Features
Single 2.7V - 3.6V Supply
Serial Peripheral Interface (SPI) Compatible
Supports SPI Modes 0 and 3
Supports RapidS Operation
Supports Dual-Input Program and Dual-Output Read
Very High Operating Frequencies
100MHz for RapidS
85MHz for SPI
Clock-to-Output (tV) of 5ns Maximum
Flexible, Optimized Erase Architecture for Code + Data Storage Applications
Uniform 4-Kbyte Block Erase
Uniform 32-Kbyte Block Erase
Uniform 64-Kbyte Block Erase
Full Chip Erase
Individual Sector Protection with Global Protect/Unprotect Feature
16 Sectors of 64-Kbytes Each
Hardware Controlled Locking of Protected Sectors via WP Pin
Sector Lockdown
Make Any Combination of 64-Kbyte Sectors Permanently Read-Only
128-Byte Programmable OTP Security Register
Flexible Programming
Byte/Page Program (1- to 256-Bytes)
Fast Program and Erase Times
1.0ms Typical Page Program (256 Bytes) Time
50ms Typical 4-Kbyte Block Erase Time
250ms Typical 32-Kbyte Block Erase Time
400ms Typical 64-Kbyte Block Erase Time
Automatic Checking and Reporting of Erase/Program Failures
Software Controlled Reset
JEDEC Standard Manufacturer and Device ID Read Methodology
Low Power Dissipation
5mA Active Read Current (Typical at 20MHz)
5µA Deep Power-Down Current (Typical)
Endurance: 100,000 Program/Erase Cycles
Data Retention: 20 Years
Complies with Full Industrial Temperature Range
Industry Standard Green (Pb/Halide-free/RoHS Compliant) Package Options
8-lead SOIC (150-mil and 208-mil wide)
8-pad Ultra Thin DFN (5 x 6 x 0.6mm)
8-Mbit
2.7V Minimum
SPI Serial Flash
Memory
AT25DF081A
8715E–SFLSH–11/2017
2
8715E–SFLSH–11/2017
AT25DF081A
1. Description
The Adesto® AT25DF081A is a serial interface Flash memory device designed for use in a wide variety of high-vol-
ume consumer based applications in which program code is shadowed from Flash memory into embedded or
external RAM for execution. The flexible erase architecture of the AT25DF081A, with its erase granularity as small
as 4-Kbytes, makes it ideal for data storage as well, eliminating the need for additional data storage EEPROM
devices.
The physical sectoring and the erase block sizes of the AT25DF081A have been optimized to meet the needs of
today's code and data storage applications. By optimizing the size of the physical sectors and erase blocks, the
memory space can be used much more efficiently. Because certain code modules and data storage segments
must reside by themselves in their own protected sectors, the wasted and unused memory space that occurs with
large sectored and large block erase Flash memory devices can be greatly reduced. This increased memory space
efficiency allows additional code routines and data storage segments to be added while still maintaining the same
overall device density.
The AT25DF081A also offers a sophisticated method for protecting individual sectors against erroneous or mali-
cious program and erase operations. By providing the ability to individually protect and unprotect sectors, a system
can unprotect a specific sector to modify its contents while keeping the remaining sectors of the memory array
securely protected. This is useful in applications where program code is patched or updated on a subroutine or
module basis, or in applications where data storage segments need to be modified without running the risk of
errant modifications to the program code segments. In addition to individual sector protection capabilities, the
AT25DF081A incorporates Global Protect and Global Unprotect features that allow the entire memory array to be
either protected or unprotected all at once. This reduces overhead during the manufacturing process since sectors
do not have to be unprotected one-by-one prior to initial programming.
To take code and data protection to the next level, the AT25DF081A incorporates a sector lockdown mechanism
that allows any combination of individual 64-Kbyte sectors to be locked down and become permanently read-only.
This addresses the need of certain secure applications that require portions of the Flash memory array to be per-
manently protected against malicious attempts at altering program code, data modules, security information, or
encryption/decryption algorithms, keys, and routines. The device also contains a specialized OTP (One-Time Pro-
grammable) Security Register that can be used for purposes such as unique device serialization, system-level
Electronic Serial Number (ESN) storage, locked key storage, etc.
Specifically designed for use in 3-volt systems, the AT25DF081A supports read, program, and erase operations
with a supply voltage range of 2.7V to 3.6V. No separate voltage is required for programming and erasing.
3
8715E–SFLSH–11/2017
AT25DF081A
2. Pin Descriptions and Pinouts
Table 2-1. Pin Descriptions
Symbol Name and Function
Asserted
State Type
CS
CHIP SELECT: Asserting the CS pin selects the device. When the CS pin is deasserted, the
device will be deselected and normally be placed in standby mode (not Deep Power-Down
mode), and the SO pin will be in a high-impedance state. When the device is deselected,
data will not be accepted on the SI pin.
A high-to-low transition on the CS pin is required to start an operation, and a low-to-high
transition is required to end an operation. When ending an internally self-timed operation
such as a program or erase cycle, the device will not enter the standby mode until the
completion of the operation.
Low Input
SCK
SERIAL CLOCK: This pin is used to provide a clock to the device and is used to control the
flow of data to and from the device. Command, address, and input data present on the SI pin
is always latched in on the rising edge of SCK, while output data on the SO pin is always
clocked out on the falling edge of SCK.
- Input
SI (SIO)
SERIAL INPUT (SERIAL INPUT/OUTPUT): The SI pin is used to shift data into the device.
The SI pin is used for all data input including command and address sequences. Data on the
SI pin is always latched in on the rising edge of SCK.
With the Dual-Output Read Array command, the SI pin becomes an output pin (SIO) to allow
two bits of data (on the SO and SIO pins) to be clocked out on every falling edge of SCK. To
maintain consistency with SPI nomenclature, the SIO pin will be referenced as SI throughout
the document with exception to sections dealing with the Dual-Output Read Array command
in which it will be referenced as SIO.
Data present on the SI pin will be ignored whenever the device is deselected (CS is
deasserted).
- Input/Output
SO (SOI)
SERIAL OUTPUT (SERIAL OUTPUT/INPUT): The SO pin is used to shift data out from the
device. Data on the SO pin is always clocked out on the falling edge of SCK.
With the Dual-Input Byte/Page Program command, the SO pin becomes an input pin (SOI)
to allow two bits of data (on the SOI and SI pins) to be clocked in on every rising edge of
SCK. To maintain consistency with SPI nomenclature, the SOI pin will be referenced as SO
throughout the document with exception to sections dealing with the Dual-Input Byte/Page
Program command in which it will be referenced as SOI.
The SO pin will be in a high-impedance state whenever the device is deselected (CS is
deasserted).
- Output/Input
WP
WRITE PROTECT: The WP pin controls the hardware locking feature of the device. Please
refer to “Protection Commands and Features” on page 17 for more details on protection
features and the WP pin.
The WP pin is internally pulled-high and may be left floating if hardware controlled protection
will not be used. However, it is recommended that the WP pin also be externally connected
to VCC whenever possible.
Low Input
HOLD
HOLD: The HOLD pin is used to temporarily pause serial communication without
deselecting or resetting the device. While the HOLD pin is asserted, transitions on the SCK
pin and data on the SI pin will be ignored, and the SO pin will be in a high-impedance state.
The CS pin must be asserted, and the SCK pin must be in the low state in order for a Hold
condition to start. A Hold condition pauses serial communication only and does not have an
effect on internally self-timed operations such as a program or erase cycle. Please refer to
“Hold” on page 41 for additional details on the Hold operation.
The HOLD pin is internally pulled-high and may be left floating if the Hold function will not be
used. However, it is recommended that the HOLD pin also be externally connected to VCC
whenever possible.
Low Input
4
8715E–SFLSH–11/2017
AT25DF081A
3. Block Diagram
Figure 3-1. Block Diagram
VCC
DEVICE POWER SUPPLY: The VCC pin is used to supply the source voltage to the device.
Operations at invalid VCC voltages may produce spurious results and should not be
attempted.
-Power
GND GROUND: The ground reference for the power supply. GND should be connected to the
system ground. -Power
Table 2-1. Pin Descriptions (Continued)
Symbol Name and Function
Asserted
State Type
Figure 2-1. 8-SOIC (Top View) Figure 2-2. 8-UDFN (Top View)
CS
SO (SOI)
WP
GND
1
2
3
4
8
7
6
5
VCC
HOLD
SCK
SI (SIO)
CS
SO (SOI)
WP
GND
1
2
3
4
8
7
6
5
VCC
HOLD
SCK
SI (SIO)
FLASH
MEMORY
ARRAY
Y-GATING
CS
SCK
SO (SOI)
SI (SIO)
Y-DECODER
ADDRESS LATCH
X-DECODER
I/O BUFFERS
AND LATCHES
CONTROL AND
PROTECTION LOGIC
SRAM
DATA BUFFER
WP
INTERFACE
CONTROL
AND
LOGIC
HOLD
5
8715E–SFLSH–11/2017
AT25DF081A
4. Memory Array
To provide the greatest flexibility, the memory array of the AT25DF081A can be erased in four levels of granularity
including a full chip erase. In addition, the array has been divided into physical sectors of uniform size, of which
each sector can be individually protected from program and erase operations. The size of the physical sectors is
optimized for both code and data storage applications, allowing both code and data segments to reside in their own
isolated regions. The Memory Architecture Diagram illustrates the breakdown of each erase level as well as the
breakdown of each physical sector.
Figure 4-1. Memory Architecture Diagram
Internal Sectoring fo
r
64KB 32KB 4KB 1-256 Byte
Sector Protection Block Erase Block Erase Block Erase Page Program
Function (D8h Command) (52h Command) (20h Command) (02h Command)
4KB 0FFFFFh 0FF000h 256 Bytes 0FFFFFh 0FFF00h
4KB 0FEFFFh 0FE000h 256 Bytes 0FFEFFh 0FFE00h
4KB 0FDFFFh 0FD000h 256 Bytes 0FFDFFh 0FFD00h
4KB 0FCFFFh 0FC000h 256 Bytes 0FFCFFh 0FFC00h
4KB 0FBFFFh 0FB000h 256 Bytes 0FFBFFh 0FFB00h
4KB 0FAFFFh 0FA000h 256 Bytes 0FFAFFh 0FFA00h
4KB 0F9FFFh 0F9000h 256 Bytes 0FF9FFh 0FF900h
4KB 0F8FFFh 0F8000h 256 Bytes 0FF8FFh 0FF800h
4KB 0F7FFFh 0F7000h 256 Bytes 0FF7FFh 0FF700h
4KB 0F6FFFh 0F6000h 256 Bytes 0FF6FFh 0FF600h
4KB 0F5FFFh 0F5000h 256 Bytes 0FF5FFh 0FF500h
4KB 0F4FFFh 0F4000h 256 Bytes 0FF4FFh 0FF400h
4KB 0F3FFFh 0F3000h 256 Bytes 0FF3FFh 0FF300h
4KB 0F2FFFh 0F2000h 256 Bytes 0FF2FFh 0FF200h
4KB 0F1FFFh 0F1000h 256 Bytes 0FF1FFh 0FF100h
4KB 0F0FFFh 0F0000h 256 Bytes 0FF0FFh 0FF000h
4KB 0EFFFFh 0EF000h 256 Bytes 0FEFFFh 0FEF00h
4KB 0EEFFFh 0EE000h 256 Bytes 0FEEFFh 0FEE00h
4KB 0EDFFFh 0ED000h 256 Bytes 0FEDFFh 0FED00h
4KB 0ECFFFh 0EC000h 256 Bytes 0FECFFh 0FEC00h
4KB 0EBFFFh 0EB000h 256 Bytes 0FEBFFh 0FEB00h
4KB 0EAFFFh 0EA000h 256 Bytes 0FEAFFh 0FEA00h
4KB 0E9FFFh 0E9000h 256 Bytes 0FE9FFh 0FE900h
4KB 0E8FFFh 0E8000h 256 Bytes 0FE8FFh 0FE800h
4KB 0E7FFFh 0E7000h
4KB 0E6FFFh 0E6000h
4KB 0E5FFFh 0E5000h
4KB 0E4FFFh 0E4000h 256 Bytes 0017FFh 001700h
4KB 0E3FFFh 0E3000h 256 Bytes 0016FFh 001600h
4KB 0E2FFFh 0E2000h 256 Bytes 0015FFh 001500h
4KB 0E1FFFh 0E1000h 256 Bytes 0014FFh 001400h
4KB 0E0FFFh 0E0000h 256 Bytes 0013FFh 001300h
256 Bytes 0012FFh 001200h
256 Bytes 0011FFh 001100h
256 Bytes 0010FFh 001000h
4KB 00FFFFh 00F000h 256 Bytes 000FFFh 000F00h
4KB 00EFFFh 00E000h 256 Bytes 000EFFh 000E00h
4KB 00DFFFh 00D000h 256 Bytes 000DFFh 000D00h
4KB 00CFFFh 00C000h 256 Bytes 000CFFh 000C00h
4KB 00BFFFh 00B000h 256 Bytes 000BFFh 000B00h
4KB 00AFFFh 00A000h 256 Bytes 000AFFh 000A00h
4KB 009FFFh 009000h 256 Bytes 0009FFh 000900h
4KB 008FFFh 008000h 256 Bytes 0008FFh 000800h
4KB 007FFFh 007000h 256 Bytes 0007FFh 000700h
4KB 006FFFh 006000h 256 Bytes 0006FFh 000600h
4KB 005FFFh 005000h 256 Bytes 0005FFh 000500h
4KB 004FFFh 004000h 256 Bytes 0004FFh 000400h
4KB 003FFFh 003000h 256 Bytes 0003FFh 000300h
4KB 002FFFh 002000h 256 Bytes 0002FFh 000200h
4KB 001FFFh 001000h 256 Bytes 0001FFh 000100h
4KB 000FFFh 000000h 256 Bytes 0000FFh 000000h
64KB
Block Erase Detail Page Program Detail
Page AddressBlock Address
32KB
32KB
64KB
(Sector 0)
Range
Range
32KB
32KB
64KB
(Sector 15) 64KB
32KB
32KB
64KB
(Sector 14) 64KB
6
8715E–SFLSH–11/2017
AT25DF081A
5. Device Operation
The AT25DF081A is controlled by a set of instructions that are sent from a host controller, commonly referred to as
the SPI Master. The SPI Master communicates with the AT25DF081A via the SPI bus which is comprised of four
signal lines: Chip Select (CS), Serial Clock (SCK), Serial Input (SI), and Serial Output (SO).
