Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices TW Series -- 22mm NEMA Style Pushbuttons Signaling Lights Relays & Sockets Key features: TW NEMA Style Switches with snap-on contacts Corrosion resistant octagonal chrome plated locking bezel Snap-on 10A contact blocks Incandescent or LED illumination Slow make, double break, self cleaning contacts Modular construction for maximum flexibility NEMA 4X and IP65 watertight/oiltight panel Available assembled or as sub-components Large M3.5 screw terminals with captive sems plate UL Listed File No. E68961 CSA Approved File No. LR21451 IDEC has your 22mm switching needs covered. Button styles include flush, extended, mushroom, or square and all bodies are crafted from fracture-resistant nylon. All illuminated units feature two lens styles, one that maximizes light dispersion, the other accommodates direct lens engraving. Timers * * * * * * * * * Self cleaning contact mechanisms allow for a wide current rating, 5mA to 10A, which reduces the need for various contact materials. When looking for a 22mm switch that is durable, easy to use, and versatile, then IDEC's TW series is your solution. File No. DK95-01696 Contactors Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 645 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Conforming to Standards (R) CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TUV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Certificate No. 2030010305027380 File No. LR21451 Specifications Registration No: J9551802 (E-Stops) Registration No: J9551803 (All other switches) Registration No: J9551804 (Pilot Lights) Timers Relays & Sockets Signaling Lights File No. E68961 Operation: -25 to +50C (without freezing), Storage: -40 to +80C (without freezing) Vibration Resistance 5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6 Shock Resistance 1000m/sec2 (100g) conforming to IEC6068-2-7 Electric Shock Protection Class 0 conforming to IEC60536 Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110) IP65 from front of the panel; (IP54 for key switches) IP20 (Type HW-F contact block) Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches) Mechanical Life Momentary pushbuttons: 5,000,000 (900 operations per hour) All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 for switches not using a transformer, 2 for switches using a transformer Rated Operational Characteristics AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or slow make NO, self-cleaning Recommended Terminal Torque 0.8 N m (7.1 in lb.) External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50m or less Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB) Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Lamp Ratings Incandescent: 1 W LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max Horsepower Rating 1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor) Maximum Inrush Current 40 A (40 ms) Contact Material Silver Contact Ratings Operating Temperature Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Characteristics Contactors Terminal Blocks EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals Operational Voltage Contact Block Type HW-C/HW-F Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600) DC-13 (P600) Circuit Breakers Contact Ratings by Utilization Category AC50/60Hz Operational Current 646 DC 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads and solid state loads 10A -- 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A -- 7A 5A 3A 1A DC-12 Control of resistive loads and solid state loads 8A 5A -- 2.2A 1.1A -- DC-13 Control of electromagnets 5A 2A -- 1.1A 0.6A -- www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) Signaling Lights A B ( ) W 1 10 ( ) - Relays & Sockets Assembled Pushbuttons B Function Button Color B: Momentary O: Maintained K: Key On/Off Lock B: Black R: Red G: Green S: Blue W: White Y: Yellow Terminal Style Bezel Shape Timers Blank: Standard N: Fingersafe (IP20) Blank: Octagonal F: Full Shroud G: Mushroom Shroud Q: Square Contact Arrangement 10: 1NO 20: 2NO 11: 1NO-1NC 01: 1NC 02: 2NC 22: 2NO-2NC 1: 2: 3: 4: Contactors Button Shape Flush Extended Mushroom Head O 29mm Mushroom Head O 40mm Series Designation Terminal Blocks W: TW Series To be used for interpreting part numbers only, not for part number development. Circuit Breakers 800-262-IDEC (4332) * USA & Canada 647 Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) continued Non-Illuminated Pushbuttons Style Contactors Terminal Blocks Circuit Breakers j Button Color Codes Contacts 1NO 1NC 1NO-1NC 2NO 2NC Flush Momentary Action ABW110-j ABW101-j ABW111-j ABW120-j ABW102-j Maintained Action Color Code AOW110-j AOW101-j AOW111-j AOW120-j AOW102-j Black B Green G Red R Extended 1NO 1NC 1NO-1NC 2NO 2NC ABW210-j ABW201-j ABW211-j ABW220-j ABW202-j AOW210-j AOW201-j AOW211-j AOW220-j AOW202-j Recessed 1NO 1NC 1NO-1NC 2NO 2NC ABFW110-j ABFW101-j ABFW111-j ABFW120-j ABFW102-j AOFW110-j AOFW101-j AOFW111-j AOFW120-j AOFW102-j Extended with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFW210-j ABFW201-j ABFW211-j ABFW220-j ABFW202-j AOFW210-j AOFW201-j AOFW211-j AOFW220-j AOFW202-j O 29mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW310-j ABW301-j ABW311-j ABW320-j ABW302-j AOW310-j AOW301-j AOW311-j AOW320-j AOW302-j O 40mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW410-j ABW401-j ABW411-j ABW420-j ABW402-j AOW410-j AOW401-j AOW411-j AOW420-j AOW402-j O 40mm Mushroom Head with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGW410-j ABGW401-j ABGW411-j ABGW420-j ABGW402-j AOGW410-j AOGW401-j AOGW411-j AOGW420-j AOGW402-j Square Flush 1NO 1NC 1NO-1NC 2NO 2NC ABQW110-j ABQW101-j ABQW111-j ABQW120-j ABQW102-j AOQW110-j AOQW101-j AOQW111-j AOQW120-j AOQW102-j Square Extended 1NO 1NC 1NO-1NC 2NO 2NC ABQW210-j ABQW201-j ABQW211-j ABQW220-j ABQW202-j AOQW210-j AOQW201-j AOQW211-j AOQW220-j AOQW202-j Keylock Push On/ Off 1NO 1NC 1NO-1NC 2NO 2NC AKW210 AKW201 AKW211 AKW220 AKW202 - Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - TW Series 1. 