Please contact us about TUV certified products. AQ8 SIL type SSR with 9mm thickness controls up to 3A AQ8 RELAYS FEATURES RoHS compliant 1. Slim with 9 mm .354 inch thickness The thin type (45 mm long x 24 mm high x 9 mm wide) (1.772x.945x.354 inch) permits high density mounting. 2. Excellent in noise resistance Since the input and output are insulated by the phototriac coupler, the noise on the output side is not fed back to the input side. 3. Snubber circuit integrated The snubber circuit is integrated to prevent malfunction caused by the rapid rise of the voltage on the output side, such as inductive load and noise. 4. Zero-cross and random types are available. The zero-cross type generates minimal noise by suppressing occurrence of radio frequency interference (RFI) and electromagnetic interference (EMI). The random type features a short operation time which permits phase control. 5. High dielectric strength: 3,000 V AC (between input and output) 6. Two kinds of terminals distance are available. (5.08 mm and 7.62 mm) (.200 and .300 inch) 7. High reliability, long life and maintenance-free TYPICAL APPLICATIONS 1. Most suitable as drivers for small size AC motors, solenoids, solenoid valves and so on. 2. Copying equipment 3. Air conditioners 4. Industrial equipment such as NC machines, sequencers, robots, etc. ORDERING INFORMATION AQ Load current 2A 3A Load voltage 1: 75 to 125 V AC 2: 75 to 250 V AC Input terminal distance C1: 5.08 mm .200 inch C2: 7.62 mm .300 inch Type ZT: Zero-cross type T: Random type Input voltage 5, 12, 24 V DC ASCTB213E 201201-T1 Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ AQ8 TYPES Types Load current Load voltage Input voltage 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 75 to 125V AC 2A 75 to 250V AC Zero-cross type 75 to 125V AC 3A 75 to 250V AC 75 to 125V AC 2A 75 to 250V AC Random type 75 to 125V AC 3A 75 to 250V AC Input terminals distance (5.08 mm .200 inch type) Part No. AQ2A1-C1-ZT5V DC AQ2A1-C1-ZT12V DC AQ2A1-C1-ZT24V DC AQ2A2-C1-ZT5V DC AQ2A2-C1-ZT12V DC AQ2A2-C1-ZT24V DC AQ3A1-C1-ZT5V DC AQ3A1-C1-ZT12V DC AQ3A1-C1-ZT24V DC AQ3A2-C1-ZT5V DC AQ3A2-C1-ZT12V DC AQ3A2-C1-ZT24V DC AQ2A1-C1-T5V DC AQ2A1-C1-T12V DC AQ2A1-C1-T24V DC AQ2A2-C1-T5V DC AQ2A2-C1-T12V DC AQ2A2-C1-T24V DC AQ3A1-C1-T5V DC AQ3A1-C1-T12V DC AQ3A1-C1-T24V DC AQ3A2-C1-T5V DC AQ3A2-C1-T12V DC AQ3A2-C1-T24V DC Input terminals distance (7.62 mm .300 inch type) Part No. AQ2A1-C2-ZT5V DC AQ2A1-C2-ZT12V DC AQ2A1-C2-ZT24V DC AQ2A2-C2-ZT5V DC AQ2A2-C2-ZT12V DC AQ2A2-C2-ZT24V DC AQ3A1-C2-ZT5V DC AQ3A1-C2-ZT12V DC AQ3A1-C2-ZT24V DC AQ3A2-C2-ZT5V DC AQ3A2-C2-ZT12V DC AQ3A2-C2-ZT24V DC AQ2A1-C2-T5V DC AQ2A1-C2-T12V DC AQ2A1-C2-T24V DC AQ2A2-C2-T5V DC AQ2A2-C2-T12V DC AQ2A2-C2-T24V DC AQ3A1-C2-T5V DC AQ3A1-C2-T12V DC AQ3A1-C2-T24V DC AQ3A2-C2-T5V DC AQ3A2-C2-T12V DC AQ3A2-C2-T24V DC Standard packing: Carton 20 pcs., Case 200 pcs. RATING 1. Rating (Ambient temperature: 20C, 68F; Voltage ripple on the input side: 1% or less) 1) Zero-cross type * 2 A type Part No. Item Control voltage Input side Input impedance Drop-out voltage AQ2A1-C1ZT5VDC AQ2A1-C2ZT5VDC AQ2A1-C1ZT12VDC AQ2A1-C2ZT12VDC 5 V DC 12 V DC (4 to 6V) (9.6 to 14.4V) Approx. 0.18 k Approx. 0.55 k Min. 0.5 V Min. 1.2 V AQ2A1-C1ZT24VDC AQ2A1-C2ZT24VDC 24 V DC (21.6 to 26.4V) Approx. 1.4 k Min. 2.4 V Max. load current Load side Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current AQ2A2-C1ZT5VDC AQ2A2-C2ZT5VDC AQ2A2-C1ZT12VDC AQ2A2-C2ZT12VDC 5 V DC 12 V DC (4 to 6V) (9.6 to 14.4V) Approx. 0.18 k Approx. 0.55 k Min. 0.5 V Min. 1.2 V AQ2A2-C1ZT24VDC AQ2A2-C2ZT24VDC 24 V DC (21.6 to 26.4V) Approx. 