The AT25DF081A features a dual-input program mode in which the SO pin becomes an input. Similarly, the device
also features a dual-output read mode in which the SI pin becomes an output. In the Dual-Input Byte/Page Pro-
gram command description, the SO pin will be referred to as the SOI (Serial Output/Input) pin, and in the Dual-
Output Read Array command, the SI pin will be referenced as the SIO (Serial Input/Output) pin.
The SPI protocol defines a total of four modes of operation (mode 0, 1, 2, or 3) with each mode differing in respect
to the SCK polarity and phase and how the polarity and phase control the flow of data on the SPI bus. The
AT25DF081A supports the two most common modes, SPI Modes 0 and 3. The only difference between SPI Modes
0 and 3 is the polarity of the SCK signal when in the inactive state (when the SPI Master is in standby mode and
not transferring any data). With SPI Modes 0 and 3, data is always latched in on the rising edge of SCK and
always output on the falling edge of SCK.
Figure 5-1. SPI Mode 0 and 3
6. Commands and Addressing
A valid instruction or operation must always be started by first asserting the CS pin. After the CS pin has been
asserted, the host controller must then clock out a valid 8-bit opcode on the SPI bus. Following the opcode, instruc-
tion dependent information such as address and data bytes would then be clocked out by the host controller. All
opcode, address, and data bytes are transferred with the most-significant bit (MSB) first. An operation is ended by
deasserting the CS pin.
Opcodes not supported by the AT25DF081A will be ignored by the device and no operation will be started. The
device will continue to ignore any data presented on the SI pin until the start of the next operation (CS pin being
deasserted and then reasserted). In addition, if the CS pin is deasserted before complete opcode and address
information is sent to the device, then no operation will be performed and the device will simply return to the idle
state and wait for the next operation.
Addressing of the device requires a total of three bytes of information to be sent, representing address bits A23-A0.
Since the upper address limit of the AT25DF081A memory array is 0FFFFFh, address bits A23-A20 are always
ignored by the device.
SCK
CS
SI
SO
MSB LSB
MSB LSB
7
8715E–SFLSH–11/2017
AT25DF081A
Table 6-1. Command Listing
Command Opcode
Clock
Frequency
Address
Bytes
Dummy
Bytes
Data
Bytes
Read Commands
Read Array
1Bh 0001 1011 Up to 100MHz 3 2 1+
0Bh 0000 1011 Up to 85MHz 3 1 1+
03h 0000 0011 Up to 50MHz 3 0 1+
Dual-Output Read Array 3Bh 0011 1011 Up to 85MHz 3 1 1+
Program and Erase Commands
Block Erase (4 KBytes) 20h 0010 0000 Up to 100MHz 3 0 0
Block Erase (32 KBytes) 52h 0101 0010 Up to 100MHz 3 0 0
Block Erase (64 KBytes) D8h 1101 1000 Up to 100MHz 3 0 0
Chip Erase
60h 0110 0000 Up to 100MHz 0 0 0
C7h 1100 0111 Up to 100MHz 0 0 0
Byte/Page Program (1 to 256 Bytes) 02h 0000 0010 Up to 100MHz 3 0 1+
Dual-Input Byte/Page Program (1 to 256 Bytes) A2h 1010 0010 Up to 100MHz 3 0 1+
Protection Commands
Write Enable 06h 0000 0110 Up to 100MHz 0 0 0
Write Disable 04h 0000 0100 Up to 100MHz 0 0 0
Protect Sector 36h 0011 0110 Up to 100MHz 3 0 0
Unprotect Sector 39h 0011 1001 Up to 100MHz 3 0 0
Global Protect/Unprotect Use Write Status Register Byte 1 Command
Read Sector Protection Registers 3Ch 0011 1100 Up to 100MHz 3 0 1+
Security Commands
Sector Lockdown 33h 0011 0011 Up to 100MHz 3 0 1
Freeze Sector Lockdown State 34h 0011 0100 Up to 100MHz 3 0 1
Read Sector Lockdown Registers 35h 0011 0101 Up to 100MHz 3 0 1+
Program OTP Security Register 9Bh 1001 1011 Up to 100MHz 3 0 1+
Read OTP Security Register 77h 0111 0111 Up to 100MHz 3 2 1+
Status Register Commands
Read Status Register 05h 0000 0101 Up to 100MHz 0 0 1+
Write Status Register Byte 1 01h 0000 0001 Up to 100MHz 0 0 1
Write Status Register Byte 2 31h 0011 0001 Up to 100MHz 0 0 1
Miscellaneous Commands
Reset F0h 1111 0000 Up to 100MHz 0 0 1
Read Manufacturer and Device ID 9Fh 1001 1111 Up to 85MHz 0 0 1 to 4
Deep Power-Down B9h 1011 1001 Up to 100MHz 0 0 0
Resume from Deep Power-Down ABh 1010 1011 Up to 100MHz 0 0 0
8
8715E–SFLSH–11/2017
AT25DF081A
7. Read Commands
7.1 Read Array
The Read Array command can be used to sequentially read a continuous stream of data from the device by simply
providing the clock signal once the initial starting address has been specified. The device incorporates an internal
address counter that automatically increments on every clock cycle.
Three opcodes (1Bh, 0Bh, and 03h) can be used for the Read Array command. The use of each opcode depends
on the maximum clock frequency that will be used to read data from the device. The 0Bh opcode can be used at
any clock frequency up to the maximum specified by fCLK, and the 03h opcode can be used for lower frequency
read operations up to the maximum specified by fRDLF. The 1Bh opcode allows the highest read performance pos-
sible and can be used at any clock frequency up to the maximum specified by fMAX; however, use of the 1Bh
opcode at clock frequencies above fCLK should be reserved to systems employing the RapidS protocol.
To perform the Read Array operation, the CS pin must first be asserted and the appropriate opcode (1Bh, 0Bh, or
03h) must be clocked into the device. After the opcode has been clocked in, the three address bytes must be
clocked in to specify the starting address location of the first byte to read within the memory array. Following the
three address bytes, additional dummy bytes may need to be clocked into the device depending on which opcode
is used for the Read Array operation. If the 1Bh opcode is used, then two dummy bytes must be clocked into the
device after the three address bytes. If the 0Bh opcode is used, then a single dummy byte must be clocked in after
the address bytes.
After the three address bytes (and the dummy bytes or byte if using opcodes 1Bh or 0Bh) have been clocked in,
additional clock cycles will result in data being output on the SO pin. The data is always output with the MSB of a
byte first. When the last byte (0FFFFFh) of the memory array has been read, the device will continue reading back
at the beginning of the array (000000h). No delays will be incurred when wrapping around from the end of the array
to the beginning of the array.
Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS
pin can be deasserted at any time and does not require that a full byte of data be read.
Figure 7-1. Read Array – 1Bh Opcode
SCK
CS
SI
SO
MSB MSB
2310
00011011
675410119812 394243414037 3833 36353431 3229 30 44 47 484645 50 5149 52 55 565453
OPCODE
AAAA AAAA A
MSB
XXXXXXXX
MSB MSB
DDDDDDDDDD
ADDRESS BITS A23-A0 DON'T CARE
MSB
XXXXXXXX
DON'T CARE
DATA BYTE 1
HIGH-IMPEDANCE
9
8715E–SFLSH–11/2017
AT25DF081A
Figure 7-2. Read Array – 0Bh Opcode
Figure 7-3. Read Array – 03h Opcode
SCK
CS
SI
SO
MSB MSB
2310
00001011
675410119812 394243414037 3833 36353431 3229 30 44 47 484645
OPCODE
AAAA AAAA A
MSB
XXXXXXXX
MSB MSB
DDDDDDDDDD
ADDRESS BITS A23-A0 DON'T CARE
DATA BYTE 1
HIGH-IMPEDANCE
SCK
CS
SI
SO
MSB MSB
2310
00000011
675410119812 373833 36353431 3229 30 39 40
OPCODE
AAAA AAAA A
MSB MSB
DDDDDDDDDD
ADDRESS BITS A23-A0
DATA BYTE 1
HIGH-IMPEDANCE
10
8715E–SFLSH–11/2017
AT25DF081A
7.2 Dual-Output Read Array
The Dual-Output Read Array command is similar to the standard Read Array command and can be used to
sequentially read a continuous stream of data from the device by simply providing the clock signal once the initial
starting address has been specified. Unlike the standard Read Array command, however, the Dual-Output Read
Array command allows two bits of data to be clocked out of the device on every clock cycle rather than just one.
The Dual-Output Read Array command can be used at any clock frequency up to the maximum specified by fRDDO.
To perform the Dual-Output Read Array operation, the CS pin must first be asserted and the opcode of 3Bh must
be clocked into the device. After the opcode has been clocked in, the three address bytes must be clocked in to
specify the starting address location of the first byte to read within the memory array. Following the three address
bytes, a single dummy byte must also be clocked into the device.
After the three address bytes and the dummy byte have been clocked in, additional clock cycles will result in data
being output on both the SO and SIO pins. The data is always output with the MSB of a byte first, and the MSB is
always output on the SO pin. During the first clock cycle, bit seven of the first data byte will be output on the SO pin
while bit six of the same data byte will be output on the SIO pin. During the next clock cycle, bits five and four of the
first data byte will be output on the SO and SIO pins, respectively. The sequence continues with each byte of data
being output after every four clock cycles. When the last byte (0FFFFFh) of the memory array has been read, the
device will continue reading back at the beginning of the array (000000h). No delays will be incurred when wrap-
ping around from the end of the array to the beginning of the array.
Deasserting the CS pin will terminate the read operation and put the SO and SIO pins into a high-impedance state.
The CS pin can be deasserted at any time and does not require that a full byte of data be read.
Figure 7-4. Dual-Output Read Array
SCK
CS
SIO
SO
MSB MSB
2310
00111011
675410119812 394243414037 3833 36353431 3229 30 44 47 484645
OPCODE
AAAA AAAAA
MSB
XXXXXXXX
MSB MSB MSB
D7
D6
D5
D4
D3
D2
D1
D0
D7
D6
D5
D4
D7
D6
D5
D4
D3
D2
D1
D0
ADDRESS BITS A23-A0 DON'T CARE
OUTPUT
DATA BYTE 1
OUTPUT
DATA BYTE 2
HIGH-IMPEDANCE
11
8715E–SFLSH–11/2017
AT25DF081A
8. Program and Erase Commands
8.1 Byte/Page Program
The Byte/Page Program command allows anywhere from a single byte of data to 256-bytes of data to be pro-
grammed into previously erased memory locations. An erased memory location is one that has all eight bits set to
the logical “1” state (a byte value of FFh). Before a Byte/Page Program command can be started, the Write Enable
command must have been previously issued to the device (see “Write Enable” on page 17) to set the Write Enable
Latch (WEL) bit of the Status Register to a logical “1” state.
To perform a Byte/Page Program command, an opcode of 02h must be clocked into the device followed by the
three address bytes denoting the first byte location of the memory array to begin programming at. After the address
bytes have been clocked in, data can then be clocked into the device and will be stored in an internal buffer.
If the starting memory address denoted by A23-A0 does not fall on an even 256-byte page boundary (A7-A0 are
not all 0), then special circumstances regarding which memory locations to be programmed will apply. In this situa-
tion, any data that is sent to the device that goes beyond the end of the page will wrap around back to the
beginning of the same page. For example, if the starting address denoted by A23-A0 is 0000FEh, and three bytes
of data are sent to the device, then the first two bytes of data will be programmed at addresses 0000FEh and
0000FFh while the last byte of data will be programmed at address 000000h. The remaining bytes in the page
(addresses 000001h through 0000FDh) will not be programmed and will remain in the erased state (FFh). In addi-
tion, if more than 256-bytes of data are sent to the device, then only the last 256-bytes sent will be latched into the
internal buffer.