2. 3. 4. 5. In place of j, specify the Button Color Code from table. For sub-assembled part numbers, see next page. For accessories, see page 677. For dimensions, see page 679. Keyed switches are supplied with two keys. All units are keyed alike. 648 www.IDEC.com Blue S Yellow Y White W Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Non-Illuminated Pushbuttons (Sub-Assembled) Contact Blocks + Style + Button Buttons Part Number Momentary Part Number Round Flush Round Flush/Extended ABW1B-j ABW-100 ABW2B-j O 40mm, O 29mm Mushroom Head 1NC HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Standard Exposed Screw Fingersafe (IP20), CE marked AOFW-200 O 29mm Mushroom 1NO Dummy Block ABW3B-j AOW-300 O 40mm Mushroom O 40mm Mushroom Head with Full Shroud ABW4B-j AOGW-400 j Button Color Codes Square Flush ABQW1B-j Square Flush/Extended ABQW-100 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Contactors ABGW-400 TW-DB Timers ABW-300 Relays & Sockets Round Extended Part Number Style AOW-100 Round with Full Shroud/ Recessed ABFW-200 Complete Part Contact Blocks Style Maintained = Signaling Lights Operators Operator AOQW-100 Keylock Push On/Off Code Black B Green G Red R Blue S Yellow Y White W Terminal Blocks Square Extended Color ABQW2B-j -- AKW-200 In place of j specify the button color code from table Circuit Breakers 800-262-IDEC (4332) * USA & Canada 649 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Signaling Lights Stop Switches (Assembled) Relays & Sockets Assembled Stop Switches A V (L) W 4 (B) (99) 11 (D) Function Lamp Voltage (full voltage illuminated units only) V: Pushlock Turn Reset Y: Push-Pull X: Pushlock Key Reset 6V: 12V: 24V: 120V: 240V: Timers Illumination Blank: None L: Illuminated W: TW Series A: Amber R: Red G: Green S: Blue B: Black Button/Lens Size Contact Terminal Style 3: 29mm Mushroom 4: 40mm Mushroom Blank: Standard N: Fingersafe (IP20) Lens Type Lamp Type Contactors (illuminated units only) Terminal Blocks 6V AC/DC 12V AC/DC 24V AC/DC 120V AC (LED only) 240V AC (LED only) Button/Lens Color Series Designation Circuit Breakers (N) - R - (24V) W: White Y: Yellow (illuminated units only) Blank: Standard (ribbed) B: Engravable (smooth with insert) Blank: Incandescent D: LED Illuminated Circuit Contact Arrangement (illuminated unit only) 99: 126: 246: 486: 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer To be used for interpreting part numbers only, not for part number development. 650 www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Stop Switches (Assembled), continued Non-Illuminated Stop Switches j Button Color Codes Style Contacts Color Code AVW410-R* AVW401-R* AVW411-R* AVW420-R* AVW402-R* Black B Green G Red R 1NO 1NC 1NO-1NC 2NO 2NC O 40mm Pushlock Turn Reset* O 40mm Push-Pull AVW310-R* AVW301-R* AVW311-R* AVW320-R* AVW302-R* 1NO 1NC 1NO-1NC 2NO 2NC AYW410-j AYW401-j AYW411-j AYW420-j AYW402-j 1NO 1NC 1NO-1NC 2NO 2NC O 40mm Pushlock Key Reset * AXW410AXW401AXW411AXW420AXW402- R* R* R* R* R* Part Number Full Voltage 1NO-1NC 2NO 2NC AVLW49911n-R*-l AVLW49920n-R*-l AVLW49902n-R*-l Transformer 1NO-1NC 2NO 2NC AVLW3m11n-R* AVLW3m20n-R* AVLW3m02n-R* Full Voltage 1NO-1NC 2NO 2NC AVLW39911n-R*-l AVLW39920n-R*-l AVLW39902n-R*-l Transformer 1NO-1NC 2NO 2NC AYLW4 m 11n-k AYLW4 m 20n-k AYLW4 m 02n-k Full Voltage 1NO-1NC 2NO 2NC AYLW49911n-k-l AYLW49920n-k-l AYLW49902n-k-l O 40mm Push-Pull Amber A Green G Red R Blue S White W Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V (LED only) 240V AC 240V (LED only) m Transformer Voltage Codes Voltage Code 120VAC 240VAC 480VAC 126 246 486 Transformers step down to 6V. n Lamp Type Codes Lamp Code Incandescent Blank LED D Terminal Blocks AVLW4 m 11n-R* AVLW4 m 20n-R* AVLW4 m 02n-R* O 29mm Pushlock Turn Reset Code Contactors Transformer 1NO-1NC 2NO 2NC O 40mm Pushlock Turn Reset Type Color Timers Contacts Y l Full Voltage Codes Illuminated Stop Switches Type Yellow k LED/Lens Color Codes *Available in Red only. In place of j, specify the Button Color Code from table. For sub-assembled part numbers, see next page. For accessories, see page 677. For dimensions, see page 679. Style S W Relays & Sockets 1NO 1NC 1NO-1NC 2NO 2NC Blue White Signaling Lights O 29mm Pushlock Turn Reset* 1. 2. 3. 4. 5. Part Number 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. *Available in red only. 2. In place of k, specify the Lens Color Code (see table above). 3. In place of l, specify the Full Voltage Code (lamp voltage) (see table above). 4. In place of m, specify the Transformer Voltage Code (see table above). 5. In place of n, specify the Lamp Type Code from table above. 6. For sub-assembly part numbers, see next page. 7. For accessories, see page 677. 8. For dimensions, see page 679. 