FET INPUT POWER OPERATIONAL AMPLIFIERS PA07 * PA07A HTTP://WWW.APEXMICROTECH.COM M I C R O T E C H N O L O G Y (800) 546-APEX (800) 546-2739 FEATURES * * * * * LOW BIAS CURRENT -- FET Input PROTECTED OUTPUT STAGE -- Thermal Shutoff EXCELLENT LINEARITY -- Class A/B Output WIDE SUPPLY RANGE -- 12V TO 50V HIGH OUTPUT CURRENT -- 5A Peak APPLICATIONS * * * * * * MOTOR, VALVE AND ACTUATOR CONTROL MAGNETIC DEFLECTION CIRCUITS UP TO 4A POWER TRANSDUCERS UP TO 100kHz TEMPERATURE CONTROL UP TO 180W PROGRAMMABLE POWER SUPPLIES UP TO 90V AUDIO AMPLIFIERS UP TO 60W RMS TYPICAL APPLICATION CL RL R F1 CF R CL+ +32V R F2 V = 28 EMF = 14V R W = 14 .68 PA07 DESCRIPTION The PA07 is a high voltage, high output current operational amplifier designed to drive resistive, inductive and capacitive loads. For optimum linearity, especially at low levels, the output stage is biased for class A/B operation using a thermistor compensated base-emitter voltage multiplier circuit. A thermal shutoff circuit protects against overheating and minimizes heatsink requirements for abnormal operating conditions. The safe operating area (SOA) can be observed for all operating conditions by selection of user programmable current limiting resistors. Both amplifiers are internally compensated for all gain settings. For continuous operation under load, a heatsink of proper rating is recommended. This hybrid circuit utilizes thick film (cermet) resistors, ceramic capacitors and semiconductor chips to maximize reliability, minimize size and give top performance. Ultrasonically bonded aluminum wires provide reliable interconnections at all operating temperatures. The 8-pin TO-3 package is hermetically sealed and electrically isolated. The use of compressible washers and/or improper mounting torque will void the product warranty. Please see "General Operating Considerations". EQUIVALENT SCHEMATIC 3 7 Q1 Q2 D1 Q3 +V -32V -V PD1 Position is sensed by the differentially connected photo diodes, a method that negates the time and temperature variations of the optical components. Off center positions produce an error current which is integrated by the op amp circuit, driving the system back to center position. A momentary switch contact forces the system out of lock and then the integrating capacitor holds drive level while both diodes are in a dark state. When the next index point arrives, the lead network of C1 and R1 optimize system response by reducing overshoot. The very low bias current of the PA07 augments performance of the integrator circuit. Q6B Q7 1 C3 Q10 5 4 Q12A Q11 +IN OUT 1 OUTPUT 4 TOP VIEW Q19 8 C4 D3 Q12B 2 3 RT Q17B RS -IN R CL- 5 8 CL- Q17A Q15 Q16 Q18 R CL+ CL+ +VS 2 C2 PD2 Negates optoelectronic instabilities Lead network minimizes overshoot SEQUENTIAL POSITION CONTROL Q6A Q4 Q9 LIGHT .68 EXTERNAL CONNECTIONS C1 Q5 Q8 MOTOR R CL- 6 -VS 7 BAL RS= ( VS+ + -VS ) RT/1.6 D2 6 NOTE: Input offset voltage trim optional. RT = 10K MAX 8-pin TO-3 package APEX MICROTECHNOLOGY CORPORATION * TELEPHONE (520) 690-8600 * FAX (520) 888-3329 * ORDERS (520) 690-8601 * EMAIL prodlit@apexmicrotech.com ABSOLUTE MAXIMUM RATINGS SPECIFICATIONS PA07 * PA07A SUPPLY VOLTAGE, +VS to -VS OUTPUT CURRENT, within SOA POWER DISSIPATION, internal1 INPUT VOLTAGE, differential INPUT VOLTAGE, common mode TEMPERATURE, pin solder - 10s TEMPERATURE, junction1 TEMPERATURE RANGE, storage OPERATING TEMPERATURE RANGE, case ABSOLUTE MAXIMUM RATINGS SPECIFICATIONS PARAMETER 100V 5A 67W 50V VS 300C 200C -65 to +150C -55 to +125C PA07 TEST CONDITIONS 2 MIN PA07A TYP MAX .5 10 8 20 5 .01 2.5 1011 4 2 30 MIN TYP MAX UNITS .25 5 * 10 3 * 1.5 * * .5 10 * mV V/C V/V V/W pA pA/V pA pF V dB * * * * dB MHz kHz INPUT OFFSET VOLTAGE, initial OFFSET VOLTAGE, vs. temperature OFFSET VOLTAGE, vs. supply OFFSET VOLTAGE, vs. power BIAS CURRENT, initial3 BIAS CURRENT,vs. supply OFFSET CURRENT, initial3 INPUT IMPEDANCE, DC INPUT CAPACITANCE COMMON MODE VOLTAGE RANGE4 COMMON MODE REJECTION, DC TC = 25C Full temperature range TC = 25C Full temperature range TC = 25C TC = 25C TC = 25C TC = 25C TC = 25C