When the CS pin is deasserted, the device will take the data stored in the internal buffer and program it into the
appropriate memory array locations based on the starting address specified by A23-A0 and the number of data
bytes sent to the device. If less than 256-bytes of data were sent to the device, then the remaining bytes within the
page will not be programmed and will remain in the erased state (FFh). The programming of the data bytes is inter-
nally self-timed and should take place in a time of tPP or tBP if only programming a single byte.
The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin
is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the
device will abort the operation and no data will be programmed into the memory array. In addition, if the address
specified by A23-A0 points to a memory location within a sector that is in the protected state (see “Protect Sector”
on page 19) or locked down (see “Sector Lockdown” on page 25), then the Byte/Page Program command will not
be executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the
Status Register will be reset back to the logical “0” state if the program cycle aborts due to an incomplete address
being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or
because the memory location to be programmed is protected or locked down.
While the device is programming, the Status Register can be read and will indicate that the device is busy. For
faster throughput, it is recommended that the Status Register be polled rather than waiting the tBP or tPP time to
determine if the data bytes have finished programming. At some point before the program cycle completes, the
WEL bit in the Status Register will be reset back to the logical “0” state.
The device also incorporates an intelligent programming algorithm that can detect when a byte location fails to pro-
gram properly. If a programming error arises, it will be indicated by the EPE bit in the Status Register.
12
8715E–SFLSH–11/2017
AT25DF081A
Figure 8-1. Byte Program
Figure 8-2. Page Program
SCK
CS
SI
SO
MSB MSB
2310
00000010
675410119812 3937 3833 36353431 3229 30
OPCODE
HIGH-IMPEDANCE
AAAA AAAA A
MSB
DDDDDDDD
ADDRESS BITS A23-A0 DATA IN
13
8715E–SFLSH–11/2017
AT25DF081A
8.2 Dual-Input Byte/Page Program
The Dual-Input Byte/Page Program command is similar to the standard Byte/Page Program command and can be
used to program anywhere from a single byte of data up to 256-bytes of data into previously erased memory loca-
tions. Unlike the standard Byte/Page Program command, however, the Dual-Input Byte/Page Program command
allows two bits of data to be clocked into the device on every clock cycle rather than just one.
Before the Dual-Input Byte/Page Program command can be started, the Write Enable command must have been
previously issued to the device (see “Write Enable” on page 17) to set the Write Enable Latch (WEL) bit of the Sta-
tus Register to a logical “1” state. To perform a Dual-Input Byte/Page Program command, an opcode of A2h must
be clocked into the device followed by the three address bytes denoting the first byte location of the memory array
to begin programming at. After the address bytes have been clocked in, data can then be clocked into the device
two bits at a time on both the SOI and SI pins.
The data is always input with the MSB of a byte first, and the MSB is always input on the SOI pin. During the first
clock cycle, bit seven of the first data byte would be input on the SOI pin while bit six of the same data byte would
be input on the SI pin. During the next clock cycle, bits five and four of the first data byte would be input on the SOI
and SI pins, respectively. The sequence would continue with each byte of data being input after every four clock
cycles. Like the standard Byte/Page Program command, all data clocked into the device is stored in an internal
buffer.
If the starting memory address denoted by A23-A0 does not fall on an even 256-byte page boundary (A7-A0 are
not all 0), then special circumstances regarding which memory locations to be programmed will apply. In this situa-
tion, any data that is sent to the device that goes beyond the end of the page will wrap around back to the
beginning of the same page. For example, if the starting address denoted by A23-A0 is 0000FEh, and three bytes
of data are sent to the device, then the first two bytes of data will be programmed at addresses 0000FEh and
0000FFh while the last byte of data will be programmed at address 000000h. The remaining bytes in the page
(addresses 000001h through 0000FDh) will not be programmed and will remain in the erased state (FFh). In addi-
tion, if more than 256-bytes of data are sent to the device, then only the last 256-bytes sent will be latched into the
internal buffer.
When the CS pin is deasserted, the device will take the data stored in the internal buffer and program it into the
appropriate memory array locations based on the starting address specified by A23-A0 and the number of data
bytes sent to the device. If less than 256-bytes of data were sent to the device, then the remaining bytes within the
page will not be programmed and will remain in the erased state (FFh). The programming of the data bytes is inter-
nally self-timed and should take place in a time of tPP or tBP if only programming a single byte.
The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin
is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the
device will abort the operation and no data will be programmed into the memory array. In addition, if the address
specified by A23-A0 points to a memory location within a sector that is in the protected state (see “Protect Sector”
on page 19) or locked down (see “Sector Lockdown” on page 25), then the Byte/Page Program command will not
be executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the
Status Register will be reset back to the logical “0” state if the program cycle aborts due to an incomplete address
being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or
because the memory location to be programmed is protected or locked down.
While the device is programming, the Status Register can be read and will indicate that the device is busy. For
faster throughput, it is recommended that the Status Register be polled rather than waiting the tBP or tPP time to
determine if the data bytes have finished programming. At some point before the program cycle completes, the
WEL bit in the Status Register will be reset back to the logical “0” state.
The device also incorporates an intelligent programming algorithm that can detect when a byte location fails to pro-
gram properly. If a programming error arises, it will be indicated by the EPE bit in the Status Register.
14
8715E–SFLSH–11/2017
AT25DF081A
Figure 8-3. Dual-Input Byte Program
Figure 8-4. Dual-Input Page Program
SCK
CS
SI
SOI
MSB MSB
2310
10100010
675410119812 33353431 3229 30
OPCODE
AAAA AAAA A
ADDRESS BITS A23-A0
MSB
D7
D6
D5
D4
D3
D2
D1
D0
INPUT
DATA BYTE
HIGH-IMPEDANCE
SCK
CS
SI
SOI
MSB MSB
2310
10100010
675410119812 3937 3833 36353431 3229 30
OPCODE
AAAA AAAA A
MSB MSB
D7
D6
D5
D4
D3
D2
D1
D0
D7
D6
D5
D4
D3
D2
D1
D0
ADDRESS BITS A23-A0
INPUT
DATA BYTE 1
MSB
D7
D6
D5
D4
D3
D2
D1
D0
INPUT
DATA BYTE n
INPUT
DATA BYTE 2
HIGH-IMPEDANCE
15
8715E–SFLSH–11/2017
AT25DF081A
8.3 Block Erase
A block of 4-, 32-, or 64-Kbytes can be erased (all bits set to the logical “1” state) in a single operation by using one
of three different opcodes for the Block Erase command. An opcode of 20h is used for a 4-Kbyte erase, an opcode
of 52h is used for a 32-Kbyte erase, and an opcode of D8h is used for a 64-Kbyte erase. Before a Block Erase
command can be started, the Write Enable command must have been previously issued to the device to set the
WEL bit of the Status Register to a logical “1” state.
To perform a Block Erase, the CS pin must first be asserted and the appropriate opcode (20h, 52h, or D8h) must
be clocked into the device. After the opcode has been clocked in, the three address bytes specifying an address
within the 4-, 32-, or 64-Kbyte block to be erased must be clocked in. Any additional data clocked into the device
will be ignored. When the CS pin is deasserted, the device will erase the appropriate block. The erasing of the
block is internally self-timed and should take place in a time of tBLKE.
Since the Block Erase command erases a region of bytes, the lower order address bits do not need to be decoded
by the device. Therefore, for a 4-Kbyte erase, address bits A11-A0 will be ignored by the device and their values
can be either a logical “1” or “0”. For a 32-Kbyte erase, address bits A14-A0 will be ignored, and for a 64-Kbyte
erase, address bits A15-A0 will be ignored by the device. Despite the lower order address bits not being decoded
by the device, the complete three address bytes must still be clocked into the device before the CS pin is deas-
serted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the
device will abort the operation and no erase operation will be performed.
If the address specified by A23-A0 points to a memory location within a sector that is in the protected or locked
down state, then the Block Erase command will not be executed, and the device will return to the idle state once
the CS pin has been deasserted.
The WEL bit in the Status Register will be reset back to the logical “0” state if the erase cycle aborts due to an
incomplete address being sent, the CS pin being deasserted on uneven byte boundaries, or because a memory
location within the region to be erased is protected or locked down.
While the device is executing a successful erase cycle, the Status Register can be read and will indicate that the
device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the
tBLKE time to determine if the device has finished erasing. At some point before the erase cycle completes, the WEL
bit in the Status Register will be reset back to the logical “0” state.
The device also incorporates an intelligent erase algorithm that can detect when a byte location fails to erase prop-
erly. If an erase error occurs, it will be indicated by the EPE bit in the Status Register.
Figure 8-5. Block Erase
SCK
CS
SI
SO
MSB MSB
2310
CCCCCCCC
675410119812 3129 3027 2826
OPCODE
AAAA AAAA A A A A
ADDRESS BITS A23-A0
HIGH-IMPEDANCE
16
8715E–SFLSH–11/2017
AT25DF081A
8.4 Chip Erase
The entire memory array can be erased in a single operation by using the Chip Erase command. Before a Chip
Erase command can be started, the Write Enable command must have been previously issued to the device to set
the WEL bit of the Status Register to a logical “1” state.
Two opcodes, 60h and C7h, can be used for the Chip Erase command. There is no difference in device functional-
ity when utilizing the two opcodes, so they can be used interchangeably. To perform a Chip Erase, one of the two
opcodes (60h or C7h) must be clocked into the device. Since the entire memory array is to be erased, no address
bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS
pin is deasserted, the device will erase the entire memory array. The erasing of the device is internally self-timed
and should take place in a time of tCHPE.
The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be
deasserted on an even byte boundary (multiples of eight bits); otherwise, no erase will be performed. In addition, if
any sector of the memory array is in the protected or locked down state, then the Chip Erase command will not be
executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Sta-
tus Register will be reset back to the logical “0” state if the CS pin is deasserted on uneven byte boundaries or if a
sector is in the protected or locked down state.
While the device is executing a successful erase cycle, the Status Register can be read and will indicate that the
device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the
tCHPE time to determine if the device has finished erasing. At some point before the erase cycle completes, the
WEL bit in the Status Register will be reset back to the logical “0” state.
The device also incorporates an intelligent erase algorithm that can detect when a byte location fails to erase prop-
erly. If an erase error occurs, it will be indicated by the EPE bit in the Status Register.
Figure 8-6. Chip Erase
SCK
CS
SI
SO
MSB
2310
CCCCCCCC
6754
OPCODE
HIGH-IMPEDANCE
17
8715E–SFLSH–11/2017
AT25DF081A
9. Protection Commands and Features
9.1 Write Enable
The Write Enable command is used to set the Write Enable Latch (WEL) bit in the Status Register to a logical “1”
state. The WEL bit must be set before a Byte/Page Program, erase, Protect Sector, Unprotect Sector, Sector Lock-
down, Freeze Sector Lockdown State, Program OTP Security Register, or Write Status Register command can be
executed. This makes the issuance of these commands a two step process, thereby reducing the chances of a
command being accidentally or erroneously executed. If the WEL bit in the Status Register is not set prior to the
issuance of one of these commands, then the command will not be executed.
To issue the Write Enable command, the CS pin must first be asserted and the opcode of 06h must be clocked into
the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be
ignored. When the CS pin is deasserted, the WEL bit in the Status Register will be set to a logical “1”. The com-
plete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted
on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and the state of the
WEL bit will not change.
Figure 9-1. Write Enable
SCK
CS
SI
SO
MSB
2310
00000110
6754
OPCODE
HIGH-IMPEDANCE
18
8715E–SFLSH–11/2017
AT25DF081A
9.2 Write Disable
The Write Disable command is used to reset the Write Enable Latch (WEL) bit in the Status Register to the logical
"0" state. With the WEL bit reset, all Byte/Page Program, erase, Protect Sector, Unprotect Sector, Sector Lock-
down, Freeze Sector Lockdown State, Program OTP Security Register, and Write Status Register commands will
not be executed. Other conditions can also cause the WEL bit to be reset; for more details, refer to the WEL bit
section of the Status Register description.
To issue the Write Disable command, the CS pin must first be asserted and the opcode of 04h must be clocked
into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will
be ignored. When the CS pin is deasserted, the WEL bit in the Status Register will be reset to a logical0. The
complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deas-
serted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and the
state of the WEL bit will not change.
Figure 9-2. Write Disable
SCK
CS
SI
SO
MSB
2310
00000100
6754
OPCODE
HIGH-IMPEDANCE
19
8715E–SFLSH–11/2017
AT25DF081A
9.3 Protect Sector
Every physical 64-Kbyte sector of the device has a corresponding single-bit Sector Protection Register that is used
to control the software protection of a sector. Upon device power-up, each Sector Protection Register will default to
the logical “1” state indicating that all sectors are protected and cannot be programmed or erased.
Issuing the Protect Sector command to a particular sector address will set the corresponding Sector Protection
Register to the logical “1” state. The following table outlines the two states of the Sector Protection Registers.
