https://www.phoenixcontact.com/us/products/2944245
10/31/2014Page1/4
Solid-state relay module-EMG 10-OV-110DC/24DC/1-2944245
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Power solid-state relay, with LED and protective circuit in input and output circuits, input: 110 V DC, output: 5 - 36
V DC/max. 1 A
The illustration shows version EMG
10-OV, with DC voltage output, max.
1 A
Product Features
RC protective circuit
Protective circuit in input and output
EMG-17-OV, short-circuit-proof with indicator LED
Electrical isolation
Direct control with switching levels from 5 V to 230 V and up to 2 A
Zero voltage switch
Status indicator
Key commercial data
Packing unit 1 pc
GTIN
Weight per Piece (excluding packing) 40.53 GRM
Custom tariff number 85364900
Country of origin Germany
Technical data
Dimensions
Width 10 mm
Height 75 mm
https://www.phoenixcontact.com/us/products/2944245
10/31/2014Page2/4
Solid-state relay module-EMG 10-OV-110DC/24DC/1-2944245
Technical data
Dimensions
Depth 102 mm
Ambient conditions
Ambient temperature (operation) -20 °C ... 50 °C
Ambient temperature (storage/transport) -20 °C ... 70 °C
Degree of protection IP20
Input data
Nominal input voltage UN110 V DC
Input voltage range in reference to UN0.9 ... 1.1
Switching threshold "0" signal in reference to UN≤ 0.23
Switching threshold "1" signal in reference to UN≥ 0.9
Typical input current at UN4 mA
Typical response time 0.1 ms
Typical turn-off time 0.2 ms
Status display Yellow LED
Type of protection Protection against polarity reversal
Protective circuit/component Polarity protection diode
Transmission frequency 500 Hz
Output data
Output nominal voltage 24 V DC
Output voltage range 5 V DC ... 36 V DC
Limiting continuous current 1 A (see derating curve)
Surge current 2 A (t = 1 s)
Peak offstate voltage 45 V DC (Collector-emitter reverse voltage)
Voltage drop at max. limiting continuous current ≤ 1 V
Output circuit 2-wire, floating
Type of protection Protection against polarity reversal
Protective circuit/component Polarity protection diode
Connection data
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
https://www.phoenixcontact.com/us/products/2944245
10/31/2014Page3/4
Solid-state relay module-EMG 10-OV-110DC/24DC/1-2944245
Technical data
Connection data
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
General
Test voltage input/output 3.5 kV AC
3.5 kV AC
Mounting position any
Assembly instructions In rows with zero spacing
Operating mode 100% operating factor
Inflammability class according to UL 94 V0
Standards/regulations IEC 60664
EN 50178
IEC 62103
Rated surge voltage / insulation Basic insulation
Classifications
eCl@ss
eCl@ss 4.0 27371102
eCl@ss 4.1 27371102
eCl@ss 5.0 27371001
eCl@ss 5.1 27371001
eCl@ss 6.0 27371001
eCl@ss 7.0 27371001
eCl@ss 8.0 27371001
ETIM
ETIM 2.0 EC001504
ETIM 3.0 EC001504
ETIM 4.0 EC001504
ETIM 5.0 EC001504
UNSPSC
UNSPSC 6.01 30211916
UNSPSC 7.0901 39121542
UNSPSC 11 39121542
UNSPSC 12.01 39121542
UNSPSC 13.2 39121542
https://www.phoenixcontact.com/us/products/2944245
10/31/2014Page4/4
Solid-state relay module-EMG 10-OV-110DC/24DC/1-2944245
Drawings
Diagram
Ambienttemperature[°C]
Loadcurrent[A]
30
20
1
2
1,5
40 50 60
Circuit diagram
ACDC
A1
+
A2
-
13
+
14
A1 13
+
A2
-
+
14
Phoenix Contact 2014 © - all rights reserved
http://www.phoenixcontact.com