard ratings of 10 kAIC up to 277/480 Vac Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit 1 1 1 1 1 1 1 1 1 Powerful offering for machine and system builders The FAZ is available with B, C, D, K, S, and Z characteristics in accordance with UL 1077, CSA C22.2 No.235 and IEC 60947-2. These devices are CE marked. Application Description 1 1 Supplementary protection Control circuits Lighting Business equipment Appliances Suitable for supplementary protection Thermal-magnetic overcurrent protection Six levels of short-circuit protection, categorized by B, C, D, K, S, and Z curves Trip-free design--breaker can not be defeated by holding the handle in the ON position Captive screws cannot be lost Fulfill UL 1077, CSA C22.2 No.235 and also IEC 60947-2 Standard Field-installable shunt trip and auxiliary switch subsequent mounting Module width of only 17.7 mm (per pole) Contact position indicator (red/green) Easy installation on DIN rail Possibility for sealing the toggle in ON or OFF position 1 1 1 1 1 1 1 V4-T1-82 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Page V4-T1-82 V4-T1-83 V4-T1-83 V4-T1-84 V4-T1-90 V4-T1-93 V4-T1-100 V4-T1-103 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Standards and Certifications FAZ complies with the latest national and international standards. Discover These Advanced Features Captive Posidrive terminal screws with finger and back-ofhand protection (IP20) Breakers install on standard DIN rail Available in one-, two-, three-, four-pole, 1+N and 3+N models Trip-free design; breaker cannot be defeated by holding the handle in the ON position Color-coded indicator provides breaker status for easy troubleshooting Breaker information printed on the front of the device for quick identification UL 1077, CSA C22.2 No. 235 Apply to supplementary protectors intended for use as overcurrent, or overvoltage or undervoltage protection within an appliance or other electrical equipment where branch circuit protection is already provided, or is not required RoHS compliant VDE compliant Devices with B, C, and D curves are VDE compliant CCC Devices with B, C, and D curves are CCC compliant ABS compliant 1 1 1 1 1 1 1 1 1 1 1 Catalog Number Selection 1 FAZ C 6 / 1 SP 1 Single Package Breaker Family FAZ = Supplementary protector Trip Characteristics 1 B = 3-5X In C = 5-10X In D = 10-20X In K = 8-12X In S = 13-17X In Z = 2-3X In SP Ampere Rating 0.5 = 1 = 2 = 3 = 4 = 5 = 6 = 7 = 8 = 10 = 0.5A 1A 2A 3A 4A 5A 6A 7A 8A 10A 13 = 13A 15 = 15A 16 = 16A 20 = 20A 25 = 25A 30 = 30A 32 = 32A 40 = 40A 50 = 50A 63 = 63A Number of Poles 1 = Single-pole 2 = Two-pole 3 = Three-pole 4 = Single-pole 1N = Single-pole + neutral 3N = Three-pole + neutral = Single packaging of singlepole curve B, C and D for select amperes only Blank = Standard packaging 1 1 1 1 1 1 Note 1 I = Rated current for instantaneous trip characteristics. n 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-83 1.3 Miniature Circuit Breakers and Supplementary Protectors 1 FAZ B curve (3-5X In current rating) Designed for resistive or slightly inductive loads Response time of instantaneous trip: 3-5X In current rating UL recognized and CSA Certified as supplementary protectors For international and domestic use (conform to IEC 60947-2) UL file number 177451 1 1 1 1 1 Suitable for applications where protection against low-level short-circuit faults in control wiring is desired. Instantaneous trip is 3-5X continuous rating of device (In). Applications include PLC wiring, business equipment, lighting, appliances and some motors. Low magnetic trip point. 7200 1200 600 2.55 I : N t = 1-60 s (IN < 32A) t = 1-120 s (IN > 32A) Type B: 3 x I : t > 0.1 s N Type B: 5 x I : t < 0.1 s N 120 1 60 30 10 5 2 1 0.5 0.2 3 0.1 0.05 1 0.01 B 2 0.02 0.005 1 0.002 0.001 1 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 30 40 50 I / IN 1 Single-Pole 1 B Curve (3-5X In Current Rating)-- Designed for Resistive or Slightly Inductive Loads 1 Single-Pole 2 1 1 Two-Pole Three-Pole Catalog Amperes Number Catalog Number Catalog Number 1 FAZ-B1/1-SP FAZ-B1/2 FAZ-B1/3 2 FAZ-B2/1-SP FAZ-B2/2 3 Two-Pole 1 4 5 6 1 7 8 1 1 Specified tripping current IT = 1.45 x IN for t < 1 h 300 1 1 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1 1 1 1.45 Product Selection t [sec] 1 1.13 UL 1077 DIN Rail Supplementary Protectors Three-Pole 1 FAZ-B4/1-SP FAZ-B5/1-SP FAZ-B6/1-SP FAZ-B7/1-SP FAZ-B8/1-SP FAZ-B3/2 FAZ-B4/2 FAZ-B5/2 FAZ-B6/2 FAZ-B7/2 FAZ-B8/2 B Curve (3-5X In Current Rating)-- Designed for Resistive or Slightly Inductive Loads, continued 1 Single-Pole + Neutral Three-Pole + Neutral Catalog Amperes Number Catalog Number Catalog Number FAZ-B2/3 1 FAZ-B1/4 FAZ-B1/1N FAZ-B1/3N FAZ-B3/3 2 FAZ-B2/4 FAZ-B2/1N FAZ-B2/3N 3 FAZ-B3/4 FAZ-B3/1N FAZ-B3/3N FAZ-B5/3 4 FAZ-B4/4 FAZ-B4/1N FAZ-B4/3N FAZ-B6/3 5 FAZ-B5/4 FAZ-B5/1N FAZ-B5/3N FAZ-B7/3 6 FAZ-B6/4 FAZ-B6/1N FAZ-B6/3N FAZ-B8/3 7 FAZ-B7/4 FAZ-B7/1N FAZ-B7/3N FAZ-B8/4 FAZ-B8/1N FAZ-B8/3N FAZ-B4/3 Four-Pole Single-Pole + Neutral 10 FAZ-B10/1-SP FAZ-B10/2 FAZ-B10/3 8 12 FAZ-B12/1-SP FAZ-B12/2 FAZ-B12/3 10 FAZ-B10/4 FAZ-B10/1N FAZ-B10/3N FAZ-B13/3 12 FAZ-B12/4 FAZ-B12/1N FAZ-B12/3N FAZ-B15/3 13 FAZ-B13/4 FAZ-B13/1N FAZ-B13/3N FAZ-B16/3 15 FAZ-B15/4 FAZ-B15/1N FAZ-B15/3N FAZ-B20/3 16 FAZ-B16/4 FAZ-B16/1N FAZ-B16/3N FAZ-B25/3 20 FAZ-B20/4 FAZ-B20/1N FAZ-B20/3N FAZ-B25/4 FAZ-B25/1N FAZ-B25/3N 13 15 16 1 FAZ-B3/1-SP Four-Pole 20 FAZ-B13/1-SP FAZ-B15/1-SP FAZ-B16/1-SP FAZ-B20/1-SP FAZ-B15/2 FAZ-B16/2 FAZ-B20/2 1 30 FAZ-B30/1-SP FAZ-B30/2 FAZ-B30/3 25 1 32 FAZ-B32/1-SP FAZ-B32/2 FAZ-B32/3 30 FAZ-B30/4 FAZ-B30/1N FAZ-B30/3N 40 FAZ-B40/1-SP FAZ-B40/2 FAZ-B40/3 32 FAZ-B32/4 FAZ-B32/1N FAZ-B32/3N FAZ-B50/3 40 FAZ-B40/4 FAZ-B40/1N FAZ-B40/3N FAZ-B63/3 50 FAZ-B50/4 FAZ-B50/1N FAZ-B50/3N 63 FAZ-B63/4 FAZ-B63/1N FAZ-B63/3N 50 63 1 FAZ-B50/1-SP FAZ-B63/1-SP FAZ-B25/2 Three-Pole + Neutral 25 1 FAZ-B25/1-SP FAZ-B13/2 FAZ-B50/2 FAZ-B63/2 Notes 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 Option for single packaging on single-pole B, C and D curves only; add suffix SP when ordering. 1 1 V4-T1-84 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.3 Miniature Circuit Breakers and Supplementary Protectors Suitable for applications where medium levels of inrush current are expected. Instantaneous trip is 5-10X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits and coils. Medium magnetic trip point. 1 1.45 7200 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1200 Type C: 5 x I : t > 0.1 s N 1 Type C: 10 x I : t < 0.1 s N Specified tripping current IT = 1.45 x IN for t < 1 h 600 300 1 120 1 60 30 1 10 t [sec] FAZ C curve (5-10X In current rating) Designed for inductive loads Response time of instantaneous trip: 5-10X In current rating UL recognized and CSA Certified as supplementary protectors For international and domestic use (conform to IEC 60947-2) UL file number 177451 1.13 UL 1077 DIN Rail Supplementary Protectors 5 1 2 1 1 0.5 0.2 1 2 0.1 1 0.05 C 1 0.02 0.01 0.005 1 0.002 0.001 1 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 30 40 50 1 I / IN Single-Pole C Curve (5-10X In Current Rating)-- Designed Inductive Loads 1 Single-Pole 2 Two-Pole Three-Pole Two-Pole Three-Pole Catalog Amperes Number Catalog Number Catalog Number 0.5 FAZ-C0.5/1-SP FAZ-C0.5/2 FAZ-C0.5/3 1 FAZ-C1/1-SP FAZ-C1/2 FAZ-C1/3 1.6 FAZ-C1.6/1-SP FAZ-C1.6/2 FAZ-C1.6/3 2 FAZ-C2/1-SP FAZ-C2/2 FAZ-C2/3 3 FAZ-C3/1-SP FAZ-C3/2 FAZ-C3/3 4 FAZ-C4/1-SP FAZ-C4/2 FAZ-C4/3 5 FAZ-C5/1-SP FAZ-C5/2 FAZ-C5/3 6 FAZ-C6/1-SP FAZ-C6/2 FAZ-C6/3 7 FAZ-C7/1-SP FAZ-C7/2 FAZ-C7/3 8 FAZ-C8/1-SP FAZ-C8/2 FAZ-C8/3 10 FAZ-C10/1-SP FAZ-C10/2 FAZ-C10/3 13 FAZ-C13/1-SP FAZ-C13/2 FAZ-C13/3 15 FAZ-C15/1-SP FAZ-C15/2 FAZ-C15/3 16 FAZ-C16/1-SP FAZ-C16/2 FAZ-C16/3 20 FAZ-C20/1-SP FAZ-C20/2 FAZ-C20/3 25 FAZ-C25/1-SP FAZ-C25/2 FAZ-C25/3 30 FAZ-C30/1-SP FAZ-C30/2 FAZ-C30/3 32 FAZ-C32/1-SP FAZ-C32/2 FAZ-C32/3 40 FAZ-C40/1-SP FAZ-C40/2 FAZ-C40/3 50 FAZ-C50/1-SP FAZ-C50/2 FAZ-C50/3 63 FAZ-C63/1-SP FAZ-C63/2 FAZ-C63/3 Four-Pole C Curve (5-10X In Current Rating)-- Designed Inductive Loads, continued 1 Single-Pole + Neutral Three-Pole + Neutral Catalog Amperes Number Catalog Number Catalog Number 0.5 FAZ-C0.5/4 FAZ-C0.5/1N FAZ-C0.5/3N 1 FAZ-C1/4 FAZ-C1/1N FAZ-C1/3N 1.6 FAZ-C1.6/4 FAZ-C1.6/1N FAZ-C1.6/3N 2 FAZ-C2/4 FAZ-C2/1N FAZ-C2/3N 3 FAZ-C3/4 FAZ-C3/1N FAZ-C3/3N 4 FAZ-C4/4 FAZ-C4/1N FAZ-C4/3N 5 FAZ-C5/4 FAZ-C5/1N FAZ-C5/3N 6 FAZ-C6/4 FAZ-C6/1N FAZ-C6/3N 7 FAZ-C7/4 FAZ-C7/1N FAZ-C7/3N 8 FAZ-C8/4 FAZ-C8/1N FAZ-C8/3N 10 FAZ-C10/4 FAZ-C10/1N FAZ-C10/3N 13 FAZ-C13/4 FAZ-C13/1N FAZ-C13/3N 15 FAZ-C15/4 FAZ-C15/1N FAZ-C15/3N 16 FAZ-C16/4 FAZ-C16/1N FAZ-C16/3N 20 FAZ-C20/4 FAZ-C20/1N FAZ-C20/3N 25 FAZ-C25/4 FAZ-C25/1N FAZ-C25/3N 30 FAZ-C30/4 FAZ-C30/1N FAZ-C30/3N 32 FAZ-C32/4 FAZ-C32/1N FAZ-C32/3N 40 FAZ-C40/4 FAZ-C40/1N FAZ-C40/3N 50 FAZ-C50/4 FAZ-C50/1N FAZ-C50/3N 63 FAZ-C63/4 FAZ-C63/1N FAZ-C63/3N Four-Pole Single-Pole + Neutral Three-Pole + Neutral Notes 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 Option for single packaging on single-pole B, C and D curves only; add suffix SP when ordering. Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-85 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.3 1 1 1 1 1 Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 10-20X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies. 1.45 FAZ D curve (10-20X In current rating) Designed for highly inductive loads Response time of instantaneous trip: 10-20X In current rating UL recognized and CSA Certified as supplementary protectors For international and domestic use (conform to IEC 60947-2) UL file number 177451 1.13 UL 1077 DIN Rail Supplementary Protectors 7200 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1200 Specified tripping current IT = 1.45 x IN for t < 1 h 600 300 1 60 30 10 5 2 1 0.2 3 0.1 2 0.05 1 D 0.02 0.01 0.005 1 0.002 0.001 1 0.0005 1 2 3 4 1 5 6 7 8 9 10 15 20 30 40 50 I / IN 1 Single-Pole D Curve (10-20X In Current Rating)-- Designed for Inductive Loads 1 Single-Pole 2 1 Catalog Amperes Number 1 1 Two-Pole 1 FAZ-D1/1-SP FAZ-D1/3 3 FAZ-D3/1-SP FAZ-D4/1-SP FAZ-D2/2 FAZ-D3/2 FAZ-D4/2 FAZ-D3/3 FAZ-D5/3 6 FAZ-D6/1-SP FAZ-D6/2 FAZ-D6/3 13 15 16 FAZ-D8/1-SP FAZ-D10/1-SP FAZ-D13/1-SP FAZ-D15/1-SP FAZ-D16/1-SP FAZ-D7/2 FAZ-D8/2 FAZ-D10/2 FAZ-D13/2 FAZ-D15/2 FAZ-D16/2 FAZ-D10/3 FAZ-D13/3 1 FAZ-D20/2 FAZ-D20/3 25 FAZ-D25/1-SP FAZ-D25/2 FAZ-D25/3 1 30 32 1 40 50 3 1 63 3 1 FAZ-D32/1-SP FAZ-D40/1-SP FAZ-D50/1-SP FAZ-D63/1-SP FAZ-D32/2 FAZ-D40/2 FAZ-D50/2 FAZ-D63/2 Three-Pole + Neutral FAZ-D16/3 FAZ-D20/1-SP FAZ-D30/2 Single-Pole + Neutral FAZ-D8/3 20 FAZ-D30/1-SP Catalog Amperes Number FAZ-D7/3 FAZ-D15/3 D Curve (10-20X In Current Rating)-- Designed for Inductive Loads, continued 1 Four-Pole FAZ-D4/3 FAZ-D5/2 FAZ-D7/1-SP Four-Pole FAZ-D2/3 FAZ-D5/1-SP 10 1 FAZ-D2/1-SP FAZ-D1/2 5 8 Three-Pole Catalog Number FAZ-D0.5/3 7 1 Three-Pole Catalog Number FAZ-D0.5/1-SP FAZ-D0.5/2 4 1 Two-Pole 0.5 2 1 1 Type D: 20 x I : t < 0.1 s N 0.5 1 1 t = 1-60 s (IN < 32A) t = 1-120 s (IN > 32A) Type D: 10 x I : t > 0.1 s N 1 1 1 2.55 I : N 120 t [sec] 1 Miniature Circuit Breakers and Supplementary Protectors FAZ-D30/3 FAZ-D32/3 FAZ-D40/3 FAZ-D50/3 FAZ-D63/3 Single-Pole + Neutral Three-Pole + Neutral Catalog Number Catalog Number 0.5 FAZ-D0.5/4 FAZ-D0.5/1N FAZ-D0.5/3N 1 FAZ-D1/4 FAZ-D1/1N FAZ-D1/3N 2 FAZ-D2/4 FAZ-D2/1N FAZ-D2/3N 3 FAZ-D3/4 FAZ-D3/1N FAZ-D3/3N 4 FAZ-D4/4 FAZ-D4/1N FAZ-D4/3N 5 FAZ-D5/4 FAZ-D5/1N FAZ-D5/3N 6 FAZ-D6/4 FAZ-D6/1N FAZ-D6/3N 7 FAZ-D7/4 FAZ-D7/1N FAZ-D7/3N 8 FAZ-D8/4 FAZ-D8/1N FAZ-D8/3N 10 FAZ-D10/4 FAZ-D10/1N FAZ-D10/3N 13 FAZ-D13/4 FAZ-D13/1N FAZ-D13/3N 15 FAZ-D15/4 FAZ-D15/1N FAZ-D15/3N 16 FAZ-D16/4 FAZ-D16/1N FAZ-D16/3N 20 FAZ-D20/4 FAZ-D20/1N FAZ-D20/3N 25 FAZ-D25/4 FAZ-D25/1N FAZ-D25/3N 30 FAZ-D30/4 FAZ-D30/1N FAZ-D30/3N 32 FAZ-D32/4 FAZ-D32/1N FAZ-D32/3N 40 FAZ-D40/4 FAZ-D40/1N FAZ-D40/3N 50 c FAZ-D50/4 FAZ-D50/1N FAZ-D50/3N 63 c FAZ-D63/4 FAZ-D63/1N FAZ-D63/3N Notes 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 Option for single packaging on single-pole B, C and D curves only; add suffix SP when ordering. 3 IEC 60947-2 only. 1 1 V4-T1-86 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 1.13 1.45 FAZ K curve (8-12X In current rating) Designed for motors, transformers and upstream electronics Response time of instantaneous trip: 8-12X In current rating UL recognized and CSA Certified as supplementary protectors For international and domestic use (conform to IEC 60947-2) UL file number 177451 7200 3600 Specified non-tripping current Int = 1.05 u In for t > 1 h Specified tripping current It = 1.30 u In for t < 1 h 1200 600 300 120 60 30 Suitable for applications where medium levels of inrush current are expected. Instantaneous trip is 8-12X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits and coils. Medium magnetic trip point. 1 1 1 1 t (sec) 10 5 1 2 1 0.5 1 K 0.2 0.1 0.05 1 1 0.02 0.01 0.005 1 0.002 0.001 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 1 30 40 50 1 U-rated Current Single-Pole K Curve (8-12X In Current Rating)-- Designed for Inductive Loads 12 Two-Pole Three-Pole Catalog Amperes Number Catalog Number Catalog Number 0.5 FAZ-K0.5/1 FAZ-K0.5/2 FAZ-K0.5/3 1 FAZ-K1/1 FAZ-K1/2 FAZ-K1/3 1.6 FAZ-K1.6/1 FAZ-K1.6/2 FAZ-K1.6/3 2 FAZ-K2/1 FAZ-K2/2 FAZ-K2/3 3 FAZ-K3/1 FAZ-K3/2 FAZ-K3/3 4 FAZ-K4/1 FAZ-K4/2 FAZ-K4/3 6 FAZ-K6/1 FAZ-K6/2 FAZ-K6/3 8 FAZ-K8/1 FAZ-K8/2 FAZ-K8/3 10 FAZ-K10/1 FAZ-K10/2 FAZ-K10/3 13 FAZ-K13/1 FAZ-K13/2 FAZ-K13/3 16 FAZ-K16/1 FAZ-K16/2 FAZ-K16/3 20 FAZ-K20/1 FAZ-K20/2 FAZ-K20/3 25 FAZ-K25/1 FAZ-K25/2 FAZ-K25/3 32 FAZ-K32/1 FAZ-K32/2 FAZ-K32/3 40 FAZ-K40/1 FAZ-K40/2 FAZ-K40/3 50 FAZ-K50/1 FAZ-K50/2 FAZ-K50/3 63 FAZ-K63/1 FAZ-K63/2 FAZ-K63/3 Single-Pole Two-Pole Three-Pole 3 Four-Pole K Curve (8-12X In Current Rating)-- Designed for Inductive Loads, continued 12 Single-Pole + Neutral Three-Pole + Neutral Catalog Amperes Number Catalog Number Catalog Number 0.5 FAZ-K0.5/4 FAZ-K0.5/1N FAZ-K0.5/3N 1 FAZ-K1/4 FAZ-K1/1N FAZ-K1/3N 1.6 FAZ-K1.6/4 FAZ-K1.6/1N FAZ-K1.6/3N 2 FAZ-K2/4 FAZ-K2/1N FAZ-K2/3N 3 FAZ-K3/4 FAZ-K3/1N FAZ-K3/3N 4 FAZ-K4/4 FAZ-K4/1N FAZ-K4/3N 6 FAZ-K6/4 FAZ-K6/1N FAZ-K6/3N 8 FAZ-K8/4 FAZ-K8/1N FAZ-K8/3N 10 FAZ-K10/4 FAZ-K10/1N FAZ-K10/3N 13 FAZ-K13/4 FAZ-K13/1N FAZ-K13/3N 16 FAZ-K16/4 FAZ-K16/1N FAZ-K16/3N 20 FAZ-K20/4 FAZ-K20/1N FAZ-K20/3N 25 FAZ-K25/4 FAZ-K25/1N FAZ-K25/3N 32 FAZ-K32/4 FAZ-K32/1N FAZ-K32/3N 40 FAZ-K40/4 FAZ-K40/1N FAZ-K40/3N 50 FAZ-K50/4 FAZ-K50/1N FAZ-K50/3N 63 FAZ-K63/4 FAZ-K63/1N FAZ-K63/3N Four-Pole 3 Single-Pole + Neutral Three-Pole + Neutral Notes 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 These breakers are available by special order and may result in additional delivery time. 3 Two-piece box order, quantities of 2. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-87 1.3 1 1 1 1 1 UL 1077 DIN Rail Supplementary Protectors Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13-17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies. 1 1 Specified non-tripping current Int = 1.05 u In for t > 1 h Specified tripping current It = 1.30 u In for t < 1 h 1200 600 300 120 60 30 10 5 2 1 0.5 S 0.02 0.01 0.005 1 0.002 0.001 0.0005 1 1 1 2 3 4 5 6 7 8 9 10 15 20 U-rated Current Single-Pole S Curve (13-17X In Current Rating)-- Designed for Inductive Loads 12 Single-Pole 3 Two-Pole Amperes Catalog Number Catalog Number 1 FAZ-S1/1 FAZ-S1/2 2 FAZ-S2/1 FAZ-S2/2 3 FAZ-S3/1 FAZ-S3/2 4 FAZ-S4/1 FAZ-S4/2 6 FAZ-S6/1 FAZ-S6/2 10 FAZ-S10/1 FAZ-S10/2 1 16 FAZ-S16/1 FAZ-S16/2 20 FAZ-S20/1 FAZ-S20/2 1 25 FAZ-S25/1 FAZ-S25/2 32 FAZ-S32/1 FAZ-S32/2 40 FAZ-S40/1 FAZ-S40/2 1 1 1 1 7200 3600 0.2 0.1 0.05 1 1 1.05 1.30 FAZ S curve (13-17X In current rating) Designed for control circuits with high inrush Response time of instantaneous trip: 13-17X In current rating UL recognized and CSA Certified as supplementary protectors For international and domestic use (conform to IEC 60947-2) UL file number 177451 t (sec) 1 Miniature Circuit Breakers and Supplementary Protectors Two-Pole 1 1 Notes 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 These breakers are available by special order and may result in additional delivery time. 3 Two-piece box order, quantities of 2. 