LESHAN RADIO COMP ANY , LTD.
10C–1/2
RS601
RS602
RS603
RS604
RS605
RS606
RS607
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25
°
C ambient temperature unless otherwise specified. Single phase,half wave,
60Hz,resistive or inductive load. For capacitive load,derate current by 20%.
6.0A
6.0A BRIDGE RECTIFIERS
RS601 – RS607
KBU601 – KBU607
TYPE
PRV
V PK
Maximum
Average
Forward
Output
Current
@TA=70
°
C
Maximum
Forward Peak
Surge Current
@ 8.3ms
Superimposed
Maximum DC
Forward Voltage
drop per element
at IF =3.0ADC
I O
A AV
IFM (Surge)
A PK
IR
25
°
CTA 125
°
CTA
µADC µADC
TJ
°C
Package
Dimensions
Maximum DC
Reverse Current
at rated DC
Blocking Voltage
per element
VF
VPK
Maximum
Peak
Reverse
Voltage
RS – 6
6.0 200 10 500 125
1.1
KBU601
KBU602
KBU603
KBU604
KBU605
KBU606
KBU607
50
100
200
400
600
800
1000
Operating
Junction
Temperature
.079(2.0)
.087(2.2)
.935(23.7)
.895(22.7)
.700(17.8)
.600(16.8)
1.00 MIN
(25.4) .052(1.3) DIA
.048(1.2)
.15 φ ± .23L
13.8 φ ± 5.7L
HOLE THRU
.300
(7.5)
.280(7.1)
.268(6.8)
.220(5.6)
.180(4.6)
.15
RS – 6
.780(19.8)
.740(18.8)
LESHAN RADIO COMP ANY , LTD.
10C–2/2
RS601-RS607 KBU601-KBU607
BRIDGE RECTIFIERS RATING AND CHARACTERISTIC CURVES
FIG. 2 - MAXIMUM NON-REPETITIVE
SURGE CURRENT
INSTANT ANEOUS REVERSE CURRENT MICROAMPERES
PERCENT OF RATED PEAK REVERSE VOLTAGE,(%)
0 50 100 150
6
4
2
0
20 40 60 80 100 120 140
100
10
1.0
.1
TC = 100°C
FIG. 3 - TYPICAL REVERSE CHARACTERISTICS
FIG. 1 - TYPICAL FORWARD CURRENT
DERATING CURVE
AVERAGE FORWARD OUTPUT CURRENT AMPERES
PEAK FORWARD SURGE CURRENT.AMPERES
250
225
200
175
150
125
100
75 1 2 5 10 20 50 100
AMBIENT TEMPERATURE.°C NUMBER OF CYCLES AT 60Hz
TA = 25°C
INSTANTANEOUS FORWARD CURRENT AMPERES
INSTANT ANEOUS FORWARD VOLTAGE.VOLTS
6 7 8 9 10 11 12 13
100
40
20
10
4.0
2.0
1.0
0.4
0.2
0.1
FIG. 4 - TYPICAL INSTANTANEOUS FORWARD
PER BRIDGE ELEMENT
TJ = 25°C
8.3ms Single Sine-Wave
MOUNTES ON 4:4 INCH CPUFER
PC BOARD
0.5”(12.7mm) Lead length
TJ = 25°C
8.3ms Single Sine-Wave