Before the Protect Sector command can be issued, the Write Enable command must have been previously issued
to set the WEL bit in the Status Register to a logical “1”. To issue the Protect Sector command, the CS pin must
first be asserted and the opcode of 36h must be clocked into the device followed by three address bytes designat-
ing any address within the sector to be protected. Any additional data clocked into the device will be ignored. When
the CS pin is deasserted, the Sector Protection Register corresponding to the physical sector addressed by A23-
A0 will be set to the logical “1” state, and the sector itself will then be protected from program and erase operations.
In addition, the WEL bit in the Status Register will be reset back to the logical “0” state.
The complete three address bytes must be clocked into the device before the CS pin is deasserted, and the CS pin
must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the opera-
tion. When the device aborts the Protect Sector operation, the state of the Sector Protection Register will be
unchanged, and the WEL bit in the Status Register will be reset to a logical “0”.
As a safeguard against accidental or erroneous protecting or unprotecting of sectors, the Sector Protection Regis-
ters can themselves be locked from updates by using the SPRL (Sector Protection Registers Locked) bit of the
Status Register (please refer to the Status Register description for more details). If the Sector Protection Registers
are locked, then any attempts to issue the Protect Sector command will be ignored, and the device will reset the
WEL bit in the Status Register back to a logical “0” and return to the idle state once the CS pin has been
deasserted.
Figure 9-3. Protect Sector
Table 9-1. Sector Protection Register Values
Value Sector Protection Status
0 Sector is unprotected and can be programmed and erased.
1 Sector is protected and cannot be programmed or erased. This is the default state.
SCK
CS
SI
SO
MSB MSB
2310
00110110
675410119812 3129 3027 2826
OPCODE
AAAA AAAA A A A A
ADDRESS BITS A23-A0
HIGH-IMPEDANCE
20
8715E–SFLSH–11/2017
AT25DF081A
9.4 Unprotect Sector
Issuing the Unprotect Sector command to a particular sector address will reset the corresponding Sector Protec-
tion Register to the logical “0” state (see Table 9-1 for Sector Protection Register values). Every physical sector of
the device has a corresponding single-bit Sector Protection Register that is used to control the software protection
of a sector.
Before the Unprotect Sector command can be issued, the Write Enable command must have been previously
issued to set the WEL bit in the Status Register to a logical 1”. To issue the Unprotect Sector command, the CS
pin must first be asserted and the opcode of 39h must be clocked into the device. After the opcode has been
clocked in, the three address bytes designating any address within the sector to be unprotected must be clocked
in. Any additional data clocked into the device after the address bytes will be ignored. When the CS pin is deas-
serted, the Sector Protection Register corresponding to the sector addressed by A23-A0 will be reset to the logical
“0” state, and the sector itself will be unprotected. In addition, the WEL bit in the Status Register will be reset back
to the logical “0” state.
The complete three address bytes must be clocked into the device before the CS pin is deasserted, and the CS pin
must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the opera-
tion, the state of the Sector Protection Register will be unchanged, and the WEL bit in the Status Register will be
reset to a logical “0”.
As a safeguard against accidental or erroneous locking or unlocking of sectors, the Sector Protection Registers
can themselves be locked from updates by using the SPRL (Sector Protection Registers Locked) bit of the Status
Register (please refer to the Status Register description for more details). If the Sector Protection Registers are
locked, then any attempts to issue the Unprotect Sector command will be ignored, and the device will reset the
WEL bit in the Status Register back to a logical “0” and return to the idle state once the CS pin has been
deasserted.
Figure 9-4. Unprotect Sector
SCK
CS
SI
SO
MSB MSB
2310
00111001
675410119812 3129 3027 2826
OPCODE
AAAA AAAA A A A A
ADDRESS BITS A23-A0
HIGH-IMPEDANCE
21
8715E–SFLSH–11/2017
AT25DF081A
9.5 Global Protect/Unprotect
The Global Protect and Global Unprotect features can work in conjunction with the Protect Sector and Unprotect
Sector functions. For example, a system can globally protect the entire memory array and then use the Unprotect
Sector command to individually unprotect certain sectors and individually reprotect them later by using the Protect
Sector command. Likewise, a system can globally unprotect the entire memory array and then individually protect
certain sectors as needed.
Performing a Global Protect or Global Unprotect is accomplished by writing a certain combination of data to the
Status Register using the Write Status Register Byte 1 command (see “Write Status Register Byte 1” on page 35
for command execution details). The Write Status Register command is also used to modify the SPRL (Sector Pro-
tection Registers Locked) bit to control hardware and software locking.
To perform a Global Protect, the appropriate WP pin and SPRL conditions must be met, and the system must write
a logical “1” to bits five, four, three, and two of the first byte of the Status Register. Conversely, to perform a Global
Unprotect, the same WP and SPRL conditions must be met but the system must write a logical “0” to bits five, four,
three, and two of the first byte of the Status Register. Table 9-2 details the conditions necessary for a Global Pro-
tect or Global Unprotect to be performed.
Table 9-2. Valid SPRL and Global Protect/Unprotect Conditions
WP
State
Current
SPRL
Value
New Write Status
Register Byte 1
Data
Protection Operation
New
SPRL
Value
Bit
7 6 5 4 3 2 1 0
00
0 x 0 0 0 0 x x
0 x 0 0 0 1 x x
0 x 1 1 1 0 x x
0 x 1 1 1 1 x x
1 x 0 0 0 0 x x
1 x 0 0 0 1 x x
1 x 1 1 1 0 x x
1 x 1 1 1 1 x x
Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection.
No change to current protection.
No change to current protection.
Global Protect – all Sector Protection Registers set to 1
Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection.
No change to current protection.
No change to current protection.
Global Protect – all Sector Protection Registers set to 1
0
0
0
0
0
1
1
1
1
1
0 1 x x x x x x x x
No change to the current protection level. All sectors currently protected will remain protected
and all sectors currently unprotected will remain unprotected.
The Sector Protection Registers are hard-locked and cannot be changed when the WP pin is
LOW and the current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur.
In addition, the SPRL bit cannot be changed (the WP pin must be HIGH in order to change
SPRL back to a 0).
10
0 x 0 0 0 0 x x
0 x 0 0 0 1 x x
0 x 1 1 1 0 x x
0 x 1 1 1 1 x x
1 x 0 0 0 0 x x
1 x 0 0 0 1 x x
1 x 1 1 1 0 x x
1 x 1 1 1 1 x x
Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection.
No change to current protection.
No change to current protection.
Global Protect – all Sector Protection Registers set to 1
Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection.
No change to current protection.
No change to current protection.
Global Protect – all Sector Protection Registers set to 1
0
0
0
0
0
1
1
1
1
1
22
8715E–SFLSH–11/2017
AT25DF081A
Essentially, if the SPRL bit of the Status Register is in the logical “0” state (Sector Protection Registers are not
locked), then writing a 00h to the first byte of the Status Register will perform a Global Unprotect without changing
the state of the SPRL bit. Similarly, writing a 7Fh to the first byte of the Status Register will perform a Global Protect
and keep the SPRL bit in the logical “0” state. The SPRL bit can, of course, be changed to a logical “1” by writing an
FFh if software-locking or hardware-locking is desired along with the Global Protect.
If the desire is to only change the SPRL bit without performing a Global Protect or Global Unprotect, then the sys-
tem can simply write a 0Fh to the first byte of the Status Register to change the SPRL bit from a logical “1” to a
logical “0” provided the WP pin is deasserted. Likewise, the system can write an F0h to change the SPRL bit from
a logical “0” to a logical “1” without affecting the current sector protection status (no changes will be made to the
Sector Protection Registers).
When writing to the first byte of the Status Register, bits five, four, three, and two will not actually be modified but
will be decoded by the device for the purposes of the Global Protect and Global Unprotect functions. Only bit
seven, the SPRL bit, will actually be modified. Therefore, when reading the first byte of the Status Register, bits
five, four, three, and two will not reflect the values written to them but will instead indicate the status of the WP pin
and the sector protection status. Please refer to “Read Status Register” on page 31 and Table 11-1 on page 31 for
details on the Status Register format and what values can be read for bits five, four, three, and two.
11
0 x 0 0 0 0 x x
0 x 0 0 0 1 x x
0 x 1 1 1 0 x x
0 x 1 1 1 1 x x
1 x 0 0 0 0 x x
1 x 0 0 0 1 x x
1 x 1 1 1 0 x x
1 x 1 1 1 1 x x
No change to the current protection level. All sectors currently protected will remain
protected, and all sectors currently unprotected will remain unprotected.
The Sector Protection Registers are soft-locked and cannot be changed when the
current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur.
However, the SPRL bit can be changed back to a 0 from a 1 since the WP pin is
HIGH. To perform a Global Protect/Unprotect, the Write Status Register command
must be issued again after the SPRL bit has been changed from a 1 to a 0.
0
0
0
0
0
1
1
1
1
1
Table 9-2. Valid SPRL and Global Protect/Unprotect Conditions (Continued)
WP
State
Current
SPRL
Value
New Write Status
Register Byte 1
Data
Protection Operation
New
SPRL
Value
Bit
7 6 5 4 3 2 1 0
23
8715E–SFLSH–11/2017
AT25DF081A
9.6 Read Sector Protection Registers
The Sector Protection Registers can be read to determine the current software protection status of each sector.
Reading the Sector Protection Registers, however, will not determine the status of the WP pin.
To read the Sector Protection Register for a particular sector, the CS pin must first be asserted and the opcode of
3Ch must be clocked in. Once the opcode has been clocked in, three address bytes designating any address
within the sector must be clocked in. After the last address byte has been clocked in, the device will begin output-
ting data on the SO pin during every subsequent clock cycle. The data being output will be a repeating byte of
either FFh or 00h to denote the value of the appropriate Sector Protection Register.
At clock frequencies above fCLK, the first byte of data output will not be valid. Therefore, if operating at clock fre-
quencies above fCLK, at least two bytes of data must be clocked out from the device in order to determine the
correct status of the appropriate Sector Protection Register.
Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS
pin can be deasserted at any time and does not require that a full byte of data be read.
In addition to reading the individual Sector Protection Registers, the Software Protection Status (SWP) bits in the
Status Register can be read to determine if all, some, or none of the sectors are software protected (refer to “Read
Status Register” on page 31 for more details).
Figure 9-5. Read Sector Protection Register
Table 9-3. Read Sector Protection Register – Output Data
Output Data Sector Protection Register Value
00h Sector Protection Register value is 0 (sector is unprotected)
FFh Sector Protection Register value is 1 (sector is protected)
SCK
CS
SI
SO
MSB MSB
2310
00111100
675410119812 373833 36353431 3229 30 39 40
OPCODE
AAAA AAAA A
MSB MSB
DDDDDDDDDD
ADDRESS BITS A23-A0
DATA BYTE
HIGH-IMPEDANCE
24
8715E–SFLSH–11/2017
AT25DF081A
9.7 Protected States and the Write Protect (WP) Pin
The WP pin is not linked to the memory array itself and has no direct effect on the protection status or lockdown
status of the memory array. Instead, the WP pin, in conjunction with the SPRL (Sector Protection Registers
Locked) bit in the Status Register, is used to control the hardware locking mechanism of the device. For hardware
locking to be active, two conditions must be met-the WP pin must be asserted and the SPRL bit must be in the log-
ical “1” state.
When hardware locking is active, the Sector Protection Registers are locked and the SPRL bit itself is also locked.
Therefore, sectors that are protected will be locked in the protected state, and sectors that are unprotected will be
locked in the unprotected state. These states cannot be changed as long as hardware locking is active, so the Pro-
tect Sector, Unprotect Sector, and Write Status Register commands will be ignored. In order to modify the
protection status of a sector, the WP pin must first be deasserted, and the SPRL bit in the Status Register must be
reset back to the logical “0” state using the Write Status Register command. When resetting the SPRL bit back to a
logical “0”, it is not possible to perform a Global Protect or Global Unprotect at the same time since the Sector Pro-
tection Registers remain soft-locked until after the Write Status Register command has been executed.
If the WP pin is permanently connected to GND, then once the SPRL bit is set to a logical “1”, the only way to reset
the bit back to the logical “0” state is to power-cycle the device. This allows a system to power-up with all sectors
software protected but not hardware locked. Therefore, sectors can be unprotected and protected as needed and
then hardware locked at a later time by simply setting the SPRL bit in the Status Register.
When the WP pin is deasserted, or if the WP pin is permanently connected to VCC, the SPRL bit in the Status Reg-
ister can still be set to a logical “1” to lock the Sector Protection Registers. This provides a software locking ability
to prevent erroneous Protect Sector or Unprotect Sector commands from being processed. When changing the
SPRL bit to a logical “1” from a logical “0”, it is also possible to perform a Global Protect or Global Unprotect at the
same time by writing the appropriate values into bits five, four, three, and two of the first byte of the Status
Register.
Tables 9-4 and 9-5 detail the various protection and locking states of the device.
Note: 1. “n” represents a sector number
Table 9-4. Sector Protection Register States
WP
Sector Protection Register
n(1)
Sector
n(1)
X
(Don't Care)
0 Unprotected
1Protected
Table 9-5. Hardware and Software Locking
WP SPRL Locking SPRL Change Allowed Sector Protection Registers
0 0 Can be modified from 0 to 1
Unlocked and modifiable using the Protect and Unprotect
Sector commands. Global Protect and Unprotect can also be
performed.
