4" x 1" Fuses 1 AGX Series, Fast-Acting, Glass Tube Description * Fast-acting glass tube fuse * 14" x 1" (6.3 x 25.4mm) physical size * Glass tube, nickel-plated brass endcap construction * For instruments, electronic and small appliance circuits * UL Listed product meets standard 248-14 * Available with axial leads Rated Current 16 - 30A 1 16 - 2A 2.5 - 30A 1 Electrical Characteristics % of Amp Rating Opening Time 110% 4 hours minimum 135% 60 minutes maximum 200% 5 seconds maximum 200% 2 minutes maximum Dimensions - mm (in) Agency Information * UL Listed Card: AGX 0-5A (Guide JDYX, File E19180) * UL Recognized Card: AGX 6-20A (Guide JDYX2, File E19180) * CSA Component Acceptance Card (Class No. 1422-01, File 53787) Ordering * Specify packaging, product, and option code with axial leads Specifications Part Number -(amps) AGX-1/200 AGX-1/100 AGX-1/32 AGX-1/16 AGX-1/10 AGX-1/8 AGX-3/16 AGX-2/10 AGX-1/4 AGX-3/10 AGX-3/8 AGX-4/10 AGX-1/2 AGX-3/4 AGX-1 AGX-1-1/4 AGX-1-1/2 AGX-2 AGX-2-1/2 AGX-3 AGX-4 AGX-5 AGX-6 AGX-7 AGX-8 AGX-10 AGX-15 AGX-20 AGX-25 AGX-30 Voltage Rating Vac 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 125 125 125 125 125 125 32 32 32 32 32 32 Interrupting Rating (amps) 250Vac 125Vac 32Vac 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 100 10,000 100 10,000 100 10,000 100 10,000 100 10,000 10,000 10,000 10,000 10,000 1000 1000 1000 1000 1000 1000 1000 1000 Typical DC Cold Resistance ()* 285.00000 155.00000 35.00000 22.50000 10.25000 5.41000 3.11500 2.66000 2.79000 1.42500 0.93050 0.89900 0.47850 0.26000 0.16250 0.12750 0.09400 0.06825 0.04930 0.03825 0.02700 0.02050 0.01475 0.01275 0.01100 0.00867 0.00510 0.00358 0.00275 0.00215 * DC Cold Resistance (Measured at <10% of rated current) 0308 BU-SB08027 Page 1 of 2 Data Sheet 2041 Time-Current Curve 5 2 1 1/4 CURRENT IN AMP ERES TIME IN SECONDS TIME IN SECONDS CURRENT IN AMP ERES Packaging Packaging Code Prefix BK Description 100 fuses packed into a cardboard carton Option Code Option Code Suffix V Description Axial leads - copper tinned wire with nickel plated brass overcaps The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. (c) 2008 Cooper Bussmann St. Louis, MO 63178 www.cooperbussmann.com 0308 BU-SB08027 Page 2 of 2 Data Sheet 2041