55
1413
5
9
2
6
10
3
7
11
4
8
12
20.7
27.7
1.5
4.1
6.35
4.2
6.35
1
9
13 14
5
A1 A2
2
10
6 3
11
7 4
12
8
4.4
1
4.4 4.4
2
5
8
20.7
31
66
97
1413
27.7
1.5
4.1
6.35
6.6
4.2
6.6
6.35
1
7
13 14
4
A1 A2
2
8
5 3
9
6
20.7
41
85
129
1413
27.7
1.5
4.1
6.35
13.2
4.2
6.35
1
9
13 14
5
A1 A2
4
12
8
2 CO 3 CO 4 CO
10/20 10/20 7/15
250/400 250/400 250/250
2,500 2,500 1,750
500 500 350
0.37 0.37 0.125
10/0.25/0.12 10/0.25/0.12 7/0.25/0.12
300 (5/5) 300 (5/5) 300 (5/5)
AgNi AgNi AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1 1.5/1 1.5/1
(0.8…1.1)UN(0.8…1.1)UN(0.8…1.1)UN
(0.8…1.1)UN(0.8…1.1)UN(0.8…1.1)UN
0.8 UN/0.5 UN0.8 UN/0.5 UN0.8 UN/0.5 UN
0.2 UN/0.1 UN0.2 UN/0.1 UN0.2 UN/0.1 UN
20 · 106/50 · 10620 · 106/50 · 10620 · 106/50 · 106
200 · 103200 · 103150 · 103
9/3 9/3 9/3
3.6 kV/2 3.6 kV/2 2.5 kV/2
3.6 3.6 3.6
1,000 1,000 1,000
–40…+85 –40…+85 –40…+85
RT IRT IRT I
55.12 55.13 55.14
h = 35.8 mm h = 35.8 mm
h = 35.8 mm
55 Series - Miniature General Purpose Relays 7 -10 A
-2 pole, 10 A
-P.C.B. mounting -3 pole, 10 A
-P.C.B. mounting -4 pole, 7 A
-P.C.B. mounting
CUS
®
GOST
RINA
Contact specifications
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load in AC1 VA
Rated load in AC15 (230 VAC) VA
Single phase motor rating (230 VAC) kW
Breaking capacity in DC1: 30/110/220V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specifications
Nominal voltage (UN)V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation according to EN 61810-5
Insulation between coil and contacts
(1.2/50µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals:
(according to type)
-P.C.B. versions
-AC or DC coils
-Lockable test button and mechanical flag
indicator as standard on 2 and 4 CO
relays types
-Sockets and accessories: see 94, 99 and
86 series
-RTIII (wash tight) version available
43
Copper side view Copper side view Copper side view
C
E
R
T
I
F
I
C
A
C
I
O
N
D
E
C
O
N
F
O
R
M
I
D
A
D
D
E
L
A
F
A
B
R
I
C
A
C
I
O
N
2 CO 3 CO 4 CO
10/20 10/20 7/15
250/400 250/400 250/250
2,500 2,500 1,750
500 500 350
0.37 0.37 0.125
10/0.25/0.12 10/0.25/0.12 7/0.25/0.12
300 (5/5) 300 (5/5) 300 (5/5)
AgNi AgNi AgNi
6 - 12- 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
1.5/1 1.5/1 1.5/1
(0.8…1.1)UN(0.8…1.1)UN(0.8…1.1)UN
(0.8…1.1)UN(0.8…1.1)UN(0.8…1.1)UN
0.8 UN/0.5 UN0.8 UN/0.5 UN0.8 UN/0.5 UN
0.2 UN/0.1 UN0.2 UN/0.1 UN0.2 UN/0.1 UN
20 · 106/50 · 10620 · 106/50 · 10620 · 106/50 · 106
200 · 103200 · 103150 · 103
9/3 9/3 9/3
3.6 kV/2 3.6 kV/2 2.5 kV/2
3.6 3.6 3.6
1,000 1,000 1,000
–40…+85 –40…+85 –40…+85
RT IRT IRT I
44
20.7 27.7
37.2
5.6
4.4 6.35 4.1 4.2
4.44.4 6.35
1
9
13 14
5
A1 A2
26
10
37
11
48
12
20.7 27.7
37.2
5.6
6.35 4.1 4.2
6.6
6.6
6.35
13 14
A1 A2
14
7
25
8
36
9
20.7 27.7
37.2
5.6
6.35 4.1 4.2
13.2
6.35
13 14
A1 A2
15
9
48
12
55.32 55.33 55.34
55 Series - Miniature General Purpose Relays 7 -10 A
- 2 pole, 10 A