1 1 1 1 1 1 1 1 1 V4-T1-88 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 30 40 50 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 1.05 1.30 FAZ Z curve (2-3X In current rating) Designed for protection of electronic devices Response time of instantaneous trip: 2-3X In current rating UL recognized and CSA Certified as supplementary protectors For international and domestic use (conform to IEC 60947-2) 7200 3600 Specified non-tripping current Int = 1.05 u In for t > 1 h Specified tripping current It = 1.30 u In for t < 1 h 1200 600 300 Suitable for applications where low levels of inrush current are expected. Instantaneous trip is 2-3X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits and coils. Medium magnetic trip point. 120 60 30 1 1 1 1 t (sec) 10 5 1 2 1 0.5 1 Z 0.2 0.1 0.05 1 1 0.02 0.01 0.005 1 0.002 0.001 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 1 30 40 50 1 U-rated Current Single-Pole Z Curve (2-3X In Current Rating)-- Designed for Inductive Loads 12 Amperes Two-Pole Single-Pole 3 Two-Pole Catalog Number Catalog Number 0.5 FAZ-Z0.5/1 FAZ-Z0.5/2 1 FAZ-Z1/1 FAZ-Z1/2 1.6 FAZ-Z1.6/1 FAZ-Z1.6/2 2 FAZ-Z2/1 FAZ-Z2/2 3 FAZ-Z3/1 FAZ-Z3/2 4 FAZ-Z4/1 FAZ-Z4/2 6 FAZ-Z6/1 FAZ-Z6/2 8 FAZ-Z8/1 FAZ-Z8/2 10 FAZ-Z10/1 FAZ-Z10/2 13 FAZ-Z13/1 FAZ-Z13/2 16 FAZ-Z16/1 FAZ-Z16/2 20 FAZ-Z20/1 FAZ-Z20/2 25 FAZ-Z25/1 FAZ-Z25/2 32 FAZ-Z32/1 FAZ-Z32/2 40 FAZ-Z40/1 FAZ-Z40/2 50 FAZ-Z50/1 FAZ-Z50/2 63 FAZ-Z63/1 FAZ-Z63/2 Three-Pole Four-Pole Z Curve (2-3X In Current Rating)-- Designed for Inductive Loads, continued 12 Three-Pole Four-Pole Amperes Catalog Number Catalog Number 0.5 FAZ-Z0.5/3 FAZ-Z0.5/4 1 FAZ-Z1/3 FAZ-Z1/4 1.6 FAZ-Z1.6/3 FAZ-Z1.6/4 2 FAZ-Z2/3 FAZ-Z2/4 3 FAZ-Z3/3 FAZ-Z3/4 4 FAZ-Z4/3 FAZ-Z4/4 6 FAZ-Z6/3 FAZ-Z6/4 8 FAZ-Z8/3 FAZ-Z8/4 10 FAZ-Z10/3 FAZ-Z10/4 13 FAZ-Z13/3 FAZ-Z13/4 16 FAZ-Z16/3 FAZ-Z16/4 20 FAZ-Z20/3 FAZ-Z20/4 25 FAZ-Z25/3 FAZ-Z25/4 32 FAZ-Z32/3 FAZ-Z32/4 40 FAZ-Z40/3 FAZ-Z40/4 50 FAZ-Z50/3 FAZ-Z50/4 63 FAZ-Z63/3 FAZ-Z63/4 1 1 1 1 1 1 1 1 1 1 1 1 1 Notes 1 In North America, these switches are UL recognized and CSA Certified as supplementary protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 These breakers are available by special order and may result in additional delivery time. 3 Two-piece box order, quantities of 2. 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-89 1.3 1 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Accessories FAZ Auxiliary Contacts and Voltage Trips Circuit Diagram Description Catalog Number Standard Auxiliary Contacts 1 1 1 1 14 12 1 1 1 Rated Operational Voltage 1NO/1NC Installs on left side of FAZ or shunt trip Max. one per FAZ (1077) device Switches when FAZ is tripped electrically or manually 230 Vac FAZ-XHIN11 1 changeover contact Installs on left side of FAZ or shunt trip Max. one per FAZ (1077) device Switches when FAZ is tripped electrically or manually 230 Vac FAZ-XHINW1 Small selector screw changes mode Two Form C (changeover) contacts Installs on left side of FAZ or shunt trip Auxiliary contacts switch when FAZ is tripped electrically or manually Trip indicating contact switches only when FAZ is tripped electrically 230 Vac FAZ-XAM002 Prevents FAZ from operating unless 115 Vac FAZ-XUA(115VAC) 230 Vac FAZ-XUA(230VAC) 400 Vac FAZ-XUA(400VAC) 12-110 Vac 12-60 Vdc FAZ-XAA-C-12-110VAC 110-415 Vac 110-230 Vdc FAZ-XAA-C-110415VAC 11 Auxiliary/Trip Indicating Contact 1 1 1 Two-pole auxiliary mode 1 1 1 1 Trip indicating mode Undervoltage Trip 1 D1 D2 voltage is present Installs on left side of FAZ Includes test button C1 Allows remote trip of FAZ Installs on left side of FAZ U 1 1 1 1 Shunt Trip 1 C2 1 1 1 1 1 1 Allowable Combinations of Accessories AUX AUX TRIP FAZ AUX or V4-T1-90 FAZ or Circuit Breaker 1 FAZ AUX TRIP Shunt Trip Circuit Breaker UnderV Trip Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Circuit Breaker 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Busbar System Description 1 Rated Operational Current Number of Poles per Device Number of Terminals Catalog Number 1 80A 1 57 BB-UL-18/1P-1M/57 2 56 BB-UL-18/2P-2M/56 3 57 BB-UL-18/3P-3M/57 1 57 BB-UL-25/1P-1M/57 2 56 BB-UL-25/2P-2M/56 3 57 BB-UL-25/3P-3M/57 1 Without Auxiliary Contacts For connecting FAZ supplementary protectors without auxiliary contacts. May be fed from line or load side. 1 1 1 1 1 WMZS WMZS WMZS 100A 1 1 1 1 Auxiliary/Trip Indicating Contacts For connecting FAZ supplementary protectors with auxiliary contacts. May be fed from line or load side. FAZ 1 80A 1 37 BB-UL-18/1P-1,5M/37 2 46 BB-UL-18/2P+AS-2,5M/46 3 48 BB-UL-18/3P+AS-3,5M/48 1 37 BB-UL-25/1P-1,5M/37 2 46 BB-UL-25/2P+AS-2,5M/46 3 48 BB-UL-25/3P+AS-3,5M/48 1 1 1 1 1 FAZ 100A 1 1 1 1 1 Note 1 Bus may be center fed for high current capacity. 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-91 1.3 1 Incoming Terminal Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Pin Type Incoming Supply Terminals 1 Description Catalog Number Accommodates conductors BB-UL-TEP/35 1 from 6-35 mm2/#10-2 AWG 4-5.5 Nm/35-50 lb-in Two- and three-pole 1 Incoming Terminal Description 1 1 Fork Connector Incoming Terminal 1 1 1 Accommodates conductors BB-UL-TEPA/35 4-5.5 Nm/35-50 lb-in Busbar Terminal Cover Protective Accessories Description 1 1 1 Catalog Number from 6-35 mm2/#10-2 AWG 1 1 Pin Type Incoming Supply Terminals-- Single-Phase Only Description Catalog Number For covering unused terminals BB-IP/5 Prevents reactivation of the device IS/SPE-1TE during maintenance Holds one padlock Padlock Hasp 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-92 Bus Incoming Supply Terminals Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 50 mm2 #14-1 AWG 75 Deg wire 115 A/Y, 480V UL 160 A/Y 690V IEC Catalog Number BB-UL-TE/50 Busbar End Cap Description Poles Catalog Number Install after cutting busbar Protects end of busbar 2 and 3 BB-UL-EC/3 1 BB-UL-EC/1 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Technical Data and Specifications 1 Tripping Characteristics 1.30 1 1 1.45 1.13 1.05 Even though not required by NEC or CEC for supplementary protectors, Eaton's FAZ devices are current limiting, which means that they interrupt fault currents within one half cycle. Current limiting devices offer superior protection by reducing peak let-through current and energy. 7200 3600 Time-current characteristic acc. to UL 1077 Conventional 2.55 I : N non-tripping current t = 1-60 s (IN < 32A) t = 1-120 s (IN < 32A) Int = 1.13 IN: t > 1 h 1200 600 300 Conventional tripping current It = 1.45 IN: t < 1 h 120 60 30 Type B: 3 I : t > 0.1 s N Type B: 5 I : t < 0.1 s N Type C: 5 I : t > 0.1 s N Type C: 10 I : t < 0.1 s N Type D: 10 IN: t > 0.1 s Type D: 20 IN: t < 0.1 s 10 5 t (sec) Trip Curves Chart Eaton FAZ supplementary protectors are available with six different tripping characteristics, including Type B, C, D, K, S and Z. Definitions for each trip curve are contained on the ordering pages and can be used to determine the optimal characteristic for your application. For example, low-level short-circuit faults in control wiring, such as PLCs, are best protected by devices with Type B trip characteristics (3-5X continuous rating of the device (In). 