FRAME4/home/SMC-Allg/Datenblaetter/KO-dt-eng/DA-B82442H-e_2-98 EMC Components RF Chokes High Current B82442-H Data Book Supplement RF Chokes SIMID 05 Series - High Current B82442-H SIMID 05 (Siemens-Miniature-Inductors) Rated inductance 1 to 10000 H Rated current 0,035 to 2,5 A Construction Size as EIA standard: 2220 Upright ferrite drum core Laser welded, encapsulation flame retardant Temperature index of copper wire enamel: 180C Features FRAME4/home/SMC-Allg/Datenblaetter/KO-dt-eng/DA-B82442H-e_2-98 Very high rated current High L values Suitable for reflow (IR and vapor phase) and wave soldering Applications Filtering of supply voltages, coupling, decoupling DC/DC converters Automotive electronics Telecommunication Terminals Tinned Base material CuSn6; 0,4 m Cu; 1-2 m Ag; 5-7 m Sn No leaching during wave soldering Marking Marking on component: Manufacturer, date code, L value and tolerance of L value (coded) Minimum marking on reel: Manufacturer, part number, ordering code, L value and tolerance of L value, quantity, date of packing Delivery mode Blister tape 12 mm, reel packing dia. 330 mm. For details on taping, packing and packing units refer to data book "EMC Components", page 433. 2 3.98 Siemens Matsushita Components RF Chokes SIMID 05 Series - High Current B82442-H Dimensional drawing FRAME4/home/SMC-Allg/Datenblaetter/KO-dt-eng/DA-B82442H-e_2-98 Size as per EIA standard: 2220 Approx. weight 400 mg PCB layout recommendation Dimensions (mm) A B C D Wave/reflow soldering 4,5 2,0 4,0 8,0 1) Soldering area, tinned Siemens Matsushita Components 3.98 3 RF Chokes SIMID 05 Series - High Current B82442-H Technical data and ordering codes FRAME4/home/SMC-Allg/Datenblaetter/KO-dt-eng/DA-B82442H-e_2-98 For further technical data see page 7. LR H Tolerance Qmin f L; f Q MHz IR A Rmax fres, min MHz Ordering code 1) 1,0 1,2 1,5 10 % = K 10 10 10 7,96 7,96 7,96 2,50 2,35 2,20 0,024 0,028 0,032 95 70 55 B82442-H1102-K B82442-H1122-K B82442-H1152-K 1,8 2,2 2,7 10 10 10 7,96 7,96 7,96 2,00 1,80 1,70 0,040 0,048 0,056 47 42 37 B82442-H1182-K B82442-H1222-K B82442-H1272-K 3,3 3,9 4,7 10 10 10 7,96 7,96 7,96 1,55 1,45 1,35 0,064 0,072 0,088 34 32 29 B82442-H1332-K B82442-H1392-K B82442-H1472-K 5,6 6,8 8,2 10 10 10 7,96 7,96 7,96 1,25 1,13 1,05 0,104 0,120 0,144 26 24 22 B82442-H1562-K B82442-H1682-K B82442-H1822-K 10 12 15 10 10 10 2,52 2,52 2,52 1,00 0,88 0,81 0,168 0,20 0,24 19 17 16 B82442-H1103-K B82442-H1123-K B82442-H1153-K 18 22 27 10 10 10 2,52 2,52 2,52 0,74 0,67 0,62 0,29 0,35 0,42 14 13 11,5 B82442-H1183-K B82442-H1223-K B82442-H1273-K 10 10 10 2,52 2,52 2,52 0,56 0,52 0,48 0,50 0,58 0,68 10,5 9,5 8,5 B82442-H1333-+ B82442-H1393-+ B82442-H1473-+ 10 10 10 2,52 2,52 2,52 0,43 0,40 0,38 0,80 0,96 1,12 7,8 7,0 6,4 B82442-H1563-+ B82442-H1683-+ B82442-H1823-+ 33 39 47 56 68 82 5% = J 10 % = K 1) Replace the + by the code letter for the required inductance tolerance. 