Model TJE Precision Gage/Absolute Pressure Transducer DESCRIPTION Model TJE pressure transducers are all-welded stainless steel The gage Model TJE is a strain gage based transducer and sensors built for rugged industrial applications that require high features a unique "true gage" design which utilizes a second accuracy and measurement stability. The Model TJE is available welded stainless steel diaphragm that hermetically seals the with a variety of options for extended temperature operation, strain gage circuitry from atmospheric contamination. This electrical terminations and high-level outputs including 5 Vdc or design references the primary pressure sensing diaphragm to 10 Vdc and 4 mA to 20 mA. Most high-level output models have the atmosphere, and provides a stable zero regardless of the internal shunt calibration circuits as a standard feature to allow transducer environment. easy set-up of the sensor to the data system. An optional internal signature calibration chip provides calibration information for automatic set up with the Model SC four-or-twelve channel digital indicator. FEATURES * 0.1 % accuracy * 0.0025 % F.S./F temperature effect * 1 psig/a to 60000 psig/a range * mV/V, 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc to 10 Vdc output * All-welded, stainless steel construction * Intrinsically safe available (2N option only)18 * CE19 The absolute Model TJE has an all-welded vacuum reference chamber assuring long-term stability. Model TJE PERFORMANCE SPECIFICATIONS Characteristic Measure Accuracy 0.10 % full scale Linearity 0.10 % full scale Hysteresis 0.05 % full scale Media All gases/liquids compatible with wetted parts Resolution Infinite Calibration 5-point calibration: 0 %, 50 %, and 100 % of full scale 1 MOUNTING DIAGRAM AND CHARACTERISTICS ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero 0.0025 % full scale/F Temperature effect, span 0.0025 % reading/F Sealing Hermetically sealed IP68/NEMA 6P For reference only TYPICAL SYSTEM DIAGRAM ELECTRICAL SPECIFICATIONS Characteristic Measure Strain gage type Bonded foil Insulation resistance 5000 mOhm @ 50 Vdc Bridge resistance 350 ohm Shunt calibration data Included Electrical termination (std) PTIH-10-6P or equiv. (hermetic stainless) Mating connector (not incl) PT06A-10-6S or equiv. (AA111) MECHANICAL SPECIFICATIONS Characteristic Measure Wetted parts material number here < 2000 psig/a 17-4 PH stainless steel > 2000 psig/a 15-5 PH stainless steel Weight 10 oz Case material 304 stainless steel Marking Permanent metal name plate MILSTD130F 4.3; Individual sequential serial number per sensor; Country of origin and date of manufacture 2 Honeywell * Sensing and Control Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Precision Gage/Absolute Pressure Transducer RANGE CODES Pressure range (psi) 1 RANGE CODE AP 2 5 10 15 25 50 75 100 150 200 300 500 750 1000 1500 AR AT AV BJ BL BN BP BR CJ CL CP CR CT CV DJ 3k 3.5 k 4k D mm [in] psia 57 [2.25] 38 [1.50] D mm [in] psig 57 [2.25] 45 [1.75] L mm [in] psia 65 [2.54] 60 [2.35] L* mm [in] psia 96 [3.79] 91 [3.60] L mm [in] psig 46 [1.81] 51 [2.00] 51 [2.02] L* mm [in] psig 78 [3.06] 83 [3.25] 83 [3.27] 38 [1.50] Over pressure 150 % full scale (test) (psi) 150 % full scale Over pressure 50 (burst) (psi) 100 Port volume cm3 [in3] 4,1 [0.25] Natural frequency (Hz) Pressure range (psi) 5,2 [0.32] 500 550 1000 200 1.3 k 2.1 k 400 2k 2,8 [0.17] 2.5 k 2.9 k 3.5 k 2000 3000 5000 7500 10000 DL DN DR DT DV RANGE CODE 800 4.6 k 6k 7k 60000 EJ EL EN EP ES 48 [1.90] 56 [2.21] L* mm [in] psia 80 [3.15] 89 [3.46] Over pressure (test) (psi) 150 % full scale Consult factory Over pressure (burst) (psi) 8k Port volume cm3 [in3] 3,1 [0.12] Natural 35 k frequency (Hz) 20 k 50000 L mm [in] psia 25 k 17 k 30000 D mm [in] psia 25 k 12 k 20000 38 [1.50] 20 k 9.5 k 15000 38 [1.50] 12 k 9k 40 k 45 k 60 k 80 k 80 k >100 k >100 k >100 k >100 k 1,5 [0.06] 40 k 54 k 60 k 80 k 100 k * Length of pressure transducer with amplified option (see option codes) ** 0.5 psi is available for gage only Honeywell * Sensing and Control 3 Model TJE OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell. com/TMsensor-ship for updated listings. Pressure ranges 1, 2, 5, 10, 15, 25, 50, 75, 100, 150, 200 300, 750, 1500, 2000, 15000, 20000, 30000, 50000, 60000 psig/a 500, 1000, 3000, 5000, 7500, 10000 psia 500, 1000, 3000, 5000, 7500, 10000 psig 1a. 60 F to 160 F Temperature compensation 1b. 30 F to 130 F 1f. 70 F to 250 F 11 1g. 70 F to 325 F 11 1h. 70 F to 400 F 11 1i. -65 F to 250 F 11 Internal amplifiers 10 2n. 4 mA to 20 mA (two wire) intrinsically safe8, 17 2t. 0 Vdc to 10 Vdc output 2u. Unamp., mV/V output 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 2a. 0 Vdc to 5 Vdc (four wire) output15 2c. 0-5 Vdc output15 2j. 4 mA to 20 mA (three wire) output 2k. 4 mA to 20 mA (two wire) output8, 17 Internal ampli- 3a. Input/output isolation15 3d. Remote buffered shunt calibration fier enhancements Pressure ports9 5a. 1/4-18 NPT female (3000 psig to 10000 psig) 5b. 1/4-18 NPT male (15 psig/a to 10000 psig/a) 5c. 7/16-20 UNF female (per MS33649-4) 5d. 7/16-20 UNF male 5g. G 1/4 male Electrical termination 6a. Bendix PTIH-10-6P (or equiv), 6 pin (max 250 F) 6b. MS type connector to mate with MS3106-14S 6S (max 160 F)13 6e. Integral cable: Teflon (0 F to 180 F) 6f. Integral cable: PVC (-20 F to 160 F) 6g. Integral cable: Neoprene (0 F to 180 F) 6h. Integral cable: Silicone (-65 F to 300 F) 6i. Integral underwater cable (max 180 F) 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable Shunt calibration 8a. Precision internal resistor11 Special calibration9 9a. 10 point (5 up/5 down) 20 % increments @ 70 F (gage) 9b. 20 point (10 up/10 down) 10 % increments @ 70 F (gage) Wetted diaphragm9 10a. 316 stainless steel9 10b. Crucible A-286 Bridge resistance9 12a. 1000 ohm (foil) (max 400 F) 12b. 5000 ohm (foil) (max 400 F) Zero and span 14a. No access to pots 14b. Top access to pots adjustment Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration11 53t. TEDS IEEE1451.4 module16 4 Honeywell * Sensing and Control 10c. Hastelloy-C 10d. Monel K-500 6m. DIN 43650 6q. Molded integral cable: Polyurethane (max 180 F) 6t. Integral cable with Heyco spring strain relief (5 ft) Precision Gage/Absolute Pressure Transducer iNTERNAL AMPLIFIERS Amplifier specifications mV/V output standard Voltage output: Option 2a4 Vehicle voltage output: Option 2c4 Vehicle voltage Current output: Option three-wire: 2t4 Option 2j4 Current twowire: Option 2k4 Intrinsically safe amp: Option 2N (2n) Output signal 3 mV/V 2 0 Vdc to 5 Vdc 0-5 Vdc or 5 Vdc @ 5 mA 0-10 Vdc or 10 Vdc @ 5 mA 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA Input power (voltage) 10 Vdc regulated 15 Vdc or 26-32 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc3 9 Vdc to 32 Vdc3 9 Vdc to 28 Vdc3 Input power (current) 28.5 mA @ 10 Vdc 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA Freq. resp (amp) Natural frequency 2000 Hz 3000 Hz 3000 Hz 2500 Hz 2500 Hz 2000 Hz Power supply rej. NA 60 db 60 db 60 db 60 db 60 db 60 db Operating temp. -73 C to 121 C [-100 F to 250 F] -28 C to 85 C [-20 F to 185 F] -40 C to 93 C [-40 F to 200 F] -40 C to 85 C [-40 F to 185 F] -40 C to 