https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input:3-phase, output: 48 VDC / 20 A Product Description QUINT POWER power supplies with maximum functionality QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur. Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC ... 56 V DC are covered. Your advantages Adjustable output voltage of 30 to 56 V DC Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently Fast tripping of standard circuit breakers with dynamic power reserve SFB (selective fuse breaking) technology with up to 6 times the nominal current for 12 ms Preventive function monitoring indicates critical operating states before errors occur Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356547734 Weight per Piece (excluding packing) 2,960.000 g Custom tariff number 85044030 Country of origin Thailand Technical data Dimensions 01/16/2021Page1/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Technical data Dimensions Width 96 mm Height 130 mm Depth 179 mm Width with alternative assembly 176 mm Height with alternative assembly 130 mm Depth with alternative assembly 99 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 C ... 70 C (> 60 C Derating: 2.5 %/K) Ambient temperature (start-up type tested) -40 C Ambient temperature (storage/transport) -40 C ... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height 4000 m Input data Nominal input voltage range 3x 400 VAC ... 500 VAC Input voltage range 3x 320 VAC ... 575 VAC 2x 360 VAC ... 575 VAC (Not approved by UL) 450 VDC ... 800 VDC AC frequency range 45 Hz ... 65 Hz Frequency range DC 0 Hz Discharge current to PE < 3.5 mA Current consumption 3x 2.1 A (400VAC) 3x 1.7 A (500 VAC) 1.7 A (600 VDC) Nominal power consumption 1386 VA Inrush current < 20 A (typical) Mains buffering time typ. 25 ms (400VAC) typ. 35 ms (500 VAC) Recommended breaker for input protection 6 A ... 16 A (AC: Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 48 VDC 1% Setting range of the output voltage (USet) 30 VDC ... 56 VDC (> 48VDC, constant capacity restricted) 01/16/2021Page2/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Technical data Output data Nominal output current (IN) 20 A (-25C...60C, UOUT = 48VDC) POWER BOOST (IBoost) 22.5 A (-25C...40C permanent, UOUT = 48VDC ) Selective Fuse Breaking (ISFB) 100 A (12 ms) Derating 60 C ... 70 C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback voltage resistance max. 60 VDC Protection against overvoltage at the output (OVP) < 60 VDC Active current limitation Approx. IBOOST = 22.5 A (for short-circuit) Control deviation < 1 % (change in load, static 10 % ... 90 %) < 4 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage 10 %) Residual ripple < 50 mVPP (with nominal values) Output power 960 W Typical response time <1s Maximum power dissipation in no-load condition 24 W Power loss nominal load max. 70 W General Net weight 2.5 kg Efficiency > 93 % (at 400 V AC and nominal values) MTBF (IEC 61709, SN 29500) > 890000 h (25C) > 509000 h (40C) Insulation voltage input/output 4 kV AC (type test) 2 kV AC (routine test) Insulation voltage input / PE 3.5 kV AC (type test) 2 kV AC (routine test) Insulation voltage output / PE 500 VDC (routine test) Degree of protection IP20 Protection class I Housing material Steel sheet, zinc-plated Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: PN 50%, 5mm horizontally, 15mm next to active components, 50mm vertically alignable: PN <50%, 0mm horizontally, 40mm vertically top, 20 mm vertically bottom Connection data, input Connection method Screw connection 01/16/2021Page3/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Technical data Connection data, input Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 6 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 4 mm Conductor cross section AWG min. 18 Conductor cross section AWG max. 10 Stripping length 7 mm Screw thread M3 Connection data, output Connection method Screw connection Conductor cross section solid min. 0.5 mm Conductor cross section solid max. 16 mm Conductor cross section flexible min. 0.5 mm Conductor cross section flexible max. 16 mm Conductor cross section AWG min. 8 Conductor cross section AWG max. 6 Stripping length 10 mm Screw thread M3 Connection data for signaling Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 6 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 4 mm Conductor cross section AWG min. 18 Conductor cross section AWG max. 10 Screw thread M3 Standards EMC requirements for noise immunity EN61000-6-1 EN61000-6-2 EMC requirements for noise emission EN61000-6-3 EN61000-6-4 Standard - Safety of transformers IEC 61558-2-17 Standard - Electrical safety IEC60950-1/VDE0805 (SELV) Standard - Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN50178/VDE0160 (PELV) 01/16/2021Page4/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Technical data Standards Standard - Safety extra-low voltage IEC60950-1 (SELV) and EN60204-1 (PELV) Standard - Safe isolation DINVDE0100-410 Standard - Protection against shock currents, basic requirements for protective separation in