01
Hardware
Locked Locked
Locked in current state. Protect and Unprotect Sector
commands will be ignored. Global Protect and Unprotect
cannot be performed.
1 0 Can be modified from 0 to 1
Unlocked and modifiable using the Protect and Unprotect
Sector commands. Global Protect and Unprotect can also be
performed.
11
Software
Locked Can be modified from 1 to 0
Locked in current state. Protect and Unprotect Sector
commands will be ignored. Global Protect and Unprotect
cannot be performed.
25
8715E–SFLSH–11/2017
AT25DF081A
10. Security Commands
10.1 Sector Lockdown
Certain applications require that portions of the Flash memory array be permanently protected against malicious
attempts at altering program code, data modules, security information, or encryption/decryption algorithms, keys,
and routines. To address these applications, the device incorporates a sector lockdown mechanism that allows any
combination of individual 64-Kbyte sectors to be permanently locked so that they become read only. Once a sector
is locked down, it can never be erased or programmed again, and it can never be unlocked from the locked down
state.
Each 64-Kbyte physical sector has a corresponding single-bit Sector Lockdown Register that is used to control the
lockdown status of that sector. These registers are nonvolatile and will retain their state even after a device power-
cycle or reset operation. The following table outlines the two states of the Sector Lockdown Registers.
Issuing the Sector Lockdown command to a particular sector address will set the corresponding Sector Lockdown
Register to the logical “1” state. Each Sector Lockdown Register can only be set once; therefore, once set to the
logical “1” state, a Sector Lockdown Register cannot be reset back to the logical “0” state.
Before the Sector Lockdown command can be issued, the Write Enable command must have been previously
issued to set the WEL bit in the Status Register to a logical “1”. In addition, the Sector Lockdown Enabled (SLE) bit
in the Status Register must have also been previously set to the logical “1” state by using the Write Status Register
Byte 2 command (see “Write Status Register Byte 2” on page 36). To issue the Sector Lockdown command, the
CS pin must first be asserted and the opcode of 33h must be clocked into the device followed by three address
bytes designating any address within the 64-Kbyte sector to be locked down. After the three address bytes have
been clocked in, a confirmation byte of D0h must also be clocked in immediately following the three address bytes.
Any additional data clocked into the device after the first byte of data will be ignored. When the CS pin is deas-
serted, the Sector Lockdown Register corresponding to the sector addressed by A23-A0 will be set to the logical
“1” state, and the sector itself will then be permanently locked down from program and erase operations within a
time of tLOCK. In addition, the WEL bit in the Status Register will be reset back to the logical “0” state.
The complete three address bytes and the correct confirmation byte value of D0h must be clocked into the device
before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight
bits); otherwise, the device will abort the operation. When the device aborts the Sector Lockdown operation, the
state of the corresponding Sector Lockdown Register as well as the SLE bit in the Status Register will be
unchanged; however, the WEL bit in the Status Register will be reset to a logical “0”.
As a safeguard against accidental or erroneous locking down of sectors, the Sector Lockdown command can be
enabled and disabled as needed by using the SLE bit in the Status Register. In addition, the current sector lock-
down state can be frozen so that no further modifications to the Sector Lockdown Registers can be made (see
“Freeze Sector Lockdown State” below). If the Sector Lockdown command is disabled or if the sector lockdown
state is frozen, then any attempts to issue the Sector Lockdown command will be ignored, and the device will reset
the WEL bit in the Status Register back to a logical “0” and return to the idle state once the CS pin has been
deasserted.
Table 10-1. Sector Lockdown Register Values
Value Sector Lockdown Status
0 Sector is not locked down and can be programmed and erased. This is the default state.
1 Sector is permanently locked down and can never be programmed or erased again.
26
8715E–SFLSH–11/2017
AT25DF081A
Figure 10-1. Sector Lockdown
10.2 Freeze Sector Lockdown State
The current sector lockdown state can be permanently frozen so that no further modifications to the Sector Lock-
down Registers can be made; therefore, the Sector Lockdown command will be permanently disabled, and no
additional sectors can be locked down aside from those already locked down. Any attempts to issue the Sector
Lockdown command after the sector lockdown state has been frozen will be ignored.
Before the Freeze Sector Lockdown State command can be issued, the Write Enable command must have been
previously issued to set the WEL bit in the Status Register to a logical “1”. In addition, the Sector Lockdown
Enabled (SLE) bit in the Status Register must have also been previously set to the logical “1” state. To issue the
Freeze Sector Lockdown State command, the CS pin must first be asserted and the opcode of 34h must be
clocked into the device followed by three command specific address bytes of 55AA40h. After the three address
bytes have been clocked in, a confirmation byte of D0h must be clocked in immediately following the three address
bytes. Any additional data clocked into the device will be ignored. When the CS pin is deasserted, the current sec-
tor lockdown state will be permanently frozen within a time of tLOCK. In addition, the WEL bit in the Status Register
will be reset back to the logical “0” state, and the SLE bit will be permanently reset to a logical “0” to indicate that
the Sector Lockdown command is permanently disabled.
The complete and correct three address bytes and the confirmation byte must be clocked into the device before the
CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); other-
wise, the device will abort the operation. When the device aborts the Freeze Sector Lockdown State operation, the
WEL bit in the Status Register will be reset to a logical “0”; however, the state of the SLE bit will be unchanged.
Figure 10-2. Freeze Sector Lockdown State
SCK
CS
SI
SO
MSB MSB
2310
00110011
6754983937 3833 36353431 3229 30
OPCODE
HIGH-IMPEDANCE
AA AAAA
MSB
11010000
ADDRESS BITS A23-A0 CONFIRMATION BYTE IN
SCK
CS
SI
SO
MSB MSB
2310
00110100
6754983937 3833 36353431 3229 30
OPCODE
HIGH-IMPEDANCE
01 0000
MSB
11010000
ADDRESS BITS A23-A0 CONFIRMATION BYTE IN
27
8715E–SFLSH–11/2017
AT25DF081A
10.3 Read Sector Lockdown Registers
The Sector Lockdown Registers can be read to determine the current lockdown status of each physical 64-Kbyte
sector. To read the Sector Lockdown Register for a particular 64-Kbyte sector, the CS pin must first be asserted
and the opcode of 35h must be clocked in. Once the opcode has been clocked in, three address bytes designating
any address within the 64-Kbyte sector must be clocked in. After the address bytes have been clocked in, data will
be output on the SO pin during every subsequent clock cycle. The data being output will be a repeating byte of
either FFh or 00h to denote the value of the appropriate Sector Lockdown Register.
At clock frequencies above fCLK, the first byte of data output will not be valid. Therefore, if operating at clock fre-
quencies above fCLK, at least two bytes of data must be clocked out from the device in order to determine the
correct status of the appropriate Sector Lockdown Register.
Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS
pin can be deasserted at any time and does not require that a full byte of data be read.
Figure 10-3. Read Sector Lockdown Register
Table 10-2. Read Sector Lockdown Register – Output Data
Output Data Sector Lockdown Register Value
00h Sector Lockdown Register value is 0 (sector is not locked down)
FFh Sector Lockdown Register value is 1 (sector is permanently locked down)
SCK
CS
SI
SO
MSB MSB
2310
00110101
675410119812 394243414037 3833 36353431 3229 30 44 47 484645
OPCODE
AAAA AAAA A
MSB
XXXXXXXX
MSB MSB
DDDDDDDDDD
ADDRESS BITS A23-A0 DON'T CARE
DATA BYTE
HIGH-IMPEDANCE
28
8715E–SFLSH–11/2017
AT25DF081A
10.4 Program OTP Security Register
The device contains a specialized OTP (One-Time Programmable) Security Register that can be used for pur-
poses such as unique device serialization, system-level Electronic Serial Number (ESN) storage, locked key
storage, etc. The OTP Security Register is independent of the main Flash memory array and is comprised of a total
of 128-bytes of memory divided into two portions. The first 64-bytes (byte locations 0 through 63) of the OTP Secu-
rity Register are allocated as a one-time user-programmable space. Once these 64-bytes have been programmed,
they cannot be erased or reprogrammed. The remaining 64-bytes of the OTP Security Register (byte locations 64
through 127) are factory programmed by Adesto and will contain a unique value for each device. The factory pro-
grammed data is fixed and cannot be changed.
The user-programmable portion of the OTP Security Register does not need to be erased before it is programmed.
In addition, the Program OTP Security Register command operates on the entire 64-byte user-programmable por-
tion of the OTP Security Register at one time. Once the user-programmable space has been programmed with any
number of bytes, the user-programmable space cannot be programmed again; therefore, it is not possible to only
program the first two bytes of the register and then program the remaining 62-bytes at a later time.
Before the Program OTP Security Register command can be issued, the Write Enable command must have been
previously issued to set the WEL bit in the Status Register to a logical “1”. To program the OTP Security Register,
the CS pin must first be asserted and an opcode of 9Bh must be clocked into the device followed by the three
address bytes denoting the first byte location of the OTP Security Register to begin programming at. Since the size
of the user-programmable portion of the OTP Security Register is 64-bytes, the upper order address bits do not
need to be decoded by the device. Therefore, address bits A23-A6 will be ignored by the device and their values
can be either a logical “1” or 0”. After the address bytes have been clocked in, data can then be clocked into the
device and will be stored in the internal buffer.
If the starting memory address denoted by A23-A0 does not start at the beginning of the OTP Security Register
memory space (A5-A0 are not all 0), then special circumstances regarding which OTP Security Register locations
to be programmed will apply. In this situation, any data that is sent to the device that goes beyond the end of the
64-byte user-programmable space will wrap around back to the beginning of the OTP Security Register. For exam-
ple, if the starting address denoted by A23-A0 is 00003Eh, and three bytes of data are sent to the device, then the
first two bytes of data will be programmed at OTP Security Register addresses 00003Eh and 00003Fh while the
last byte of data will be programmed at address 000000h. The remaining bytes in the OTP Security Register
(addresses 000001h through 00003Dh) will not be programmed and will remain in the erased state (FFh). In addi-
tion, if more than 64-bytes of data are sent to the device, then only the last 64-bytes sent will be latched into the
internal buffer.
When the CS pin is deasserted, the device will take the data stored in the internal buffer and program it into the
appropriate OTP Security Register locations based on the starting address specified by A23-A0 and the number of
data bytes sent to the device. If less than 64-bytes of data were sent to the device, then the remaining bytes within
the OTP Security Register will not be programmed and will remain in the erased state (FFh). The programming of
the data bytes is internally self-timed and should take place in a time of tOTPP. It is not possible to suspend the pro-
gramming of the OTP Security Register.
Table 10-3. OTP Security Register
Security Register
Byte Number
01. . . 62 63 64 65 . . . 126 127
One-Time User Programmable Factory Programmed by Adesto
29
8715E–SFLSH–11/2017
AT25DF081A
The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin
is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the
device will abort the operation and the user-programmable portion of the OTP Security Register will not be pro-
grammed. The WEL bit in the Status Register will be reset back to the logical “0” state if the OTP Security Register
program cycle aborts due to an incomplete address being sent, an incomplete byte of data being sent, the CS pin
being deasserted on uneven byte boundaries, or because the user-programmable portion of the OTP Security
Register was previously programmed.
While the device is programming the OTP Security Register, the Status Register can be read and will indicate that
the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting
the tOTPP time to determine if the data bytes have finished programming. At some point before the OTP Security
Register programming completes, the WEL bit in the Status Register will be reset back to the logical “0” state.
If the device is powered-down during the OTP Security Register program cycle, then the contents of the 64-byte
user programmable portion of the OTP Security Register cannot be guaranteed and cannot be programmed again.
The Program OTP Security Register command utilizes the internal 256-buffer for processing. Therefore, the con-
tents of the buffer will be altered from its previous state when this command is issued.
Figure 10-4. Program OTP Security Register
SCK
CS
SI
SO
MSB MSB
2310
10011011
6754983937 3833 36353431 3229 30
OPCODE
HIGH-IMPEDANCE
AA AAAA
MSB
DDDDDDDD
ADDRESS BITS A23-A0 DATA IN BYTE 1
MSB
DDDDDDDD
DATA IN BYTE n
30
8715E–SFLSH–11/2017
AT25DF081A
10.5 Read OTP Security Register
The OTP Security Register can be sequentially read in a similar fashion to the Read Array operation up to the max-
imum clock frequency specified by fMAX. To read the OTP Security Register, the CS pin must first be asserted and
the opcode of 77h must be clocked into the device. After the opcode has been clocked in, the three address bytes
must be clocked in to specify the starting address location of the first byte to read within the OTP Security Register.
Following the three address bytes, two dummy bytes must be clocked into the device before data can be output.
After the three address bytes and the dummy bytes have been clocked in, additional clock cycles will result in OTP
Security Register data being output on the SO pin. When the last byte (00007Fh) of the OTP Security Register has
been read, the device will continue reading back at the beginning of the register (000000h). No delays will be
incurred when wrapping around from the end of the register to the beginning of the register.
Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS
pin can be deasserted at any time and does not require that a full byte of data be read.