1.4 k Min. 2.4 V *1 At ambient temperature of 30C or less 2 A*2 75 to 125 V AC Remarks 75 to 250 V AC 45 to 65 Hz 400 V 600 V In one cycle at 60 Hz 30 A*3 2.5 mA (100 V applied) OFF state dV/dt Panasonic Corporation 5 mA (200 V applied) 1.6 V at 60 Hz at max. carrying current 50 mA*4 25 mA*4 At ambient temperature of 80C 50 V/s Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB213E 201201-T1 AQ8 * 3 A type Part No. Item Control voltage Input side Input impedance Drop-out voltage AQ3A1-C1ZT5VDC AQ3A1-C2ZT5VDC AQ3A1-C1ZT12VDC AQ3A1-C2ZT12VDC 5 V DC 12 V DC (4 to 6V) (9.6 to 14.4V) Approx. 0.18 k Approx. 0.55 k Min. 0.5 V Min. 1.2 V AQ3A1-C1ZT24VDC AQ3A1-C2ZT24VDC 24 V DC (21.6 to 26.4V) Approx. 1.4 k Min. 2.4 V Max. load current Load side AQ3A2-C1ZT12VDC AQ3A2-C2ZT12VDC 5 V DC 12 V DC (4 to 6V) (9.6 to 14.4V) Approx. 0.18 k Approx. 0.55 k Min. 0.5 V Min. 1.2 V AQ3A2-C1ZT24VDC AQ3A2-C2ZT24VDC 24 V DC (21.6 to 26.4V) Approx. 1.4 k Min. 2.4 V Remarks *1 At ambient temperature of 30C or less 3 A*2 Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V In one cycle at 60 Hz 80 A*3 2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz 1.6 V at max. carrying current 50 mA* 25 mA* 4 4 OFF state dV/dt Notes: *1. *2. *3. *4. AQ3A2-C1ZT5VDC AQ3A2-C2ZT5VDC At ambient temperature of 80C 50 V/s Refer to REFERENCE DATA "3. Characteristics of input current vs. input voltage". Refer to REFERENCE DATA "1. Characteristics of load current vs. ambient temperature". Refer to REFERENCE DATA "2. Characteristics of non-repetitive surge current vs. carrying time". When the load current is less than the rated minimum load current, please refer to "Cautions for Use of SSR". 2) Random type * 2 A type Part No. Item Control voltage Input side Input impedance Drop-out voltage AQ2A1-C1T5VDC AQ2A1-C2T5VDC AQ2A1-C1T12VDC AQ2A1-C2T12VDC AQ2A1-C1T24VDC AQ2A1-C2T24VDC AQ2A2-C1T5VDC AQ2A2-C2T5VDC AQ2A2-C1T12VDC AQ2A2-C2T12VDC AQ2A2-C1T24VDC AQ2A2-C2T24VDC 5 V DC (4 to 6V) Approx. 0.3 k Min. 0.5 V 12 V DC (9.6 to 14.4V) Approx. 0.8 k Min. 1.2 V 24 V DC (21.6 to 26.4V) Approx. 1.8 k Min. 2.4 V 5 V DC (4 to 6V) Approx. 0.3 k Min. 0.5 V 12 V DC (9.6 to 14.4V) Approx. 0.8 k Min. 1.2 V 24 V DC (21.6 to 26.4V) Approx. 1.8 k Min. 2.4 V Max. load current Load side Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current 75 to 250 V AC 45 to 65 Hz 400 V 600 V In one cycle at 60 Hz 30 A*3 2.5 mA (100 V applied) 5 mA (200 V applied) 1.6 V at max. carrying current 4 50 V/s Panasonic Corporation at 60 Hz 50 mA* 25 mA* 4 OFF state dV/dt ASCTB213E 201201-T1 *1 At ambient temperature of 30C or less 2 A*2 75 to 125 V AC Remarks Automation Controls Business Unit At ambient temperature of 80C industrial.panasonic.com/ac/e/ AQ8 * 3 A type Part No. AQ3A1-C1T5VDC AQ3A1-C2T5VDC AQ3A1-C1T12VDC AQ3A1-C2T12VDC AQ3A1-C1T24VDC AQ3A1-C2T24VDC AQ3A2-C1T5VDC AQ3A2-C2T5VDC AQ3A2-C1T12VDC AQ3A2-C2T12VDC AQ3A2-C1T24VDC AQ3A2-C2T24VDC 5 V DC (4 to 6V) Approx. 0.3 k Min. 0.5 V 12 V DC (9.6 to 14.4V) Approx. 0.8 k Min. 1.2 V 24 V DC (21.6 to 26.4V) Approx. 1.8 k Min. 2.4 V 5 V DC (4 to 6V) Approx. 0.3 k Min. 0.5 V 12 V DC (9.6 to 14.4V) Approx. 0.8 k Min. 1.2 V 24 V DC (21.6 to 26.4V) Approx. 