- Plug-in for use with 94 Series
sockets
- 3 pole, 10 A
- Plug-in for use with 94 Series
sockets
- 4 pole, 7 A
- Plug-in for use with 94 Series
sockets
Contact specifications
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load in AC1 VA
Rated load in AC15 (230 VAC) VA
Single phase motor rating (230 VAC) kW
Breaking capacity in DC1: 30/110/220V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specifications
Nominal voltage (UN)V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation according to EN 61810-5
Insulation between coil and contacts
(1.2/50µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals:
(according to type)
-Plug-in versions
-AC or DC coils
-Lockable test button and mechanical flag
indicator as standard on 2 and 4 CO
relays types
-Sockets and accessories: see 94, 99 and
86 series
55
CUS
®
GOST
RINA
C
E
R
T
I
F
I
C
A
C
I
O
N
D
E
C
O
N
F
O
R
M
I
D
A
D
D
E
L
A
F
A
B
R
I
C
A
C
I
O
N
55
45
Example: a 55 series plug-in relay, 4 CO contacts, coil rated 12 V DC with a lockable test button and mechanical indicator.
coil version A B C D
55.32/34 AC/DC 0 - 2 - 5 0 0 0 - 6
AC 0 - 2 - 5 0 2 - 3 - 4 - 5 0 - 6
AC 0 - 2 - 5 0 54 /
DC 0 - 2 - 5 0 2 - 4 - 6 - 7 - 8 - 9 0 - 6
DC 0 - 2 - 5 0 74 - 94 /
55.33 AC/DC 0 - 2 - 5 0 0 0 - 6
AC 0 - 2 - 5 0 1 - 3 - 5 0 - 6
DC 0 - 2 - 5 0 1 - 6 - 7 - 8 - 9 0 - 6
55.12/13/14
AC/DC 0 - 2 - 5 0 0 0 - 1
55 Series - Miniature General Purpose Relays 7 -10 A
Option = 0080
0090
0094
Option = 0006
REAR FLANGE MOUNT
A: Contact material
0 = Standard AgNi
2 = AgCdO
5 = AgNi + 5µm Au
B: Contact circuit
0 = CO
Series
Type
1 = P.C.B.
3 = Plug-in
No. of poles
2 = 2 pole, 10 A
3 = 3 pole, 10 A
4 = 4 pole, 7 A
Coil version
8 = AC (50/60 Hz)
9 = DC
Coil voltage
see coil specifications
3 4 0 09
D: Special versions
0 = Standard
1 = Wash tight (RT III)
for 55.12, 55.13 and 55.14 only
6 = Rear flange mount
C: Options
0 = None
1 = Lockable test button
2 = Mechanical indicator
3 = LED (AC)
4 =
Lockable test button + mechanical indicator
5 = Lockable test button + LED (AC)
54 = Lockable test button + LED (AC)
+ mechanical indicator
6 = Double LED (DC not polarized)
7 =
Lockable test button + double LED
(DC not polarized)
74 =
Lockable test button + double LED
(DC not polarized)
+ mechanical indicator
8 = LED + diode (positive to pin A1/13,
DC standard polarity)
9 =
Lockable test button + LED + diode (positive
to pin A1/13, DC standard polarity)
94 =
Lockable test button + LED + diode (positive
to pin A1/13, DC standard polarity)
+ mechanical indicator
4 0
ORDERING INFORMATION
POSSIBLE OPTIONS
DC - Not polarized
AC DC - Standard polarity
Only combinations in the same row are possible
Preferred versions
All versions
Option = 0030
0050
0054
Option = 0060
0070
0074
ABCD
coil version A B C D
55.32/34
AC/DC 0 0 4 0
55.12/13/14
AC/DC 0 0 0 0
55.33
AC/DC 0 0 0 0
... .