1 1 1 1 1 1 2 1 0.5 D 0.2 0.1 0.05 Z B C K 1 1 S 1 0.02 0.01 0.005 1 0.002 0.001 0.0005 1 1 2 3 4 5 6 7 8 9 10 15 20 30 40 50 I/In 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-93 1.3 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors FAZ Miniature Circuit Breakers Technical Data Description B Curve C Curve D Curve 1 Electrical 1 Approvals UR (UL 1077), CSA (CSA 22.2 No. 235), CE Standards IEC/EN 60947-2 1 Short-circuit trip response 3-5 In 5-10 In 10-20 In 1 Current range 1-63A 0.5-63A 0.5-40A 277 Vac 48 Vdc 277 Vac 48 Vdc 277 Vac 48 Vdc 480Y/277 Vac 96 Vdc 480Y/277 Vac 96 Vdc 480Y/277 Vac 96 Vdc Thermal tripping characteristics Single-pole Multi-pole 1.35 x In @ 40C 1.45 x In @ 40C 1.35 x In @ 40C 1.45 x In @ 40C 1.35 x In @ 40C 1.45 x In @ 40C Short-circuit ratings (at max. voltage) Single-pole Two-, three-pole Single-pole Two poles in series 10 kA (5 kA for 40-63A device) 10 kA (5 kA for 40-63A device) 10 kA @ 48 Vdc 10 kA @ 96 Vdc 10 kA (5 kA for 40-63A device) 10 kA (5 kA for 40-63A device) 10 kA @ 48 Vdc 10 kA @ 96 Vdc 5 kA 5 kA 10 kA @ 48 Vdc 10 kA @ 96 Vdc Current range 1-63A 0.5-63A 0.5-63A Maximum voltage ratings--IEC 68898-1 Single-pole Two-, three-pole 230 Vac 230/400 Vac 230 Vac 230/400 Vac 230 Vac 230/400 Vac 240 Vac 48 Vdc 240/415 Vac 96 Vdc 240 Vac 48 Vdc 240/415 Vac 96 Vdc 240 Vac 48 Vdc 240/415 Vac 96 Vdc Thermal tripping characteristics Single-pole Multi-pole > 1 hour @ 1.05 x In < 1 hour @ 1.3 x In > 1 hour @ 1.05 x In < 1 hour @ 1.3 x In > 1 hour @ 1.05 x In < 1 hour @ 1.3 x In Interrupt ratings (at max. voltage) IEC 60947-2 IEC 60898 Operational switching capacity Max. backup fuse [gL/gG] Rated impulse withstand--Uimp Rated insulation voltage--Ui 15 kA 10 kA 7.5 kA 125A 4000 Vac 440 Vac 15 kA 10 kA 7.5 kA 125A 4000 Vac 440 Vac 15 kA (10 kA for 50 and 63A) 10 kA (50 and 63A not available) 7.5 kA 125A 4000 Vac 440 Vac 3 > 10,000 (1 operation = ON/OFF) 10g-120 ms -40 to +167F (-40 to +75C) -40 to +185F (-40 to +85C) Nylon 3 > 10,000 (1 operation = ON/OFF) 10g-120 ms -40 to +167F (-40 to +75C) -40 to +185F (-40 to +85C) Nylon 3 > 10,000 (1 operation = ON/OFF) 10g-120 ms -40 to +167F (-40 to +75C) -40 to +185F (-40 to +85C) Nylon Standard front dimension Device height Terminal protection Mounting width per pole 80 mm Finger and back-of-hand proof to IEC 536 17.5 mm 80 mm Finger and back-of-hand proof to IEC 536 17.5 mm 80 mm Finger and back-of-hand proof to IEC 536 17.5 mm Mounting Degree of protection Terminals top and bottom Supply connection IEC/EN 60715 top-hat rail IP20 Twin-purpose terminals Line or load side IEC/EN 60715 top-hat rail IP20 Twin-purpose terminals Line or load side IEC/EN 60715 top-hat rail IP20 Twin-purpose terminals Line or load side Terminal capacity [mm2] Torque Imperial torque 1 x 25 (AWG 4-18)/2 x 10 (AWG 8-18) 2.4 Nm 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 0.8-2 mm As required 1 x 25 (AWG 4-18)/2 x 10 (AWG 8-18) 2.4 Nm 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 0.8-2 mm As required 1 x 25 (AWG 4-18)/2 x 10 (AWG 8-18) 2.4 Nm 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 0.8-2 mm As required 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Supplementary Protectors--UL/CSA Maximum voltage ratings--UL/CSA Single-pole, single-pole + neutral Two-, three-pole, four-pole and three-pole + neutral Two poles in series Miniature Circuit Breaker--IEC Maximum voltage ratings--IEC 60947-2 Single-pole Two-, three-pole Two poles in series Environmental/General Selectivity class Lifespan (operations) Shock (IEC 68-2-22) Operating temperature range Shipment and short-term storage Housing material Mechanical Thickness of busbar material Mounting position 1 V4-T1-94 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1.3 FAZ Miniature Circuit Breakers Technical Data, continued Description B Curve C Curve 1 D Curve 1 Electrical Approvals UR (UL 1077), CSA (CSA 22.2 No. 235), CE 1 Standards IEC/EN 60947-2, E177451, 204453 Short-circuit trip response 8-12 In 13-17 In 2-3 In 1 0.5-63A 0.5-40A 1-63A 1 277 Vac 48 Vdc 277 Vac 48 Vdc 277 Vac 48 Vdc 1 480Y/277 Vac 96 Vdc 480Y/277 Vac 96 Vdc 480Y/277 Vac 96 Vdc 1 Thermal tripping characteristics Single-pole Multi-pole 1.35 x In @ 40C 1.45 x In @ 40C 1.35 x In @ 40C 1.45 x In @ 40C 1.35 x In @ 40C 1.45 x In @ 40C Short-circuit ratings (at max. voltage) Single-pole Single-pole + neutral Two-, three-, four-pole Two poles in series 5 kA @ 277 Vac 5 kA @ 277 Vac 5 kA @ 480Y/277 Vac -- 5 kA @ 277 Vac 5 kA @ 277 Vac 5 kA @ 480Y/277 Vac -- 5 kA @ 277 Vac 5 kA @ 277 Vac 5 kA @ 480Y/277 Vac -- 0.5-63A 0.5-40A 1-63A 1 240 Vac 240 Vac 240 Vac 240/415 Vac 240/415 Vac 240/415 Vac 1 Thermal tripping characteristics Single-pole Multi-pole > 1 Hour @ 1.05 x In < 1 Hour @ 1.3 x In > 1 Hour @ 1.05 x In < 1 Hour @ 1.3 x In > 1 Hour @ 1.05 x In < 1 Hour @ 1.3 x In Interrupt ratings (at max. voltage) IEC 60947-2 Operational switching capacity Max. backup fuse [gL/gG] Rated impulse withstand--Uimp Rated insulation voltage--Ui 15 kA 7.5 kA 125A 4000 Vac 440 Vac 10 kA 7.5 kA 125A 4000 Vac 440 Vac 10 kA 7.5 kA 125A 4000 Vac 440 Vac 3 > 10,000 (1 operation = ON/OFF) 10g-120 ms -40 to +167F (-40 to +75C) -40 to +185F (-40 to +85C) Nylon 3 > 10,000 (1 operation = ON/OFF) 10g-120 ms -40 to +167F (-40 to +75C) -40 to +185F (-40 to +85C) Nylon 3 > 10,000 (1 operation = ON/OFF) 10g-120 ms -40 to +167F (-40 to +75C) -40 to +185F (-40 to +85C) Nylon Supplementary Protectors--UL/CSA Current range Maximum voltage ratings--UL/CSA Single-pole, single-pole + neutral Two-, three-, four-pole and three-pole + neutral Two poles in series 1 1 1 1 Miniature Circuit Breaker--IEC Current range Maximum voltage ratings--IEC 60947-2 Single-pole, single-pole + neutral Two-, three-, four-pole, three-pole + neutral 1 1 1 1 1 Environmental/General Selectivity class Lifespan (operations) Shock (IEC 68-2-22) Operating temperature range Shipment and short-term storage Housing material 1 1 1 Mechanical Standard front dimension Device height Terminal protection Mounting width per pole 80 mm Finger and back-of-hand proof to IEC 536 17.7 mm 80 mm Finger and back-of-hand proof to IEC 536 17.7 mm 80 mm Finger and back-of-hand proof to IEC 536 17.7 mm Mounting Degree of protection Terminals top and bottom Supply connection IEC/EN 60715 top-hat rail IP20 Twin-purpose terminals Line or load side IEC/EN 60715 top-hat rail IP20 Twin-purpose terminals Line or load side IEC/EN 60715 top-hat rail IP20 Twin-purpose terminals Line or load side Terminal capacity [mm2] 1 x 25 (AWG 4-18) / 2 x 10 (AWG 8-18) 2.4 Nm 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 0.8-2 mm As required 1 x 25 (AWG 4-18) / 2 x 10 (AWG 8-18) 2.4 Nm 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 0.8-2 mm As required 1 x 25 (AWG 4-18) / 2 x 10 (AWG 8-18) 2.4 Nm 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 0.8-2 mm As required Torque Imperial torque Thickness of busbar material Mounting position 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-95 1.3 1 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Let-Through Energy I2t Let-Through Energy ID Characteristic B and C Characteristic B and C i2dt 105 [A2s] 8 63 A 50 A 40 A 32 A 25 A 20 A 16 A 13 A 10 A 6 1 4 1 6A 4A 1 104 3A 1 6 8 10 5 6 4 3 2 0.5 1 1.5 2 3 4 5 6 7 8 910 15 0.5 1 1.5 2 3 4 5 6 7 8 910 15 Icc rms [kA] Icc rms [kA] Characteristic D Characteristic D 5 i2dt 10 [A2s] 8 40 A 32 A 25 A 20 A 16 A 13 A 6 4 lD 104 9 [A] 8 40 A 32 A 25 A 20 A 16 A 13 A 10 A 6A 7 6 10 A 5 6A 4 2 1.5 1 6 1 4 1 0.5 A 8 104 1 0.5 A 1 A 1 1 1A 3 1 1 1.5 2 1 1 2 1.5 1 1 3 103 1 1 6A 4A 3A 4 1 1 5 2A 2A 1 1 6 4 1.5 1 63 A 50 A 40 A 32 A 25 A 16 A20 A 13 A 10 A 7 2 1 1 lD 104 9 [A] 8 3 8 2 1.5 103 2 1.5 103 5 8 6 4 1 2 0.5 1 1 1.5 2 3 4 5 6 7 8 910 15 0.5 Icc rms [kA] V4-T1-96 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1 1.5 2 3 4 5 6 7 8 910 15 Icc rms [kA] 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Let-Through Energy I2t Characteristic K lD [A] 1 Characteristic S lD [A] 104 8 1 104 1 8 6 4 3 63 A 50 A 40 A 32 A 25 A 20 A 13 A 16 A 6 10 A 6A 4A 3A 4 2A 2 1 40 A 32 A 25 A 20 A 16 A 10 A 1 1 6A 4A 3A 2A 3 1 1.6 A 1 1.5 1A 1 2 1A 103 1 1.5 1 103 5 1 0.5 A 1 1 5 0.5 1 1.5 2 3 4 5 6 7 8 9 10 Icc rms [kA] 0.5 1 1.5 2 3 4 5 6 1 7 8 9 10 Icc rms [kA] 1 Characteristic Z lD [A] 1 104 1 8 6 1 63 A 50 A 40 A 32 A 25 A 20 A 16 A 1 4 10 A 8A 3 1 6A 2 1 4A 3A 1 1.5 1 2A 103 1 1 5 1 1.6 A 1A 1 0.5 A 1 0.5 1 1.5 2 3 4 5 6 7 8 9 10 1 Icc rms [kA] Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-97 1.3 1 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Influence of the Ambient Temperature on the Thermal Tripping Behavior Corrected values of the rated current dependent on the ambient temperature Ambient Temperature T In (A) -40C -30C -20C -10C 0C 10C 20C 30C 35C 40C 45C 50C 55C 60C 65C 70C 75C 0.16 0.20 0.20 0.19 0.19 0.18 0.17 0.17 0.16 0.16 0.15 