Figure 10-5. Read OTP Security Register
SCK
CS
SI
SO
MSB MSB
2310
01110111
675410119812 3336353431 3229 30
OPCODE
AAAA AAAAAXXX
MSB MSB
DDDDDDDDDD
ADDRESS BITS A23-A0
MSB
XXXXXX
DON'T CARE
DATA BYTE 1
HIGH-IMPEDANCE
31
8715E–SFLSH–11/2017
AT25DF081A
11. Status Register Commands
11.1 Read Status Register
The two-byte Status Register can be read to determine the device’s ready/busy status, as well as the status of
many other functions such as Hardware Locking and Software Protection. The Status Register can be read at any
time, including during an internally self-timed program or erase operation.
To read the Status Register, the CS pin must first be asserted and the opcode of 05h must be clocked into the
device. After the opcode has been clocked in, the device will begin outputting Status Register data on the SO pin
during every subsequent clock cycle. After the second byte of the Status Register has been clocked out, the
sequence will repeat itself starting again with the first byte of the Status Register as long as the CS pin remains
asserted and the clock pin is being pulsed. The data in the Status Register is constantly being updated, so each
repeating sequence will output new data. The RDY/BSY status is available for both bytes of the Status Register
and is updated for each byte.
At clock frequencies above fCLK, the first two bytes of data output from the Status Register will not be valid. There-
fore, if operating at clock frequencies above fCLK, at least four bytes of data must be clocked out from the device in
order to read the correct values of both bytes of the Status Register.
Deasserting the CS pin will terminate the Read Status Register operation and put the SO pin into a high-imped-
ance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read.
Notes: 1. Only bit 7 of Status Register Byte 1 will be modified when using the Write Status Register Byte 1 command.
2. R/W = Readable and writeable
R = Readable only
Table 11-1. Status Register Format – Byte 1
Bit(1) Name Type(2) Description
7 SPRL Sector Protection Registers Locked R/W
0 Sector Protection Registers are unlocked (default)
1 Sector Protection Registers are locked
6 RES Reserved for future use R 0 Reserved for future use
5 EPE Erase/Program Error R
0 Erase or program operation was successful
1 Erase or program error detected
4 WPP Write Protect (WP) Pin Status R
0WP is asserted
1WP
is deasserted
3:2 SWP Software Protection Status R
00 All sectors are software unprotected (all Sector
Protection Registers are 0)
01
Some sectors are software protected. Read
individual Sector Protection Registers to determine
which sectors are protected
10 Reserved for future use
11 All sectors are software protected (all Sector
Protection Registers are 1 – default)
1 WEL Write Enable Latch Status R
0 Device is not write enabled (default)
1 Device is write enabled
0 RDY/BSY Ready/Busy Status R
0 Device is ready
1 Device is busy with an internal operation
32
8715E–SFLSH–11/2017
AT25DF081A
Notes: 1. Only bits 4 and 3 of Status Register Byte 2 will be modified when using the Write Status Register Byte 2 command.
2. R/W = Readable and writeable
R = Readable only
11.1.1 SPRL Bit
The SPRL bit is used to control whether the Sector Protection Registers can be modified or not. When the SPRL
bit is in the logical “1” state, all Sector Protection Registers are locked and cannot be modified with the Protect Sec-
tor and Unprotect Sector commands (the device will ignore these commands). In addition, the Global Protect and
Global Unprotect features cannot be performed. Any sectors that are presently protected will remain protected, and
any sectors that are presently unprotected will remain unprotected.
When the SPRL bit is in the logical “0” state, all Sector Protection Registers are unlocked and can be modified (the
Protect Sector and Unprotect Sector commands, as well as the Global Protect and Global Unprotect features, will
be processed as normal). The SPRL bit defaults to the logical 0” state after device power-up. The Reset command
has no effect on the SPRL bit.
The SPRL bit can be modified freely whenever the WP pin is deasserted. However, if the WP pin is asserted, then
the SPRL bit may only be changed from a logical “0(Sector Protection Registers are unlocked) to a logical “1
(Sector Protection Registers are locked). In order to reset the SPRL bit back to a logical “0” using the Write Status
Register Byte 1 command, the WP pin will have to first be deasserted.
The SPRL bit is the only bit of Status Register Byte 1 that can be user modified via the Write Status Register Byte
1 command.
11.1.2 EPE Bit
The EPE bit indicates whether the last erase or program operation completed successfully or not. If at least one
byte during the erase or program operation did not erase or program properly, then the EPE bit will be set to the
logical “1” state. The EPE bit will not be set if an erase or program operation aborts for any reason such as an
attempt to erase or program a protected region or a locked down sector or if the WEL bit is not set prior to an erase
or program operation. The EPE bit will be updated after every erase and program operation.
Table 11-2. Status Register Format – Byte 2
Bit(1) Name Type(2) Description
7 RES Reserved for future use R 0 Reserved for future use
6 RES Reserved for future use R 0 Reserved for future use
5 RES Reserved for future use R 0 Reserved for future use
4 RSTE Reset Enabled R/W
0 Reset command is disabled (default)
1 Reset command is enabled
3 SLE Sector Lockdown Enabled R/W
0Sector Lockdown and Freeze Sector Lockdown State
commands are disabled (default)
1Sector Lockdown and Freeze Sector Lockdown State
commands are enabled
2 RES Reserved for future use R 0 Reserved for future use
1 RES Reserved for future use R 0 Reserved for future use
0 RDY/BSY Ready/Busy Status R
0 Device is ready
1 Device is busy with an internal operation
33
8715E–SFLSH–11/2017
AT25DF081A
11.1.3 WPP Bit
The WPP bit can be read to determine if the WP pin has been asserted or not.
11.1.4 SWP Bits
The SWP bits provide feedback on the software protection status for the device. There are three possible combina-
tions of the SWP bits that indicate whether none, some, or all of the sectors have been protected using the Protect
Sector command or the Global Protect feature. If the SWP bits indicate that some of the sectors have been pro-
tected, then the individual Sector Protection Registers can be read with the Read Sector Protection Registers
command to determine which sectors are in fact protected.
11.1.5 WEL Bit
The WEL bit indicates the current status of the internal Write Enable Latch. When the WEL bit is in the logical “0”
state, the device will not accept any Byte/Page Program, erase, Protect Sector, Unprotect Sector, Sector Lock-
down, Freeze Sector Lockdown State, Program OTP Security Register, or Write Status Register commands. The
WEL bit defaults to the logical “0” state after a device power-up or reset operation. In addition, the WEL bit will be
reset to the logical “0” state automatically under the following conditions:
Write Disable operation completes successfully
Write Status Register operation completes successfully or aborts
Protect Sector operation completes successfully or aborts
Unprotect Sector operation completes successfully or aborts
Sector Lockdown operation completes successfully or aborts
Freeze Sector Lockdown State operation completes successfully or aborts
Program OTP Security Register operation completes successfully or aborts
Byte/Page Program operation completes successfully or aborts
Block Erase operation completes successfully or aborts
Chip Erase operation completes successfully or aborts
Hold condition aborts
If the WEL bit is in the logical “1” state, it will not be reset to a logical “0” if an operation aborts due to an incomplete
or unrecognized opcode being clocked into the device before the CS pin is deasserted. In order for the WEL bit to
be reset when an operation aborts prematurely, the entire opcode for a Byte/Page Program, erase, Protect Sector,
Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, or Write Sta-
tus Register command must have been clocked into the device.
11.1.6 RSTE Bit
The RSTE bit is used to enable or disable the Reset command. When the RSTE bit is in the logical “0” state (the
default state after power-up), the Reset command is disabled and any attempts to reset the device using the Reset
command will be ignored. When the RSTE bit is in the logical “1” state, the Reset command is enabled.
The RSTE bit will retain its state as long as power is applied to the device. Once set to the logical “1” state, the
RSTE bit will remain in that state until it is modified using the Write Status Register Byte 2 command or until the
device has been power cycled. The Reset command itself will not change the state of the RSTE bit.
34
8715E–SFLSH–11/2017
AT25DF081A
11.1.7 SLE Bit
The SLE bit is used to enable and disable the Sector Lockdown and Freeze Sector Lockdown State commands.
When the SLE bit is in the logical “0” state (the default state after power-up), the Sector Lockdown and Freeze Sec-
tor Lockdown commands are disabled. If the Sector Lockdown and Freeze Sector Lockdown commands are
disabled, then any attempts to issue the commands will be ignored. This provides a safeguard for these commands
against accidental or erroneous execution. When the SLE bit is in the logical “1” state, the Sector Lockdown and
Freeze Sector Lockdown State commands are enabled.
Unlike the WEL bit, the SLE bit does not automatically reset after certain device operations. Therefore, once set,
the SLE bit will remain in the logical “1” state until it is modified using the Write Status Register Byte 2 command or
until the device has been power cycled. The Reset command has no effect on the SLE bit.
If the Freeze Sector Lockdown State command has been issued, then the SLE bit will be permanently reset in the
logical “0” state to indicate that the Sector Lockdown command has been disabled.
11.1.8 RDY/BSY Bit
The RDY/BSY bit is used to determine whether or not an internal operation, such as a program or erase, is in prog-
ress. To poll the RDY/BSY bit to detect the completion of a program or erase cycle, new Status Register data must
be continually clocked out of the device until the state of the RDY/BSY bit changes from a logical “1” to a logical “0”.
Figure 11-1. Read Status Register
SCK
CS
SI
SO
MSB
2310
00000101
675410119812 212217 20191815 1613 14 23 24 28 29272625 30
OPCODE
MSB MSB
DDDDDD DDDD
MSB
DDDDDDDD DD DD D D
STATUS REGISTER
BYTE 1
STATUS REGISTER
BYTE 1
STATUS REGISTER
BYTE 2
HIGH-IMPEDANCE
35
8715E–SFLSH–11/2017
AT25DF081A
11.2 Write Status Register Byte 1
The Write Status Register Byte 1 command is used to modify the SPRL bit of the Status Register and/or to perform
a Global Protect or Global Unprotect operation. Before the Write Status Register Byte 1 command can be issued,
the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical
“1”.
To issue the Write Status Register Byte 1 command, the CS pin must first be asserted and the opcode of 01h must
be clocked into the device followed by one byte of data. The one byte of data consists of the SPRL bit value, a
don’t care bit, four data bits to denote whether a Global Protect or Unprotect should be performed, and two addi-
tional don’t care bits (see Table 11-3). Any additional data bytes that are sent to the device will be ignored. When
the CS pin is deasserted, the SPRL bit in the Status Register will be modified, and the WEL bit in the Status Regis-
ter will be reset back to a logical “0”. The values of bits five, four, three, and two and the state of the SPRL bit
before the Write Status Register Byte 1 command was executed (the prior state of the SPRL bit) will determine
whether or not a Global Protect or Global Unprotect will be performed. Please refer to “Global Protect/Unprotect”
on page 21 for more details.
The complete one byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin
must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation,
the state of the SPRL bit will not change, no potential Global Protect or Unprotect will be performed, and the WEL
bit in the Status Register will be reset back to the logical “0” state.
If the WP pin is asserted, then the SPRL bit can only be set to a logical “1”. If an attempt is made to reset the SPRL
bit to a logical “0” while the WP pin is asserted, then the Write Status Register Byte 1 command will be ignored, and
the WEL bit in the Status Register will be reset back to the logical “0” state. In order to reset the SPRL bit to a logi-
cal “0”, the WP pin must be deasserted.
Figure 11-2. Write Status Register Byte 1
Table 11-3. Write Status Register Byte 1 Format
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SPRL X Global Protect/Unprotect X X
SCK
CS
SI
SO
MSB
2310
0000000
6754
OPCODE
10 119814151312
1
MSB
DXDDDDX X
STATUS REGISTER IN
BYTE 1
HIGH-IMPEDANCE
36
8715E–SFLSH–11/2017
AT25DF081A
11.3 Write Status Register Byte 2
The Write Status Register Byte 2 command is used to modify the RSTE and SLE bits of the Status Register. Using
the Write Status Register Byte 2 command is the only way to modify the RSTE and SLE bits in the Status Register
during normal device operation, and the SLE bit can only be modified if the sector lockdown state has not been fro-
zen. Before the Write Status Register Byte 2 command can be issued, the Write Enable command must have been
previously issued to set the WEL bit in the Status Register to a logical “1”.
To issue the Write Status Register Byte 2 command, the CS pin must first be asserted and the opcode of 31h must
be clocked into the device followed by one byte of data. The one byte of data consists of three don’t care bits, the
RSTE bit value, the SLE bit value, and three additional don’t care bits (see Table 11-4). Any additional data bytes
that are sent to the device will be ignored. When the CS pin is deasserted, the RSTE and SLE bits in the Status
Register will be modified, and the WEL bit in the Status Register will be reset back to a logical “0”. The SLE bit will
only be modified if the Freeze Sector Lockdown State command has not been previously issued.
The complete one byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin
must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation,
the state of the RSTE and SLE bits will not change, and the WEL bit in the Status Register will be reset back to the
logical “0” state.