01255
LOCKABLE TEST BUTTON AND
MECHANICAL FLAG INDICATOR (0040)
The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the
test button is pushed, the contacts operate. When the test button is released the contacts retur n to their
former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to
the above function), when the test button is pushed and rotated, the contacts are latched in the
operating state, and remain so until the test button is rotated back to its former position.
In both cases ensure that the test button actuation is swift and decisive.
41.9
3.6
55
46
55 Series - Miniature General Purpose Relays 7 -10 A
CONTACT SPECIFICATIONS
Breaking capacity for DC1 load.
1= 2 - 3 CO type.
2= 4 CO type.
A= Load applied to 1 contact
B= Load applied to 2 contacts in series
C= Load applied to 3 contacts in series
D= Load applied to 4 contacts in series
When switching a resistive load (DC1) having voltage and
current values under the curve the expected electrical life is
100·103 cycles.
In case of DC13 loads the connection of a diode in parallel with
the load will permit the same electrical life as for a DC1 load.
Note: the release time of load will be increase.
Electrical life vs AC1 load.
1 = 4 CO relay type (7 A).
2 = 2 - 3 CO relay type (10 A).
124
0
16
8
106
105
107
2
1
F 55
LOAD RATED CURRENT (A)
CYCLES
20 60
100 140 180 220
20
10
6
4
2
1
0.2
0.1
ABCD
1
2
H 55
CONDUCTED DISTURBANCE IMMUNITY BURST (according to EN 61000-4-4) level 4 (4 kV)
SURGE (according to EN 61000-4-5) level 4 (4 kV)
IMMUNITY
INSULATION according to EN 61810-5 insulation rated voltage V 400 (2-3 pole) 250 (4 pole)
rated impulse withstand voltage kV 3.6 (2-3 pole) 2.5 (4 pole)
pollution degree 2
overvoltage category III
TECHNICAL DATA
INSULATION
OTHER DATA
BOUNCE TIME: NO/NC ms 1/4
VIBRATION RESISTANCE (10…55Hz): NO/NC g/g 6/6
POWER LOST TO THE ENVIRONMENT 2 CO 3 CO 4 CO
- without contact current W111
- with rated current W343
RECOMMENDED DISTANCE between RELAYS mounted on P.C.B.s mm
5
DC VOLTAGE (V)
DC BREAKING CURRENT (A)
ACCESSORIES
055.05
Adaptor with top mount flange (for 55.32/33/34)
0
55.05
44.4
37.5
15
3.6
44.4
34.33.5
1.7
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
UNUmin Umax RI at UN
VVVmA
69.006 4.8 6.6 40 150
12 9.012 9.6 13.2 140 86
24 9.024 19.2 26.4 600 40
48 9.048 38.4 52.8 2,400 20
60 9.060 48 66 4,000 15
110 9.110 88 121 12,500 8.8
125 9.125 100 137.5 17,300 7.2
220 9.220 176 242 54,000 4
47
55 Series - Miniature General Purpose Relays 7 -10 A
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
UNUmin Umax R
I at UN(50Hz)
VVVmA
68.006 4.8 6.6 12 200
12 8.012 9.6 13.2 50 97
24 8.024 19.2 26.4 190 53
48 8.048 38.4 52.8 770 25
60 8.060 48 66 1,200 21
110 8.110 88 121 4,000 12.5
120 8.120 96 132 4,700 12
230 8.230 184 253 17,000 6
240 8.240 192 264 19,100 5.3
AC VERSION DATA
DC VERSION DATA
COIL SPECIFICATIONS
Operating range (AC type) vs ambient temperature.
1- Max coil voltage permitted.
2- Min pick-up voltage with coil at ambient temperature.
Operating range (DC type) vs ambient temperature.
1- Max coil voltage permitted.
2- Min pick-up voltage with coil at ambient temperature.
R 55 AC
60
2.0
-20
1.0
0.5
1.5
04020
U
UN
80
2
1
AMBIENT TEMPERATURE (°C)
R 55 DC
60
2.0
-20
1.0
0.5
1.5
04020
U
UN
80
2
1
AMBIENT TEMPERATURE (°C)
55
48
94 Series - Sockets and Accessories for 55 Series Relays
32
25.9
60.9
35.6
35.5
21.5
18.9
17.5 17.5
27
76
Ø 3.2
34.9
Ø 3
27
76
34.9
Ø 3
27
76
34.9
Ø 3
Ø 3.2
Ø 3.2
COIL
41
12
44
8
42
4
COM
NO
NC
11
9
14
5
12
1
A2
14 A1
13
94.02
31
921
811
7
34
624
514
4
32
322
212
1
A2
14 A1
13 COIL
COM
NO
NC
94.03
41
12 COM
NO
NC
31
11 21
10 11
9
44
834
724
614
5
42
432
322
212
1
COIL
A2
14 A1
13
94.04
94.04
Approvals
(according to type):
CU
®
- RATED VALUES: 10 A - 250 V
- DIELECTRIC STRENGTH: 2 kV AC
- PROTECTION CATEGORY: IP 20
- AMBIENT TEMPERATURE: (-40…+70)°C
- SCREW TORQUE: 0.5 Nm
- WIRE STRIP LENGTH: 8 mm
- MAX WIRE SIZE:
- RATED VALUES: 10 A - 250 V
094.06
094.01
6-way jumper link
094.06
10.3
5.1
0.75 272726.25 27 26.25
135
3.3
7
solid wire
stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG
1x10 / 2x14 1x12 / 2x14
Relay type 55.32 55.33 55.32, 55.34
Colour BLUE BLACK BLUE BLACK BLUE BLACK
Clamp terminal socket: panel or 35 mm rail (EN 50022) mount 94.02
94.02.0
94.03
94.03.0
94.04
94.04.0
retaining clip 094.71 supplied with socket packaging code SMA
Metal retaining clip 094.71
Plastic retaining and release clip 094.01
6-way jumper link for 94.02, 94.03 and 94.04 sockets 094.06
094.06.0
094.06
094.06.0
094.06
094.06.0
Identification tag 094.00.4
Modules (see table below) 99.02
Timer modules 86.10, 86.20
Sheet of marker tags for retaining and release clip 094.01 060.72
GOST
55
*Modules in Black
housing are
available on request.
**For DC supply,
apply the positive
to terminal A1.
99.02
99.02 coil indication and EMC suppression modules
(see technical data page 179)
BLUE*
Diode** (+A1, standard polarity) (6...220) V DC 99.02.3.000.00
Diode (+A2, non standard polarity) (6...220) V DC 99.02.2.000.00
LED (6...24) V DC/AC 99.02.0.024.59
LED (28...60) V DC/AC 99.02.0.060.59
LED (110...240) V DC/AC 99.02.0.230.59
LED + Diode** (+A1, standard polarity) (6...24) V DC 99.02.9.024.99
LED + Diode** (+A1, standard polarity) (28...60) V DC 99.02.9.060.99
LED + Diode** (+A1, standard polarity) (110...220) V DC 99.02.9.220.99
LED + Diode (+A2, non standard polarity) (6...24) V DC 99.02.9.024.79
LED + Diode (+A2, non standard polarity) (28...60) V DC 99.02.9.060.79
LED + Diode (+A2, non standard polarity) (110...220) V DC 99.02.9.220.79
LED + Varistor (6...24) V DC/AC 99.02.0.024.98
LED + Varistor (28...60) V DC/AC 99.02.0.060.98
LED + Varistor (110...240) V DC/AC 99.02.0.230.98
RC circuit (6...24) V DC/AC 99.02.0.024.09
RC circuit (28...60) V DC/AC 99.02.0.060.09
RC circuit (110...240) V DC/AC 99.02.0.230.09
Residual current by-pass (62 k/1W) (110...240) V AC 99.02.8.230.07
CUS
®
86.10
86 Series Module Timers (see technical data pages 126/131) BLUE
Mono-function: 12…24 V AC/DC; function AI; (1.5s…60min) 86.10.0.024.0000