0.15 0.15 0.14 0.14 0.14 0.14 0.13 1 0.25 0.32 0.31 0.30 0.29 0.28 0.27 0.26 0.25 0.25 0.24 0.24 0.23 0.23 0.22 0.22 0.21 0.21 0.50 0.64 0.62 0.60 0.58 0.56 0.54 0.52 0.50 0.49 0.48 0.47 0.46 0.45 0.44 0.43 0.42 0.41 1 0.75 0.96 0.93 0.90 0.87 0.84 0.81 0.78 0.75 0.74 0.73 0.71 0.69 0.68 0.66 0.65 0.64 0.62 1.00 1.30 1.20 1.20 1.20 1.10 1.10 1.00 1.00 0.99 0.97 0.95 0.93 0.90 0.89 0.87 0.85 0.83 1 1.50 1.90 1.90 1.80 1.70 1.70 1.60 1.60 1.50 1.50 1.50 1.40 1.40 1.40 1.30 1.30 1.30 1.20 1.60 2.00 2.00 1.90 1.90 1.80 1.70 1.70 1.60 1.60 1.50 1.50 1.50 1.40 1.40 1.40 1.40 1.30 1 2.00 2.60 2.50 2.40 2.30 2.20 2.20 2.10 2.00 2.00 1.90 1.90 1.90 1.80 1.80 1.70 1.70 1.70 2.50 3.20 3.10 3.00 2.90 2.80 2.70 2.60 2.50 2.50 2.40 2.40 2.30 2.30 2.20 2.20 2.10 2.10 1 3.00 3.80 3.70 3.60 3.50 3.40 3.30 3.10 3.00 3.00 2.90 2.80 2.80 2.70 2.70 2.60 2.50 2.50 3.50 4.50 4.40 4.20 4.10 3.90 3.80 3.70 3.50 3.40 3.40 3.30 3.20 3.20 3.10 3.00 3.00 2.90 1 4.00 5.10 5.00 4.80 4.70 4.50 4.30 4.20 4.00 3.90 3.90 3.80 3.70 3.60 3.50 3.50 3.40 3.30 5.00 6.40 6.20 6.00 5.80 5.60 5.40 5.20 5.00 4.90 4.80 4.70 4.60 4.50 4.40 4.30 4.20 4.10 1 6.00 7.70 7.50 7.20 7.00 6.70 6.50 6.30 6.00 5.90 5.80 5.70 5.60 5.40 5.30 5.20 5.10 5.00 7.00 9.00 8.70 8.40 8.20 7.80 7.60 7.40 7.00 6.90 6.80 6.70 6.50 6.30 6.20 6.10 6.00 5.80 1 8.00 10.20 9.90 9.60 9.30 9.00 8.70 8.40 8.00 7.90 7.70 7.60 7.40 7.20 7.10 6.90 6.80 6.60 1 10.00 13.00 12.00 12.00 12.00 11.00 11.00 10.00 10.00 9.90 9.70 9.50 9.30 9.00 8.90 8.70 8.50 8.30 12.00 15.00 15.00 14.00 14.00 13.00 13.00 13.00 12.00 12.00 12.00 11.00 11.00 11.00 11.00 10.00 10.00 10.00 13.00 17.00 16.00 16.00 15.00 15.00 14.00 14.00 13.00 13.00 13.00 12.00 12.00 12.00 12.00 11.00 11.00 11.00 15.00 19.00 19.00 18.00 17.00 17.00 16.00 16.00 15.00 15.00 15.00 14.00 14.00 14.00 13.00 13.00 13.00 12.00 16.00 20.00 20.00 19.00 19.00 18.00 17.00 17.00 16.00 16.00 15.00 15.00 15.00 14.00 14.00 14.00 14.00 13.00 20.00 26.00 25.00 24.00 23.00 22.00 22.00 21.00 20.00 20.00 19.00 19.00 19.00 18.00 18.00 17.00 17.00 17.00 1 25.00 32.00 31.00 30.00 29.00 28.00 27.00 26.00 25.00 25.00 24.00 24.00 23.00 23.00 22.00 22.00 21.00 21.00 32.00 41.00 40.00 38.00 37.00 36.00 35.00 33.00 32.00 32.00 31.00 30.00 30.00 29.00 28.00 28.00 27.00 26.00 1 35.00 45.00 43.00 41.00 41.00 38.00 38.00 36.00 35.00 35.00 34.00 33.00 32.00 32.00 32.00 30.00 29.00 29.00 40.00 51.00 50.00 48.00 47.00 45.00 43.00 42.00 40.00 39.00 39.00 38.00 37.00 36.00 35.00 35.00 34.00 33.00 1 50.00 64.00 62.00 60.00 58.00 56.00 54.00 52.00 50.00 49.00 48.00 47.00 46.00 45.00 44.00 43.00 42.00 41.00 63.00 81.00 78.00 76.00 73.00 71.00 68.00 66.00 63.00 62.00 61.00 60.00 58.00 57.00 56.00 55.00 53.00 52.00 1 1 1 1 1 Influence of the Mains Frequency Influence of the mains frequency on the tripping behavior IMA of the instantaneous release 1 Mains Frequency f [Hz] 16 2/3 50 60 100 200 300 400 91 100 101 106 115 134 141 1 IMA(f)IMA (50 Hz) [%] 1 Load Carrying Capacity of Adjoining Miniature Circuit Breakers 1 1 1 1 1 Rated Diversity Factor 1 1.00 0.90 0.80 0.70 1 1 2 3 4 5 6 7 8 Number of Circuit Breakers 1 V4-T1-98 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1.3 Accessories Technical Data 1 FAZ-XHIN FAZ-XAM002 FAZ-XAA-C FAZ-XUA 1 Contact function 1A + 1B 2 C/O -- -- -- -- 1 Rated operational voltage Un 250 Vac -- 115 Vac 230 Vac 400 Vac 1 Voltage range -- 12-110 Vac 12-60 Vdc -- 1 Voltage range -- 110-415 Vac 110-230 Vdc -- 1 1 Description Electrical Closing threshold [x Un] -- -- 0.8 Tripping threshold [x Un] -- -- 0.5 Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz General use (UL/CSA) AC--230/240 Vac DC--110/120 Vdc 2/2A 0.5/0.5A -- -- -- -- 1 1 1 Pilot duty A600/Q600 -- -- Conventional free air thermal current Ith 4A -- -- Rated operational current AC-13 Ie AC-15 Ie DC-13 Ie 1 3A (250 Vac) 2A (250 Vac) 0.5A (110 Vdc) -- -- -- -- -- -- 1 1 Rated insulation voltage Ui 250 Vac -- -- Minimum operating voltage per contract Umin 5 Vdc -- -- Rated impulse withstand voltage (1.2/50) Uimp 2.5 kV -- -- Rated conditional short-circuit current with 6A backup fuse ISC 1 kA -- -- Max. admissible backup fuse 4A gL -- -- 1 Standard front dimension 45 mm 45 mm 45 mm 1 Device height 80 mm 80 mm 80 mm Mounting width 8.8 mm 17.6 mm 17.8 mm Mounting On MCB IEC/EN 60715 top-hat rail IEC/EN 60715 top-hat rail 1 1 Mechanical 1 IP40 IP40 IP40 1 Terminal protection Protection against electric shock to IEC 536 Protection against electric shock to IEC 536 Protection against electric shock to IEC 536 1 Terminals Lift terminals Twin-purpose terminals Twin-purpose terminals Terminal capacity Solid Flexible 0.5-2.5 mm2 0.5-2.5 mm2 1-2.5 mm2 1-2.5 mm2 2 x (1-2.5) mm2 2 x (1-2.5) mm2 1 Tightening torque of terminal screws 0.8-1.0 Nm (7-9 lb-in) 2.4 Nm (21 lb-in) 0.8 Nm (7 lb-in) Degree of protection enclosed 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-99 1.3 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Dimensions Approximate Dimensions in Inches (mm) 1 Miniature Circuit Breakers 1 FAZ 0.74 (9.4) 1 1 1.77 (45.0) 3.15 (80.0) 1 1 1 1 1 1 1 1.40 (35.4) 0.70 (17.8) 2.09 (53.1) 0.22 (5.5) 2.79 (70.8) 1.73 (44.0) 2.36 (60.0) Auxiliary Contacts FAZ-XHI11 and FAZ-XH1NW1 FAZ-XAM002 1 1 3.15 (80.0) 1 3.15 (80.0) 1.77 (45.0) 1.77 (45.0) 1 1 0.35 (8.8) 1 1 1 0.22 (5.5) 1.73 (44.0) 0.35 (8.8) 2.36 (60.0) 0.22 (5.5) Shunt Releases Undervoltage Releases FAZ-XAA FAZ-XUA 1.73 (44.0) 2.36 (60.0) 1 1 3.15 (80.0) 1 1.77 (45.0) 3.15 (80.0) 1.77 (45.0) 1 1 1 0.70 (17.8) 1.03 (26.2) 1 0.22 (5.5) 1.20 (30.5) 1.73 (44.0) 0.39 (10.0) 0.70 (17.8) 0.22 (5.5) 2.36 (60.0) 1 1 1 V4-T1-100 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.73 (44.0) 2.36 (60.0) 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Approximate Dimensions in Inches (mm) 1 1 Busbar and Accessory Weights and Dimensions Unit Weight (kg) Length Width Height Catalog Number 0.29 39.72 (1009.0) 0.59 (15.0) 0.59 (15.0) BB-UL-18/1P-1M/57 0.64 39.02 (991.0) 0.87 (22.0) 1.46 (37.0) BB-UL-18/2P-2M/56 0.83 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) BB-UL-18/3P-3M/57 0.26 38.78 (985.0) 0.59 (15.0) 0.59 (15.0) BB-UL-18/1P-1.5M/37 0.63 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) BB-UL-18/2P+AS-2.5M/46 0.79 38.66 (982.0) 0.87 (22.0) 1.46 (37.0) BB-UL-18/3P+AS-3.5M/48 0.36 39.72 (1009.0) 0.59 (15.0) 0.59 (15.0) BB-UL-25/1P-1M/57 0.79 39.02 (991.0) 0.87 (22.0) 1.46 (37.0) BB-UL-25/2P-2M/56 1.04 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) BB-UL-25/3P-3M/57 0.31 38.78 (985.0) 0.59 (15.0) 0.59 (15.0) BB-UL-25/1P-1.5M/37 0.73 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) BB-UL-25/2P+AS-2.5M/46 0.97 38.66 (982.0) 0.87 (22.0) 1.46 (37.0) BB-UL-25/3P+AS-3.5M/48 0.03 2.36 (60.0) 0.67 (17.0) 1.14 (29.0) BB-UL-TEP/35 0.03 1.42 (36.0) 0.67 (17.0) 1.14 (29.0) BB-UL-TEPA/35 0.03 1.57 (40.0) 0.71 (18.0) 1.18 (30.0) BB-UL-TE/50 0.003 3.35 (85.0) 0.47 (12.0) 0.94 (24.0) BB-IP/5 0.001 0.55 (14.0) 0.20 (5.0) 0.39 (10.0) BB-UL-EC/3 0.001 0.94 (24.0) 0.87 (22.0) 0.39 (10.0) BB-UL-EC/1 1 1 1 1 1 1 1 1 1 1 1 1 1 L W 1 1 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 H 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-101 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 Application Guidelines 1 Example of UL 489 and UL 1077 Application 1 UL 489 Breaker 1 1 1 1 UL 489 Branch UL 1077 Internal Receptacle 1 1 Electronics 1 1 1 1 UL 489 Branch UL 1077 Other Sensitive Devices 1 External Motor M UL 489 Branch External Motor UL 489 Branch 1 M 1 1 External Receptacle UL 1077 HACR Motor Controller 1 1 Example of UL 489 and UL 1077 Application 1 1 UL 489 circuit breakers 1 Used for branch circuit protection, internal/external receptacles, external motors and HACR equipment (heating, air conditioning and refrigeration). 1 UL 1077 supplementary protectors 1 Used for overcurrent protection within appliances or electrical equipment, where branch circuit protection is already provided or not required. 1 Note: UL 4 89 devices can be used in place of UL 1077; UL 1077 devices cannot be used in place of UL 489. 