(888) IPD-CONVerters (888) 473-2668 www.ipdconverters.com
1
OWT SERIES - TRIPLE OUTPUT, 25 WATT
TECHNICAL SPECIFICATIONS
OWT triple output DC/DC converters provide up to
25 Watts of output power in an industry standard 2” x 2”
package. OWT units feature excellent efficiency, five-
sided shielding, and fixed switching frequency. With
85°C case operation, the OWT is especially suited to
telecom, networking, and industrial applications.
Industry Standard
Package
12V Input
DESCRIPTION FEATURES
25W Output
External Enable Pin
5-Sided Shielding
500V Isolation
85°C Case Operation
Rev. 05/01
Remote Shutdown Positive
Remote Shutdown Reference Vin Negative
Switching Frequency 300 kHz
Isolation
Input - Output 500 VDC
Input - Case 500 VDC
Output - Case 500 VDC
Temperature Coefficient 0.02%/°C
Case Temperature
Operating Range -25 to +60°C1
Storage Range -40 to +125°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 -55 Hz
MTBF (Bellcore TR-NWT-000332) 1.8 x 106 hrs
Safety UL 1950, CSA 22.2-950, EN60950
General
Voltage Range
12 VDC Nominal 10 - 20 VDC
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 20 - 60 (add -S1 to p/n) or 36 - 72 VDC
Input Ripple Current 20% Iin Max.
Reverse Input Current 100% Iin Max.
Input
Setpoint Accuracy, Vout1 / Vout2 / Vout3 ±1%, ±5%, ± 5%
Line regulation Vin Min. - Vin Max., Iout Rated ±1% Vout
Load regulation Iout Min.- Iout Max., Vin Nom., Vout1 / Vout2 / Vout3
±1%, ±5%, ± 5%
Minimum Output Current 25 %
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500 µs
Short Circuit / Overcurrent Protection Continuous
Current Limit Threshold Range, % of Iout Rated 130%
Output
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
OWT4805-12
OWT4805-15
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
OWT2405-12
OWT2405-15
Efficiency vs. Load (48V Input)
Efficiency vs. Load (24V Input)
Notes
1 Industrial temp range of -40 to +85C available, add suffix -I to P/N
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
2
OWT SERIES - TRIPLE OUTPUT, 25 WATT
Natural Convection 14.9 °C/W
100 LFM 11.3 °C/W
200 LFM 8.3 °C/W
300 LFM 6.8 °C/W
400 LFM 5.4 °C/W
Tolerances
Pin Function
MECHANICAL DRAWING
Inches: (Millimeters)
.XX ± 0.040 .X ± 1.0
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
(Dimensions as listed unless otherwise
specified.)
Thermal Impedance
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
1+V
in
2-V
in
3 No Conn.
4 Enable
5 + Aux Out
6 +5V Out
7 Common
8 - Aux Out
MODELS - (See the last page of Section for options.)
DIA 0.040"
(4.6mm)
0.18" MIN.
2.00"
(50.8mm)
(1.0mm)
(12.7mm)
0.50"
5
2.00"
(50.8mm)
6
8
7
2
1
4
3
0.600"(15.2mm)
0.400"(10.2mm)
0
0.200"(5.1mm)
BOTTOM VIEW
-0.50"(-12.7mm)
0.300"(7.6mm)
-0.100"(-2.5mm)
0.700"(17.8mm)
1.100"(27.9mm)
-0.10"
(-2.5mm)
0
1.800"
(45.7mm)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. ** Model
12
12
24
24
48
48
48 WIDE
48 WIDE
10 - 20
10 - 20
18 - 36
18 - 36
20 - 60
20 - 60
36 - 72
36 - 72
3.7
3.7
2.4
2.4
2.3
2.3
1.4
1.4
5, ±12
5, ±15
5, ±12
5, ±15
5, ±12
5, ±15
5, ±12
5, ±15
3.5, ±0.31
3.5, ±0.25
3.5, ±0.31
3.5, ±0.25
3.5, ±0.31
3.5, ±0.25
3.5, ±0.31
3.5, ±0.25
50, 120
50, 150
50, 120
50, 150
50, 120
50, 150
50, 120
50, 150
78%
79%
81%
82%
81%
82%
81%
82%
OWT1205-12
OWT1205-15
OWT2405-12
OWT2405-15
OWT4805-12S1
OWT4805-15S1
OWT4805-12
OWT4805-15
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and
add them to the model number. Example ordering options are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used
in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manu-
factured. Specifications are subject to change without notice.
OPTIONS SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent Compatible Trim T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180"
(4.6mm)
0.110" (2.8mm) Pin Length 8 All Units (Except SMS)
0.150" (3.8mm) Pin Length 9 All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink 1H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink 1V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.45" (11.4mm) Horizontal Heatsink 2H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.45" (11.4mm) Vertical Heatsink 2V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.95" (24.1mm) Horizontal Heatsink 3H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.95" (24.1mm) Vertical Heatsink 3V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
Powering Communications and Technology