103
Surface-mount Fuses Telecom Fuses
11
The telecom FT600 fuse helps telecommunications
equipment manufacturers comply with North American
overcurrent protection requirements, including Telcordia
GR-1089, TIA-968-A (formerly FCC Part 68), and
UL60950 3rd edition.
TE Circuit Protection’s telecom fuses offer low
temperature-rise performance under sneak current fault
events to help prevent damage to circuit traces or
multilayer boards, and their low profile and small
footprint make them suitable for high-density and
space-constrained applications.
High density placement in multi-port system designs
Improved temperature rise performance over other
similar surface-mount fuse devices under sneak
current testing
The FT600, in conjunction with a thyristor surge
suppression device, assists designers to meet
regulatory standards without additional series
components
Lead free materials and RoHS compliant
Halogen free
(refers to: Br900ppm, Cl900ppm, Br+Cl1500ppm)
Low profile and small footprint
The lightning robust surface-mount fuse offers
overcurrent protection in case of power fault events
Enables the design of equipment complying with
applicable telecom specifications including
UL60950, TIA-968-A, and Telcordia GR-1089
Low resistance
ADSL, ADSL2, ADSL2plus, SHDSL, VDSL linecards and modems
T1/E1 systems
Twisted-pair telecom ports requiring Telcordia GR-1089, UL60950 and FCC Part TIA-968-A compliance
Benefits Features
Applications
Surface-mount Fuses
Telecom Fuses
104 RoHS Compliant, ELV Compliant HF Halogen Free
11
Protection Application Guide for Telecommunications and Networking Devices
Customer premises equipment, IT equipment UL 60950 FT600-0500 FT600-2000
Analog modems, V.90 modems, TIA-968-A FT600-1250
ISDN modems, xDSL modems,
ADSL splitters, phone sets, fax machines,
answering machines, caller ID, internet
appliances, PBX systems, POS terminals, wall plugs
Access network equipment Telcordia GR-1089 FT600-1250 FT600-2000
Remote terminals, line repeaters, multiplexers, TIA-968-A
cross-connects, WAN equipment
Central office switching equipment Telcordia GR-1089 FT600-1250 FT600-2000
Analog/POTS linecards, ISDN linecards, xDSL modems, TIA-968-A
ADSL/VDSL splitters, T1/E1 linecards,
multiplexers, CSU/DSU, servers
Note : This list is not exhaustive.TE Circuit Protection welcomes our customers’ input for additional application ideas for overcurrent protection of telecom applications.
Application Specification
Faster Cooler Surface
Time-To-Open Temperature
To use this guide, follow the steps below:
1. Select your equipment type from the guide below.
2. Use the Key Device Selection Criteria (time-to-open, surface temperature) to determine best suitability for your application.
3. Use Agency Specification / Selection Guide to select a specific part number for each application based on the agency requirements.
Agency Specification/Selection Guide for FT600 Devices
Family Product Lightning Power Cross
FT600 FT600-0500 TIA-968-A Types A & B UL60950, 3rd Ed. 600VAC, 40A
FT600-1250 Telcordia GR-1089 Level 1 and 2 Telcordia GR-1089 600 VAC, 40A
FT600-2000 TIA-968-A UL60950
Use the guide below to select FT600 devices appropriate for use in your application. The following pages contain specifications for part
numbers recommended below. FT600 devices enable telecommunication equipment to meet the applicable protection requirements of
these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics. Users should
independently evaluate the suitability of, and test each product for their application.
FT600-0500 0.50 250 0.50 1
FT600-1250 1.25 250 0.10 16
FT600-2000 2.00 250 0.05 18
Part Number
Ampere Rating
(A)
Voltage Rating
(V)
Typical Resistance
()
Typical I2t
(A2s)*
130
120
110
10 0
90
80
70
-70 -50 -30 -10 10 30 50 70 90 110 130
Ambient Temperature ˚C
% of Current Rating
Notes: FT600-1250 and FT600-2000 assist equipment in complying with Telcordia GR-1089 specifications. In-circuit testing is strongly recommended.
The FT600-0500, FT600-1250 and FT600-2000 help meet the UL60950 Power Cross and FCC TIA-968-A 68 lightning surge requirements. Note that Type A tests allow for an
overcurrent protection component to fuse open during the surge.
Note: The FT600-xxxx devices carry 100% of rated current for 4 hours minimum and 250% of rated current for 1 second minimum, 120 seconds maximum.
Resistance measured at 10% of rated current.
*I2t is calculated at 10 ms or less.
Key Device Selection Criteria
Table FT1 Interrupt Voltage and Current Ratings for FT600 Devices
Figure FT1 Thermal Derating Curve (Normalized) for FT600 Devices
105
Surface-mount Fuses Telecom Fuses
RoHS Compliant, ELV Compliant HF Halogen Free
11
10 0
10
1
0.1
0.01
0.001
0.1 1 10 1001000
Current in Amperes
Time (sec)
ABC
0.500A 1.25A 2A
Figure FT3
FT600-0500 10.2 3.1 3.1 FT2
(0.402) (0.122) (0.122)
FT600-1250 10.2 3.1 3.1 FT2
(0.402) (0.122) (0.122)
FT600-2000 10.2 3.1 3.1 FT2
(0.402) (0.122) (0.122)
C
Min. Max.