Full temperature range VS-10 Full temperature range, VCM = 20V 50 50 10 10 * 120 GAIN OPEN LOOP GAIN at 10Hz TC = 25C, RL = 15 GAIN BANDWIDTH PRODUCT @ 1MHz TC = 25C, RL = 15 POWER BANDWIDTH TC = 25C, RL = 15 PHASE MARGIN Full temperature range, RL = 15 92 98 1.3 18 70 * OUTPUT VOLTAGE SWING4 VOLTAGE SWING4 VOLTAGE SWING4 CURRENT, peak SETTLING TIME to .1% SLEW RATE CAPACITIVE LOAD, unity gain CAPACITIVE LOAD, gain>4 Full temp. range, IO = 5A Full temp. range, IO = 2A Full temp. range, IO = 90mA TC = 25C TC = 25C, 2V step TC = 25C Full temperature range Full temperature range VS-5 VS-5 VS-5 5 * * * * 1.5 5 * * 10 SOA * * V V V A s V/s nF POWER SUPPLY VOLTAGE CURRENT, quiescent Full temperature range TC = 25C 12 35 18 50 30 1.9 2.4 30 25 2.1 2.6 * * * * * V mA * * * * * * C/W C/W C/W C THERMAL RESISTANCE, AC, junction to case5 RESISTANCE, DC, junction to case RESISTANCE, junction to air TEMPERATURE RANGE, case NOTES: * 1. 2. 3. 4. 5. CAUTION F>60Hz F<60Hz Meets full range specifications -25 +85 * * The specification of PA07A is identical to the specification for PA07 in applicable column to the left. Long term operation at the maximum junction temperature will result in reduced product life. Derate internal power dissipation to achieve high MTTF. The power supply voltage for all specifications is the TYP rating unless otherwise noted as a test condition. Doubles for every 10C of temperature increase. +VS and -VS denote the positive and negative supply rail respectively. Total VS is measured from +VS to -VS. Rating applies if the output current alternates between both output transistors at a rate faster than 60Hz. The internal substrate contains beryllia (BeO). Do not break the seal. If accidentally broken, do not crush, machine, or subject to temperatures in excess of 850C to avoid generating toxic fumes. APEX MICROTECHNOLOGY CORPORATION * 5980 NORTH SHANNON ROAD * TUCSON, ARIZONA 85741 * USA * APPLICATIONS HOTLINE: 1 (800) 546-2739 T = TC 50 40 30 20 10 T = TA 0 0 20 40 60 80 100 120 140 TEMPERATURE, TC (C) 4 1 .25 .06 -15 -60 PHASE, () 80 40 20 0 2.5 1.5 1.0 .5 0 0 25 75 100 -50 -25 50 CASE TEMPERATURE, TC (C) POWER RESPONSE 100 -150 -180 -210 80 60 40 20 VIN = 5V, t r = 100ns 6 4 2 0 -2 -4 -6 -8 0 10 100 1K 10K .1M FREQUENCY, F (Hz) 1M HARMONIC DISTORTION 10 G =10 .01 100 8 = = L ,R 6V L L 5V 3 S = S P .03 O = P O 60 = 50 .1 W ,V P W O = ,V .3 = 50 m 2 W ,R 1 ,R = 8 4 3 300 1K 3K 10K 30K .1M FREQUENCY, F (Hz) 0 NORMALIZED QUIESCENT CURRENT, I Q (X) 1 2 4 6 8 10 12 TIME, t (s) QUIESCENT CURRENT 1.6 1.4 T C = -25C 1.2 1.0 .8 .6 T C = 25C TC = 85C C T C = 125 .4 50 60 70 80 90 100 40 TOTAL SUPPLY VOLTAGE, VS (V) INPUT NOISE VOLTAGE, VN (nV/ Hz) PULSE RESPONSE |+VS | + |-VS | = 70V 46 32 22 15 10 6.8 4.6 10K 10 100 1K 10K .1M 1M 10M FREQUENCY, F (Hz) 8 |+VS | + |-VS | = 100V 68 20K 30K 50K 70K .1M FREQUENCY, F (Hz) INPUT NOISE 20 10 VOLTAGE DROP FROM SUPPLY, VSAT (V) 1 COMMON MODE REJECTION 100 R CL = 0.6 PHASE RESPONSE -120 10 100 1K 10K .1M 1M 10M FREQUENCY, F (Hz) R CL = 0.3 2.0 105 -90 OUTPUT VOLTAGE, VO (VPP ) 120 25 5 45 65 85 TEMPERATURE, T C (C) 0 -30 1 COMMON MODE REJECTION, CMR (dB) 16 100 -20 DISTORTION, THD (%) 64 SMALL SIGNAL RESPONSE 60 CURRENT LIMIT 3.0 CURRENT LIMIT, I LIM (A) 60 BIAS CURRENT 256 OUTPUT VOLTAGE, VO (VPP ) POWER DERATING 70 120 OPEN LOOP GAIN, A OL (dB) PA07 * PA07A NORMALIZED BIAS CURRENT, I B (X) INTERNAL POWER DISSIPATION, P(W) TYPICAL PERFORMANCE GRAPHS 6 4 2 10 100 10K 1K FREQUENCY, F (Hz) .1M OUTPUT VOLTAGE SWING 6 5 TC= C -25 4 25C TC = 3 85C TC = 2 1 0 0 2 3 4 1 5 OUTPUT CURRENT, I O (A) 6 APEX MICROTECHNOLOGY CORPORATION * TELEPHONE (520) 690-8600 * FAX (520) 888-3329 * ORDERS (520) 690-8601 * EMAIL prodlit@apexmicrotech.com OPERATING CONSIDERATIONS PA07 * PA07A GENERAL Please read Application Note 1 "General Operating Considerations" which covers stability, supplies, heat sinking, mounting, current limit, SOA interpretation, and specification interpretation. Visit www.apexmicrotech.com for design tools that help automate tasks such as calculations for stability, internal power dissipation, current limit; heat sink selection; Apex's complete Application Notes library; Technical Seminar Workbook; and Evaluation Kits. 2. The amplifier can handle any reactive or EMF generating load and short circuits to the supply rail or common if the current limits are set as follows at TC = 85C: SAFE OPERATING AREA (SOA) The output stage of most power amplifiers has three distinct limitations: 1. The current handling capability of the wire bonds. 