1.8 k Min. 2.4 V Item Control voltage Input side Input impedance Drop-out voltage Max. load current Load side 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V In one cycle at 60 Hz 80 A*3 2.5 mA (100 V applied) 5 mA (200 V applied) at 60 Hz 1.6 V at max. carrying current 50 mA* 25 mA* 4 4 OFF state dV/dt Notes: *1. *2. *3. *4. *1 At ambient temperature of 30C or less 3 A*2 Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current Remarks At ambient temperature of 80C 50 V/s Refer to REFERENCE DATA "3. Characteristics of input current vs. input voltage". Refer to REFERENCE DATA "1. Characteristics of load current vs. ambient temperature". Refer to REFERENCE DATA "2. characteristics of non-repetitive surge current vs. carrying time". When the load current is less than the rated minimum load current, please refer to "Cautions for Use of SSR". 2. Characteristics (Ambient temperature: 20C 68F; Input voltage ripple: 1% or less) Type Item Operate time, max. Release time, max. Insulation resistance, min. Breakdown voltage Vibration resistance Destructive Functional Destructive Functional Ambient temperature Storage temperature Operational method Shock resistance Zero-cross type Random type 1/2 cycle of voltage sine wave + 1 ms 1/2 cycle of voltage sine wave + 1 ms 109 between input and output 3,000 V AC between input and output Remarks 1 ms at 500 V DC For 1 minute 10 to 55 Hz at double amplitude of 3 mm 10 to 55 Hz at double amplitude of 3 mm Min. 980 m/s2 {100 G} Min. 980 m/s2 {100 G} -30C to +80C -22F to +176F -30C to +100C -22F to +212F Zero-cross (Turn ON and Turn OFF) Random turn ON, zero-cross turn OFF 1 hour for X, Y, Z axis 10 min. for X, Y, Z axis 5 times each for X, Y, Z axis 4 times each for X, Y, Z axis 1. Characteristics of load current vs. ambient temperature 2.-(1) Characteristics of non-repetitive surge current vs. carrying time 2.-(2) Characteristics of non-repetitive surge current vs. carrying time Use load current within range specified in the figure below. (2 A type) (3 A type) Non-repetitive surge current, A Non-repetitive surge current, A REFERENCE DATA 3.0 Load current, A 3 A type 2.5 2 A type 2.0 1.5 1.0 80 60 40 20 0.5 0 -30 100 0 20 40 60 80 Ambient temperature, C Panasonic Corporation 0 100 80 60 40 20 5 10 50 No. of cycles at 60 Hz Automation Controls Business Unit 100 0 industrial.panasonic.com/ac/e/ 5 10 50 No. of cycles at 60 Hz 100 ASCTB213E 201201-T1 AQ8 3. Characteristics of input current vs. input voltage 4.-(1) Characteristics of load current vs. ambient temperature for adjacent mounting 4.-(2) Characteristics of load current vs. ambient temperature for adjacent mounting --zero-cross type ---Random type (2 A type) Conditions: Natural cooling (3 A type) Conditions: Natural cooling 30 2.5 Load current, A Input current, mA 20 15 10 =20.32 mm .800 inch =12.7 mm .500 inch =9.0 mm .354 inch 2.0 (12 V type) (24 V type) 1.5 1.0 Load current, A 3.0 25 =20.32 mm .800 inch =12.7 mm .500 inch =9.0 mm .354 inch 2.0 1.0 (5 V type) 0.5 5 =Adjacent mounting pitch 0 0 10 0 -30 20 30 Input voltage, V DIMENSIONS (mm inch) 0 The CAD data of the products with a (Common for zero-cross and random types) 1. Input terminals distance 5.08 mm .200 inch 1) 2 A type =Adjacent mounting pitch 0 -30 20 40 60 80 Ambient temperature, C CAD Data Mounting hole location (Bottom view) 9 max. .354 45 max. 1.772 20 40 60 80 Ambient temperature, C mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions CAD Data 0 27.94 1.100 Terminal 4 3 Copper foil 2 1 4-1.2 dia. 4-.047 dia. 2.54x 2 .100x 2 24 max. .945 - 4INPUT3 + 5.08 .200 4 5.08 .200 10.16 .400 12.7 .500 3 2 2.54x 4 .100x 4 Tolerance: 0.1 .004 2 LOAD 1 8 min. .315 2.5 .098 2.54x 5 .100x 5 Schematic 4-0.8 dia. 4-.031 INPUT 4 3 LOAD 2 1 1 General tolerance: 0.5 .020 - + Load Input Load power source power source 2) 3 A type External dimensions CAD Data Mounting hole location (Bottom view) 9 max. .354 43 max. 1.693 27.94 1.100 Terminal 4 3 Copper foil 2 1 4-1.2 dia. 4-.047 dia. 2.54x 5 .100x 5 