U5300 Industrial Pressure Transducer Superior Accuracy and Total Error Band CE Compliant Instrument Grade and Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber Weatherproof Gage, Sealed, Absolute, Compound Expedite Configurations Available (10 Days) DESCRIPTION The instrument grade U5300 pressure transducers from the UltraStable line of MEAS, with their modular design, offer maximum flexibility for different configurations. This latest series features superior accuracy and total error band for demanding commercial and heavy industrial applications. This series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids. The wetted material is made of 316L stainless steel and the transducer's durability is excellent with no o-rings or organics exposed to the pressure media. The U5300 is weatherproof and exceeds the latest heavy industrial CE requirements including surge protection. The circuit is protected from reverse wiring at input and short circuit at output. This product is geared to the OEM customer for low to mid volumes. MEAS stands ready to provide a custom design of the U5300 where the volume and application warrants. Additional configurations not listed are either available or possible. Please inquire for further information. FEATURES APPLICATIONS Heavy Industrial CE Approval Military/Aerospace Test Stands 10 V/m EMI Protection Automotive Test Stands Reverse Polarity Protection on Input Calibration Equipment Short Circuit Protection on Output High Accuracy Applications 0.1% Accuracy Stationary Motor Fuel Control 0.5% Total Error Band High End Industrial Machinery Compact Outline -40C to +125C Operating Temperature Weatherproof STANDARD RANGES Range (psi) Range (Bar) Gage Sealed Absolute Compound 0 to 002 0 to .14 0 to 005 0 to .35 0 to 015 0 to 001 0 to 030 0 to 002 0 to 050 0 to 3.5 0 to 100 0 to 007 0 to 200 0 to 014 0 to 300 0 to 020 0 to 500 0 to 035 0 to 01k 0 to 070 0 to 03k 0 to 200 0 to 05k 0 to 350 0 to 10k 0 to 700 Intermediate ranges available upon request. U5300 www.meas-spec.com 1/6 August 2015 U5300 Industrial Pressure Transducer PERFORMANCE SPECIFICATIONS Ambient Temperature: 25C (unless otherwise specified) PARAMETERS MIN Accuracy (RSS of linearity, hysteresis, and repeatability) -0.1 Isolation, Body to any Lead 100 TYP Dielectric Strength MAX UNITS 0.1 %F.S. BFSL 2 NOTES M @500VDC mA @500VAC, 1min Pressure Cycles 1.00E+6 0~FS Cycles Proof Pressure 3X 20k psi Rated Burst Pressure 4X 20k psi Rated Long Term Stability (1 year) -0.1 0.1 %F.S. Offset -0.25 0.25 %F.S. @25C Span -0.25 0.25 %F.S. @25C Total Error Band -0.5 0.5 %F.S. Over compensated temperature Compensated Temperature -20 +85 C Operating Temperature -40 +125 C Except cable 105C max Storage Temperature -40 +125 C Except cable 105C max Load Resistance (RL) RL > 100k Voltage Output Load Resistance (RL) < (Supply Voltage -9V) / 0.02A Current Output Current Consumption 5 mA Voltage Output Rise Time (10% to 90%) <2ms (Voltage Output); <3ms (Current Output); Without Snubber Pressure Port Material 316L Stainless Steel; 316L Stainless