651 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Stop Switches (Sub-Assembled) Transformer/ Adaptor* + Contacts + Lamp Holder + Operator Lamp + Button or Lens = Operators Style Buttons Lamps Part Number Style Non-Illuminated Illuminated O 40mm Pushlock Turn Reset Part Number Style LED AVW4B-R* AVW-300 AVLW3-0600 Incandescent O 29mm Pushlock Turn Reset O 40mm Push-Pull AVW3B-R* AYW-400 Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. AYLW4-0600 O 40mm Push-Pull Timers Complete Part *Not applicable for full voltage units O 29/O 40mm Pushlock Turn Reset Relays & Sockets + O 40mm Pushlock Key Reset j Button Color Codes AYW4B-j AXW-300 -- O 40mm Pushlock Key Reset Contactors AXW4B-R* Circuit Breakers Terminal Blocks 1. *Available in Red only 2. In place of j, specify the button color code from table. 652 www.IDEC.com Color Code Black B Green G Red R Blue S White W Yellow Y k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Stop Switches (Sub-Assembled) continued Lenses Transformers/Full Voltage Modules Style Style Part Number Standard Engravable Description Full Size Transformer Standard O 29mm Head Pushlock Turn Reset AVLW3LU-R* AVLW3BLU-R* Fingersafe Half Size Transformer AVLW4LU-R* AVLW4BLU-R* O 40mm Head Push Pull AYLW4BLU-k Full voltage model (use with even number of contacts) 1. In place of k, specify the lens color code from table on previous page. 2. *Available only in red 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Full voltage model (use with odd number of contacts) Lamp Circuit Components Style Application TW-T246B 480V AC TW-T486B 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B 120V AC TW-T126SB 240V AC TW-T246SB Standard TW-DA1B Fingersafe TW-DA1FB Standard HW-DA1B Fingersafe HW-DA1FB Part Number Timers Short Lamp Holder Used with a Half-size Transformer and one contact block TW-T126B 240V AC Relays & Sockets AYLW4LU-k 120V AC Signaling Lights O 40mm Head Pushlock Turn Reset Part Number TW-LH1 All Transformers step down to 6V (use 6V lamp). TW-LH2 Used with TW-LH2 holder when using four contact blocks HW-LH3 Contact Blocks Style Standard Exposed Screw Lead Holder Part Number 1NO 1NC HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Terminal Blocks Fingersafe (IP20), CE marked Contactors Long Lamp Holder Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks Dummy Block TW-DB Circuit Breakers 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function 800-262-IDEC (4332) * USA & Canada 653 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Relays & Sockets Signaling Lights Pilot Lights (Assembled) Assembled Pilot Lights A P (Q) W 1 (B) (99) (D) - R - (24V) Function Lamp Voltage (Full Voltage Units Only) Circuit Breakers Terminal Blocks Contactors Timers P: Pilot Light Blank: Octagonal (round lenses) Q: Square 6V: 12V: 24V: 120V: 240V: Series Designation Lens Color Code W: TW Series 1: Flat 2: Dome A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lens Type Lamp Type Blank: Standard (ribbed) B: Engravable (smooth with insert included) Blank: Incandescent D: LED Bezel Shape Lens Shape Illumination Circuit 99: 126: 246: 486: Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V. 654 www.IDEC.com 6V AC/DC 12V AC/DC 24V AC/DC 120V AC (LED only) 240V AC (LED only) Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Pilot Lights (Assembled) continued Assembled Pilot Lights k Lens Color Codes Style Type Voltage Part Number Color Code Transformer 120VAC 240VAC 480VAC APW1126m-k APW1246m-k APW1486m-k Amber A Green G Red R -- APW199m-k-l Round Flat Full Voltage 120VAC 240VAC 480VAC APW2126m-k APW2246m-k APW2486m-k Full Voltage -- APW299m-k-l Transformer 120VAC 240VAC 480VAC APQW1B126m-k APQW1B246m-k APQW1B486m-k Dome Full Voltage -- APQW1B99m-k-l 1. In place of k, specify the Lens Color Code from table below. 2. In place of l, specify the Full Voltage Code from table below. 3. In place of m, specify the Lamp Type Code from table below. 4. For accessories, see page 677. 5. For dimensions, see page 679. 6. For sub-assembly part numbers, see next page. 7. Yellow pilot light comes with white LED. Yellow Y l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V (LED only) 240V AC 240V (LED only) Relays & Sockets Square Flat S W Signaling Lights Transformer Blue White m Lamp Type Codes Lamp Code Incandescent Blank LED D Timers Contactors Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 655 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Pilot Lights (Sub-Assembled) Transformer + Operator + Lamp Lens Operators Style Lamps Part Number APW-199 Incandescent Square UPQW-199 Part Number Color Code 6V AC/DC LSTD-6k Amber A 12V AC/DC LSTD-1k Green G 24V AC/DC LSTD-2k Red R 120V AC LSTD-H2k Blue S 240V AC LSTD-M4k White W 6V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 Transformers Style Style Part Number Standard Description Standard Engravable Dome Contactors APW2LU-k Fingersafe -- All Transformers step down to 6V (use 6V lamp). Round Flat APW1LU-k APW1BLU-k -- APQW1BLU-k Square Flat 1. In place of k, specify the Lens Color Code from table. 2. Standard lenses have a ribbed lens to enhance light dispersion. Marking lenses are smooth and include an engravable insert. 656 If clear lens is desired, use white marking lens and remove engraving insert 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. 