2.54x 2 .100x 2 32 max. 1.259 - 4INPUT3 + 2.54x 4 .100x 4 Tolerance: 0.1 .004 Schematic 2 LOAD 1 8 min. .315 2.5 .098 5.08 .200 4 12.7 .500 3 5.08 .200 10.16 .400 2 4-0.8 dia. 4-.031 1 General tolerance: 0.5 .020 ASCTB213E 201201-T1 Panasonic Corporation Automation Controls Business Unit INPUT 4 3 LOAD 2 1 - + Load Input Load power source power source industrial.panasonic.com/ac/e/ AQ8 2. Input terminals distance 7.62 mm .300 inch 1) 2A type External dimensions Mounting hole location (Bottom view) CAD Data 9 max. .354 45 max. 1.772 30.48 1.200 Terminal 4 3 Copper foil 2 1 4-1.2 dia. 4-.047 dia. 24 max. .945 - 4INPUT 3+ 2.54x 3 .100x 3 7.62 .300 4 5.08 .200 10.16 .400 12.7 .500 3 2 2.54x 4 .100x 4 Tolerance: 0.1 .004 2 LOAD 1 8 min. .315 2.5 .098 2.54x 5 .100x 5 Schematic 4-0.8 dia. 4-.031 INPUT 4 3 LOAD 2 1 1 General tolerance: 0.5 .020 - + Load Input Load power source power source 2) 3A type External dimensions CAD Data Mounting hole location (Bottom view) 9 max. .354 43 max. 1.693 30.48 1.200 Terminal 4 3 Copper foil 2 1 4-1.2 dia. 4-.047 dia. 2.54x 5 .100x 5 2.54x 3 .100x 3 32 max. 1.259 - 4 INPUT3+ 2.54x 4 .100x 4 Tolerance: 0.1 .004 Schematic 2 LOAD 1 8 min. .315 2.5 .098 7.62 .300 4 3 12.7 .500 5.08 .200 10.16 .400 2 4-0.8 dia. 4-.031 1 General tolerance: 0.5 .020 Panasonic Corporation Automation Controls Business Unit INPUT 4 3 LOAD 2 1 - + Load Input Load power source power source industrial.panasonic.com/ac/e/ ASCTB213E 201201-T1 AQ8 NOTE 1. When used for the load less than rated In case of the load current less than rated, malfunction may result from the residual voltage across the both ends of the load even if the solid state relay is turned off. Use a dummy resistor as a countermeasure. The total of the current through the resistor and the load current must exceed the min. rated load current. R0 Dummy resistor SSR 1 * Characteristics of residual voltage vs. load impedance 100 80 f = 60Hz Ve: Residual voltage V: Power voltage 1 60 Ve x 100 V (%) 40 Load SSR 2 V Ve Power factor: 1 (resistor load) Power factor: 0.4 (induction load) 20 Load 0 Load power source 2 In case the dummy resistor is not used, keep in mind that the residual voltage becomes as follows: Example: For the inductive load by the 20 mA load current and the 200 V AC load voltage, the load impedance becomes 10 k and Ve/V = 14% is estimated from the right above graph. Accordingly, the 28 V voltage remains across the both ends of the load when the solid state relay is turned off. 10 30 20 40 50 Load impedance (k) 2. when the terminal is bent Care shall be taken neither to apply mechanical stresses to the mold area of the solid state relay nor to bend the terminal 45 degrees or more. Max. 45 Solid state relay Printed circuit board Solder Recommended Temperature Controllers Our temperature controller is recommended for use with our Solid State Relays. 48mm 1.890inch 56mm 2.205inch Features * Space saving requiring only a depth of 65 mm * Data collection possible through a PLC using RS485 communication * Tool port is standard for easy data setting * Inverted LCD + backlight for good legibility with large characters * Excellent operability and rich optional control functions Substitute part numbers 48mm 1.890inch Power supply 100 to 240 V AC Control output Non-contact voltage output Part No. AKT4H112100 * For detailed product information about temperature controllers, please refer to our website: http://industrial.panasonic.com/ac/e/ For Cautions for Use. ASCTB213E 201201-T1 Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: AQ2A2-C1-ZT12VDC AQ2A2-C1-T5VDC AQ2A2-C1-T24VDC