MM5452, MM5453
SNLS367C –FEBRUARY 1995–REVISED MARCH 2013
www.ti.com
Absolute Maximum Ratings (1)(2)
Voltage at Any Pin, Referenced to Gnd -0.3V to +10V
Storage Temperature -65°C to +150°C
Power Dissipation at 25°C 350mW
Power Dissipation at 70°C 300mW
Junction Temperature +150°C
Lead Temperature (Soldering, 10s) 300°C
(1) “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be ensured. They are not meant to imply
that the devices should be operated at these limits. The table of “Electrical Characteristics” specifies conditions of device operation.
(2) If Military/Aerospace specified devices are required, please contact the TI Sales Office/Distributors for availability and specifications.
Recommended Operating Conditions
VDD 3V to 10V
Operating Temperature −40°C to 85°C
Electrical Characteristics
TAwithin operating range, VDD = 3.0V to 10V, VSS = 0V unless otherwise specified.
Parameter Conditions Min Typ Max Units
Supply Voltage, VDD 3 10 V
Average Supply Current, IDD All Outputs Open, Clock=Gnd,
Data=Gnd,OSC=Gnd, BP_IN @ 32Hz
VDD= 5V 10 µA
VDD= 10V 40 µA
Input Logical '0' Voltage, VIL VDD= 3V 0.4 V
VDD= 5V 0.8 V
VDD= 10V 0.8 V
Input Logical '1' Voltage, VIH VDD= 3V 2.0 V
VDD= 5V 2.0 V
VDD= 10V 8.0 V
Segment Sink Current, IOL VDD= 3V, VOUT= 0.3V -20 -40 µA
Segment Source Current, IOH VDD= 3V, VOUT= 2.7V 20 40 µA
Backplane Out Sink Current, IOL VDD= 3V, VOUT= 0.3V -320 -500 µA
Backplane Out Source Current, VDD= 3V, VOUT= 2.7V 320 500 µA
IOH
Segment Output Offset Voltage Segment Load = 250pF (1) +/-50 mV
Backplane Output Offset Voltage Backplane Load = 8750pF (1) +/-50 mV
Backplane Out Frequency ROSC_IN= 50kΩ, COSC_IN= 0.01µF 75 Hz
Clock Input Frequency, fCLOCK(2) VDD= 3V (1) (3) 500 kHz
VDD= 5V (1) 750 kHz
VDD= 10V (1) 1.0 MHz
Clock Input Duty Cycle(2) 40 60 %
Data Input Set-Up Time, tDS 300 ns
Data Input Hold Time, tDH 300 ns
DataEnable Set-up Time, tDES 100 ns
(1) This parameter is ensured (but not production tested) over the operating temperature range and the operating supply voltage range. Not
to be used in Q.A. testing.
(2) Clock input rise time (tr) and fall time (tf) must not exceed 300ns
(3) AC input waveform for test purposes: tr≤20ns, tf≤20ns, fCLOCK= 500kHz, Duty Cycle = 50% ±10%
2Submit Documentation Feedback Copyright © 1995–2013, Texas Instruments Incorporated
Product Folder Links: MM5452 MM5453