3. Yellow LED not available. Use white LED. Same operator is used for full voltage as for transformer completed units. Timers Voltage Lenses Terminal Blocks Complete Part k LED/Lens Color Codes Style LED Circuit Breakers = * Transformer not required for full voltage units. Round Dome/Flat Relays & Sockets + www.IDEC.com Part Number 120V AC TW-T126B 240V AC TW-T246B 480V AC TW-T486B 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Pushbuttons (Assembled) Signaling Lights A L (F) W 2 (B) 99 11 Function (N) - R - (24V) Lamp Voltage (Full Voltage Units Only) L:Momentary Action OL:Maintained Action Blank: Octagonal (round lenses) F: Full Shroud (round lenses) Q: Square 6V AC/DC 12V AC/DC 24V AC/DC 120V AC (LED only) 240V AC (LED only) Timers 6V: 12V: 24V: 120V: 240V: Bezel Shape Lens Code W: TW series Lens Shape/Size 2: Standard Extended (round or square) 3: 29mm Mushroom 4: 40mm Mushroom Contactors A: Amber G: Green R: Red S: Blue W: White Y: Yellow Series Designation Contact Terminal Style Blank: Standard N: Fingersafe Lens Type Blank: Standard (ribbed) B: Engravable (smooth with insert) Lamp Type Terminal Blocks Blank: Incandescent Lamp D: LED Lamp Illumination Circuit 99: 126: 246: 486: (D) Relays & Sockets Assembled Illuminated Pushbuttons Contact Arrangement Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer 10: 1NO 20: 2NO 11: 1NO-1NC 01: 1NC 02: 2NC 22: 2NO-2NC Circuit Breakers 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Transformers step down to 6V. 800-262-IDEC (4332) * USA & Canada 657 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Illuminated Pushbuttons (Assembled) Illuminated Pushbuttons Style Signaling Lights Extended Lens Relays & Sockets Extended Lens with Full Shroud Contacts Transformer Timers Contactors Terminal Blocks Square Extended ALW2 m 11n-k ALW2 m 20n-k ALW2 m 02n-k Maintained AOLW2 m 11n-k AOLW2 m 20n-k AOLW2 m 02n-k Full Voltage ALW29911n-k-l ALW29920n-k-l ALW29902n-k-l AOLW29911n-k-l AOLW29920n-k-l AOLW29902n-k-l Transformer 1NO-1NC 2NO 2NC ALFW2 m 11n-k ALFW2 m 20n-k ALFW2 m 02n-k AOLFW2 m 11n-k AOLFW2 m 20n-k AOLFW2 m 02n-k Transformer Full Voltage o40mm Mushroom Lens 1NO-1NC 2NO 2NC Momentary 1NO-1NC 2NO 2NC Full Voltage o29mm Mushroom Lens Circuit Breakers k LED/Lens Color Codes Part Number Transformer 1NO-1NC 2NO 2NC 1NO-1NC 2NO 2NC ALFW29911n-k-l ALFW29920n-k-l ALFW29902n-k-l ALW3 m 11n-k ALW3 m 20n-k ALW3 m 02n-k AOLFW29911n-k-l AOLFW29920n-k-l AOLFW29902n-k-l AOLW3 m11n-k AOLW3 m20n-k AOLW3 m 02n-k 1NO-1NC 2NO 2NC ALW39911n-k-l ALW39920n-k-l ALW39902n-k-l AOLW39911n-k-l AOLW39920n-k-l AOLW39902n-k-l 1NO-1NC 2NO 2NC ALW4 m 11n-k ALW4 m 20n-k ALW4 m 02n-k AOLW4 m11n-k AOLW4 m20n-k AOLW4 m 02n-k Full Voltage 1NO-1NC 2NO 2NC ALW49911n-k-l ALW49920n-k-l ALW49902n-k-l AOLW49911n-k-l AOLW49920n-k-l AOLW49902n-k-l Transformer 1NO-1NC 2NO 2NC ALQW2B m11n-k ALQW2B m20n-k ALQW2B m02n-k AOLQW2B m11n-k AOLQW2B m20n-k AOLQW2B m02n-k Full Voltage 1NO-1NC 2NO 2NC ALQW2B9911n-k-l ALQW2B9920n-k-l ALQW2B9902n-k-l AOLQW2B9911n-k-l AOLQW2B9920n-k-l AOLQW2B9902n-k-l 1. In place of k, specify the Lens Color Code (see table). Mushroom lenses not available in yellow. 2. In place of l, specify the Full Voltage Code (lamp voltage) (see table). 3. In place of m, specify the Transformer Voltage Code (see table). 4. In place of n, specify the Lamp Type Code from table. 5. For sub-assembly part numbers, see next page. 6. For accessories, see page 677. 7. For dimensions, see page 679. 8. Light is independent of switch position. 9. Yellow pushbutton comes with white LED. 658 www.IDEC.com Color Code Amber A Green G Red R Blue S White W Yellow Y 1. Mushroom lenses not available in yellow. 2. Yellow pushbutton comes with white LED. l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V (LED only) 240V AC 240V (LED only) m Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 Transformers step down to 6V (use 6V lamp). n Lamp Type Codes Lamp Code Incandescent Blank LED D Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Pushbuttons (Sub-Assembled) Transformer/ Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Lens = Complete Part Operators Signaling Lights *Not applicable for full voltage units Lamps Style Style Part Number Momentary Maintained LED ALW-0600 Extended ALFW-0600 o29mm/o40mm Mushroom AOLFW-0600 ALW3-0600 AOLW3-0600 Incandescent Part Number LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 Relays & Sockets Extended with Full Shroud AOLW-0600 Voltage 6V AC/DC 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Lamp Circuit Components Style AOLQW-2B0600 Application Short Lamp Holder Lenses Style Used with a Half-size Transformer and one contact block TW-LH1 Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks TW-LH2 Used with TW-LH2 holder when using four contact blocks HW-LH3 Part Number Standard Engravable Round Extended ALW2LU-k ALW2BLU-k o 29mm Mushroom Head* ALW3LU-k ALW3BLU-k Contactors Long Lamp Holder Lead Holder ALW4LU-k ALW4BLU-k Terminal Blocks o 40mm Mushroom Head* Part Number Timers ALQW-2B0600 Square/Extended k LED/Lens Color Codes Square Extended -- ALQW2BLU-k Code Color Code Amber A Blue S Green G White W Red R Yellow Y Circuit Breakers 1. In place of k, specify the lens color code from table on the bottom right. 2. *Mushroom lens not available in yellow. 