Precision Gage/Absolute
Pressure Transducer
Model TJE
DESCRIPTION
Model TJE pressure transducers are all-welded stainless steel
sensors built for rugged industrial applications that require high
accuracy and measurement stability. The Model TJE is available
with a variety of options for extended temperature operation,
electrical terminations and high-level outputs including 5 Vdc or
10 Vdc and 4 mA to 20 mA. Most high-level output models have
internal shunt calibration circuits as a standard feature to allow
easy set-up of the sensor to the data system. An optional internal
signature calibration chip provides calibration information for
automatic set up with the Model SC four-or-twelve channel digital
indicator.
The gage Model TJE is a strain gage based transducer and
features a unique “true gage” design which utilizes a second
welded stainless steel diaphragm that hermetically seals the
strain gage circuitry from atmospheric contamination. This
design references the primary pressure sensing diaphragm to
the atmosphere, and provides a stable zero regardless of the
transducer environment.
The absolute Model TJE has an all-welded vacuum reference
chamber assuring long-term stability.
FEATURES
• 0.1%accuracy
• 0.0025%F.S./°Ftemperatureeffect
• 1psig/ato60000psig/arange
• mV/V,4mAto20mA,0Vdcto5Vdc,or0Vdcto10Vdc
output
• All-welded,stainlesssteelconstruction
• Intrinsicallysafeavailable(2Noptiononly)18
• CE19
2Honeywell•SensingandControl
Model TJE
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Accuracy1±0.10%fullscale
Linearity ±0.10%fullscale
Hysteresis ±0.05%fullscale
Media Allgases/liquidscompatiblewithwetted
parts
Resolution Innite
Calibration 5-pointcalibration:0%,50%,and100
%offullscale
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature compensated 15°Cto71°C[60°Fto160°F]
Temperature effect, zero 0.0025%fullscale/°F
Temperature effect, span 0.0025%reading/°F
Sealing HermeticallysealedIP68/NEMA6P
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Insulationresistance 5000 mOhm @ 50 Vdc
Bridge resistance 350 ohm
Shunt calibration data Included
Electricaltermination(std) PTIH-10-6Porequiv.
(hermeticstainless)
Matingconnector(notincl) PT06A-10-6Sorequiv.(AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Wetted parts material number here
<2000psig/a 17-4PHstainlesssteel
>2000psig/a 15-5PHstainlesssteel
Weight 10 oz
Case material 304 stainless steel
Marking PermanentmetalnameplateMIL-
STD130F4.3;Individualsequential
serialnumberpersensor;Countryof
origin and date of manufacture SPECIAL REQUIREMENTS (CONSULT FACTORY)
Haveaspecialrequirement?Newcasepressure,differentcablelengths,
electrical connectors, or materials? Consult our factory by calling +1
614-850-5000(800-848-6564).Customizationiskeytoourtestand
measurement business. Special outputs, wiring codes, and calibrations
are all standard to us.
MOUNTING DIAGRAM AND CHARACTERISTICS
TYPICAL SYSTEM DIAGRAM
Forreferenceonly
Honeywell•SensingandControl3
Precision Gage/Absolute Pressure Transducer
RANGE CODES
Pressure
range (psi) 12510 15 25 50 75 100 150 200 300 500 750 1000 1500
RANGE CODE AP AR AT AV BJ BL BN BP BR CJ CL CP CR CT CV DJ
D mm [in]
psia 57[2.25] 38[1.50]
D mm [in]
psig 57[2.25] 45[1.75] 38[1.50]
L mm [in]
psia 65[2.54] 60[2.35]
L* mm [in]
psia 96[3.79] 91[3.60]
L mm [in]
psig 46[1.81] 51[2.00] 51[2.02]
L* mm [in]
psig 78[3.06] 83[3.25] 83[3.27]
Over pressure
(test) (psi) 150%fullscale 150%fullscale
Over pressure
(burst) (psi) 50 100 200 400 800 2 k 3 k 3.5 k 4 k
Port volume