Figure 11-3. Write Status Register Byte 2
Table 11-4. Write Status Register Byte 2 Format
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
XXXRSTESLEXXX
SCK
CS
SI
SO
MSB
2310
0011000
6754
OPCODE
10 119814151312
1
MSB
XXXDDXX X
STATUS REGISTER IN
BYTE 2
HIGH-IMPEDANCE
37
8715E–SFLSH–11/2017
AT25DF081A
12. Other Commands and Functions
12.1 Reset
In some applications, it may be necessary to prematurely terminate a program or erase cycle early rather than wait
the hundreds of microseconds or milliseconds necessary for the program or erase operation to complete normally.
The Reset command allows a program or erase operation in progress to be ended abruptly and returns the device
to an idle state. Since the need to reset the device is immediate, the Write Enable command does not need to be
issued prior to the Reset command being issued. Therefore, the Reset command operates independently of the
state of the WEL bit in the Status Register.
The Reset command can only be executed if the command has been enabled by setting the Reset Enabled
(RSTE) bit in the Status Register to a logical “1”. If the Reset command has not been enabled (the RSTE bit is in
the logical “0” state), then any attempts at executing the Reset command will be ignored.
To perform a Reset, the CS pin must first be asserted and the opcode of F0h must be clocked into the device. No
address bytes need to be clocked in, but a confirmation byte of D0h must be clocked into the device immediately
after the opcode. Any additional data clocked into the device after the confirmation byte will be ignored. When the
CS pin is deasserted, the program or erase operation currently in progress will be terminated within a time of tRST.
Since the program or erase operation may not complete before the device is reset, the contents of the page being
programmed or the block being erased cannot be guaranteed to be valid.
The Reset command has no effect on the states of the Sector Protection Registers, the Sector Lockdown Regis-
ters, or the SPRL, RSTE, and SLE bits in the Status Register. The WEL, PS, and ES bits, however, will be reset
back to their default states.
The complete opcode and confirmation byte must be clocked into the device before the CS pin is deasserted, and
the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no Reset operation
will be performed.
Figure 12-1. Reset
SCK
CS
SI
SO
MSB
2310
1111000
6754
OPCODE CONFIRMATION BYTE IN
10 119814151312
0
MSB
1101000 0
HIGH-IMPEDANCE
38
8715E–SFLSH–11/2017
AT25DF081A
12.2 Read Manufacturer and Device ID
Identification information can be read from the device to enable systems to electronically query and identify the
device while it is in system. The identification method and the command opcode comply with the JEDEC standard
for “Manufacturer and Device ID Read Methodology for SPI Compatible Serial Interface Memory Devices”. The
type of information that can be read from the device includes the JEDEC defined Manufacturer ID, the vendor spe-
cific Device ID, and the vendor specific Extended Device Information.
The Read Manufacturer and Device ID command is limited to a maximum clock frequency of fCLK. Since not all
Flash devices are capable of operating at very high clock frequencies, applications should be designed to read the
identification information from the devices at a reasonably low clock frequency to ensure that all devices to be used
in the application can be identified properly. Once the identification process is complete, the application can then
increase the clock frequency to accommodate specific Flash devices that are capable of operating at the higher
clock frequencies.
To read the identification information, the CS pin must first be asserted and the opcode of 9Fh must be clocked into
the device. After the opcode has been clocked in, the device will begin outputting the identification data on the SO
pin during the subsequent clock cycles. The first byte that will be output will be the Manufacturer ID followed by two
bytes of Device ID information. The fourth byte output will be the Extended Device Information String Length, which
will be 00h indicating that no Extended Device Information follows. After the Extended Device Information String
Length byte is output, the SO pin will go into a high-impedance state; therefore, additional clock cycles will have no
affect on the SO pin and no data will be output. As indicated in the JEDEC standard, reading the Extended Device
Information String Length and any subsequent data is optional.
Deasserting the CS pin will terminate the Manufacturer and Device ID read operation and put the SO pin into a
high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be
read.
Table 12-1. Manufacturer and Device ID Information
Byte No. Data Type Value
1 Manufacturer ID 1Fh
2 Device ID (Part 1) 45h
3 Device ID (Part 2) 01h
4 [Optional to read] Extended Device Information (EDI) String Length 01h
5 [Optional to read] EDI Byte 1 00h
Table 12-2. Manufacturer and Device ID Details
Data Type Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Hex
Value Details
Manufacturer ID
JEDEC Assigned Code
1Fh JEDEC Code: 0001 1111 (1Fh for Adesto)
00011111
Device ID (Part 1)
Family Code Density Code
45h Family Code: 010 (AT25DF/26DFxxx series)
Density Code: 00101 (8-Mbit)
01000101
Device ID (Part 2)
Sub Code Product Version Code
01h Sub Code: 000 (Standard series)
Product Version: 00001 (Second major version)
00000001
39
8715E–SFLSH–11/2017
AT25DF081A
Figure 12-2. Read Manufacturer and Device ID
12.3 Deep Power-Down
During normal operation, the device will be placed in the standby mode to consume less power as long as the CS
pin remains deasserted and no internal operation is in progress. The Deep Power-Down command offers the ability
to place the device into an even lower power consumption state called the Deep Power-Down mode.
When the device is in the Deep Power-Down mode, all commands including the Read Status Register command
will be ignored with the exception of the Resume from Deep Power-Down command. Since all commands will be
ignored, the mode can be used as an extra protection mechanism against program and erase operations.
Entering the Deep Power-Down mode is accomplished by simply asserting the CS pin, clocking in the opcode of
B9h, and then deasserting the CS pin. Any additional data clocked into the device after the opcode will be ignored.
When the CS pin is deasserted, the device will enter the Deep Power-Down mode within the maximum time of
tEDPD.
The complete opcode must be clocked in before the CS pin is deasserted, and the CS pin must be deasserted on
an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and return to the
standby mode once the CS pin is deasserted. In addition, the device will default to the standby mode after a power-
cycle.
The Deep Power-Down command will be ignored if an internally self-timed operation such as a program or erase
cycle is in progress. The Deep Power-Down command must be reissued after the internally self-timed operation
has been completed in order for the device to enter the Deep Power-Down mode.
6&.
&6
6,
62
)K
   
)K K K K K
+,*+,03('$1&(
     
OPCODE
MANUFACTURED ID DEVICE ID
BYTE 1
DEVICE ID
BYTE 2
EDI
STRING LENGTH
EDI
DATA BYTE 1
Note: Each transition shown for SI and SO represents one byte (8 bits)
40
8715E–SFLSH–11/2017
AT25DF081A
Figure 12-3. Deep Power-Down
12.4 Resume from Deep Power-Down
In order to exit the Deep Power-Down mode and resume normal device operation, the Resume from Deep Power-
Down command must be issued. The Resume from Deep Power-Down command is the only command that the
device will recognized while in the Deep Power-Down mode.
To resume from the Deep Power-Down mode, the CS pin must first be asserted and opcode of ABh must be
clocked into the device. Any additional data clocked into the device after the opcode will be ignored. When the CS
pin is deasserted, the device will exit the Deep Power-Down mode within the maximum time of tRDPD and return to
the standby mode. After the device has returned to the standby mode, normal command operations such as Read
Array can be resumed.
If the complete opcode is not clocked in before the CS pin is deasserted, or if the CS pin is not deasserted on an
even byte boundary (multiples of eight bits), then the device will abort the operation and return to the Deep Power-
Down mode.
Figure 12-4. Resume from Deep Power-Down
SCK
CS
SI
SO
MSB
ICC
2310
10111001
6754
OPCODE
HIGH-IMPEDANCE
Standby Mode Current
Active Current
Deep Power-Down Mode Current
tEDPD
SCK
CS
SI
SO
MSB
ICC
2310
10101011
6754
OPCODE
HIGH-IMPEDANCE
Deep Power-Down Mode Current
Active Current
Standby Mode Current
tRDPD
41
8715E–SFLSH–11/2017
AT25DF081A
12.5 Hold
The HOLD pin is used to pause the serial communication with the device without having to stop or reset the clock
sequence. The Hold mode, however, does not have an affect on any internally self-timed operations such as a pro-
gram or erase cycle. Therefore, if an erase cycle is in progress, asserting the HOLD pin will not pause the
operation, and the erase cycle will continue until it is finished.
The Hold mode can only be entered while the CS pin is asserted. The Hold mode is activated simply by asserting
the HOLD pin during the SCK low pulse. If the HOLD pin is asserted during the SCK high pulse, then the Hold
mode won’t be started until the beginning of the next SCK low pulse. The device will remain in the Hold mode as
long as the HOLD pin and CS pin are asserted.
While in the Hold mode, the SO pin will be in a high-impedance state. In addition, both the SI pin and the SCK pin
will be ignored. The WP pin, however, can still be asserted or deasserted while in the Hold mode.
To end the Hold mode and resume serial communication, the HOLD pin must be deasserted during the SCK low
pulse. If the HOLD pin is deasserted during the SCK high pulse, then the Hold mode won’t end until the beginning
of the next SCK low pulse.
If the CS pin is deasserted while the HOLD pin is still asserted, then any operation that may have been started will
be aborted, and the device will reset the WEL bit in the Status Register back to the logical “0” state.
Figure 12-5. Hold Mode
SCK
CS
HOLD
Hold HoldHold
42
8715E–SFLSH–11/2017
AT25DF081A
13. RapidS Implementation
To implement RapidS and operate at clock frequencies higher than what can be achieved in a viable SPI imple-
mentation, a full clock cycle can be used to transmit data back and forth across the serial bus. The AT25DF081A is
designed to always clock its data out on the falling edge of the SCK signal and clock data in on the rising edge of
SCK.
For full clock cycle operation to be achieved, when the AT25DF081A is clocking data out on the falling edge of
SCK, the host controller should wait until the next falling edge of SCK to latch the data in. Similarly, the host con-
troller should clock its data out on the rising edge of SCK in order to give the AT25DF081A a full clock cycle to latch
the incoming data in on the next rising edge of SCK.
Implementing RapidS allows a system to run at higher clock frequencies since a full clock cycle is used to accom-
modate a device’s clock-to-output time, input setup time, and associated rise/fall times. For example, if the system
clock frequency is 100 MHz (10ns cycle time) with a 50% duty cycle, and the host controller has an input setup
time of 2ns, then a standard SPI implementation would require that the slave device be capable of outputting its
data in less than 3ns to meet the 2ns host controller setup time [(10ns x 50%) 2ns] not accounting for rise/fall
times. In an SPI mode 0 or 3 implementation, the SPI master is designed to clock in data on the next immediate ris-
ing edge of SCK after the SPI slave has clocked its data out on the preceding falling edge. This essentially makes
SPI a half-clock cycle protocol and requires extremely fast clock-to-output times and input setup times in order to
run at high clock frequencies. With a RapidS implementation of this example, however, the full 10ns cycle time is
available which gives the slave device up to 8ns, not accounting for rise/fall times, to clock its data out. Likewise,
with RapidS, the host controller has more time available to output its data to the slave since the slave device would
be clocking that data in a full clock cycle later.
Figure 13-1. RapidS Operation
SCK
MOSI
MISO
t
V
1234567812345678
MOSI = Master Out, Slave In MISO = Master In, Slave Out
The Master is the ASIC/MCU and the Slave is the memory device
The Master always clocks data out on the rising edge of SCK and always clocks data in on the falling edge of SCK
The Slave always clocks data out on the falling edge of SCK and always clocks data in on the rising edge of SCK
A. Master clocks out first bit of BYTE A on the rising edge of SCK
B. Slave clocks in first bit of BYTE A on the next rising edge of SCK
C. Master clocks out second bit of BYTE A on the same rising edge of SCK
D. Last bit of BYTE A is clocked out from the Master
E. Last bit of BYTE A is clocked into the slave
F. Slave clocks out first bit of BYTE B
G. Master clocks in first bit of BYTE B
H. Slave clocks out second bit of BYTE B
I. Master clocks in last bit of BYTE B
ABC D E
FG
1
H
BYTE A
MSB LSB
BYTE B
MSB LSB
Slave CS
I
43
8715E–SFLSH–11/2017
AT25DF081A
14. Electrical Specifications
14.1 Absolute Maximum Ratings*
14.2 DC and AC Operating Range
14.3 DC Characteristics
Temperature under Bias........................-55°C to +125°C *NOTICE: Stresses beyond those listed under “Abso-
lute Maximum Ratings” may cause perma-
nent damage to the device. This is a stress
rating only and functional operation of the
device at these or any other conditions
beyond those indicated in the operational
sections of this specification is not implied.
Exposure to absolute maximum rating con-
ditions for extended periods may affect
device reliability.