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Color Yellow LED not available. Use white LED. 800-262-IDEC (4332) * USA & Canada 659 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Illuminated Pushbuttons (Sub-Assembled) continued Transformers/Full Voltage Modules Contact Blocks Style Standard Exposed Screw Fingersafe (IP20), CE marked Style Part Number 1NO 1NC HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Description Full Size Transformer Standard Fingersafe Part Number 120V AC TW-T126B 240V AC TW-T246B 480V AC TW-T486B 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Half Size Transformer 120V AC TW-T126SB 240V AC TW-T246SB Standard TW-DA1B Fingersafe TW-DA1FB Standard HW-DA1B Fingersafe HW-DA1FB Dummy Block Relays & Sockets TW-DB Full voltage model (use with even number of contacts) 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Timers Full voltage model (use with odd number of contacts) Circuit Breakers Terminal Blocks Contactors All Transformers step down to 6V (use 6V lamp). 660 www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) Signaling Lights Relays & Sockets Assembled Selector Switches A S W 3 (1) (L) 20 (N) - 304 Function Circuit Number S: Selector Switch (Standard circuits shown on following pages and 669.) Series Designation Blank: standard N: Fingersafe (IP20) Number of Positions 2: 3: 4: 5: 2-Position 3-Position 4-Position 5-Position Contact Arrangement Code Blank: Maintained 1: Spring return from Right (2 or 3 position) 2: Spring return from Left (2 or 3 position) 3: 2-Way spring return from Left and Right (3 position only) 1NO 01: 2NO 02: 4NO 04: 1NO-1NC 22: 1NC 2NC 4NC 2NO-2NC Contactors 10: 20: 40: 11: Spring Return Action Operator Style Code Blank: Knob Operator L: Lever Operator K: Key Operator Terminal Blocks 1. 2. 3. 4. Timers Contacts Terminal Style W: TW Series Use only when interpreting part numbers. Do not use for developing part numbers. Custom contact configurations available. Custom key removable codes available. Portions of part number inside ( ) are optional. Circuit Breakers 800-262-IDEC (4332) * USA & Canada 661 Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) continued 2-Position Selector Switches Style Part Number Operator Position Spring Return from Left Mounting Spring Return from Right Contact Maintained 1NO 1 2 O O X O Knob Lever Key ASW210 ASW2L10 ASW2K10 ASW2110 ASW21L10 ASW21K10 ASW2210 ASW22L10 ASW22K10 1NC 1 2 X O O O Knob Lever Key ASW201-116 ASW2L01-116 ASW2K01-116 ASW2101-116 ASW21L01-116 ASW21K01-116 ASW2201-116 ASW22L01-116 ASW22K01-116 1NO 1NC 1 2 X O O X Knob Lever Key ASW211 ASW2L11 ASW2K11 ASW2111 ASW21L11 ASW21K11 ASW2211 ASW22L11 ASW22K11 2NO 1 2 O O X X Knob Lever Key ASW220 ASW2L20 ASW2K20 ASW2120 ASW21L20 ASW21K20 ASW2220 ASW22L20 ASW22K20 2NC 1 2 X X O O Knob Lever Key ASW202-104 ASW2L02-104 ASW2K02-104 ASW2102-104 ASW21L02-104 ASW21K02-104 ASW2202-104 ASW22L02-104 ASW22K02-104 2NO 2NC 1 2 3 4 O X O X X O X O Knob Lever Key ASW222 ASW2L22 ASW2K22 ASW2122 ASW21L22 ASW21K22 ASW2222 ASW22L22 ASW22K22 2NO 2NC 1 2 3 4 O O X X X X O O Knob Lever Key ASW222-111 ASW2L22-111 ASW2K22-111 ASW2122-111 ASW21L22-111 ASW21K22-111 ASW2222-111 ASW22L22-111 ASW22K22-111 L R L R L R L Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - TW Series 662 www.IDEC.com R Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) continued 3-Position Selector Switches Style Part Number Spring Return from Right Spring Return from Left Spring Return Two-Way Mounting Maintained Contact Operator Position 2NO 1 2 X O O O O X Knob Lever Key ASW320 ASW3L20 ASW3K20 ASW3120 ASW31L20 ASW31K20 ASW3220 ASW32L20 ASW32K20 ASW3320 ASW33L20 ASW33K20 2NC 1 2 O X X X X O Knob Lever Key ASW302 ASW3L02 ASW3K02 ASW3102 ASW31L02 ASW31K02 ASW3202 ASW32L02 ASW32K02 ASW3302 ASW33L02 ASW33K02 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Knob Lever Key ASW322 ASW3L22 ASW3K22 ASW3122 ASW31L22 ASW31K22 ASW3222 ASW32L22 ASW32K22 ASW3322 ASW33L22 ASW33K22 2NO 2NC 1 2 3 4 X X O O O X X O X O O X Knob Lever Key ASW322-309 ASW3L22-309 ASW3K22-309 ASW3122-309 ASW31L22-309 ASW31K22-309 ASW3222-309 ASW32L22-309 ASW32K22-309 ASW3322-309 ASW33L22-309 ASW33K22-309 2NO 2NC 1 2 3 4 O O O O X O X O O X O X Knob Lever Key ASW322-310 ASW3L22-310 ASW3K22-310 ASW3122-310 ASW31L22-310 ASW31K22-310 ASW3222-310 ASW32L22-310 ASW32K22-310 ASW3322-310 ASW33L22-310 ASW33K22-310 4NO 1 2 3 4 X O X O O O O O O X O X Knob Lever Key ASW340 ASW3L40 ASW3K40 ASW3140 ASW31L40 ASW31K40 ASW3240 ASW32L40 ASW32K40 ASW3340 ASW33L40 ASW33K40 4NC 1 2 3 4 O X O X X X X X X O X O Knob Lever Key ASW304 ASW3L04 ASW3K04 ASW3104 ASW31L04 ASW31K04 ASW3204 ASW32L04 ASW32K04 ASW3304 ASW33L04 ASW33K04 L C R L C L R C C L R L R C R Signaling Lights Relays & Sockets Timers 4-Position Selector Switch 5-Position Selector Switch X O O O 3 Part Number 4 1 2 3 1 2NO 2NC 1 2 3 4 X O O O 4 O X O O O O X O O O O X Knob Lever ASW422-411 ASW4L22-411 Maintained Operator Position Mounting 1 2 3 4 2 Style Contact Operator Position Mounting 2NO 2NC Maintained 2 3 O X O O O O O O Part Number 4 5 O O X O O O O X 1 Knob Lever 2 3 4 5 ASW522-501 ASW5L22-501 Terminal Blocks Contact Style 1 Contactors 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Every key selector switch uses an identical key. The key is removable in any maintained position. 