Steel Snubber Shock 50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A Vibration 20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L For custom configurations, consult factory. Notes Compensated Temperature: The temperature range over which the product will produce an output proportional to pressure within the specified performance limits. Operating Temperature: The temperature range over which the product will produce an output proportional to pressure but may n ot remain within the specified performance limits. Storage Temperature: The temperature range over which the product can be stored safely in occasions without pressure applied or power input and remains rated performance. Beyond this temperature range may cause permanent damage to the product. All configurations are built with supply voltage reverse and output short-circuit protections. CE Compliance EN 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (8kV contact/15kV air) IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (10V/m, 80M-1GHz) IEC 61000-4-4 Electrical Fast Transient Immunity (1kV) IEC 61000-4-5 Surge Immunity (V+ to V-: 2KV/42; L to Case: 1KV/12; V- to V0: 1KV/42) IEC 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency Fields (150K~80MHz, 10V level for voltage output models, 3V level for current output model) IEC 61000-4-9 Pulse Magnetic Field Immunity (100A/m peak) For all CE compliance tests, max allowed output deviation 1.5 %F.S. U5300 www.meas-spec.com 2/6 August 2015 U5300 Industrial Pressure Transducer DIMENSIONS [mm] CODE CONNECTION TYPE DIM A 1 CABLE 2 FT 2.19 [55.6] E CABLE 3 FT 2.19 [55.6] 2 CABLE 4 FT 2.19 [55.6] 3 CABLE 10 FT 2.19 [55.6] 4 PACKARD CONNECTOR A 2.25 [57.2] 5 BAYONET CONNECTOR 2.11 [53.6] 6 FORM C 1.95 [49.5] 7 FORM A 2.10 [53.3] 9 PACKARD CONNECTOR B 2.25 [57.2] D M12 CONNECTOR 1.95 [49.5] M CABLE 1 M 2.19 [55.6] N CABLE 2 M 2.19 [55.6] P CABLE 5 M 2.19 [55.6] R CABLE 10 M 2.19 [55.6] A AMP CONNECTOR 2.10 [53.3] S SUMITOMO CONNECTOR 1.95 [49.5] C 1/2" NPT CONDUIT 2.10 [53.3] 1 CODE 4 3 2 2 3 4 1 2 1 2 3 1 1/4-18 NPT 6 1/8-27 NPT B G1/4 JIS B2351 E 1/4-19 BSPT F 1/4-19 BSPP FEMALE (without snubber) P 7/16-20UNF FEMALE SAE J513 STRAIGHT THREAD WITH INTEGRAL VALVE DEPRESSOR N 7/16-20UNF FEMALE SAE J513 STRAIGHT THREAD Q M10 x 1.0 mm ISO 6149-2 S M12 x 1.5 mm ISO 6149-2 U G/14 DIN 3852 FORM E GASKET DIN3869-14 NBR W M20 x 1.5 mm ISO 6149-2 G M14 x 1.5 mm ISO 6149-2 2 3 Note: Refer to installation instructions supplied with devices for recommended torque. U5300 2 STRAIGHT THREAD ORING BUNA-N 90SH-904 5 3 123 PRESSURE PORT TYPE PORT DIM B 0.472 1/4-19 BSPP [11.94] 0.540 G3/8 JIS B2351 [13.72] 7/16-20UNF MALE SAE J19260.433 www.meas-spec.com 3/6 DIM C REF. 0.366 [9.3] 0.366 [9.3] 0.366 [11.0] [9.3] 0.600 [15.24] 0.390 [9.91] 0.472 [11.94] 0.500 [12.7] 0.771 [19.58] 0.366 [9.3] 0.366 [9.3] 0.366 [9.3] 0.366 [9.3] 0.366 [9.3] 0.687 0.366 [17.5] [9.3] 0.687 [17.5] 0.374 [9.5] 0.433 [11.0] 0.472 [11.94] 0.551 [14.0] 0.433 [11.0] 0.366 [9.3] 0.366 [9.3] 0.366 [9.3] 0.445 [11.3] 0.366 [9.3] 0.366 [9.3] August 2015 U5300 Industrial Pressure Transducer WIRING CONNECTION Bayonet Packard, A A B C Packard, B B A C Cable 1/2NPT CONDUIT RED RED BLK BLK M12 1 3 2,4 AMP/TE 1 2 3 FORM C 1 2 3,4 FORM A 1 2 3,4 Sum itom o 1 2 3 CONNECTION Bayonet Notes: 1. 