GND
(Circuit parameters)
CO
Ve
VO
GND
VCC
VOUT
R1
The circuit constant is a example. It is difference from mounting equipment. Please select it by your mounting equipment.
Please be carefully not to apply exceeding the absolute maximum ratings of applying voltage and continuous high voltage spike
3. Pay attention to a malfunction of the light detecting unit when the surface is stained with dust and refuse.
Care must be taken not to touch the light detector surface.
4. Unnecessary force shoud not be applied to terminal.
5. Do not push the light detector surface (photodiode) from outside.
■Precautions for Operation
t1t2t3tn
TON
Transmitting time for 1 block:T
1. When this infrared remote control detecting unit shall be adopted for wireless remote control, please use the following signal format .
(NEC code,RC-6code etc.)
・Total duty ratio Dt (Emitting time tN / Transmitting time for 1 block T) : 40% or less.
Σ
n
N=1
・ON signal time TON:200μs or more.
In case the signal format of total duty and/or ON/OFF signal time dosen`t meet the conditions noted above, there is a
case that reception distance much reduces or output dose not appear.
Dt=(
Σ
tN/T)×100(%)
n
N=1
2. Use the light emitting unit (remote control transmitter), in consideration of performance, characteristics, operating conditions of
light emitting device and the characteristics of the light detecting unit.
If it should be dirty, wipe off such dust and refuse with soft cloth so as to prevent scratch. In case some solvents are required, use
methyl alcohol, ethyl alcohol or isopropyl alcohol only.
Also, protect the light detecting unit against flux and others, since their deposition on the unit inside causes reduction of the
function, fading of markings such as the part number.
6. To avoid the electrostatic breakdown of IC, handle the unit under the condition of grounding with human body, soldering iron, etc.
7. Since conductive thermo plasticity is used in 2nd mold regin,please be careful not to come in contact with PCB land
pattern.
R1=47Ω±5%
C1=47μF
In setting R1 and C1, use suitable values after considering under the real condition
This device has a transistor as protection element between VCC and GND to improve anti-static electricity proof.
noise because there is cases that transistor will be short by secondary breakdown generally. In order to do difficultly, Please add CR
filter(47Ω(1/10W), 10μF or more)such as external circuit example above near VCC.
GP1UX51QS Series
8. External Circuit Examples (Mount the outer parts as near the unit as possible).
+