Data Sheet ACD-10 PLUS 600A Clamp-On Multimeter Amprobe's ACD-10 PLUS meter offers thinner jaws over standard clamp meters. Allowing access to tight measurement areas and still accommodating conductors up to 25 mm. It also measures Capacitance and Frequency. Frequency is measured by either jaws or test leads. Very versatile clamp multimeter. No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. AC & DC Voltage to 600V AC Current to 600A Thin Jaws, only 10mm (0.4") thick Resistance to 40MW Continuity Buzzer Capacitance to 3000 uF Frequency measurement In rush current Hold & Maximum reading functions Accommodates conductors up to 26mm (1.02") in diameter Auto ranging Auto power off Rubber over-molded case Overload protected (note: $500 MSLP limit) 600V Amprobe(R) Test Tools www.Amprobe.com Data Sheet ACD-10 PLUS 600A Clamp-On Multimeter General Specifications Display: 3-3/4 digits 4000 counts LCD display Update Rate: 3 per second nominal Polarity: Automatic Operating Temperature: 0 C to 40 C; < 80% RH for temperature up to 31 C decreasing linearly to 50% RH at 40 C Altitude: Operating below 2000m; Indoor use Storage Temperature: -20 C to 60 C, < 80% RH (with battery removed) Temperature Coefficient: nominal 0.15 x (specified accuracy)/C @(0 C ~ 18 C or 28 C ~ 40 C) Low Battery: Below approx. 2.4V Power Supply: 3V coin battery IEC-CR2032 Power Consumption: 2.8 mA typical except that 3.3 mA typical for ACA function APO Timing: Idle for 30 minutes APO Consumption: 5 A typical Dimension: 190 x 63 x 32 mm (7.4 x 2.5 x 1.3 in) Weight: 139 gm approx Jaw opening & Conductor diameter: max 26 mm Special Features: 30ms Max Hold; Data Hold; Relative Zero mode Safety: Meets EN61010-2-032, UL61010B-2-032, IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed. CAT III-600 Volts ac & dc; Pollution degree : 2 EMC: Conforms to EN61326-1. This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. Electrical Specification Accuracy (23 C 5 C & < 75% R.H.) Function Range Accuracy DC Voltage 400.0 mV 4.000, 40.00, 400.0 V 600 V NMRR: CMRR: Input Impedance: Transient protection: ( 0.3% + 4 digits) ( 0.5% + 3 digits) ( 1.0% + 4 digits) >50 dB @ 50/60Hz >120 dB @ DC, 50/60 Hz, Rs=1 k 10 M, 30 pF nominal (1000 M for 400.0 mV range) 6.5 kV (1.2/50 s surge) AC Voltage (50Hz ~ 500Hz) 4.000, 40.00, 400.0 V 600 V CMRR: Maximum Crest Factor: Input Impedance: Transient protection: ACD-10 Plus: Amprobe(R) Test Tools ( 1.5% + 5 digits) ( 2.0% + 5 digits) >60dB @ DC to 60 Hz, Rs=1 k < 1.75 : 1 at full scale & < 3.5 : 1 at half scale limited to fundamental and harmonics, that fall within the meter specified AC bandwidth for non-sinusoidal waveforms 10 M, 30 pF nominal 6.5 kV (1.2/50s surge) Average Sensing www.Amprobe.com Data Sheet ACD-10 PLUS 600A Clamp-On Multimeter Electrical Specification Accuracy (23 C 5 C & < 75% R.H.), cont. Function Range Accuracy AC Current (Clamp-on 50Hz / 60Hz) Range Accuracy 1) 2) 3) 40.00, 400.0, 600 A ( 1.5% + 8 digits) Overload Protections: ACA Clamp-on jaws : 600 A rms continuous ACD-10 Plus: Average Sensing 1) Max Induced error from adjacent current carrying conductor: 0.05 A 2) Specified accuracy is from 1% to 100% of range and for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 2% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaw opening) 3) Add 8 digits to specified accuracy @ reading < 10% of range Resistance 400.0 ( 0.8% + 8 digits) 4.000, 40.00, 400.0 k ( 0.6% + 4 digits) 4.000 M ( 1.0% + 4 digits) 40.00 M ( 2.0% + 4 digits) Open Circuit Voltage : 0.4 VDC typical Transient protection : 6.5 kV (1.2/50s surge) Frequency Function Sensitivity (Sine RMS) Range Accuracy 400.0 mVac 350mV 1 0 Hz ~ 2 kHz ( 0.5%+4 digits) 4.000 Vac 1V 5 Hz ~ 5 kHz ( 0.5%+4 digits) 4.000, 40.00 Vac 32V 5 Hz ~ 100 kHz ( 0.5%+4 digits) 400.0 Vac 90V 5 Hz ~ 10 kHz ( 0.5%+4 digits) 600 Vac 500V 5 Hz ~ 5 kHz ( 0.5%+4 digits) 400.0 Aac 60A 40 Hz ~ 400 Hz ( 0.5%+4 digits) Display counts: 5000 Resolution: 0.001Hz Overload Protection : ACA Clamp-on jaws : AC 600A rms continuous Transient protection : VAC input jacks : 6.5kV (1.2/50s surge) Capacitance Range 1) Accuracy 2) 3) 500.0nF, 5.000F, ( 3.5% + 6 digits) 50.00F, 500.0F, 3000F 1) Additional 50.00nF range accuracy is not specified 2) Accuracies with film capacitor or better 3) Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V Transient protection: 6.5 kV (1.2/50 s surge) Audible Continuity Tester Audible indication: between 10 and 120 . Transient protection: 6.5 kV (1.2/50 s surge) Diode Tester / Open Circuit Voltage Test Current (Typical) < 1.6 VDC @ 0.25 mA Transient protection: 6.5 kV (1.2/50 s surge) Max Hold* (where applicable) Specified accuracy 50 digits for changes > 25 ms in duration www.Amprobe.com ACD-10 PLUS 600A Clamp-On Multimeter Data Sheet Included Accessories Test leads, battery installed, soft carrying pouch, and users manual Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe(R) Test Tools Europe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 (c)2007 Amprobe Test Tools. All rights reserved. 9/2007 3128771 Rev A Amprobe(R) Test Tools www.Amprobe.com