4. Custom contact configurations are available, see page 669. Circuit Breakers 800-262-IDEC (4332) * USA & Canada 663 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + Operator + Color Insert* Operators = Complete Part Handles and Inserts Style Positions ASW200 ASW2100 Spring return from left ASW2200 Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 ASW300-1 ASW300-2 ASW300-3 Spring return from right, Cam 1 Spring return from right, Cam 2 ASW3100-1 ASW3100-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASW3200-1 ASW3200-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASW3300-1 ASW3300-2 4 Maintained, Standard Cam Maintained, Cam 1 ASW400 ASW400-1 5 Maintained, Standard cam Maintained, Cam 1 ASW500 ASW500-1 Maintained ASW2K00 Spring return from right ASW21K00 Spring return from left ASW22K00 Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 ASW3K00-1 ASW3K00-2 ASW3K00-3 Spring return from right, Cam 1 Spring return from right, Cam 2 ASW31K00-1 ASW31K00-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASW32K00-1 ASW32K00-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASW33K00-1 ASW33K00-2 Relays & Sockets Timers 2 Contactors 3 1. 2. 3. 4. Part Number Spring return from right 3 Key Description Maintained Knob/Lever Terminal Blocks Knob or Lever* 1. *Not needed with key type switches. 2. Knob type shown. 2 Circuit Breakers + Style Knob ASWHHY-j Lever ASWHHL-j Color Insert TW-HC1-j Contact Blocks Style Standard Exposed Screw Fingersafe (IP20), CE marked Two keys are supplied with every key switch, all are keyed alike, and removable from any maintained position. Locking rings are included with all operators. Order knobs, levers, and color inserts separately. Different cams produce different contact actions. For details, see page 669. Key switch operator supplied with black sleeve. j Handle/Insert Color Codes Color Code Black* B Blue S Green G Red R Yellow Y White W AKW2B-B 1NO 1NC HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) TW-DB 1. Push rod color code: Green = NO contact block Red = NC contact block. 2. Dummy blocks (no contacts) are used with an odd number of contact blocks. *Color inserts not available in black. Knob and lever not available in white. 664 Part Number Dummy Block Replacement Parts Key Switch Black Sleeve Part Number www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Selector Switches (Assembled) Signaling Lights Assembled Illuminated Selector Switches A SL W 2 (2) 99 11 (D) (N) - (103) - R - (24V) Lamp Voltage (Full Voltage Units Only) SL:Illuminated Selector Switch 6V: 12V: 24V: 120V: 240V: Series Designation W: TW series Number of Positions 6V AC/DC 12V AC/DC 24V AC/DC 120V AC (LED only) 240V AC (LED only) Lens Color Code 2: 2-Position 3: 3-Position Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: Two-Way spring return from Left and Right Timers A: Amber G: Green R: Red S: Blue W: White Y: Yellow Spring Return Action Contact Circuit Number Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer Contactors Standard circuits are listed on the following pages and 669. Illumination Circuit 99: 126: 246: 486: Relays & Sockets Function Contact Terminal Style Blank: Standard N: Fingersafe Terminal Blocks Lamp Type Blank: Incandescent Lamp D: LED Lamp Contact Arrangement 01: 1NC 02: 2NC 04: 4NC 22: 2NO-2NC Circuit Breakers 10: 1NO 20: 2NO 40: 4NO 11: 1NO-1NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V (use 6V lamp). 800-262-IDEC (4332) * USA & Canada 665 Switches & Pilot Devices Circuit Breakers Illuminated Selector Switches(Assembled) continued Illuminated 2-Position Selector Switches j Transformer Voltage Codes Style Part Number Spring Return from Right Spring Return from Left Mounting Maintained Contact Operator Position 1NO 1NC 1 2 O X X O Transformer Full Voltage ASLW2 j 11m-k ASLW29911m-k-l ASLW21 j 11m-k ASLW219911m-k-l ASLW22 j 11m-k ASLW229911m-k-l 2NO 1 2 O O X X Transformer Full Voltage ASLW2 j 20m-k ASLW29920m-k-l ASLW21 j 20m-k ASLW219920m-k-l ASLW22 j 20m-k ASLW229920m-k-l 2NC 1 2 X X O O Transformer Full Voltage ASLW2 j 02m-104-k ASLW29902m-104-k-l ASLW21 j 02m-104-k ASLW219902m-104-k-l ASLW22 j 02m-104-k ASLW229902m-104-k-l 2NO 2NC 1 2 3 4 O X O X X O X O Transformer Full Voltage ASLW2 j 22m-k ASLW29922m-k-l ASLW21 j 22m-k ASLW219922m-k-l ASLW22 j 22m-k ASLW229922m-k-l L R Lamp Circuit Type L L R L R R Code 120VAC 126 240VAC 246 480VAC 486 Transformers step down to 6V (use 6V lamp). k LED/Lens Color Codes Illuminated 3-Position Selector Switches, Maintained and Spring Return from Right Style Voltage Color Code Amber A Green G Red R Blue S White W Yellow Y Part Number Maintained Spring Return From Right Spring Return from Left Spring Return Two-Way Mounting Operator Position Contact Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - TW Series 2NO 1 2 X O O O O X Transformer Full Voltage ASLW3 j 20m-k ASLW39920m-k-l ASLW31 j 20m-k ASLW319920m-k-l ASLW32 j 20m-k ASLW329920m-k-l ASLW33 j 20m-k ASLW339920m-k-l 2NC 1 2 O X X X X O Transformer Full Voltage ASLW3 j 02m-k ASLW39902m-k-l ASLW31 j 02m-k ASLW319902m-k-l ASLW32 j 02m-k ASLW329902m-k-l ASLW33 j 02m-k ASLW339902m-k-l 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Transformer Full Voltage ASLW3 j 22m-k ASLW39922m-k-l ASLW31 j 22m-k ASLW319922m-k-l ASLW32 j 22m-k ASLW329922m-k-l ASLW33 j 22m-k ASLW339922m-k-l 2NO 2NC 1 2 3 4 X X O O O X X O X O O X Transformer Full Voltage ASLW3 j 22m-309-k ASLW39922m-309-k-l ASLW31 j 22m-309-k ASLW319922m-309-k-l ASLW32 j 22m-309-k ASLW329922m-309-k-l ASLW33 j 22m-309-k ASLW339922m-309-k-l 2NO 2NC 1 2 3 4 O O O O X O X O O X O X Transformer Full Voltage ASLW3 j 22m-310-k ASLW39922m-310-k-l ASLW31 j 22m-310-k ASLW319922m-310-k-l ASLW32 j 22m-310- k ASLW329922m-310- k -l ASLW33 j 22m-310-k ASLW339922m-310-k-l 4NO 1 2 3 4 X O X O O O O O O X O X Transformer Full Voltage ASLW3 j 40m-k ASLW39940m-k-l ASLW31 j 40m-k ASLW319940m-k-l ASLW32 j 40m-k ASLW329940m-k-l ASLW33 j 40m-k ASLW339940m-k-l 4NC 1 2 3 4 O X O X X X X X X O X O Transformer Full Voltage ASLW3 j 04m-k ASLW39904m-k-l ASLW31 j 04m-k ASLW319904m-k-l ASLW32 j 04m-k ASLW329904m-k-l ASLW33 j 04m-k ASLW339904m-k-l 1. 