Mono-function: 12…24 V AC/DC; function DI; (1.5s…60min) 86.20.0.024.0000
FOR 94.02, 94.03 AND 94.04 SOCKETS:
Approvals
(according to type):
GOST
30
Ø 4.2
24
Ø 3
30
Ø 4.2
24
Ø 3
68.5
==
Ø 4.1
24
30 26
Ø 3
35 14.5
19
23
36.3
70.5
27
35
23
16.519
36.3
70.5
27
35
23
16.519
41
12
NO
NC
COIL
COM
11
9
A2
14 A1
13
44
814
5
42
412
1
94.72
COM
NO
NC
COIL
34
624
514
4
32
322
212
1
31
921
811
7
A2 A1
94.73
44
8
COM
NO
NC
COIL
34
724
614
5
42
432
322
212
1
A2
14 A1
13
41
12 31
11 21
10 11
9
94.74
23
71.3
29.5
26
35 15.5
20.8
40.3
Ø 4.2
94.82
COM
42
4
COIL
NC
NO
41
12
12
1
44
814
5
11
9
A2
14 A1
13
Relay type 55.32 55.33 55.32, 55.34
Colour BLUE BLACK BLUE BLACK BLUE BLACK
Screw terminal socket: panel or 35 mm rail (EN 50022) mount 94.72
94.72.0
94.73
94.73.0
94.74
94.74.0
retaining clip 094.71 supplied with socket packaging code SMA
Retaining clip 094.71
Modules (see table below) 99.01
Relay type 55.32
Colour BLUE BLACK
Screw terminal socket: panel or 35 mm rail (EN 50022) mount 94.82
94.82.0
retaining clip 094.71 supplied with socket packaging code SMA
Retaining clip 094.71
Modules (see table below) 99.01
49
94 Series - Sockets and Accessories for 55 Series Relays
94.74
Approvals
(according to type):
99.01
- RATED VALUES: 10 A - 250 V
- DIELECTRIC STRENGTH:
2 kV AC
- PROTECTION CATEGORY: IP 20
- AMBIENT TEMPERATURE:
(-40…+70)°C
- SCREW TORQUE: 0.5 Nm
- WIRE STRIP LENGTH: 8 mm
- MAX WIRE SIZE:
CUS
®
94.82
Approvals
(according to type):
- RATED VALUES: 10 A - 250 V - MAX WIRE SIZE:
- DIELECTRIC STRENGTH: 2 kV AC
- PROTECTION CATEGORY: IP 20
- AMBIENT TEMPERATURE: (-40…+70)°C
- SCREW TORQUE: 0.5 Nm
- WIRE STRIP LENGTH: 9 mm
CUS
®
solid wire
stranded wire
mm2
1x2.5 / 2x1.5 1x2.5 / 2x1.5
AWG
1x14 / 2x16 1x14 / 2x16
solid wire
stranded wire
mm2
1x2.5 / 2x1.5 1x2.5 / 2x1.5
AWG
1x14 / 2x16 1x14 / 2x16
99.01 coil indication and EMC suppression modules
(see technical data pag. 179) BLUE*
Diode** (+A1, standard polarity) (6...220) V DC 99.01.3.000.00
Diode (+A2, non standard polarity) (6...220) V DC 99.01.2.000.00
LED (6...24) V DC/AC 99.01.0.024.59
LED (28...60) V DC/AC 99.01.0.060.59
LED (110...240) V DC/AC 99.01.0.230.59
LED + Diode** (+A1, standard polarity) (6...24) V DC 99.01.9.024.99
LED + Diode** (+A1, standard polarity) (28...60) V DC 99.01.9.060.99
LED + Diode** (+A1, standard polarity) (110...220) V DC 99.01.9.220.99
LED + Diode (+A2, non standard polarity) (6...24) V DC 99.01.9.024.79
LED + Diode (+A2, non standard polarity) (28...60) V DC 99.01.9.060.79
LED + Diode (+A2, non standard polarity) (110...220) V DC 99.01.9.220.79
LED + Varistor (6...24) V DC/AC 99.01.0.024.98
LED + Varistor (28...60) V DC/AC 99.01.0.060.98
LED + Varistor (110...240) V DC/AC 99.01.0.230.98
RC circuit (6...24) V DC/AC 99.01.0.024.09
RC circuit (28...60) V DC/AC 99.01.0.060.09
RC circuit (110...240) V DC/AC 99.01.0.230.09
Residual current by-pass (62 k/1W) (110...240) V AC 99.01.8.230.07
GOST
GOST
55
*Modules in Black
housing are
available on request.
