ACD-10 TRMS-PLUS
600A Clamp-On Multimeter
TRMS Measurement
AC & DC Voltage to 600V
AC Current to 600A
Thin Jaws, only 10mm (0.4”) thick
Resistance to 40M W
Continuity Buzzer
Capacitance to 3000 uF
Frequency measurement
In rush current
Hold & Maximum reading functions
Accommodates conductors up to 26mm (1.02”) in diameter
Auto ranging
Auto power off
Rubber over-molded case
Amprobe’s ACD-10 TRMS-PLUS meter offer thinner jaws over
standard clamp meters. Allowing access to tight measurement areas
and still accommodating conductors up to 25 mm. Both meters also
measure Capacitance and Frequency. Frequency is measured by ei-
ther jaws or test leads. Very versatile clamp multimeters. True RMS
version for noisy measurement environments for a more accurate
reading.
600V
Amprobe® Test Tools www.Amprobe.com
Data Sheet
Display: 3-3/4 digits 4000 counts LCD display
Update Rate: 3 per second nominal
Polarity: Automatic
Operating Temperature: 0 °C to 40 °C; < 80% RH for temperature up to 31 °C decreasing linearly to 50% RH at 40 °C
Altitude: Operating below 2000m; Indoor use
Storage Temperature: -20 °C to 60 °C, < 80% RH (with battery removed)
Temperature Coefficient: nominal 0.15 x (specified accuracy)/°C @(0 °C ~ 18 °C or 28 °C ~ 40 °C)
Low Battery: Below approx. 2.4V
Power Supply: 3V coin battery IEC-CR2032
Power Consumption: 2.8 mA typical except that 3.3 mA typical for ACA function
APO Timing: Idle for 30 minutes
APO Consumption: 5 μA typical
Dimension: 190 x 63 x 32 mm (7.4 x 2.5 x 1.3 in)
Weight: 139 gm approx
Jaw opening & Conductor diameter: max 26 mm
Special Features: 30ms Max Hold; Data Hold; Relative Zero mode
Safety: Meets EN61010-2-032, UL61010B-2-032, IEC61010-1 2nd Ed., EN61010-1
2nd Ed., UL61010-1 2nd Ed. CAT III-600 Volts ac & dc; Pollution degree : 2
EMC: Conforms to EN61326-1.
This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility)
and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in
the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that
may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results
when making measurements in the presence of electronic interference.
General Specifications
ACD-10 TRMS-PLUS 600A Clamp-On Multimeter
DC Voltage
400.0 mV ±( 0.3% + 4 digits)
4.000, 40.00, 400.0 V ±( 0.5% + 3 digits)
600 V ±( 1.0% + 4 digits)
NMRR: >50 dB @ 50/60Hz
CMRR: >120 dB @ DC, 50/60 Hz, Rs=1 kW
Input Impedance: 10 MW, 30 pF nominal (1000 MW for 400.0 mV range)
Transient protection: 6.5 kV (1.2/50 μs surge)
AC Voltage (50Hz ~ 500Hz)
4.000, 40.00, 400.0 V ±( 1.5% + 5 digits)
600 V ±( 2.0% + 5 digits)
CMRR: >60dB @ DC to 60 Hz, Rs=1 kW
Maximum Crest Factor: < 1.75 : 1 at full scale & < 3.5 : 1 at half scale limited to
fundamental and harmonics, that fall within the meter
specified AC bandwidth for non-sinusoidal waveforms
Input Impedance: 10 MW, 30 pF nominal
Transient protection: 6.5 kV (1.2/50μs surge)
ACD-10 TRMS Plus: True RMS sensing - 5 % to 100 % of range
Electrical Specification Accuracy (23 °C ± 5 °C & < 75% R.H.)
Function Range Accuracy
www.Amprobe.com
Data Sheet
Electrical Specification Accuracy (23 °C ± 5 °C & < 75% R.H.), cont.
ACD-10 TRMS-PLUS 600A Clamp-On Multimeter
Function Range Accuracy
AC Current (Clamp-on 50Hz / 60Hz)
Range Accuracy 1) 2) 3)
40.00, 400.0, 600 A ±( 1.5% + 8 digits)
Overload Protections: ACA Clamp-on jaws : 600 A rms continuous
ACD-10 TRMS Plus: True RMS sensing - 10 % to 100 % of range
1) Max Induced error from adjacent current carrying conductor: 0.05 A
2) Specified accuracy is from 1% to 100% of range and for measurements made at the jaw center. When the conductor is not posi-
tioned at the jaw center, position errors introduced are: Add 2% to specified accuracy for measurements made BEYOND jaw marking
lines (toward jaw opening)
3) Add 8 digits to specified accuracy @ reading < 10% of range
Resistance
400.0 W ±( 0.8% + 8 digits)
4.000, 40.00, 400.0 kW ±( 0.6% + 4 digits)
4.000 MW ±( 1.0% + 4 digits)
40.00 MW ±( 2.0% + 4 digits)
Open Circuit Voltage : 0.4 VDC typical
Transient protection : 6.5 kV (1.2/50μs surge)
Frequency
Function Sensitivity (Sine RMS) Range Accuracy
400.0 mVac 350mV 1 0 Hz ~ 2 kHz ±( 0.5%+4 digits)
4.000 Vac 1V 5 Hz ~ 5 kHz ±( 0.5%+4 digits)
4.000, 40.00 Vac 32V 5 Hz ~ 100 kHz ±( 0.5%+4 digits)
400.0 Vac 90V 5 Hz ~ 10 kHz ±( 0.5%+4 digits)
600 Vac 500V 5 Hz ~ 5 kHz ±( 0.5%+4 digits)
400.0 Aac 60A 40 Hz ~ 400 Hz ±( 0.5%+4 digits)
Display counts: 5000
Resolution: 0.001Hz
Overload Protection : ACA Clamp-on jaws : AC 600A rms continuous
Transient protection : VAC input jacks : 6.5kV (1.2/50μs surge)
Capacitance
Range 1) Accuracy 2) 3)
500.0nF, 5.000μF, ±( 3.5% + 6 digits)
50.0F, 500.0μF, 3000μF
1) Additional 50.00nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8V (approximately half full battery).
Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V
Transient protection: 6.5 kV (1.2/50 μs surge)
Audible Continuity Tester
Audible indication: between 10 W and 120 W.
Transient protection: 6.5 kV (1.2/50 μs surge)
Diode Tester / Open Circuit Voltage Test Current
(Typical) < 1.6 VDC @ 0.25 mA
Transient protection: 6.5 kV (1.2/50 μs surge)
Max Hold* (where applicable)
Specified accuracy ± 50 digits for changes > 25 ms in duration
www.Amprobe.comwww.Amprobe.com
Amprobe® Test Tools
Data Sheet
Amprobe® Test Tools
website: www.Amprobe.com
email: info@amprobe.com
Everett, WA 98203
Tel: 877-AMPROBE
Amprobe® Test Tools Europe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
©2007 Amprobe Test Tools. All rights reserved.
9/2007 3128780 Rev A
ACD-10 TRMS-PLUS 600A Clamp-On Multimeter
Included Accessories
Test leads, battery installed, soft carrying
pouch, and users manual