PL IA NT CO M Features Applications Ultra-low resistance Battery packs *R oH S Small size Alternative shapes and sizes available on request Agency recognition RoHS compliant* MF-LL Series - PTC Resettable Fuse Electrical Characteristic V max. Volts Model MF-LL190 6 Typical Current Trip Limit I max. Amps Initial Resistance Values Amperes At 23 C 50 1 Hour (R1) Post-Trip Resistance mOhms At 23 C Max. Time To Trip mOhms At 23 C Amperes At 23 C Hold Trip Min. Max. Min. Max. 1.9 4.9 5 15 5 24 Tripped Power Dissipation Seconds At 23 C Watts At 23 C Typ. 9.5 2.0 1.0 Environmental Characteristics Operating/Storage Temperature .......................-40 C to +85 C Maximum Device Surface Temperature in Tripped State ................................................+125 C Storage Conditions ..........................................+40 C Max., 70 % RH Max., Packed in original packaging Test Procedures And Requirements For Model MF-LL Series Test Test Conditions Accept/Reject Criteria Humidity Aging ................................................. +60 C, 95 % R.H., 1000 Hours...........Typical resistance change +30 % to -30 % Passive Aging ................................................... +60 C, 1000 Hours .............................Typical resistance change +20 % to -20 % Low temp storage ............................................ -40 C, 1000 Hours ..............................Typical resistance change +5 % to -5 % Thermal Shock ................................................. +85 C to -40 C, 10 times...................Typical resistance change +5 % to -5 % Vibration ........................................................... MIL-STD-883D, Method 2026 .............Rmin