1 1 1 1 1 V4-T1-102 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1.3 Contents WMZS Circuit Breakers Description FAZ Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . WMZS Circuit Breaker Standards and Certifications. . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V4-T1-82 V4-T1-104 V4-T1-104 V4-T1-105 V4-T1-107 V4-T1-110 V4-T1-117 1 1 1 1 1 1 1 1 1 1 1 WMZS Circuit Breaker Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eaton's WMZS DIN rail mountable circuit breaker is designed for use in control panel applications.The WMZS is available with B, C and D characteristics in accordance with UL 1077, CSA C22.2 No.235 and IEC 60947-2. Application Description Supplementary protection: Control circuits Lighting Business equipment Appliances Complete range of UL 1077 Recognized DIN rail mounted miniature circuit breakers up to 63A current rating Standard ratings of 10 kAIC at 277/480 Vac Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit Offers supplementary protection Thermal-magnetic overcurrent protection Three levels of shortcircuit protection, categorized by B, C and D curves 1 Trip-free design--breaker can not be defeated by holding the handle in the ON position Captive screws cannot be lost Fulfill UL 1077, CSA C22.2 No.235 and also IEC 60947-2 Standard Field-installable shunt trip and auxiliary switch subsequent mounting Module width of only 0.69 inches (17.5 mm) per pole Contact Position Indicator (red/green) Easy installation on DIN rail Possibility for sealing the toggle in ON or OFF position 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-103 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Standards and Certifications 1 1 1 1 1 1 Advanced Features Breakers install on standard DIN rail Captive posidrive terminal screws with finger and backof-hand protection (IP20) Available in single-, two- and three-pole models Trip-free design; breaker cannot be defeated by holding the handle in the ON position Color-coded indicator provides breaker status for easy troubleshooting Breaker information printed on the front of the device for quick identification 1 1 1 Worldwide Acceptance WMZS Supplementary Protectors are UL Recognized for use in the United States in accordance with NFPA(R) 70 (NEC). The devices comply with UL 1077 and CSA 22.2 No. 235, meeting the requirements for supplementary protectors. These devices are for international and domestic use, and also comply with IEC 60947-2 and are CE marked. These devices are RoHS compliant. 1 1 1 1 1 1 1 1 Catalog Number Selection 1 WMZS 1 B 10 1 Breaker Family WMZS = Supplementary Protector 1 Ampere Rating Number of Poles 1 = Single-pole 2 = Two-pole 3 = Three-pole 1 Protective Curve B = B Curve (3-5X In) C = C Curve (5-10X In) D = D Curve (10-20X In) 1 1 1 1 1 1 1 1 1 V4-T1-104 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 00 = 0.5A 01 = 1A 02 = 2A 03 = 3A 04 = 4A 05 = 5A 06 = 6A 07 = 7A 08 = 8A 10 = 10A 13 = 13A 15 = 15A 16 = 16A 20 = 20A 25 = 25A 30 = 30A 32 = 32A 40 = 40A 50 = 50A 63 = 63A Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1.3 Product Selection 1 WMZS Product Selection--B Curve (3-5X In Current Rating) Suitable for applications where protection against low level short circuit faults in control wiring is desired. Instantaneous trip is 3-5X continuous rating of device (In). Applications include PLC wiring, business equipment, lighting, appliances and some motors. Low magnetic trip point. Single-Pole Two-Pole Three-Pole B Curve (3-5X In Current Rating)-- Designed for Resistive or Slightly Inductive Loads 123 Single-Pole Two-Pole Three-Pole Amperes Catalog Number Catalog Number Catalog Number 6 WMZS1B06 WMZS2B06 WMZS3B06 7 WMZS1B07 WMZS2B07 WMZS3B07 8 WMZS1B08 WMZS2B08 WMZS3B08 10 WMZS1B10 WMZS2B10 WMZS3B10 13 WMZS1B13 WMZS2B13 WMZS3B13 15 WMZS1B15 WMZS2B15 WMZS3B15 16 WMZS1B16 WMZS2B16 WMZS3B16 20 WMZS1B20 WMZS2B20 WMZS3B20 25 WMZS1B25 WMZS2B25 WMZS3B25 30 WMZS1B30 WMZS2B30 WMZS3B30 32 WMZS1B32 WMZS2B32 WMZS3B32 40 WMZS1B40 WMZS2B40 WMZS3B40 50 WMZS1B50 WMZS2B50 WMZS3B50 63 WMZS1B63 WMZS2B63 WMZS3B63 WMZS Product Selection--C Curve (5-10X In Current Rating) Suitable for applications where medium levels of inrush current are expected. Instantaneous trip is 5-10X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits, and coils. Medium magnetic trip point. Single-Pole Two-Pole Three-Pole C Curve (5-10X In Current Rating)-- Designed for Inductive Loads 145 Single-Pole Two-Pole Three-Pole Amperes Catalog Number Catalog Number Catalog Number 0.5 WMZS1C00 WMZS2C00 WMZS3C00 1 WMZS1C01 WMZS2C01 WMZS3C01 2 WMZS1C02 WMZS2C02 WMZS3C02 3 WMZS1C03 WMZS2C03 WMZS3C03 4 WMZS1C04 WMZS2C04 WMZS3C04 5 WMZS1C05 WMZS2C05 WMZS3C05 6 WMZS1C06 WMZS2C06 WMZS3C06 7 WMZS1C07 WMZS2C07 WMZS3C07 8 WMZS1C08 WMZS2C08 WMZS3C08 10 WMZS1C10 WMZS2C10 WMZS3C10 13 WMZS1C13 WMZS2C13 WMZS3C13 15 WMZS1C15 WMZS2C15 WMZS3C15 16 WMZS1C16 WMZS2C16 WMZS3C16 20 WMZS1C20 WMZS2C20 WMZS3C20 25 WMZS1C25 WMZS2C25 WMZS3C25 30 WMZS1C30 WMZS2C30 WMZS3C30 32 WMZS1C32 WMZS2C32 WMZS3C32 40 WMZS1C40 WMZS2C40 WMZS3C40 50 WMZS1C50 WMZS2C50 WMZS3C50 63 WMZS1C63 WMZS2C63 WMZS3C63 Notes 1 In North America, these switches are UL recognized and CSA certified as Supplementary Protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 Designed for resistive or slightly inductive loads. 3 Response time of instantaneous trip: 3-5X I current rating. n 4 Designed for inductive loads. 5 Response time of instantaneous trip: 5-10X I current rating. n 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-105 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 1 1 1 1 1 WMZS Product Selection--D Curve (10-20X In Current Rating) Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 10-20X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies. Single-Pole D Curve (10-20X In Current Rating)-- Designed for Inductive Loads 123 Single-Pole Two-Pole Three-Pole Amperes Catalog Number Catalog Number Catalog Number 1 0.5 WMZS1D00 WMZS2D00 WMZS3D00 1 1 WMZS1D01 WMZS2D01 WMZS3D01 2 WMZS1D02 WMZS2D02 WMZS3D02 3 WMZS1D03 WMZS2D03 WMZS3D03 4 WMZS1D04 WMZS2D04 WMZS3D04 5 WMZS1D05 WMZS2D05 WMZS3D05 6 WMZS1D06 WMZS2D06 WMZS3D06 7 WMZS1D07 WMZS2D07 WMZS3D07 8 WMZS1D08 WMZS2D08 WMZS3D08 10 WMZS1D10 WMZS2D10 WMZS3D10 13 WMZS1D13 WMZS2D13 WMZS3D13 15 WMZS1D15 WMZS2D15 WMZS3D15 1 16 WMZS1D16 WMZS2D16 WMZS3D16 1 20 WMZS1D20 WMZS2D20 WMZS3D20 25 WMZS1D25 WMZS2D25 WMZS3D25 30 WMZS1D30 WMZS2D30 WMZS3D30 32 WMZS1D32 WMZS2D32 WMZS3D32 40 WMZS1D40 WMZS2D40 WMZS3D40 1 1 Two-Pole 1 1 1 1 Three-Pole 1 1 1 1 1 1 Notes 1 In North America, these switches are UL recognized and CSA certified as Supplementary Protection devices. Per the intent of NEC (National Electrical Code), Article 240, and CEC (Canadian Electrical Code), Part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. 2 Designed for highly inductive loads. 3 Response time of instantaneous trip: 10-20X I current rating. n 1 1 1 1 1 1 1 1 V4-T1-106 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Accessories 1 WMZS Auxiliary Contacts and Voltage Trips Module Circuit Diagram Description Rated Operational Voltage Catalog Number 230 Vac WMZSAUX 1 1 Standard Auxiliary Contacts H 12 14 11 1NO/1NC Installs on left side of WMZS or shunt trip Max. one per WMZS (1077) device Switches when WMZS is tripped electrically or manually 1 1 1 1 2 1 Auxiliary/Trip Indicating Contact 1 2 N 4 OFF 1.11 Small selector screw changes mode Two Form C (changeover) contacts Installs on left side of WMZS or shunt trip Auxiliary contacts switch when WMZS is tripped electrically or manually Trip indicating contact switches only when WMZS is tripped electrically 4.11 1.14 4.12 1.12 4.14 230 Vac WMZSAUXTRIP 1 1 1 1 Undervoltage Trip Prevents WMZS from operating unless voltage is present Installs on left side of WMZS Includes test button D1 115 Vac WMZSUVR115 230 Vac WMZSUVR230 400 Vac WMZSUVR400 U D2 1 1 1 1 1 Shunt Trip Allows remote trip of WMZS Installs on left side of WMZS 110-415 Vac 1 WMZSST415 110-230 Vdc 12-110 Vac C1 1 WMZSST110 1 12-60 Vdc C2 1 1 1 Allowable Combinations of Accessories 1 