2007-03-29 Silicon NPN Phototransistor NPN-Silizium-Fototransistor Version 1.0 BPX 38 Features: Besondere Merkmale: * Spectral range of sensitivity: 450 ... 1120 nm * Spektraler Bereich der Fotoempfindlichkeit: 450 ... 1120 nm * Gehause: Metall Gehause (TO-18), hermetisch dicht * Besonderheit: Basisanschluss * Geeignet bis 125 C * Hohe Linearitat * Gruppiert lieferbar * Package: Metal Can (TO-18), hermetically sealed * * * * Special: Base connection Suitable up to 125 C High linearity Available in groups Applications Anwendungen * Photointerrupters * Industrial electronics * For control and drive circuits 2007-03-29 * Lichtschranken * Industrieelektronik * Messen / Steuern / Regeln 1 Version 1.0 BPX 38 Ordering Information Bestellinformation Type: Photocurrent Typ: Fotostrom Ordering Code Bestellnummer 2 = 950 nm, Ee = 0.5 mW/cm , VCE = 5 V IPCE [A] BPX 38 200 Q62702P0015 BPX 38-2/3 200 ... 630 Q62702P3578 BPX 38-3 320 ... 630 Q62702P0015S003 BPX 38-4 500 ... 1000 Q62702P0015S004 Note: Only one bin within one packing unit (variation less than 2:1) Anm.: Nur eine Gruppe pro Verpackungseinheit (Streuung kleiner 2:1) Maximum Ratings (TA = 25 C) Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating and storage temperature range Betriebs- und Lagertemperatur Top; Tstg -40 ... 125 C Collector-emitter voltage Kollektor-Emitter-Spannung VCE 50 V Collector current Kollektorstrom IC 50 mA Collector surge current Kollektorspitzenstrom ( < 10 s) ICS 200 mA Emitter-base voltage Emitter-Basis-Spannung VEB 7 Total power dissipation Verlustleistung Ptot 220 mW Thermal resistance Warmewiderstand RthJA 450 K/W 2007-03-29 2 V Version 1.0 BPX 38 Characteristics (TA = 25 C) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Wavelength of max. sensitivity Wellenlange der max. Fotoempfindlichkeit S max 880 nm Spectral range of sensitivity Spektraler Bereich der Fotoempfindlichkeit 10% 450 ... 1120 nm Radiant sensitive area Bestrahlungsempfindliche Flache A Dimensions of chip area Abmessung der Chipflache LxW Half angle Halbwinkel 40 Photocurrent of collector-base photodiode Fotostrom der Kollektor-Basis-Fotodiode ( = 950 nm, Ee = 0.5 mW/cm2, VCB = 5 V) IPCB 1.8 A Photocurrent of collector-base photodiode Fotostrom der Kollektor-Basis-Fotodiode (EV = 1000 lx, Std. Light A, VCB = 5 V) IPCB 5.5 A Capacitance Kapazitat (VCE = 0 V, f = 1 MHz, E = 0) CCE 23 pF Capacitance Kapazitat (VCB = 0 V, f = 1 MHz, E = 0) CCB 39 pF Capacitance Kapazitat (VEB = 0 V, f = 1 MHz, E = 0) CEB 47 pF Dark current Dunkelstrom (VCE = 25 V, E = 0) ICE0 20 ( 100) nA 2007-03-29 3 0.675 mm2 1.02 x 1.02 mm x mm Version 1.0 BPX 38 Grouping (TA = 25 C, = 950 nm) Gruppierung Group Min Photocurrent Max Photocurrent Typ Photocurrent Rise and fall time Gruppe Min Fotostrom Max Fotostrom Typ Fotostrom Ee = 0.5 mW/cm2, VCE = 5 V Ee = 0.5 mW/cm2, VCE = 5 V EV = 1000 lx, Std. IC = 1 mA, Light A, VCE = 5 V VCC = 5 V, RL = 1 k Anstiegs- und Abfallzeit IPCE, min [A] IPCE, max [A] IPCE [A] tr, tf [s] BPX 38-2 200 400 950 9 BPX 38-3 320 630 1500 12 BPX 38-4 500 1000 2300 15 BPX 38-5 800 3600 18 Group Collector-emitter saturation voltage Current gain Gruppe Kollektor-Emitter Sattigungsspannung Stromverstarkung IC = IPCEmin x 0.3, Ee= 0.5 mW/cm2 Ee = 0.5 mW/cm2, VCE = 5 V VCEsat [mV] IPCE / IPCB BPX 38-2 200 170 BPX 38-3 200 280 BPX 38-4 200 420 BPX 38-5 200 650 Note.: IPCEmin is the min. photocurrent of the specified group. Anm.: IPCEmin ist der minimale Fotostrom der jeweiligen Gruppe. 