Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6502UE Multi-Conductor - Commercial Applications For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Plenum-CMP 4-22 AWG stranded bare copper conductors with Flamarrest(R) insulation, Flamarrest(R) jacket with ripcord Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 4 22 7 BC - Bare Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Trade Name Insulation Material Flamarrest(R) Wall Thickness (mm) LS PVC - Low Smoke Polyvinyl Chloride 0.203 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest(R) Nom. Wall Thickness (mm) LS PVC - Low Smoke Polyvinyl Chloride 0.381 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm) Twists (twist/m) 76.1997 13.124 Overall Cabling Color Code Chart: Color Black Red White Green Overall Nominal Diameter: 3.531 mm Mechanical Characteristics (Overall) Operating Temperature Range: 0C To +75C Bulk Cable Weight: 22.323 Kg/Km Max. Recommended Pulling Tension: 161.914 N Min. Bend Radius/Minor Axis: 35.560 mm Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6502UE Multi-Conductor - Commercial Applications Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: NFPA 262 C(UL) Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 5502UE Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 88.587 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 52.8241 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.2 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 6502UE 877C500 152 MT 3.402 KG NATURAL Notes Item Desc 4 #22 FLRST FLRST 6502UE 877U1000 305 MT 7.258 KG NATURAL 4 #22 FLRST FLRST 6502UE 877U500 152 MT 3.856 KG NATURAL 6502UE 8771000 305 MT 7.258 KG NATURAL 6502UE 877500 152 MT 3.629 KG NATURAL 4 #22 FLRST FLRST C 4 #22 FLRST FLRST 4 #22 FLRST FLRST Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 03-13-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6502UE Multi-Conductor - Commercial Applications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013