85 C [-40 F to 185 F] -40 C to 85 C [-40 F to 185 F] -28 C to 85 C [-20 F to 185 F] Reverse volt. prot. NA Yes Yes Yes Yes Yes Yes Short cir. protection NA Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std)5 A (+) Excitation B (+) Excitation C (-) Excitation D (-) Excitation E (-) Output F (+) Output A (+) Supply B Output com. C Supply ret. D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B Output com ** C Supply ret ** D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B Output com ** C Supply ret ** D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B Output com ** C Supply ret ** D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B No conn. C No conn. D (+) Output E Case ground F No conn. A (+) Supply B No conn. C No conn. D (+) Output E Case ground F No conn. Wiring code: cable5,6,7 R (+) Excitation Bl (-) Excitation G (-) Output W (+) Output R (+) Supply Bl Output com. G Supply ret. W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl Output com* G Supply ret.* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl Output com* G Supply ret.* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl Output com* G Supply ret.* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl (+) Output W Case ground R (+) Supply Bl (+) Output W Case ground Reference application sheet #008-0356-00 Reference application sheet #008-0357-00 Reference application sheet #008-0360-00 Reference application sheet #008-0361-00 Reference application sheet #008-0361-60 See Honeywell Web site for info on intrinsically safe approvals. #008-0547-00 For current information * Black and green wires are internally connected. * ** Pins B and C are internally connected. Honeywell * Sensing and Control 5 Model TJE NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Precision Gage/Absolute Pressure Transducer Accuracies stated are expected for best fit straight line for all errors including linearity, hysteresis & non-repeatability thru zero. Output for 0.5 psig/a, 1 psig/a, 2 psig/a units is 1 mV/V to 2 mV/V. Input power (voltage) for internal amplifier options 2j, 2k, 2n(2N) depends on load resistance. CE mark requires options 6a & 3d. Interconnecting shunt cal. 1 with shunt cal. 2 terminal provides 50 % (unamplified units), 75% (4 mA to 20 mA three-wire units), or 80 % (voltage amp. units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2a, 2b, 2c, 2t and 2j. G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow; R=Red; O=Orange. Color specifying cable and number or letter specifying connector. No mating connector necessary with cable option. Options 2k, 2n(2N) only available with option 12b. Availability varies according to range. Not available with temperatures below -29 C [-20 F] or above 85 C [185 F]. Cannot be used with amplified option. Gage pressure units greater than 500 psi are sealed at atmospheric pressure. No pot access available with MS type connector. Temperature 82 C [180 F] max., non-shielded standard, shielded available. Input/output isolation only available with voltage output (options 2a, 2b, 2c). Consult factory for TEDS availability with amplified models. 5000 ohm bridge required. Range dependent; consult factory. Termination dependent; consult factory. Internal amp and termination dependent; consult factory. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY * DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008606-1-EN IL50 GLO May 2008 Copyright (c) 2008 Honeywell International Inc. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: 060-0743-06TJG 060-0743-03TJG 060-0708-10TJG 060-0743-11TJG 060-0761-29TJG 060-0708-18TJG