67www.burgess-switch.comburgess-switch@johnsonelectric.omBurgess switches
Forced break
XP
Basic type XP Momentary
XPS Positive action forced break (normally closed only)
Circuit 2 Change-over
4 Normally closed
5 Normally open
Terminals 2 Faston 6,3 • 0,8
Actuators No symbol, straight plunger
E1 Mushroom plunger with reset spring
E2 Mushroom plunger
Approvals Z11 UL, cUL, CSA and ENEC
Ordering Reference
Operating Characteristics
Actuating Release Free Operating Total Travel Over
Actuator Reference Force Force Position Position Position travel
Maximum Minimum Maximum Maximum
(N) (ozf) (N) (ozf) (mm) (in) (mm) (in) (mm) (in) (mm) (in)
Straight plunger XP2Z11 3,00 10,0 5,5 19,7 15,3 0,602 14,9 ± 0.4 0,587 ± 0.016 8,0 0,315 4,5 0,177
XP42Z11 1,75 6,20 5,5 19,7 15,3 0,602 14,9 ± 0.4 0,587 ± 0.016 8,0 0,315 6,5 0,256
XP52Z11 3,00 10,0 5,5 19,7 16,6 0,653 13,0 ± 0.4 0,511 ± 0.016 8,0 0,315 4,5 0,177
Mushroom XP2E1Z11 6,5 23,3 9,0 32,3 15,3 0,602 14,9 ± 0.4 0,587 ± 0.016 10,5 0,413 2,1 0,082
plunger with XP42E1Z11 3,75 13,4 9,0 32,3 15,3 0,602 14,9 ± 0.4 0,587 ± 0.016 10,5 0,413 4,0 0,157
reset spring XP52E1Z11 6,5 23,3 9,0 32,3 16,6 0,653 13,0 ± 0.4 0,511 ± 0.016 10,5 0,413 2,1 0,082
Mushroom plunger XP2E2Z11 3,0 10,0 5,5 19,7 15,3 0,602 14,9 ± 0.4 0,587 ± 0.016 8,6 0,339 4,0 0,157
Full overtravel Position
Operating Position
Rest Position