Storage Temperature.............................-65°C to +150°C
All Input Voltages
(including NC Pins)
with Respect to Ground............................-0.6V to +4.1V
All Output Voltages
with Respect to Ground....................-0.6V to VCC + 0.5V
AT25DF081A
Operating Temperature (Case) Ind. -40°C to 85°C
VCC Power Supply 2.7V to 3.6V
Symbol Parameter Condition Min Typ Max Units
ISB Standby Current CS, WP, HOLD = VCC,
all inputs at CMOS levels 25 50 µA
IDPD Deep Power-down Current CS, WP, HOLD = VCC,
all inputs at CMOS levels 510µA
ICC1 Active Current, Read Operation
f = 100MHz; IOUT = 0mA;
CS = VIL, VCC = Max 17 20
mA
f = 85MHz; IOUT = 0mA;
CS = VIL, VCC = Max 16 19
f = 66MHz; IOUT = 0mA;
CS = VIL, VCC = Max 15 18
f = 50MHz; IOUT = 0mA;
CS = VIL, VCC = Max 14 17
f = 33MHz; IOUT = 0mA;
CS = VIL, VCC = Max 13 16
f = 20MHz; IOUT = 0mA;
CS = VIL, VCC = Max 12 15
ICC2 Active Current, Program Operation CS = VCC, VCC = Max 10 15 mA
ICC3 Active Current, Erase Operation CS = VCC, VCC = Max 12 18 mA
ILI Input Leakage Current VIN = CMOS levels A
ILO Output Leakage Current VOUT = CMOS levels A
VIL Input Low Voltage 0.3 x VCC V
VIH Input High Voltage 0.7 x VCC V
VOL Output Low Voltage IOL = 1.6mA; VCC = Min 0.4 V
VOH Output High Voltage IOH = -100µA; VCC = Min VCC - 0.2V V
44
8715E–SFLSH–11/2017
AT25DF081A
14.4 AC Characteristics – Maximum Clock Frequencies
14.5 AC Characteristics – All Other Parameters
Notes: 1. Not 100% tested (value guaranteed by design and characterization)
2. 15pF load at frequencies above 70MHz, 30pF otherwise
3. Only applicable as a constraint for the Write Status Register Byte 1 command when SPRL = 1
Symbol Parameter Min Max Units
RapidS and SPI Operation
fMAX
Maximum Clock Frequency for All Operations – RapidS Operation Only
(excluding 0Bh, 03h, 3Bh, and 9F opcodes) 100 MHz
fCLK
Maximum Clock Frequency for All Operations
(excluding 03h and 3Bh opcodes) 85 MHz
fRDLF Maximum Clock Frequency for 03h Opcode (Read Array – Low Frequency) 50 MHz
fRDDO Maximum Clock Frequency for 3Bh Opcode (Dual-Output Read) 85 MHz
Symbol Parameter Min Max Units
tCLKH Clock High Time 4.3 ns
tCLKL Clock Low Time 4.3 ns
tCLKR(1) Clock Rise Time, Peak-to-Peak (Slew Rate) 0.1 V/ns
tCLKF(1) Clock Fall Time, Peak-to-Peak (Slew Rate) 0.1 V/ns
tCSH Chip Select High Time 50 ns
tCSLS Chip Select Low Setup Time (relative to Clock) 5 ns
tCSLH Chip Select Low Hold Time (relative to Clock) 5 ns
tCSHS Chip Select High Setup Time (relative to Clock) 5 ns
tCSHH Chip Select High Hold Time (relative to Clock) 5 ns
tDS Data In Setup Time 2 ns
tDH Data In Hold Time 1 ns
tDIS(1) Output Disable Time 5ns
tV(2) Output Valid Time 5ns
tOH Output Hold Time 2 ns
tHLS HOLD Low Setup Time (relative to Clock) 5 ns
tHLH HOLD Low Hold Time (relative to Clock) 5 ns
tHHS HOLD High Setup Time (relative to Clock) 5 ns
tHHH HOLD High Hold Time (relative to Clock) 5 ns
tHLQZ(1) HOLD Low to Output High-Z 5 ns
tHHQX(1) HOLD High to Output Low-Z 5 ns
tWPS(1)(3) Write Protect Setup Time 20 ns
tWPH(1)(3) Write Protect Hold Time 100 ns
tSECP(1) Sector Protect Time (from Chip Select High) 20 ns
tSECUP(1) Sector Unprotect Time (from Chip Select High) 20 ns
tLOCK(1) Sector Lockdown and Freeze Sector Lockdown State Time (from Chip Select High) 200 µs
tEDPD(1) Chip Select High to Deep Power-Down 1 µs
tRDPD(1) Chip Select High to Standby Mode 30 µs
tRST Reset Time 30 µs
45
8715E–SFLSH–11/2017
AT25DF081A
14.6 Program and Erase Characteristics
Notes: 1. Maximum values indicate worst-case performance after 100,000 erase/program cycles
2. Not 100% tested (value guaranteed by design and characterization)
14.7 Power-up Conditions
14.8 Input Test Waveforms and Measurement Levels
14.9 Output Test Load
Symbol Parameter Min Typ Max Units
tPP(1) Page Program Time (256-Bytes) 1.0 3.0 ms
tBP Byte Program Time 7 µs
tBLKE(1) Block Erase Time
4-Kbytes 50 200
ms32-Kbytes 250 600
64-Kbytes 400 950
tCHPE(1)(2) Chip Erase Time 16 28 sec
tOTPP(1) OTP Security Register Program Time 200 500 µs
tWRSR(2) Write Status Register Time 200 ns
Symbol Parameter Min Max Units
tVCSL Minimum VCC to Chip Select Low Time 100 µs
tPUW Power-up Device Delay Before Program or Erase Allowed 10 ms
VPOR Power-on Reset Voltage 1.5 2.5 V
AC
DRIVING
LEVELS
AC
MEASUREMENT
LEVEL
0.1V
CC
V
CC
/2
0.9V
CC
t
R
, t
F
< 2 ns (10% to 90%)
DEVICE
UNDER
TEST 15pF (frequencies above 70MHz)
or
30pF
46
8715E–SFLSH–11/2017
AT25DF081A
15. AC Waveforms
Figure 15-1. Serial Input Timing
Figure 15-2. Serial Output Timing
Figure 15-3. WP Timing for Write Status Register Byte 1 Command When SPRL = 1
CS
SI
SCK
SO
MSB
HIGH-IMPEDANCE
MSBLSB
tCSLS
tCLKH tCLKL tCSHS
tCSHH
tDS tDH
tCSLH
tCSH
CS
SI
SCK
SO
tV
tCLKH tCLKL tDIS
tV
tOH
WP
SI
SCK
SO
000
HIGH-IMPEDANCE
MSBX
tWPS tWPH
CS
LSB OF
WRITE STATUS REGISTER
DATA BYTE
MSB OF
WRITE STATUS REGISTER
BYTE 1 OPCODE
MSB OF
NEXT OPCODE
47
8715E–SFLSH–11/2017
AT25DF081A
Figure 15-4. HOLD Timing – Serial Input
Figure 15-5. HOLD Timing – Serial Output
CS
SI
SCK
SO
tHHH tHLS
tHLH tHHS
HOLD
HIGH-IMPEDANCE
CS
SI
SCK
SO
tHHH tHLS
tHLQZ
tHLH tHHS
HOLD
tHHQX
48
8715E–SFLSH–11/2017
AT25DF081A
16. Ordering Information
16.1 Code Detail Detail
16.2 Green Package Options (Pb/Halide-free/RoHS Compliant)
Note: The shipping carrier option code is not marked on the devices.
Designator
Product Family
Device Density
Interface
Shipping Carrier Option
Device Grade
Package Option
1 = Serial
8 = 8-megabit
B = Bulk (tubes)
Y = Bulk (trays)
T = Tape and reel
H = Green, NiPdAu lead finish, industrial
temperature range (-40°C to +85°C)
SS = 8-lead, 0.150" wide SOIC
S = 8-lead, 0.208" wide SOIC
M = 8-pad, 5 x 6 x 0.6mm UDFN
AT25DF081A-SSH-B
Ordering Code Package Lead (Pad) Finish Operating Voltage Max. Freq. (MHz) Operation Range
AT25DF081A-MH-Y
AT25DF081A-MH-T 8MA1
NiPdAu 2.7V to 3.6V 100 Industrial
(-40°C to +85°C)
AT25DF081A-SSH-B
AT25DF081A-SSH-T 8S1
AT25DF081A-SH-B
AT25DF081A-SH-T 8S2
Package Type
8MA1 8-pad (5 x 6 x 0.6 mm Body), Thermally Enhanced Plastic Ultra Thin Dual Flat No Lead Package (UDFN)
8S1 8-lead, 0.150” Wide, Plastic Gull Wing Small Outline Package (JEDEC SOIC)
8S2 8-lead, 0.208” Wide, Plastic Gull Wing Small Outline Package (EIAJ SOIC)
49
8715E–SFLSH–11/2017
AT25DF081A
17. Packaging Information
17.1 8MA1 – UDFN
TITLE DRAWING NO.GPC REV.
Package Drawing Contact:
contact@adestotech.com 8MA1 YFG D
8MA1, 8-pad (5 x 6 x 0.6 mm Body), Thermally
Enhanced Plastic Ultra Thin Dual Flat No Lead
Package (UDFN)
COMMON DIMENSIONS
(Unit of Measure = mm)
SYMBOL MIN NOM MAX N O T E
A 0.45 0.55 0.60
A1 0.00 0.02 0.05
b 0.35 0.40 0.48
C 0.152 REF
D 4.90 5.00 5.10
D2 3.80 4.00 4.20
E 5.90 6.00 6.10
E2 3.20 3.40 3.60
e 1.27
L 0.50 0.60 0.75
y 0.00 0.08
K 0.20 – –
4/15/08
Pin 1 ID
TOP VIEW
E
D
A1
A
SIDE VIEW
y
C
BOTTOM VIEW
E2
D2
L
b
e
1
2
3
4
8
7
6
5
Pin #1 Notch
(0.20 R)
0.45
K
Pin #1
Cham f e r
(C 0.35)
Option A
(Option B)
50
8715E–SFLSH–11/2017
AT25DF081A
17.2 8S1 – JEDEC SOIC
DRAWING NO. REV. TITLE GPC
COMMON DIMENSIONS
(Unit of Measure = mm)
SYMBOL MIN NOM MAX NOTE
A1 0.10 0.25
A 1.35 – 1.75
b 0.31 – 0.51
C 0.17 0.25
D 4.80 5.05
E1 3.81 3.99
E 5.79 – 6.20
e 1.27 BSC
L 0.40 – 1.27
ØØ
Ø
E
1
N
TOP VIEW
C
E1
END VIEW
A
b
L
A1
e
D
SIDE VIEW
Package Drawing Contact:
contact@adestotech.com
8S1 G
6/22/11
Notes: This drawing is for general information only.
Refer to JEDEC Drawing MS-012, Variation AA
for proper dimensions, tolerances, datums, etc.
8S1, 8-lead (0.150” Wide Body), Plastic Gull Wing
Small Outline (JEDEC SOIC) SWB
51
8715E–SFLSH–11/2017
AT25DF081A
17.3 8S2 – EIAJ SOIC
TITLE DRAWING NO. GPC REV.
Package Drawing Contact:
contact@adestotech.com
8S2 STN F
8S2, 8-lead, 0.208” Body, Plastic Small
Outline Package (EIAJ)
4/15/08
COMMON DIMENSIONS
(Unit of Measure = mm)
SYMBOL MIN NOM MAX NOTE
Notes: 1. This drawing is for general information only; refer to EIAJ Drawing EDR-7320 for additional information.
2. Mismatch of the upper and lower dies and resin burrs aren't included.
3. Determines the true geometric position.
4. Values b,C apply to plated terminal. The standard thickness of the plating layer shall measure between 0.007 to .021 mm.
A 1.70 2.16
A1 0.05 0.25
b 0.35 0.48 4
C 0.15 0.35 4
D 5.13 5.35
E1 5.18 5.40 2
E 7.70 8.26
L 0.51 0.85
q
e 1.27 BSC 3
qq
1 1
N N
E E
TOP VIEW TOP VIEW
C C
E1 E1
END VIEW END VIEW
A A
b b
L L
A1 A1
e e
D D
SIDE VIEW SIDE VIEW
52
8715E–SFLSH–11/2017
AT25DF081A
18. Revision History
Doc. Rev. Date Comments
8715E 11/2017 Added patent information.
8715D 8/2017 Updated corporate address.
8715C 1/2013 Update to Adesto logos. (11/2012)
Abbreviate title to SPI (1/2013)
8715B 08/2010 Change tRDPD Max from 10 to 30 in AC Parameters
8715A 06/2010 Initial document release
Corporate Office
California | USA
Adesto Headquarters
3600 Peterson Way
Santa Clara, CA 95054
Phone: (+1) 408.400.0578
Email: contact@adestotech.com
© 2017 Adesto Technologies. All rights reserved. / Rev.: 8715E–SFLSH–11/2017
Disclaimer: Adesto Technologies Corporation makes no warranty for the use of its products, other than those expressly contained in the Company's standard warranty which is detailed in Adesto's Terms
and Conditions located on the Company's web site. The Company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications
detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Adesto are granted by the
Company in connection with the sale of Adesto products, expressly or by implication. Adesto's products are not authorized for use as critical components in life support devices or systems.
Adesto®, the Adesto logo, CBRAM®, and DataFlash® are registered trademarks or trademarks of Adesto Technologies. All other marks are the property of their respective
owners. Adesto products in this datasheet are covered by certain Adesto patents registered in the United States and potentially other countries. Please refer to
http://www.adestotech.com/patents for details.