2. U5300 Current Output Wiring NC. PINS +SUPPLY -SUPPLY C,D,E A B Voltage Output Wiring +SUPPLY +OUTPUT COMMON A B C P REF VENT F Hole Through Connector Hole Through Connector In Cable In Cable Hole Through Connector Hole Through Connector Threads Through Connector Threads Through Connector Hole Through Connector NC. PINS D,E Packard, A A C B Packard, B B C A Cable 1/2NPT CONDUIT RED RED WHT WHT BLK BLK M12 1 2 3 AMP/TE 1 3 2 FORM C 1 2 3 4 FORM A 1 3 2 4 Sum itom o 1 3 2 4 P REF VENT F Hole Through Connector Hole Through Connector In Cable In Cable Hole Through Connector Hole Through Connector Threads Through Connector Threads Through Connector Hole Through Connector NC pins are reserved for factory use only. Customers should not use these connections. For cable connection, the drain wire is internally terminated to pressure port. www.meas-spec.com 4/6 August 2015 U5300 Industrial Pressure Transducer CONNECTION TYPES CONNECTION TYPES MATING HOUSING P/N PT06A-10-6S MIL-C-26482 12078090 MATING TERMINAL P/N 12103881, QTY 3 RUBBER SEAL P/N - 4-WIRE,22 AWG, SHIELDED, PVC JACKET, 105 DEGC - - - M12 BINDER SERIES 713, 09 3431 77 04 OR EQUIV 4-POS FEMALE CONNECTOR - - AMP/TE AMP / TE 3-PIN ECONOSEAL J SERIES 174357-2 & 174358-7 171630-1 (AWG 20~24) 171662-1 (AWG 16~20) QTY 3 172746-1 (AWG 20~24) 172888-2 (AWG 16~20) QTY 3 FORM C INDUSTRIAL STANDARD 9.4MM FORM C HIRSCHMANN 933 024-100,OR, ATAM KD046000B7 (SEAL INCL.) - HIRSCHMANN 730 185-002 FORM A DIN EN 175 301-803-A 18MM HIRSCHMANN 931 969-100,OR, ATAM KA245000B4 (SEAL INCL.) - HIRSCHMANN 730 801-002 6189-6907 8100-3067 (AWG 20~22) 8100-3068 (AWG 16~18) QTY 3 7165-1075 (INS. DIA 1.1~1.6MM) 7176-0621 (INS. DIA 1.6~1.9MM) 7165-0622 (INS. DIA 1.8~2.2MM) QTY 3 CONNECTION DESCRIPTION Bayonet Packard Cable & 1/2NPT Conduit BAYONET PTIH-10-6P OR EQUIV 3-PIN METRI-PACK 150 Sum itom o SUMITOMO 3-PIN HV040 Note: Transmitter of gage pressure type requires vent to atmosphere on the pressure reference side. This is accomplished via cable from the transmitter (the end of the cable should be terminated to clean and dry area) or through the customer mating connector/cable assembly which has internal vent path. Suggested vented M12 mating connector P/N MB12FWAFF04ST-4 and MB12FWAFF04ST-3 at www.finecables.com for 0.157"~0.236" and 0.236"~0.315" diameter cable respectively. WEATHERPROOF WEATHER-PROOF RATING CONNECTION IP CODE Bayonet IP67 Packard IP66 Cable IP67 1/2NPT CONDUIT IP67 M12 IP67 AMP/TE IP67 FORM C IP65 FORM A IP65 Sum itom o IP67 Note: Weatherproof ratings are met when the mating connectors are installed properly and the cable termination is to dry and clean area. OUTPUTS CODE 3 4 5 6 7 8 9 U5300 OUTPUT SIGNAL 0.5 - 4.5V RATIOMETRIC 1 - 5V 4 - 20mA 0 - 5V 0 - 10V 1 - 6V 0.5 - 4.5V SUPPLY VOLTAGE 5 0.25V PROTECTED to 30V 8 - 30V 9 - 30V 