AUX AUX TRIP FAZ or AUX FAZ AUX TRIP FAZ 1 or Circuit Breaker Shunt Trip Circuit Breaker UnderV Trip 1 Circuit Breaker 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-107 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 1 Busbar System 1 Description 1 Rated Operational Current (A) Number of Poles per Device Number of Terminals Catalog Number 80 1 57 WMZS1P57T 2 56 WMZS2P56T 3 57 WMZS3P57T 1 57 WMZS1P57T25 2 56 WMZS2P56T25 3 57 WMZS3P57T25 1 37 WMZS1P37TAUX 2 46 WMZS2P46TAUX 3 48 WMZS3P48TAUX 1 37 WMZS1P37T25AUX 2 46 WMZS2P46T25AUX 3 48 WMZS3P48T25AUX Without Auxiliary Contacts For connecting WMZS Supplementary Protectors without auxiliary contacts. May be fed from line or load side. 1 1 1 1 WMZS WMZS WMZS 100 1 1 1 1 1 1 Auxiliary/Trip Indicating Contact For connecting WMZS Supplementary Protectors with auxiliary contacts. May be fed from line or load side. 80 1 1 1 WMZS WMZS 100 1 1 1 1 1 1 WMZSBBTC 1 WMZS3CAP or WMZS1CAP 1 1 1 WMZSBCONA 1 35 lb-in (4 Nm) 1 50 lb-in (5.5 Nm) 22 lb-in (2.5 Nm) 1 V4-T1-108 WMZS35EXT Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 Incoming Terminal Pin Type Incoming Supply Terminals Description Accommodates conductors from 6-35 mm2 /#10-2 AWG Incoming Terminal Bus Incoming Supply Terminals Catalog Number Description Catalog Number WMZS35EXT 50 mm2 WMZSBCONA 1 1 1 #14-1 AWG 4-5.5 Nm/35-50 16 lb-in 75 Deg Wire 1 115A/Y, 480V UL 1 Finger-safe connection 160A/Y 690V IEC 1 Protective Accessories Busbar Terminal Cover Description Catalog Number For covering unused terminals WMZSBBTC Fork Connector Two- and Three-Pole 1 Busbar End Cap Description Number of Poles Catalog Number 1 Install after cutting busbar 2 and 3 WMZS3CAP 1 Protects end of busbar 1 1 1 Fork Connector Two- and Three-Pole Padlock Hasp 1 Prevents reactivation of the device during maintenance WMZS1CAP WMZPLK 1 1 Holds one padlock 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-109 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 Technical Data and Specifications 1 Trip Curve Charts Three Tripping Curves to Choose Eaton WMZS Supplementary Protectors are available with three different tripping characteristics, including Type B, C and D. Definitions for each trip curve are contained on the ordering pages and can be used to determine the optimal characteristic for your application. For example, low level short-circuit faults in control wiring, such as PLCs, are best protected by devices with Type B trip characteristics (3 to 5X continuous rating of the device (In). 1 1 1 1 1 1 1 1 1 WMZS Tripping Curves 7200 Even though not required by NEC or CEC for Supplementary Protectors, Eaton's WMZS devices are current limiting, which means they interrupt fault currents within one half cycle. Current limiting devices offer superior protection by reducing peak let-through current and energy. 3600 Time-current characteristic conventional non-tripping current Int = 1.13 IN: t > 1 h 2 1 1200 600 acc. to UL 1077 2.55 IN: t = 1 - 60 s (IN < 32A) t = 1 - 120 s (IN < 32A) conventional tripping current It = 1.45 IN: t < 1 h 300 120 Type B: 3 IN: t > 0.1 s Type B: 5 IN: t < 0.1 s Type C: 5 IN: t > 0.1 s 3 60 t [sec] 1.3 Type C: 10 IN: t < 0.1 s 30 Type D: 10 IN: t > 0.1 s 10 Type D: 20 IN: t < 0.1 s 5 2 1 3 0.5 0.2 5 0.1 0.05 B6 4 9 7 C 8 D 0.02 1 0.01 0.005 1 0.002 0.001 0.0005 1 1 1 2 3 4 5 6 7 8 910 I / IN 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-110 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 15 20 30 40 50 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors B Curve D Curve 1.13 1.45 1.13 1.45 7200 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1200 2.55 IN: t = 1 - 60 s (IN < 32A) t = 1 - 120 s (IN > 32A) Type B: 3 x IN: t > 0.1 s Specified tripping current IT = 1.45 x IN for t < 1 h 600 300 Type B: 5 x IN: t < 0.1 s Type C: 5 x IN: t > 0.1 s 120 1 60 30 7200 1200 600 120 Type D: 10 x IN: t > 0.1 s 60 10 10 5 5 0.5 Type B: 3 x IN: t > 0.1 s Type B: 5 x IN: t < 0.1 s Type C: 5 x IN: t > 0.1 s Type C: 10 x IN: t < 0.1 s 1 Type D: 10 x IN: t > 0.1 s 30 Type D: 20 x IN: t < 0.1 s 1 2.55 IN: t = 1 - 60 s (IN < 32A) t = 1 - 120 s (IN > 32A) Specified tripping current IT = 1.45 x IN for t < 1 h 300 Type C: 10 x IN: t < 0.1 s 2 1 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 t [sec] t [sec] 1 Type D: 20 x IN: t < 0.1 s 3 B4 2 1 C D 0.02 0.02 0.01 0.01 0.005 0.005 0.002 0.002 0.001 0.0005 0.001 0.0005 1 2 3 4 15 5 6 7 8 910 20 30 40 50 B4 2 6 D 1 1 1 1 2 3 4 5 6 7 8 910 15 20 30 40 50 1 1 1 C Curve 1.13 1.45 1 7200 Specified non-tripping current INT = 1.13 x IN for t > 1 h 3600 1200 300 1 2.55 IN: t = 1 - 60 s (IN < 32A) t = 1 - 120 s (IN > 32A) 1 Type B: 3 x IN: t > 0.1 s Specified tripping current IT = 1.45 x IN for t < 1 h 600 Type B: 5 x IN: t < 0.1 s 1 Type C: 5 x IN: t > 0.1 s 120 Type C: 10 x IN: t < 0.1 s 1 60 1 Type D: 10 x IN: t > 0.1 s 30 Type D: 20 x IN: t < 0.1 s 1 10 t [sec] 1 1 7 5 C I / IN I / IN 1 1 3 0.1 0.05 7 5 6 1 1 2 1 0.5 0.1 0.05 1 1 0.2 0.2 1 5 1 2 1 1 1 0.5 1 0.2 3 0.1 0.05 B4 2 7 5 C 6 D 1 0.02 1 0.01 0.005 1 0.002 0.001 0.0005 1 2 3 4 5 6 7 8 910 15 20 30 1 40 50 1 I / IN Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-111 1.3 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors WMZ Miniature Circuit Breaker Technical Data Description B Curve C Curve D Curve 1 Electrical 1 Approvals UR (UL 1077), CSA (CSA 22.2 No. 235), CE Standards IEC/EN 60947-2 Short-circuit trip response 3-5 In 5-10 In 10-20 In 6-63A 0.5-63A 0.5-40A 277 Vac 48 Vdc 277 Vac 48 Vdc 277 Vac 48 Vdc 480Y/277 Vac 96 Vdc 480Y/277 Vac 96 Vdc 480Y/277 Vac 96 Vdc Thermal tripping characteristics Single-pole Multi-pole 1.35 x In at 40C 1.45 x In at 40C 1.35 x In at 40C 1.45 x In at 40C 1.35 x In at 40C 1.45 x In at 40C Short-circuit ratings (at max. voltage) Single-pole Two-, three-pole Single-pole Two poles in series 10 kA (5 kA for 40-63A device) 10 kA (5 kA for 40-63A device) 10 kA at 48 Vdc 10 kA at 96 Vdc 10 kA (5 kA for 40-63A device) 10 kA (5 kA for 40-63A device) 10 kA at 48 Vdc 10 kA at 96 Vdc 5 kA 5 kA 10 kA at 48 Vdc 10 kA at 96 Vdc 6-63A 0.5-63A 0.5-40A 230 Vac 48 Vdc 230/400 Vac 230 Vac 48 Vdc 230/400 Vac 230 Vac 48 Vdc 230/400 Vac 240 Vac 48 Vdc 240/415 Vac 240 Vac 48 Vdc 240/415 Vac 240 Vac 48 Vdc 240/415 Vac Thermal tripping characteristics Single-pole Multi-pole > 1 hour at 1.05 x In < 1 hour at 1.3 x In > 1 hour at 1.05 x In < 1 hour at 1.3 x In > 1 hour at 1.05 x In < 1 hour at 1.3 x In Interrupting ratings (at max. voltage) IEC 60947-2 IEC 60898 15 kA 10 kA 15 kA 10 kA 15 kA 10 kA Operational switching capacity 7.5 kA 7.5 kA 7.5 kA Max. back-up fuse [gL/gG] 125A 125A 125A Rated impulse withstand--Uimp 4000 Vac 4000 Vac 4000 Vac Rated insulation voltage--Ui 440 Vac 440 Vac 440 Vac 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Supplementary Protectors--UL/CSA Current range Maximum voltage ratings--UL/CSA Single-pole Two-, three-pole Two poles in series Miniature Circuit Breaker--IEC Current range Maximum voltage ratings--IEC 60947-2 Single-pole Two-, three-pole Maximum voltage ratings--IEC 60898 Single-pole Two-, three-pole 1 1 1 1 1 1 1 1 1 1 V4-T1-112 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1.3 WMZ Miniature Circuit Breaker Technical Data, continued Description 1 B Curve C Curve D Curve Selectivity class 3 3 3 Lifespan (operations) > 10,000 (1 operation = ON/OFF) > 10000 (1 operation = ON/OFF) > 10000 (1 operation = ON/OFF) Shock (IEC 68-2-22) 10g-120 ms 10g-120 ms 10g-120 ms Operating temperature range 23 to 104F (-5 to 40C) 23 to 104F (-5 to 40C) 23 to 104F (-5 to 40C) Shipment and short-term storage -40 to 185F (-40 to 85C) -40 to 185F (-40 to 85C) -40 to 185F (-40 to 85C) Housing material Nylon Nylon Nylon Standard Front Dimension Device height Terminal protection Mounting width per pole 80 mm Finger and back-of-hand proof to IEC 536 17.5 mm 80 mm Finger and back-of-hand proof to IEC 536 17.5 mm 80 mm Finger and back-of-hand proof to IEC 536 17.5 mm Mounting IEC/EN 60715 top-hat rail IEC/EN 60715 top-hat rail IEC/EN 60715 top-hat rail Degree of protection IP20 IP20 IP20 Terminals top and bottom Twin-purpose terminals Twin-purpose terminals Twin-purpose terminals Supply connection Line or load side Line or load side Line or load side Terminal capacity [mm2] 1 x 25 (AWG 4-18) / 2 x 10 (AWG 8-18) 1 x 25 (AWG 4-18) / 2 x 10 (AWG 8-18) 1 x 25 (AWG 4-18) / 2 x 10 (AWG 8-18) Torque 2.4 Nm 2.4 Nm 2.4 Nm 1 Imperial torque 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 21 lb-in (AWG 18-12), 25 lb-in (AWG 10-8), 36 lb-in (AWG 6-4) 1 Thickness of busbar material 0.8-2 mm 0.8-2 mm 0.8-2 mm Mounting position As required As required As required 1 1 Environmental/General 1 1 1 1 Mechanical 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-113 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 Let-Through Energy I2t Let-Through Current ID 1 Characteristic B and C Characteristic B and C 1 1 1 1 1 1 1 1 1 1 1 i2dt 10 5 [A2s] 8 63 A 50 A 6 40 A 32 A 25 A 20 A 16 A 13 A 10 A 4 lD 10 4 9 [A] 8 63 A 50 A 40 A 32 A 25 A 20 A 16 A 7 6 13 A 10 A 5 4 6A 4A 3A 2 6A 4A 1.5 10 3 4 3A 2 8 2A 6 2A 1.5 4 10 3 WMZS-...