electrical equipment EN50178 Standard - Limitation of mains harmonic currents EN61000-3-2 Standard - Equipment safety BG (design tested) Standard - Approval for medical use IEC60601-1, 2xMOOP Rail applications EN50121-4 Conformance/approvals UL approvals UL Listed UL508 UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net) UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) CSA CAN/CSA-C22.2 No.60950-1-07 CSA-C22.2 No.107.1-01 EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Electrostatic discharge EN 61000-4-2 Contact discharge 8 kV (Test Level 4) Discharge in air 15 kV (Test Level 4) Electromagnetic HF field EN61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 20 V/m (Test Level 3) Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m (Test Level 3) Frequency range 2 GHz ... 3 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) EN61000-4-4 Input 4 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Signal 2 kV (Test Level 4 - asymmetrical) Comments Criterion A Surge voltage load (surge) EN61000-4-5 Input 2 kV (Test Level 3 - symmetrical) 6 kV (Test Level 4 - asymmetrical) 01/16/2021Page5/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Technical data EMC data Output 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 2 - asymmetrical) Comments Criterion A Conducted interference EN61000-4-6 I/O/S asymmetrical Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram L1 (+) L2 L3 (-) DC OK I < IN 13 14 Classifications eCl@ss eCl@ss 10.0.1 27040701 eCl@ss 11.0 27040701 eCl@ss 4.0 27040700 eCl@ss 4.1 27040700 eCl@ss 5.0 27242200 eCl@ss 5.1 27242200 eCl@ss 6.0 27049000 01/16/2021Page6/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Classifications eCl@ss eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 eCl@ss 9.0 27040701 ETIM ETIM 3.0 EC001039 ETIM 4.0 EC002540 ETIM 5.0 EC002540 ETIM 6.0 EC002540 ETIM 7.0 EC002540 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 UNSPSC 18.0 39121004 UNSPSC 19.0 39121004 UNSPSC 20.0 39121004 UNSPSC 21.0 39121004 Approvals Approvals Approvals CSA / UL Listed / UL Recognized / cUL Recognized / IECEE CB Scheme / cUL Listed / EAC / Type approved / EAC / cULus Recognized / cULus Listed Ex Approvals UL Listed / cUL Listed / cULus Listed Approval details CSA http://www.csagroup.org/services-industries/product-listing/ 2386029 01/16/2021Page7/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Approvals UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 IECEE CB Scheme http://www.iecee.org/ SI-2899 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 EAC EAC-Zulassung Type approved 005-006 EAC RU*DE*08.B.01873/19 cULus Recognized 01/16/2021Page8/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Approvals cULus Listed Accessories Accessories Assembly adapter Assembly adapters-UWA 182/52-2938235 Universal wall adapter for securely mounting the device in the event of strong vibrations. The device is screwed directly onto the mounting surface. The universal wall adapter is attached on the top/bottom. Device protection Type 3 surge protection device-PLT-SEC-T3-3S-230-FM-2905230 Plug-in device protection, according to type 3/class III, for 3-phase power supply networks with separate N and PE (5conductor system: L1, L2, L3, N, PE), with integrated surge-proof fuse and remote indication contact. Type 3 surge protection device-PLT-SEC-T3-60-FM-UT-2907917 Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage 60VAC/DC. Mounting rail adapter 01/16/2021Page9/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Accessories DIN rail adapter-UTA 107-2853983 Universal DIN rail adapter, for screwing on switchgear Redundancy module Diode-QUINT-DIODE/48DC/2X20/1X40-2320160 DIN rail diode module 48 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer. Redundancy module-TRIO-DIODE/48DC/2X10/1X20-2866527 Redundancy module with function monitoring, 48 V DC, 2x 10 A, 1x 20 A Thermomagnetic device circuit breakers Thermomagnetic device circuit breaker-CB TM1 1A SFB P-2800836 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Thermomagnetic device circuit breaker-CB TM1 2A SFB P-2800837 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. 01/16/2021Page10/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Accessories Thermomagnetic device circuit breaker-CB TM1 3A SFB P-2800838 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Thermomagnetic device circuit breaker-CB TM1 4A SFB P-2800839 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Thermomagnetic device circuit breaker-CB TM1 5A SFB P-2800840 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Thermomagnetic device circuit breaker-CB TM1 6A SFB P-2800841 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Thermomagnetic device circuit breaker-CB TM1 8A SFB P-2800842 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. 01/16/2021Page11/12 https://www.phoenixcontact.com/us/products/2320827 Power supply unit-QUINT-PS/3AC/48DC/20-2320827 Accessories Thermomagnetic device circuit breaker-CB TM1 10A SFB P-2800843 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 01/16/2021Page12/12