PA-20 www.recom-electronic.com
REV: 1/2010
RAC15-B
Please Read Application Notes
POWERLINE
AC/DC-Converter
with 3 year Warranty
UL-60601-1 Certified
E314885
RAC15-B
15 Watt
Single/Dual
&Triple
Output
Compact AC-DC Power Supply
15 Watt PCB Mount Package
Universal Input Voltage Range
4000VAC Isolation
Low Output Ripple and Noise
Short Circuit Protected
UL-60601 Certified for Medical Applications
Features
Regulated
Converters
Selection Guide
Part Input Output Output Efficiency
Number Range Voltage Current
(VAC) (VDC) (mA) (%)
RAC15-3.3SB 85-264 3.3 3000 74
RAC15-05SB 85-264 5 3000 78
RAC15-09SB 85-264 9 1666 79
RAC15-12SB 85-264 12 1250 81
RAC15-15SB 85-264 15 1000 81
RAC15-24SB 85-264 24 625 83
RAC15-05DB 85-264 ±5 ±1500 78
RAC15-12DB 85-264 ±12 ±625 80
RAC15-15DB 85-264 ±15 ±500 81
RAC15-0512TB 85-264 5/±12 +2000/±200 78
RAC15-0515TB 85-264 5/±15 +2000/±150 78
*add suffix “-E” for extended temperature range, e.g. RAC15-05SB-E
*add suffix "-ST” for screw terminal module e.g. RAC15-05SB-ST, RAC15-05DB-ST, RAC15-0512TB-ST
Input Voltage Range 90-264VAC or 100-370VDC
Rated Power 15 Watts max.
Input Frequency Range (for AC Input) 47-440Hz
Input Current (full load) 115VAC/230VAC 220mA / 118mA max.
No Load Power Consumption 115VAC/230VAC 590mW max.
Inrush Current (<2ms) 115VAC/230VAC 10A / 20A max.
Leakage Current 115VAC/230VAC 100µA/ 200µA max.
Output Voltage Accuracy (Full load) Single and Dual ±2% max.
Triple ±2% / ±3% max.
Line Voltage Regulation (low line, high line at full load) - See Note 1 ±0.5% max.
Load Voltage Regulation (10% to 100% symmetric load) - See Note 2 ±1% max.
Output Ripple and Noise - See Note 3 1% Vout max.
Operating Frequency 132kHz typ.
Efficiency at Full Load see table
RMS Isolation Voltage (input to output) 4kVAC / 1minute
Temperature Coefficient ±0.01%/°C typ.
Over-Current Protection 105% typ.
Short Circuit Protection Continuous, Automatic Restart
Over-Voltage Protection Zener Diode Clamp
Over-Temperature Protection 100°C
Operating Temperature Range Standard -25°C to +70°C
(free air convection, with derating) Suffix -E -40°C to +70°C
Storage Temperature Range -40°C to +100°C
continued on next page
Derating Graph
(Ambient Temperature)
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0
50
60 70 80 90
Output Power (%)
Natural Convection
-40
E-Version
Description
Specifications (typical at 25°C and after warm up time unless otherwise specified )
Compact switching power module for PCB or DIN-rail mounting with medical certification UL-60601-1.
RoHS
2002/95/EC
6/6
RAC15-B
www.recom-international.com PA-21
REV:1/2010
RAC15-S_D_TB
Series
POWERLINE
AC/DC-Converter
10.00
54.00
23.50
1
8
4
10.0
22.50
Bottom View
64.00 45.60
1.0
17.5
2
6
10.0
4.0 6.0
3
7
12.5 17.5
57.5
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
Pin # Single Out Dual Out Triple Out
1 VAC in (L) VAC in (L) VAC in (L)
2 VAC in (N) VAC in (N) VAC in (N)
3 -VDC out -VDC out +5V Ret.
4 No Pin Com -VDC out
5 No Pin No Pin +5V out
6 +VDC out +VDC out No Pin
7 No Pin No Pin Com
8 No Pin No Pin +VDC out
Note 1: Line Regulation = 2% max. for triple output +Vout and -Vout.
Note 2: Load Regulation = 5% max. for triple output +Vout and -Vout.
Note 3: Ripple & Noise measured with 20MHz BW probe and 0.1µF + 47µF capacitors in parallel across the outputs.
Note 4: Suggested input fuse rating = 2A Slow Blow
86.1
96.0
46.0
53.9
dia.3.5 x 4
1
2
3
4
5
6
7
8
Fuse
5.5
29.0
Removable DIN-Rail
Mounting Bracket
RAC15-xxS_D_TB
3rd angle
projection
Pin Connections
Pin # Single Out Dual Out Triple Out
1NCNCNC
2 VAC in (L) VAC in (L) VAC in (L)
3 VAC in (N) VAC in (N) VAC in (N)
4 NC NC +5V Ret.
5 -VDC Out -VDC Out +5V Out
6 NC Com -VDC out
7 +VDC out +VDC out Com
8 NC NC +VDC out
NC = No Connection
Notes
Package Style and Pinning
Case Material Epoxy with Fibreglass (UL94V-0)
Package Weight 120g
Packing Quantity 5 pcs (-ST Version: 1 pc)
EMC EN 55011 Class B / EN60601-1-2
MTBF (+25°C) using MIL-HDBK-217F 200~400 x 103hours
Specifications continued
3rd angle
projection
Screw Terminal Module Option (suffix -ST)