2. The second breakdown effect which occurs whenever the simultaneous collector current and collector-emitter voltage exceed specified limits. 3. The junction temperature of the output transistors. OUTPUT CURRENT FROM +VS OR - VS (A) 5.0 4.0 3.0 2.0 1.5 1.0 Tc =8 Tc =1 TH ste 5C 25 ER C MA L ad ys t= ta te SE 5m CO s ND t= t= 1m 0 . 5 s ms BR EA KD .8 OW N .6 .4 .3 .2 10 15 20 25 30 35 40 50 60 70 80 100 SUPPLY TO OUTPUT DIFFERENTIAL VOLTAGE VS - VO (V) VS SHORT TO VS C, L, OR EMF LOAD SHORT TO COMMON 50V 40V 30V 20V 15V .21A .3A .46A .87A 1.4A .61A .87A 1.4A 2.5A 4.0A These simplified limits may be exceeded with further analysis using the operating conditions for a specific application. 3. The output stage is protected against transient flyback. However, for protection against sustained, high energy flyback, external fast-recovery diodes should be used. THERMAL SHUTDOWN PROTECTION The thermal protection circuit shuts off the amplifier when the substrate temperature exceeds approximately 150C. This allows heatsink selection to be based on normal operating conditions while protecting the amplifier against excessive junction temperature during temporary fault conditions. Thermal protection is a fairly slow-acting circuit and therefore does not protect the amplifier against transient SOA violations (areas outside of the TC = 25C boundary). It is designed to protect against short-term fault conditions that result in high power dissipation within the amplifier. If the conditions that cause thermal shutdown are not removed, the amplifier will oscillate in and out of shutdown. This will result in high peak power stresses, will destroy signal integrity and reduce the reliability of the device. SAFE OPERATING AREA CURVES CURRENT LIMIT The SOA curves combine the effect of these limits. For a given application, the direction and magnitude of the output current should be calculated or measured and checked against the SOA curves. This is simple for resistive loads but more complex for reactive and EMF generating loads. However, the following guidelines may save extensive analytical efforts. Proper operation requires the use of two current limit resistors, connected as shown in the external connections diagram. The minimum value for RCL is .12, however, for optimum reliability it should be set as high as possible. Refer to the "General Operating Considerations" section of the handbook for current limit adjust details. 1. For DC outputs, especially those resulting from fault conditions, check worst case stress levels against the new SOA graph. For sine wave outputs, use Power Design1 to plot a load line. Make sure the load line does not cross the 0.5ms limit and that excursions beyond any other second breakdown line do not exceed the time label, and have a duty cycle of no more than 10%. For other waveform outputs, manual load line plotting is recommended. Applications Note 22, SOA AND LOAD LINES, will be helpful. A Spice type analysis can be very useful in that a hardware setup often calls for instruments or amplifiers with wide common mode rejection ranges. 1 Note 1. Power Design is a self-extracting Excel spreadsheet available free from www.apexmicrotech.com This data sheet has been carefully checked and is believed be reliable, however, no responsibility assumed forARIZONA possible inaccuracies All specifications are subject to change without notice. APEX MICROTECHNOLOGY CORPORATION * to 5980 NORTH SHANNON ROAD *isTUCSON, 85741 or * omissions. USA * APPLICATIONS HOTLINE: 1 (800) 546-2739 PA07U REV. L FEBRUARY 2001 (c) 2001 Apex Microtechnology Corp.