2007-03-29 4 Version 1.0 BPX 38 Relative Spectral Sensitivity Relative spektrale Empfindlichkeit Srel = f() Photocurrent Fotostrom IPCE = f(Ee), VCE = 5 V Collector Current Kollektorstrom IC = f(VCE), IB = Parameter Collector Current Kollektorstrom IC = f(VCE), I B = Parameter 2007-03-29 5 Version 1.0 BPX 38 Photocurrent Fotostrom IPCE / IPCE(25C)= f(TA), VCE = 5 V Dark Current Dunkelstrom ICEO = f(VCE), E = 0 Dark Current Dunkelstrom ICEO/ICEO(25) = f(TA), VCE = 25 V, E = 0 Collector-Base Capacitance Kollektor-Basis Kapazitat CCB = f(VCB), f = 1 MHz, E = 0 2007-03-29 6 Version 1.0 BPX 38 Emitter-Base Capacitance Emitter-Basis Kapazitat CEB = f(VEB), f = 1 MHz, E = 0 Collector-Emitter Capacitance Kollektor-Emitter Kapazitat CCE = f(VCE), f = 1 MHz, E = 0 Total Power Dissipation Verlustleistung Ptot = f(TA) 2007-03-29 7 Version 1.0 BPX 38 Directional Characteristics Winkeldiagramm Srel = f() Package Outline Mazeichnung Radiant sensitive area 0.9 14.5 (0.571) 5.3 (0.209) 12.5 (0.492) 5.0 (0.197) 5.5 (0.217) 1.1 (0 (0 .03 .04 5) 3) .04 5) .03 1. (0 0.9 0 1( 3) E C B 2.54 (0.100) spacing o0.45 (0.018) o4.8 (0.189) (2.7 (0.106)) o4.6 (0.181) Chip position o5.6 (0.220) o5.3 (0.209) 5.0 (0.197) Approx. weight 1.0 g GMOY6018 Dimensions in mm (inch). / Mae in mm (inch). 2007-03-29 8 Version 1.0 BPX 38 TTW Soldering Wellenloten (TTW) IEC-61760-1 TTW / IEC-61760-1 TTW OHLY0598 300 C T 10 s 250 Normalkurve standard curve 235 C ... 260 C Grenzkurven limit curves 2. Welle 2. wave 200 1. Welle 1. wave 150 ca 200 K/s 2 K/s 5 K/s 100 C ... 130 C 100 2 K/s 50 Zwangskuhlung forced cooling 0 0 50 100 150 200 t 2007-03-29 9 s 250 Version 1.0 BPX 38 Disclaimer Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you - get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. Bitte beachten! Lieferbedingungen und Anderungen im Design vorbehalten. Aufgrund technischer Anforderungen konnen die Bauteile Gefahrstoffe enthalten. Fur weitere Informationen zu gewunschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nachstgelegene Vertriebsburo. Wir nehmen das Verpackungsmaterial zuruck, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Fur Verpackungsmaterial, das unsortiert an uns zuruckgeschickt wird oder das wir nicht annehmen mussen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, mussen fur diese Zwecke ausdrucklich zugelassen sein! Kritische Bauteile* durfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverstandnis von OSRAM OS vorliegt. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems fuhren wird oder die Sicherheit oder Effektivitat dieses Apparates oder Systems beeintrachtigt. **) Lebenserhaltende Apparate oder Systeme sind fur (a) die Implantierung in den menschlichen Korper oder (b) fur die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. 2007-03-29 10 Version 1.0 BPX 38 Published by OSRAM Opto Semiconductors GmbH Leibnizstrae 4, D-93055 Regensburg www.osram-os.com (c) All Rights Reserved. 2007-03-29 11