**For DC supply,
apply the positive
to terminal A1.
Green LED is
standard. Red LED
available on request.
FOR 94.72, 94.73, 94.74 AND 94.82 SOCKETS:
GOST
Approvals
(according to type):
C
E
R
T
I
F
I
C
A
C
I
O
N
D
E
C
O
N
F
O
R
M
I
D
A
D
D
E
L
A
F
A
B
R
I
C
A
C
I
O
N
Relay type 55.32, 55.34
Colour BLUE BLACK
Screwless terminal socket: 35 mm rail (EN 50022) mount 94.54.1 94.54.10
retaining clip 094.91 supplied with socket packaging code SPA
Retaining clip 094.71
Plastic retaining and release clip 094.91
Identification tag
Modules (see table below) 99.80
50
94 Series - Sockets and Accessories for 55 Series Relays
94.84.3
Approvals
(according to type):
99.80
- RATED VALUES: 10 A - 250 V
- DIELECTRIC STRENGTH: 2 kV AC
- PROTECTION CATEGORY: IP 20
- AMBIENT TEMPERATURE: (-40…+70)°C
- SCREW TORQUE: 0.5 Nm
- WIRE STRIP LENGTH: 7 mm
- MAX WIRE SIZE:
solid wire
stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG
1x10 / 2x14 1x12 / 2x14
24.8
35.6
46.81
64.81
86.12
20.819.9
27
76.22
Relay type 55.32 55.32, 55.34
Colour BLUE BLACK BLUE BLACK
Clamp terminal socket: panel or 35 mm rail (EN 50022) mount 94.82.3 94.82.30 94.84.3 94.84.30
retaining clip 094.71 supplied with socket packaging code SMA
Retaining clip 094.71
Plastic retaining and release clip 094.91.3
Identification tag 094.80.2
Modules (see table below) 99.80
99.80 coil indication and EMC suppression modules
(see technical data page 179) BLUE*
Diode** (+A1, standard polarity) (6...220) V DC 99.80.3.000.00
LED (6...24) V DC/AC 99.80.0.024.59
LED (28...60) V DC/AC 99.80.0.060.59
LED (110...240) V DC/AC 99.80.0.230.59
LED + Diode** (+A1, standard polarity) (6...24) V DC 99.80.9.024.99
LED + Diode** (+A1, standard polarity) (28...60) V DC 99.80.9.060.99
LED + Diode** (+A1, standard polarity) (110...220) V DC 99.80.9.220.99
LED + Varistor (6...24) V DC/AC 99.80.0.024.98
LED + Varistor (28...60) V DC/AC 99.80.0.060.98
LED + Varistor (110...240) V DC/AC 99.80.0.230.98
RC circuit (6...24) V DC/AC 99.80.0.024.09
RC circuit (28...60) V DC/AC 99.80.0.060.09
RC circuit (110...240) V DC/AC 99.80.0.230.09
Residual current by-pass (62 k/1W) (110...240) V AC 99.80.8.230.07
44
8
COM
NO
NC
COIL
34
724
614
5
42
432
322
212
1
A2
14 A1
13
41
12 31
11 21
10 11
9
94.84.3
44
8
COM
NO
NC
COIL
14
5
42
412
1
A2
14 A1
13
41
12 11
9
94.82.3
94.54.1
Approvals
(according to type):
- RATED VALUES: 10 A - 250 V
- DIELECTRIC STRENGTH: 2 kV AC
- PROTECTION CATEGORY: IP 20
- AMBIENT TEMPERATURE: (-25…+70)°C
- WIRE STRIP LENGTH: 7 mm
- MAX WIRE SIZE:
solid wire
stranded wire
mm22x(0.2…1.5) 2x(0.2…1.5)
AWG
2x(24…18) 2x(24…18)
42.5
27
33.2
24
6
35 30
30
31
15.45
41
12 COM
NO
NC
31
11 21
10 11
9
44
834
724
614
5
42
432
322
212
1
COIL
A2
14 A1
13
94.54.1
55
*Modules in Black
housing are
available on request.