8 - 30V 12 - 30V 8 - 30V 5 - 30V www.meas-spec.com 5/6 August 2015 U5300 Industrial Pressure Transducer ORDERING INFORMATION U53 3 Model Output Signal U53 3 = 0.5 - 4.5V Ratiometric 4 = 1 - 5V 5 = 4 - 20mA 6 = 0 - 5V 7 = 0 - 10V 8 = 1 - 6V 9 = 0.5 - 4.5V 1 - 0 0 00 0 5 Pressure Port Connection Type - Shipping Snubber 00 Label 1 = Cable 2 ft E = Cable 3 ft 2 = Cable 4 ft 3 = Cable 10 ft 4 = Packard Connector A 5 = Bayonet Connector 6 = Form C 7 = Form A 9 = Packard Connector B D = M12 Connector M = Cable 1 m N = Cable 2 m P = Cable 5 m R = Cable 10 m A = Amp Connector S = Sumitomo Connector C = 1/2" NPT Conduit - 0 = Standard H = Expedite 0 = No Snubber 1 = With Snubber 00 0 = Adhesive Label 1 = Laser Marking 2 = 1/4-19 BSPP 3 = G3/8 JIS B2351 4 = 7/16-20UNF Male SAE J514 Straight Thread ORing BUNA-N 90SH904 5 = 1/4-18 NPT 6 = 1/8-27NPT B = G1/4 JIS B2351 E = 1/4-19 BSPT F = 1/4-19 BSPP Female P = 7/16-20UNF Female SAE J514 with Integral Valve Depressor Q = M10 x 1.0 mm ISO 6149-2 N = 7/16-20UNF Female SAE J513 Straight Thread S = M12 x 1.5 mm ISO 6149-2 U = G1/4 DIN 3852 Form E Gasket DIN3869-14 NBR W = M20 x 1.5 mm ISO 6149-2 G = M14 x 1.5 mm ISO 6149-2 - 100P G - Pressure Range Pressure Type - 002P 005P .14B .35B G = Gage S = Sealed A = Absolute C = Compound 015P 030P 050P 100P 200P 300P 500P 001B 002B 3.5B 007B 014B 020B 035B G = Gage S = Sealed A = Absolute C = Compound 01KP 03KP 05KP 10KP 070B 200B 350B 700B G = Gage S = Sealed (Port 2, 5 only) A = Absolute (Port 2, 5 only) C = Compound Note: Selections in blue (expedite) have a 10 business day lead time with a 19 piece maximum order. Compound pressure range is -14.7 to xxxpsig or -1 to xxxbarg. (e.g. 200PC: -14.7 to 200psig, 020BC: -1 to 20barg) Refer to online installation instruction for recommended torque. Installation instructions will no longer be shipped with unit delivery. This document is available on our website in English and Chinese. Factory calibration certificate is provided. NORTH AMERICA EUROPE Measurement Specialties 45738 Northport Loop West Fremont, CA 94538 Tel: 1-800-767-1888 Fax: 1-510-498-1578 Sales: pfg.cs.amer@meas-spec.com Measurement Specialties (Europe), Ltd. 26 Rue des Dames 78340 Les Clayes-sous-Bois, France Tel: +33 (0) 130 79 33 00 Fax: +33 (0) 134 81 03 59 Sales: pfg.cs.emea@meas-spec.com ASIA Measurement Specialties (China), Ltd. No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen 518057 China Tel: +86 755 3330 5088 Fax: +86 755 3330 5099 Sales: pfg.cs.asia@meas-spec.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assum ed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rig hts to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer's technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. U5300 www.meas-spec.com 6/6 August 2015 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: U5354-000005-200PA U5354-000002-002BA U5374-000002-002BA U5354-000002-014BA U5354-000005-03KPA U5374-000005-03KPA U5354-000002-001BG U5374-000002-014BA U5374-000005-0015PG U5374-000005-200PA U5354-000005-015PG U5374-000002-001BG