B
Min. Max.
A
Min. Max.Part Number Figure
FT600
A=FT600-0500
B=FT600-1250
C=FT600-2000
AC
B
Table FT2 Dimensions for FT600 Devices in Millimeters (Inches)
Figure FT2 Dimension Figures for FT600 Devices
Figure FT3 Typical Time-to-open Characteristics (at 20°C) for FT600 Devices
106 RoHS Compliant, ELV Compliant HF Halogen Free
11
Physical Characteristics
Terminal material Silver-plated brass*
Body material Ceramic
Termination solderability Per IEC-60127-4
*FT600 devices use high Pb content solder for internal construction. They are RoHS compliant.
Environmental Specifications
Test Conditions
Solder heat withstand Per MIL-STD-202, Method 210, Test Condition J
Solvent resistance Per MIL-STD-202F, Method 215J
Storage temperature 30°C/ 85% RH
Storage humidity Per MIL-STD-202F, Method 106F
FT600-0500-2 2,500 10,000 500 UL, CSA
FT600-1250-2 2,500 10,000 1250 UL, CSA
FT600-2000-2 2,500 10,000 2000 UL, CSA
Note: The -2 designates tape and reel, the package style for this product.
Device AB C DFigure for Dimensions
FT600-0500 12.6 4.0 3.7 5.2 FT4
(0.496) (0.157) (0.145) (0.204)
FT600-1250 12.6 4.0 3.7 5.2 FT4
(0.496) (0.157) (0.145) (0.204)
FT600-2000 12.6 4.0 3.7 5.2 FT4
(0.496) (0.157) (0.145) (0.204)
Solder Reflow and Rework Recommendations for FT600 Devices
Solder Reflow
Recommended reflow methods: IR, vapor phase oven, hot air oven
Devices can be cleaned using standard industry methods and solvents
Rework
If a device is removed from the board, it should be discarded and
replaced by a new device
Preheating Soldering Cooling
300
250
200
150
10 0
50
0
30-90 120
10 to 20
Temperature (˚C)
Time (s)
Figure FT5
A
DC
B
Figure FT4
Part Number
Bag
Quantity
Tape & Reel
Quantity
Standard Package
Quantity Part Marking Agency Recognition
Table FT3 Physical Characteristics and Environmental Specifications for FT600 Devices
Table FT4 Packaging and Marking Information for FT600 Devices
Table FT5 Recommended Pad Layouts for FT600 Devices in Millimeters (Inches) Nominal
107
Surface-mount Fuses Telecom Fuses
RoHS Compliant, ELV Compliant HF Halogen Free
11
Table FT6 Tape and Reel Specifications for FT600 Devices
Dimension
Description EIA Mark Dimension (mm) Tolerance
Carrier tape width W 24 ±0.3
Sprocket hole pitch P04 ±0.1
P18 ±0.1
P22 ±0.1
A03.68 ±0.1
B010.44 ±0.1
Sprocket hole diameter D01.5 +0.1 / -0.0
F 11.5 ±0.1
E11.75 ±0.1
Tape thickness T max. 0.3 ±0.05
K03.25 +1.0 / -0.05
Reel Dimensions
Reel diameter A max. 331.5
Core diameter N min. 98.5
Space between flanges less devices W025 ±0.5
Reel width W1max. 31
P0Note 1
A0
P1
A
A
D0
P2Note 6
E1
W
B0
K0
T
FNote 6
AN
W1
W0
See “Detail A
Detail A
ø13.2±0.2
(0.52±0.008)
17.2±0.2
(0.677±0.008)
2.2±0.2
(0.087±0.008)
120°
Figure FT6 EIA Referenced Taped Component Dimensions for FT600 Devices
Figure FT7 EIA Referenced Reel Dimensions for FT600 Devices
Notes:
1. 10 sprocket hole pitch cumulative tolerance ±0.2
2. Allowable camber to be 1mm/250mm
3. Material: Black conductive
4. A0and B0measured on a plane 0.3mm above the
bottom of the pocket
5. K0measured from the plane on the inside bottom
of the pocket to the top surface of the carrier
6. Pocket position relative to sprocket hole measured
as true position of pocket, not pocket hole
7. Quantity per reel to be 174m
108 RoHS Compliant, ELV Compliant HF Halogen Free
11
Part Numbering System for FT600 Devices
FT 600 - 1250 -2
Packaging
-2 = Tape and Reel
Current in Amperes
1250 = 1. 25
0500 = 0.500
2000 = 2.00
Voltage Rating
Product Family
Warning :
All information, including illustrations, is believed to be accurate and reliable. Users, however, should independently evaluate the suitability of and
test each product selected for their application. Tyco Electronics Corporation and/or its Affiliates in the TE Connectivity Ltd. family of companies
(“TE”) makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use.TE’s only obligations
are those in the TE Standard Terms and Conditions of Sale for this product, and in no case will TE be liable for any incidental, indirect, or
consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In
addition,TE reserves the right to make changes to materials or processing that do not affect compliance with any applicable specification without
notification to Buyer.