cm3 [in3] 5,2[0.32] 4,1[0.25] 2,8[0.17]
Natural
frequency
(Hz)
500 550 1000 1.3 k 2.1 k 2.5 k 2.9 k 3.5 k 4.6k 6k 7k 9 k 9.5 k 12 k 17k 20 k
Pressure
range
(psi)
2000 3000 5000 7500 10000 15000 20000 30000 50000 60000
RANGE CODE DL DN DR DT DV EJ EL EN EP ES
D mm [in] psia 38[1.50] 38[1.50]
L mm [in] psia 48[1.90] 56[2.21]
L* mm [in]
psia 80[3.15] 89[3.46]
Over pressure
(test) (psi) 150%fullscale Consult factory
Over pressure
(burst) (psi) 8 k 12 k 20 k 25 k 25 k 40 k 45 k 60k 80 k 80 k
Port volume
cm3 [in3] 3,1[0.12] 1,5[0.06]
Natural
frequency (Hz) 35 k 40 k 54 k 60k 80 k 100 k >100 k >100 k >100 k >100 k
*Lengthofpressuretransducerwithampliedoption(seeoptioncodes)
** 0.5 psi is available for gage only
4Honeywell•SensingandControl
Model TJE
OPTION CODES
Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Pressure
ranges
1,2,5,10,15,25,50,75,100,150,200300,750,1500,2000,15000,20000,30000,50000,60000psig/a
500,1000,3000,5000,7500,10000psia
500,1000,3000,5000,7500,10000psig
Temperature
compensation
1a.60°Fto160°F
1b.30°Fto130°F
1c.0°Fto185°F
1d.-20°Fto130°F
1e.-20°Fto200°F
1f.70°Fto250°F11
1g.70°Fto325°F11
1h.70°Fto400°F11
1i.-65°Fto250°F11
Internal
ampliers 10
2a.0Vdcto5Vdc(fourwire)output15
2c. 0-5 Vdc output15
2j.4mAto20mA(threewire)output
2k.4mAto20mA(twowire)output8,17
2n.4mAto20mA(twowire)intrinsicallysafe8,17
2t. 0 Vdc to 10 Vdc output
2u.Unamp.,mV/Voutput
Internal ampli-
er enhance-
ments
3a.Input/outputisolation15
3d. Remote buffered shunt calibration
Pressure
ports9
5a.1/4-18NPTfemale(3000psigto
10000psig)
5b.1/4-18NPTmale(15psig/ato10000
psig/a)
5c.7/16-20UNFfemale(per
MS33649-4)
5d.7/16-20UNFmale
5g.G1/4male
Electrical
termination
6a.BendixPTIH-10-6P(orequiv),6pin
(max250°F)
6b.MStypeconnectortomatewith
MS3106-14S6S(max160°F)13
6e.Integralcable:Teon(0°Fto180
°F)
6f.Integralcable:PVC(-20°Fto160°F)
6g.Integralcable:Neoprene(0°Fto
180°F)
6h.Integralcable:Silicone(-65°Fto
300°F)
6i.Integralunderwatercable(max
180°F)
6j.1/2-14conduitttingwith5ftof4
conductorPVCcable
6m.DIN43650
6q.Moldedintegralcable:Polyurethane(max
180°F)
6t.IntegralcablewithHeycospringstrain
relief(5ft)
Shunt calibra-
tion
8a.Precisioninternalresistor11
Special
calibration9
9a.10point(5up/5down)20%increments@70°F(gage)
9b.20point(10up/10down)10%increments@70°F(gage)
Wetted
diaphragm9
10a.316stainlesssteel9
10b.CrucibleA-286
10c. Hastelloy-C
10d. Monel K-500
Bridge
resistance9
12a.1000ohm(foil)(max400°F)
12b.5000ohm(foil)(max400°F)
Zero and span
adjustment
14a.Noaccesstopots
14b. Top access to pots
Shock and
vibration
44a. Shock and vibration resistance
Interfaces 53e. Signature calibration11
53t.TEDSIEEE1451.4module16
Honeywell•SensingandControl5
Precision Gage/Absolute Pressure Transducer
iNTERNAL AMPLIFIERS
Amplier
specications
mV/V output
standard
Voltage out-
put: Option
2a4
Vehicle volt-
age output:
Option 2c4
Vehicle voltage
output: Option
2t4
Current
three-wire:
Option 2j4
Current two-
wire:
Option 2k4
Intrinsically
safe amp: Op-
tion 2N (2n)
Output signal 3mV/V20 Vdc to 5 Vdc 0-5 Vdc or ±5
Vdc @ 5 mA
0-10 Vdc or ±10
Vdc @ 5 mA
4 mA to 20
mA
4 mA to 20 mA 4 mA to 20 mA
Input power
(voltage)
10 Vdc regu-
lated
±15 Vdc or
26-32Vdc
11 Vdc to 28
Vdc
15 Vdc to 28 Vdc 22 Vdc to 32
Vdc3
9 Vdc to 32
Vdc3
9 Vdc to 28
Vdc3
Input power
(current)
28.5 mA @ 10
Vdc
45 mA 40 mA 40 mA 65mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp
(amp)
Naturalfre-
quency
2000 Hz 3000 Hz 3000 Hz 2500 Hz 2500 Hz 2000 Hz
Power supply
rej.
NA 60db 60db 60db 60db 60db 60db
Operating
temp.