2. 3. 4. 5. 6. 7. L C R Lamp Circuit Type In place of j, specify the Transformer Voltage Code. In place of k, specify the Lens/LED Color Code. In place of l, specify the Full Voltage Code. In place of m specify Lamp Type Code For custom contact configurations, see page 669. Light is independent of switch position. Yellow selector switch comes with white LED. 666 L C L R C L R l Full Voltage Codes Voltage C L R C m Lamp Type Codes Code Lamp Code 6V AC/DC 6V Incandescent Blank 12V AC/DC 12V LED D 24V AC/DC 24V 120V AC 120V (LED only) 240V AC 240V (LED only) www.IDEC.com R Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp/Lead Holder + Lamp + Lens = Complete Part Operators Style Signaling Lights *Full voltage units use a full voltage adaptor (TW-DA1B) instead of a transformer. Lamp holder is not included with operators, order separately. Lead holder is used when using 3 or more contact blocks. Order separately. Lamps Positions Description Part Number Maintained ASLW200 Spring return from right ASLW2100 Spring return from left ASLW2200 ASLW300-1 Maintained, cam 1 Maintained, cam 2 Maintained, cam 3 3 ASLW300-2 Spring return from left, cam 1 Spring return from left, cam 2 ASLW3200-1 Spring return from left/right, cam 1 Spring return from left/right, cam 2 ASLW3300-1 ASLW3100-2 ASLW3200-2 ASLW3300-2 Different cams produce different contact action. For details, see Contact Arrangements on page 669. Lenses (Knobs) ASLWLU-k 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y Contactors Part Number Part Number Timers ASLW3100-1 Knob Incandescent ASLW300-3 Spring return from right, cam 1 Spring return from right, cam 2 Style LED Voltage Relays & Sockets 2 Style Yellow LED not available. Use white LED In place of k, specify the lens color code from table. Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 667 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Illuminated Selector Switches (Sub-Assembled) continued Contact Blocks Style Standard Exposed Screw Fingersafe (IP20), CE marked Transformers/Full Voltage Modules Style Part Number 1NO 1NC HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Description Full Size Transformer Standard Fingersafe Part Number 120V AC TW-T126B 240V AC TW-T246B 480V AC TW-T486B 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Half Size Transformer 120V AC TW-T126SB 240V AC TW-T246SB Standard TW-DA1B Fingersafe TW-DA1FB Standard HW-DA1B Fingersafe HW-DA1FB Dummy Block Relays & Sockets TW-DB Full voltage model (use with even number of contacts) 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Lamp Circuit Components Style Application Part Number Short Lamp Holder Timers Used with a Half-size Transformer and one contact block Contactors Long Lamp Holder Full voltage model (use with odd number of contacts) TW-LH1 Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks TW-LH2 Used with TW-LH2 holder when using four contact blocks HW-LH3 All Transformers step down to 6V (use 6V lamp). Circuit Breakers Terminal Blocks Lead Holder 668 www.IDEC.com Switches & Pilot Devices o22mm - TW Series L How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Contact Arrangement Circuit Number Type and quantity of switch contacts * N/D = No designation required 1 Contact Block Mounting Position Operator Position Truth table indicates the operating position of contact block when operator is switched to that position. Position or mounting contact blocks on operator N/D 1NC 116 1NO 1NC 103 600 1NO-EM 1NC-LB 2NO N/D 2NC 104 2NO 2NC R 1 O X HW-C10 2 O O TW-DB 1 X O HW-C01 2 O O TW-DB 1 O X HW-C10 2 X O HW-C01 1 X O HW-C01 2 O X HW-C10 1 O X HW-C10R 2 X O HW-C01R 1 X O HW-C01R 2 O X HW-C10R 1 O X HW-C10 2 O X HW-C10 1 X O HW-C01 2 X O HW-C01 1 O X HW-C10 2 X O HW-C01 3 O X HW-C10 4 X O HW-C01 1 O X HW-C10 2 O X HW-C10 3 X O HW-C01 4 X O HW-C01 L R Spring Ret. from Rt. L R Spring Ret. from Lt. L Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 R Circuit Breakers 111 L Maintained Description Terminal Blocks N/D Contact Block Part Number Contactors 601 Operator Part Number Timers N/D Part number to use when ordering sub-assembly contact blocks, as required for use with corresponding mounting position Relays & Sockets 1NO Mounting Position Contact Block Part Number Signaling Lights Contact Circuit Number Operator Position 2 3 Contact Arrangement Chart: 2-Position Selector Switches Style 4 R Switches & Pilot Devices Contact Arrangement Charts 1. NO-EM, NC-LB = Early Make, Late Break. N/D = No circuit number designation required in assembled selector switch part number. 