-B4HI 2 1A 1.5 0.5 A 1 A 10 3 0.5 A 5 8 6 4 3 2 0.5 1 1.5 2 3 4 5 6 7 8 910 15 0.5 1 1.5 2 3 4 1 5 6 7 8 910 15 Icc rms [kA] Icc rms [kA] 1 1 1 1 1 1 1 1 1 1 1 1 Characteristic D Characteristic D 5 i2dt 10 [A2s] 8 40 A 32 A 25 A 20 A 16 A 13 A 6 lD 10 4 9 [A] 8 40 A 32 A 25 A 20 A 7 6 16 A 13 A 10 A 4 10 A 5 6A 4 6A 2 3 1.5 10 4 2 8 6 1.5 4 10 3 2 1.5 10 3 5 8 6 4 1 2 0.5 1 1 1.5 2 3 4 5 6 7 8 910 15 0.5 Icc rms [kA] 1 1 V4-T1-114 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1 1.5 2 3 4 5 6 7 8 910 15 Icc rms [kA] 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Influence of the Ambient Temperature on the Thermal Tripping Behavior Corrected values of the rated current dependent on the ambient temperature 1 1 Ambient Temperature T In (A) -25C -20C -10C 0C 10C 20C 30C 35C 40C 45C 50C 55C 60C 0.16 0.2 0.19 0.19 0.18 0.17 0.17 0.16 0.16 0.15 0.15 0.15 0.14 0.14 0.25 0.31 0.3 0.29 0.28 0.27 0.26 0.25 0.25 0.24 0.24 0.23 0.23 0.22 0.5 0.61 0.6 0.58 0.56 0.54 0.52 0.5 0.49 0.48 0.47 0.46 0.45 0.44 0.75 0.92 0.9 0.87 0.84 0.81 0.78 0.75 0.74 0.73 0.71 0.69 0.68 0.66 1 1.2 1.2 1.2 1.1 1.1 1 1 0.99 0.97 0.95 0.93 0.9 0.89 1.5 1.8 1.8 1.7 1.7 1.6 1.6 1.5 1.5 1.5 1.4 1.4 1.4 1.3 1.6 2 1.9 1.9 1.8 1.7 1.7 1.6 1.6 1.5 1.5 1.5 1.4 1.4 2 2.4 2.4 2.3 2.2 2.2 2.1 2 2 1.9 1.9 1.9 1.8 1.8 2.5 3.1 3 2.9 2.8 2.7 2.6 2.5 2.5 2.4 2.4 2.3 2.3 2.2 3 3.7 3.6 3.5 3.4 3.3 3.1 3 3 2.9 2.8 2.8 2.7 2.7 3.5 4.3 4.2 4.1 3.9 3.8 3.7 3.5 3.4 3.4 3.3 3.2 3.2 3.1 4 4.9 4.8 4.7 4.5 4.3 4.2 4 3.9 3.9 3.8 3.7 3.6 3.5 5 6.1 6 5.8 5.6 5.4 5.2 5 4.9 4.8 4.7 4.6 4.5 4.4 6 7.3 7.2 7 6.7 6.5 6.3 6 5.9 5.8 5.7 5.6 5.4 5.3 7 8.6 8.4 8.1 7.9 7.6 7.4 7 6.9 6.8 6.7 6.6 6.4 6.3 8 9.8 9.6 9.3 9 8.7 8.4 8 7.9 7.7 7.6 7.4 7.2 7.1 10 12 12 12 11 11 10 10 9.9 9.7 9.5 9.3 9 8.9 12 15 14 14 13 13 13 12 12 12 11 11 11 11 13 16 16 15 15 14 14 13 13 13 12 12 12 12 15 18 18 17 17 16 16 15 15 15 14 14 14 13 16 20 19 19 18 17 17 16 16 15 15 15 14 14 20 24 24 23 22 22 21 20 20 19 19 19 18 18 25 31 30 29 28 27 26 25 25 24 24 23 23 22 32 39 38 37 36 35 33 32 32 31 30 30 29 28 40 49 48 47 45 43 42 40 39 39 38 37 36 35 50 61 60 58 56 54 52 50 49 48 47 46 45 44 63 77 76 73 71 68 66 63 62 61 60 58 57 56 Influence of the Mains Frequency Influence of the mains frequency on the tripping behavior IMA of the instantaneous release 16 2/3 50 60 100 200 300 400 IMA(f)IMA (50 Hz) [%] 91 100 101 106 115 134 141 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Load Carrying Capacity of Adjoining Miniature Circuit Breakers 1 1.00 Rated Diversity Factor 1 1 Mains Frequency f [Hz] Description 1 1 0.90 1 1 0.80 1 1 0.70 1 2 3 4 5 6 7 8 1 Number of Circuit Breakers Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-115 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors 1 Accessories Technical Data 1 Description WMZSAUX WMZSAUXTRIP WMZSST WMZSUVR -- Electrical 1 Contact function 1 Rated operational voltage Un 1A + 1B -- 2 C/O -- -- 250 Vac -- 115 Vac--WMZSUVR115 230 Vac--WMZSUVR230 1 400 Vac--WMZSUVR400 1 Voltage range WMZSST110 1 Voltage range WMZSST415 1 1 1 1 1 1 1 1 1 1 1 -- 12-110 Vac -- -- 12-60 Vdc -- -- 110-415 Vac -- -- 110-230 Vdc -- Closing threshold [x Un] -- -- 0.8 Tripping threshold [x Un] -- -- 0.5 Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 2/2A -- -- General use (UL/CSA) AC--230/240 Vac 0.5/0.5A -- -- Pilot duty DC--110/120 Vdc A600/Q600 -- -- Conventional free air thermal current Ith 4A -- -- AC-13 Ie 3A (250 Vac) -- -- AC-15 Ie 2A (250 Vac) -- -- DC-13 Ie 0.5A (110 Vdc) -- -- Rated insulation voltage Ui 250 Vac -- -- Minimum operating voltage per contract Umin -- Rated operational current 5 Vdc -- Rated impulse withstand voltage (1.2/50) Uimp 2.5 kV -- -- Rated conditional short-circuit current with 6A back-up fuse ISC 1 kA -- -- Max. admissible back-up fuse 4A gL -- -- 1 Mechanical Standard front dimension 45 mm 45 mm 45 mm 1 Device height 80 mm 80 mm 80 mm Mounting width 8.8 mm 17.6 mm 17.8 mm 1 Mounting On MCB IEC/EN 60715 top-hat rail IEC/EN 60715 top-hat rail 1 Degree of protection enclosed IP40 IP40 IP40 Terminal protection Protection against electric shock to IEC 536 Protection against electric shock to IEC 536 Protection against electric shock to IEC 536 1 Terminals Lift terminals Twin-purpose terminals Twin-purpose terminals Solid 0.5 - 2.5 mm2 1-2.5 mm2 2 x (1-2.5) mm2 Flexible 0.5 - 2.5 mm2 1-2.5 mm2 2 x (1-2.5) mm2 0.8 - 1.0 Nm (7-9 lb-in) 2.4 Nm (21 lb-in) 0.8 Nm (7 lb-in) 1 1 Terminal capacity Tightening torque of terminal screws 1 1 1 1 1 V4-T1-116 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com 1.3 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Dimensions 1 Approximate Dimensions in Inches (mm) 1 Miniature Circuit Breakers WMZS 1 0.22 (5.5) 1.20 (30.5) 1 0.18 (4.5) 1 1 3.15 (80.0) 3.15 (80.0) 3.15 (80.0) 1 1.77 (45.0) 1 0.69 (17.5) 1.38 (35.0) 1P 2P 2.07 (52.5) 1 2.36 (60.0) 3P Auxiliary Contacts WMZSAUX 1 0.43 (11.0) 1.73 (44.0) 1 1 Shunt Releases WMZSST 1 2.36 (60.0) 1.73 (44.0) 1 0.08 (2.0) 0.38 (9.6) 3.15 (80.0) 0.69 (17.6) 0.22 (5.5) 1.03 (26.2) 0.13 (3.4) 0.13 (3.4) 0.39 (10.0) 1.73 (44.0) 2.36 (60.0) 0.22 (5.5) 1 1 1 1 1 Undervoltage Releases WMZSUVR WMZSAUXTRIP 1 1 2.36 (60.0) 0.35 (9.0) 1 1 1.77 (45.0) 3.36 (85.4) 0.35 (8.9) 1.77 (45.0) 3.15 (80.0) 1.73 (44.0) 1 0.38 (9.6) 3.15 (80.0) 1 1.77 (45.0) 1 3.15 (80.0) 1 1.77 (45.0) 0.70 (17.8) 0.22 (5.5) 1.73 (44.0) 1 2.36 (60.0) 1 0.22 (5.5) 1 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com V4-T1-117 1.3 1 Miniature Circuit Breakers and Supplementary Protectors UL 1077 DIN Rail Supplementary Protectors Approximate Dimensions in Inches (mm) 1 Busbar and Accessory Weights and Dimensions 1 Catalog Number Unit Weight Lbs (kg) 1 WMZS1P57T 0.64 (0.29) 39.72 (1009.0) 0.59 (15.0) 0.59 (15.0) WMZS2P56T 1.41 (0.64) 39.02 (991.0) 0.87 (22.0) 1.46 (37.0) 1 WMZS3P57T 1.83 (0.83) 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) 1 WMZS1P37TAUX 0.57 (0.26) 38.78 (985.0) 0.59 (15.0) 0.59 (15.0) WMZS2P46TAUX 1.39 (0.63) 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) WMZS3P48TAUX 1.74 (0.79) 38.66 (982.0) 0.87 (22.0) 1.46 (37.0) WMZS1P57T25 0.79 (0.36) 39.72 (1009.0) 0.59 (15.0) 0.59 (15.0) 1 WMZS2P56T25 1.74 (0.79) 39.02 (991.0) 0.87 (22.0) 1.46 (37.0) 1 WMZS3P57T25 2.29 (1.04) 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) WMZS1P37T25AUX 0.68 (0.31) 38.78 (985.0) 0.59 (15.0) 0.59 (15.0) 1 WMZS2P46T25AUX 1.61 (0.73) 39.72 (1009.0) 0.87 (22.0) 1.46 (37.0) WMZS3P48T25AUX 2.14 (0.97) 38.66 (982.0) 0.87 (22.0) 1.46 (37.0) 1 WMZS35EXT 0.07 (0.03) 2.36 (60.0) 0.67 (17.0) 1.14 (29.0) 1 WMZSBCONA 0.07 (0.03) 1.57 (40.0) 0.71 (18.0) 1.18 (30.0) WMZSBBTC 0.007 (0.003) 3.35 (85.0) 0.47 (12.0) 0.94 (24.0) WMZS1CAP 0.002 (0.001) 0.55 (14.0) 0.20 (5.0) 0.39 (10.0) WMZS3CAP 0.002 (0.001) 0.94 (24.0) 0.87 (22.0) 0.39 (10.0) 1 1 Length Width Height 1 1 L W 1 1 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 1 1 1 1 1 1 1 1 1 1 1 1 1 V4-T1-118 Volume 4--Circuit Protection CA08100005E--March 2013 www.eaton.com L1 L2 H