-73°Cto121
°C[-100°Fto
250°F]
-28°Cto85°C
[-20°Fto185
°F]
-40°Cto93°C
[-40°Fto200
°F]
-40°Cto85°C
[-40°Fto185°F]
-40°Cto85
°C[-40°Fto
185°F]
-40°Cto85°C
[-40°Fto185
°F]
-28°Cto85°C
[-20°Fto185
°F]
Reverse volt.
prot.
NA Yes Yes Yes Yes Yes Yes
Short cir.
protection
NA Momentary Momentary Momentary Yes Yes Yes
Wiring code:
connector
(std)5
A(+)Excitation
B(+)Excitation
C(-)Excitation
D(-)Excitation
E(-)Output
F(+)Output
A(+)Supply
B Output com.
C Supply ret.
D(+)Output
E Shunt Cal 1
FShuntCal2
A(+)Supply
B Output com **
C Supply ret **
D(+)Output
E Shunt Cal 1
FShuntCal2
A(+)Supply
B Output com **
C Supply ret **
D(+)Output
E Shunt Cal 1
FShuntCal2
A(+)Supply
B Output com
**
C Supply
ret **
D(+)Output
E Shunt Cal 1
FShuntCal2
A(+)Supply
BNoconn.
CNoconn.
D(+)Output
E Case ground
FNoconn.
A(+)Supply
BNoconn.
CNoconn.
D(+)Output
E Case ground
FNoconn.
Wiring code:
cable5,6,7
R(+)Excitation
Bl(-)Excitation
G(-)Output
W(+)Output
R(+)Supply
Bl Output com.
G Supply ret.
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl Output com*
G Supply ret.*
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl Output com*
G Supply ret.*
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl Output
com*
G Supply ret.*
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl(+)Output
W Case ground
R(+)Supply
Bl(+)Output
W Case ground
For current
information
Reference ap-
plication sheet
#008-0356-00
Reference ap-
plication sheet
#008-0357-00
Reference ap-
plication sheet
#008-0360-00
Reference ap-
plication sheet
#008-0361-00
Reference ap-
plication sheet
#008-0361-60
See Honeywell
Web site for info
on intrinsically
safe approvals.
#008-0547-00
*Blackandgreenwiresareinternallyconnected.•**PinsBandCareinternallyconnected.
Sensing and Control
Automation and Control Solutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008606-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Model TJE Precision Gage/Absolute Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
tootherwisebyHoneywellinwriting;pleaserefertoyour
orderacknowledgementorconsultyourlocalsalesofcefor
specicwarrantydetails.Ifwarrantedgoodsarereturnedto
Honeywell during the period of coverage, Honeywell will repair
orreplace,atitsoption,withoutchargethoseitemsitnds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specicationsmaychangewithoutnotice.Theinformationwe
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visit
www.honeywell.com/sensingorcall+1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stopdevicesorinanyotherapplicationwherefailureof
theproductcouldresultinpersonalinjury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisfor
referenceonly.DONOTUSEthisdocumentasproduct
installationinformation.
•Completeinstallation,operationandmaintenance
informationisprovidedintheinstructionssuppliedwith
eachproduct.
Failure to comply with these instructions could result in
death or serious injury.
NOTES
1. Accuraciesstatedareexpectedforbesttstraightlineforallerrors
including linearity, hysteresis & non-repeatability thru zero.
2. Outputfor0.5psig/a,1psig/a,2psig/aunitsis1mV/Vto2mV/V.
3. Inputpower(voltage)forinternalamplieroptions2j,2k,2n(2N)
depends on load resistance.
4. CEmarkrequiresoptions6a&3d.
5. Interconnectingshuntcal.1withshuntcal.2terminalprovides50
%(unampliedunits),75%(4mAto20mAthree-wireunits),or
80%(voltageamp.units)offullscaleoutputforquickcalibration.
Shuntcalibrationcomesstandardwithinternalamplieroptions2a,
2b, 2c, 2t and 2j.
6. G=Green;B=Blue;W=White;Bl=Black;Br=Brown;Y=Yellow;
R=Red;O=Orange.Colorspecifyingcableandnumberorletter
specifying connector.
7. Nomatingconnectornecessarywithcableoption.
8. Options2k,2n(2N)onlyavailablewithoption12b.
9. Availability varies according to range.
10. Notavailablewithtemperaturesbelow-29°C[-20°F]orabove85
°C[185°F].
11. Cannotbeusedwithampliedoption.
12. Gage pressure units greater than 500 psi are sealed at atmospheric
pressure.
13. NopotaccessavailablewithMStypeconnector.
14. Temperature82°C[180°F]max.,non-shieldedstandard,shielded
available.
15. Input/outputisolationonlyavailablewithvoltageoutput(options2a,
2b,2c).
16. ConsultfactoryforTEDSavailabilitywithampliedmodels.
17. 5000ohmbridgerequired.
18. Rangedependent;consultfactory.Terminationdependent;consult
factory.
19. Internalampandterminationdependent;consultfactory.