TES 2H Series, 2 Watt
http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load / full load 5 Vin; 3.3 VDC model: 60 mA / 470 mA typ.
5 Vin; other models: 60 mA / 540 mA typ.
12 Vin; 3.3 VDC model: 30 mA / 190 mA typ.
12 Vin; other models: 30 mA / 210 mA typ.
24 Vin; 3.3 VDC model: 15 mA / 95 mA typ.
24 Vin; other models: 15 mA / 110 mA typ.
Surge voltage (1 sec. max.) 5 Vin models: 9 V max.
12 Vin models: 18 V max.
24 Vin models: 30 V max.
Under voltage shut down 12 Vin models: 8 VDC typ.
24 Vin models: 16 VDC typ.
48 Vin models: 34 VDC typ.
Reverse voltage protection 0.3 A max.
Input filter internal capacitor
Output Specifications
Voltage set accuracy see graphs below
Voltage balance (dual output models, balanced load) 1 % max.
Regulation – Input variation 1.2 % / 1 % change Vin
– Load variation 0 – 100 % see graphs below
Minimum load not required
Ripple and noise (20 MHz Bandwidth) 120 mVp-p max.
Temperature coefficient ±0.02 %/K typ.
Short circuit protection limited 0.5s max.
Capacitive load 3.3 & 5.0 VDC models: 47 µF max.
12 & ±5 VDC models: 10 µF max.
±12 & ±15 VDC models: 4.7 µF max.
General Specifications
Temperature ranges – Operating (convection cooling 20LFM, 0,1m/s) –40°C to +85°C
– Case temperature +95°C max.
– Storage temperature –40°C to +125°C
Derating (convection cooling) 4 %/K above 75°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >2‘000‘000 h
Isolation voltage (60 sec.) 1’500 VDC
Isolation capacitance (100 kHz, 1V) 60 pF typ.
Isolation resistance (500 VDC) >10 Gohm
Switching frequency 50 to 120 kHz typ. (depend on load)
Physical Specifications
Casing material plastic (UL94V-0 rated)
Weight single output models: 1.5 g (0.05 oz)
dual output models: 2.2 g (0.08 oz)
Lead-free reflow solder process as per J-STD-020BD.1 (www.jedec.org)
Moisture sensivity level (MSL) level 2 as per J-STD-033B.1 (to find at:
www.jedec.org - free registration required)
Washing process not recommended. Product non-hermetical
Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU