Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (412) 925-7272
CR3AMZ
Inver ter Grade SCR
for Strobe Flasher Applications
0.4 Amperes/400 Volts
S-2
Absolute Maximum Ratings, Ta= 25 °C unless otherwise specified
Ratings Symbol CR3AMZ-8 Units
Repetitive Peak Off-state Voltage VDRM 400 Volts
Repetitive Peak Reverse Voltage VRRM 400 Volts
Non-repetitive Peak Off-state Voltage VDSM 480 Volts
Non-repetitive Peak Reverse Voltage VRSM 480 Volts
Average On-state Current, Single Phase Half Sinewave IT(avg) 0.4 Amperes
Peak On-state Current ITRM 200 Amperes
Peak Gate Power Dissipation PGM 0.5 Watts
Average Gate Power Dissipation PG(avg) 0.1 Watts
Peak Forward Gate Current IFGM 0.5 Amperes
Peak Forward Gate Voltage VFGM 6 Volts
Storage Temperature T(stg) -40 to 125 °C
Operating Junction Temperature Tj-40 to 125 °C
Weight (Typical) – 1.1 Grams
Electrical and Thermal Characteristics
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Current – Conducting State
Peak On-state Voltage Drop VTM Ta= 25°C, ITM = 3A Peak – – 2.0 Volts
Voltage – Blocking State
Forward Leakage, Peak IDRM Tj= 25°C, VDRM = Rated – – 0.1 mA
Reverse Leakage, Peak IRRM Tj= 25°C, VRRM = Rated – – 0.1 mA
Gate – Parameters
Gate Current to Trigger IGT VD= 6V, RL= 6V, Tj= 25°C – – 30 mA
Gate Voltage to Trigger VGT VD= 6V, RL= 6V, Tj= 25°C – – 1.5 Volts
Non-triggering Gate Voltage VGD VD= YZVDRM, RL= 6V, Tj= 125°C 0.1 – – Volts
Commutating Capacitor CCCM= 700mF, VCM = 350V, ITM = 200A, – – 2.2 mF
L = 25mH, Ta= 25°C