4 3.98 Siemens Matsushita Components RF Chokes SIMID 05 Series - High Current B82442-H Technical data and ordering codes For further technical data see page 7. LR H Tolerance Qmin f L; f Q MHz IR A Rmax fres, min MHz Ordering code 1) 100 120 150 5% = J 20 20 20 0,796 0,796 0,796 0,35 0,32 0,29 1,28 1,52 1,76 6,0 5,4 4,8 B82442-H1104-+ B82442-H1124-+ B82442-H1154-+ 20 20 20 0,796 0,796 0,796 0,27 0,24 0,22 2,24 2,72 3,36 4,4 3,9 3,6 B82442-H1184-+ B82442-H1224-+ B82442-H1274-+ 330 390 470 20 20 20 0,796 0,796 0,796 0,20 0,18 0,17 3,92 4,64 5,60 3,2 2,9 2,6 B82442-H1334-+ B82442-H1394-+ B82442-H1474-+ 560 680 820 20 20 20 0,796 0,796 0,796 0,15 0,14 0,13 6,80 8,00 10,4 2,4 2,2 2,0 B82442-H1564-+ B82442-H1684-+ B82442-H1824-+ 1000 1200 1500 30 30 30 0,252 0,252 0,252 0,120 0,105 0,100 12,0 13,6 16,0 1,8 1,5 1,4 B82442-H1105-+ B82442-H1125-+ B82442-H1155-+ 1800 2200 2700 30 30 30 0,252 0,252 0,252 0,085 0,075 0,065 24,0 28,0 44,0 1,3 1,2 1,1 B82442-H1185-+ B82442-H1225-+ B82442-H1275-+ 3300 3900 4700 30 30 30 0,252 0,252 0,252 0,055 0,053 0,050 48,0 56,0 62,4 1,0 1,0 0,9 B82442-H1335-+ B82442-H1395-+ B82442-H1475-+ 5600 6800 8200 30 30 30 0,252 0,252 0,252 0,046 0,042 0,039 68,0 88,0 100 0,8 0,7 0,6 B82442-H1565-+ B82442-H1685-+ B82442-H1825-+ 10000 30 0,0796 0,035 120 0,5 B82442-H1106-+ FRAME4/home/SMC-Allg/Datenblaetter/KO-dt-eng/DA-B82442H-e_2-98 180 220 270 10 % = K 1) Replace the + by the code letter for the required inductance tolerance. Siemens Matsushita Components 3.98 5 FRAME4/home/SMC-Allg/Datenblaetter/KO-dt-eng/DA-B82442H-e_2-98 RF Chokes SIMID 05 Series - High Current B82442-H Impedance |Z | versus frequency f measured with impedance analyzer HP 4194A/HP 4191A Inductance L versus dc load IDC measured with LCR meter HP 4275A Q factor versus frequency f measured with impedance analyzer HP 4194A Current derating Iop/IR versus ambient temperature TA (Rated temperature TR = 85C) 6 3.98 Siemens Matsushita Components RF Chokes SIMID 05 Series - High Current B82442-H FRAME4/home/SMC-Allg/Datenblaetter/KO-dt-eng/DA-B82442H-e_2-98 General technical data Rated inductance LR Measured at frequency fL, with impedance analyzer HP 4194A Q factor Qmin Measured at frequency fQ, with impedance analyzer HP 4194A Rated current IN Maximum permissible dc with an inductance decrease of L/L0 10 % and/or temperature increase of 40 K at rated temperature TR = 85C (see derating curves) Self resonance frequency fres, min Measured with network analyzer HP 8753D DC resistance Rmax Measured at 20C ambient temperature, Measuring current < IR Climatic category In accordance with IEC 68-1 55/125/56 (- 55C/+ 125C/56 days damp heat test) Solderability (215 3)C, (3 0,3) s Wetting of soldering area: 90 % Resistance to soldering heat In accordance with IEC 68-2-20, test Tb 260C, 10 s Permissible PCB bending 2 mm (100 mm long standard PCB) Published by Siemens Matsushita Components GmbH & Co. KG Marketing Kommunikation, Postfach 80 17 09, D-81617 Munchen Siemens Matsushita Components 1998. All Rights Reserved. As far as patents or other rights of third parties are concerned, liability is only assumed for components per se, not for applications, processes and circuits implemented within components or assemblies. The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of Siemens AG, Passive Components and Electron Tubes Group, in the Federal Republic of Germany or the international Siemens Companies and Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. Siemens Matsushita Components 3.98 7