**For DC supply,
apply the positive
to terminal A1.
Green LED is standard.
Red LED available on
request.
FOR 94.82.3, 94.84.3 AND 94.54.1 SOCKETS:
Approvals
(according to type):
GOST
51
94 Series - Sockets and Accessories for 55 Series Relays
21.5 21.5 11.5
3.7
29.5
29.5
8.5
25.5
21.5
29.5
94.14
Approvals
(according to type):
CUS
®
- RATED VALUES: 10 A - 250 V
- DIELECTRIC STRENGTH: 2 kV AC
- AMBIENT TEMPERATURE: (-40…+70)°C
94.12
29.5
21.5
13
.
2
1.5
5.3
4.1
6.3
7.5
==
94.13
29.5
21.5
6
.
6
1.5
5.3
4.1
6.3
7.5
==
94.14
29.5
21.5
4
.
4
1.5
5.3
4.1
6.3
7.5
==
GOST
29.5
21.5 17
9.5
25.5
29.5
21.5
29.5
21.5
25.8
1
21.8
94.22 94.23 94.24
2
94.22
Approvals
(according to type):
- RATED VALUES: 10 A - 250 V
- DIELECTRIC STRENGTH: 2 kV AC
- AMBIENT TEMPERATURE: (-40…+70)°C
40.5
21.5
17
8.5
40.5
21.5
40.5
21.5
7.5
Ø 3.2
26.5
34 ==
7.5
22.5
94.32 94.33 94.34
3
94.34
Approvals
(according to type):
- RATED VALUES: 10 A - 250 V
- DIELECTRIC STRENGTH: 2 kV AC
- AMBIENT TEMPERATURE: (-40…+70)°C
Relay type 55.32 55.33 55.32, 55.34
Colour BLUE BLACK BLUE BLACK BLUE BLACK
P.C.B. socket 94.12
94.12.0
94.13
94.13.0
94.14
94.14.0
retaining clip 094.51 supplied with socket packaging code SMA
Metal retaining clip 094.51
Relay type 55.32 55.33 55.32, 55.34
Colour BLUE BLACK BLUE BLACK BLUE BLACK
Panel mount solder socket: 1 mm thick panel 94.22
94.22.0
94.23
94.23.0
94.24
94.24.0
retaining clip 094.51 supplied with socket packaging code SMA
Metal retaining clip 094.51
Relay type 55.32 55.33 55.32, 55.34
Colour BLUE BLACK BLUE BLACK BLUE BLACK
Panel mount socket: M3 screw mount - solder connections 94.32
94.32.0
94.33
94.33.0
94.34
94.34.0
retaining clip 094.51 supplied with socket packaging code SMA
Metal retaining clip 094.51
Copper side view
55
C
E
R
T
I
F
I
C
A
C
I
O
N
D
E
C
O
N
F
O
R
M
I
D
A
D
D
E
L
A
F
A
B
R
I
C
A
C
I
O
N
CUS
®
GOST
C
E
R
T
I
F
I
C
A
C
I
O
N
D
E
C
O
N
F
O
R
M
I
D
A
D
D
E
L
A
F
A
B
R
I
C
A
C
I
O
N
CUS
®
GOST
C
E
R
T
I
F
I
C
A
C
I
O
N
D
E
C
O
N
F
O
R
M
I
D
A
D
D
E
L
A
F
A
B
R
I
C
A
C
I
O
N
94 Series - Sockets and Accessories for 55 Series Relays
How to code and identify retaining clip and packaging options for sockets.
Code options according to the last three letters:
PACKAGING CODES
A
SM
AStandard packaging
SM Metal retaining clip
SP Plastic retaining clip
SX No retaining clip
0 494
55
Sheet of marker tags for retaining clip 094.01 (72 tags): 6x12mm
060.72
060.72
ACCESSORIES
52
.