Inductive sensor NJ5-18GK-N Technical Data 0 10 2 Model Number NJ5-18GK-N Features * * 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm General specifications Switching element function NAMUR, NC 5 mm Rated operating distance sn Installation flush Output polarity NAMUR Assured operating distance sa 0 ... 4.05 mm 0.4 Reduction factor rAl Reduction factor rCu 0.3 0.85 Reduction factor r304 Nominal ratings Nominal voltage Uo 8.2 V (Ri approx. 1 k) Switching frequency f 0 ... 500 Hz Hysteresis H 1 ... 10 typ. 5 % Current consumption 3 mA Measuring plate not detected 1 mA Measuring plate detected Ambient conditions Ambient temperature -25 ... 100 C (-13 ... 212 F) Mechanical specifications Connection type cable PVC , 2 m Core cross-section 0.75 mm2 Housing material PBT/PPS Sensing face PBT Degree of protection IP66 / IP68 General information Use in the hazardous area see instruction manuals 2G; 1D Category Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 EN 60947-5-2:2007 IEC 60947-5-2:2007 Standards Approvals and certificates FM approval Control drawing UL approval CSA approval CCC approval 116-0165F cULus Listed, General Purpose cCSAus Listed, General Purpose CCC approval / marking not required for products rated 36 V Dimensions 39 35.5 44 1 M18 x 1 Release date: 2015-04-06 17:24 Date of issue: 2015-04-06 106444_eng.xml 24 Electrical Connection Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com BN BU L+ L- Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 1 Inductive sensor NJ5-18GK-N ATEX 2G Instruction Manual electrical apparatus for hazardous areas Device category 2G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X CE marking ATEX marking 0102 II 2G Ex ia IIC T6...T1 Gb Directive conformity 94/9/EG Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions Appropriate type NJ 5-18GK-N... Effective internal capacitance Ci 70 nF ; a cable length of 10 m is considered. Effective internal inductance Li 50 H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Specific conditions When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Release date: 2015-04-06 17:24 Date of issue: 2015-04-06 106444_eng.xml Protection from mechanical danger 2 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com Inductive sensor NJ5-18GK-N ATEX 1D Instruction Manual electrical apparatus for hazardous areas Device category 1D for use in hazardous areas with combustible dust EC-Type Examination Certificate ZELM 03 ATEX 0128 X CE marking 0102 ATEX marking II 1D Ex iaD 20 T 108 C (226.4 F) Directive conformity 94/9/EG Standards IEC 61241-11:2002: draft; prEN61241-0:2002 type of protection intrinsic safety "iD" Use is restricted to the following stated conditions Appropriate type NJ 5-18GK-N... Effective internal capacitance Ci 70 nF ; a cable length of 10 m is considered. Effective internal inductance Li 50 H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Maximum housing surface temperature The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iaD. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 6007914 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Specific conditions The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. Release date: 2015-04-06 17:24 Date of issue: 2015-04-06 106444_eng.xml Electrostatic charging Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 3