2. X = On (closed contacts) O = Off (Open contacts) 800-262-IDEC (4332) * USA & Canada 669 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Contact Arrangement Chart: 3-Position Selector Switches Style Operator Part Number Operator Position Contact Circuit Number Signaling Lights 202 203 1NO 1NC 302 Relays & Sockets 303 N/D 2NO 301 Timers 304 2NC N/D Contactors N/D 210 2NO 2NC Terminal Blocks 308 309 Circuit Breakers 310 Mounting Position Contact Block Part Number L C 1 X 0 0 HW-C10 2 X X O HW-C01 1 0 X X HW-C01 2 O 0 X HW-C10 1 X 0 X HW-C10 2 X X O HW-C01 1 0 X O HW-C01 2 O 0 X HW-C10 1 X 0 0 HW-C10 2 O 0 X HW-C10 1 X 0 X HW-C10 2 O 0 X HW-C10 1 0 X O HW-C01 2 X X O HW-C01 1 0 X X HW-C01 2 X X O HW-C01 1 X 0 0 HW-C10 2 0 0 X HW-C10 3 0 X X HW-C01 4 X X 0 HW-C01 1 0 X X HW-C01 2 0 0 X HW-C10 3 0 X X HW-C01 4 0 0 X HW-C10 R Description Maintained L 1 X 0 X HW-C10 2 X X 0 HW-C01 3 X 0 X HW-C10 4 X X O HW-C01 1 X 0 X HW-C10 2 X X 0 HW-C01 3 0 X O HW-C01 4 O 0 X HW-C10 1 0 X O HW-C01 2 O 0 X HW-C10 3 0 X O HW-C01 4 0 0 X HW-C10 C R Spring Return from Right L C R Spring Return from Left L C R Two-Way L C R Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 1. Each operator sub-assembly is available as a "-1" and a "-2" for 3-position selector switches. The internal cam of a "-1" is different from that of a "-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. 670 www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Contact Arrangement Chart: 3-Position Selector Switches Style Operator Part Number Operator Position Contact Circuit Number 4NO 305 4NC 314 C R Description Maintained L 1 X 0 0 HW-C10 2 0 0 X HW-C10 3 X 0 0 HW-C10 4 0 0 X HW-C10 1 X 0 X HW-C10 2 0 0 X HW-C10 3 X 0 X HW-C10 4 0 0 X HW-C10 1 0 X X HW-C01 2 X X 0 HW-C01 3 0 X X HW-C01 4 X X O HW-C01 1 0 X O HW-C01 2 X X 0 HW-C01 3 0 X O HW-C01 4 X X 0 HW-C01 C R L C R Spring Return from Left L C R Two-Way L C R Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Relays & Sockets N/D L Contact Block Part Number Signaling Lights N/D Mounting Position Spring Return from Right Timers 1. Each operator sub-assembly is available as a "-1" and a "-2" for 3-position selector switches. The internal cam of a "-1" is different from that of a "-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. Contactors Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 671 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Custom Selector Switch Building Guide To build a custom selector switch, follow these steps. Mounting Positions Step 1 L 4 2 How many positions of the switch are needed? # of positions (2, 3, 4, 5) Signaling Lights R 3 1 Step 2 How many contacts should there be? Relays & Sockets # of isolated contacts (maximum 6) Step 3 Fill in the Truth Table (X = closed, 0 = open) Knob Position 1 2 3 4 5 1 Contacts Timers 2 3 4 5 6 Contactors Step 4 If building a 2 position selector, skip this step. (2 position selectors have only one cam) If building a 3, 4, or 5 position selector, determine appropriate cam as follows: * Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page). * Repeat for all rows. The user must find one operator that contains all rows from above table. * Record the operator cam version. Circuit Breakers Terminal Blocks Step 5 Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. "L" and "R" refer to mounting on left or right side of operator as viewed from the front of the panel. Step 6 Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages 661 or 665. In place of the "Circuit Number" indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where "3" is the cam number, and contact arrangement "OELCXX" calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 possible mounting locations. Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance. 1. For Operator Truth Tables, see next page. 672 www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Operator Truth Tables Use the following tables to build custom selector switches. 4 Position Selector Switches 2 Position Selector Switches Contact ASW200 ASLW200 ASW2K00 HW-C01 (NC) HW-C10R (NO-EM) HW-C01R (NC-LB) Operator Position Left Right L O X R O X L X O R X O L O X R O X L X O R X O Contact Contact HW-C10 (NO) ASW300-1 ASW3K00-1 ASLW300-1 HW-C01 (NC) HW-C01R (NC-LB) Contact ASW300-2 ASW3K00-2 ASLW300-2 HW-C01 (NC) HW-C10R (NO-EM) HW-C01R (NC-LB) HW-C10 (NO) HW-C10R (NO-EM) HW-C01R (NC-LB) O O X O O HW-C01 (NC) L O X X X R X O X X HW-C10R (NO-EM) L X O O O R O X O O HW-C01R (NC-LB) L O X X X R X O X X Mounting Position 1 2 Center Right L X O O R O O X L O X X R X X O L X O O R O O X L O X X R X X O ASW400-1 Left Center Right L X O X R O O X L O X O R X X O L X O X R O O X L O X O R X X O Left Center Right L X O O R O O X L O X O R O X O L X O X R X O X L O X X R X X O 4 L X O O O R O O O X HW-C01 (NC) L O O X O R O X O O L X X O X R X O X X L O X X X R X X X O HW-C10R (NO-EM) 5 Position Selector Switches Contact HW-C10 (NO) ASW500 HW-C01 (NC) HW-C10R (NO-EM) HW-C01R (NC-LB) Contact Operator Position Mounting Position 3 HW-C10 (NO) HW-C01R (NC-LB) Operator Position Mounting Position Operator Position HW-C10 (NO) ASW500-1 800-262-IDEC (4332) * USA & Canada HW-C01 (NC) HW-C10R (NO-EM) HW-C01R (NC-LB) Operator Position Mounting Position 1 2 3 4 5 L X O O O O R O X O O O L O O X X X R O O O X X L X O O O O R O X O O O L O X X X X R X O X X X Operator Position Mounting Position 1 2 3 4 5 L X O O O O R O O O O X L O O O X O R O X O O O L X X X O X R X O X X X L O X X X X R X X X X O Circuit Breakers ASW300-3 ASW3K00-3 ASLW300-3 HW-C01 (NC) O Terminal Blocks Contact X O Contactors HW-C10 (NO) Left 4 Timers HW-C10R (NO-EM) Operator Position 3 L Contact Mounting Position 2 Relays & Sockets 3 Position Selector Switches Operator Position 1 R HW-C10 (NO) ASW400 Mounting Position Signaling Lights HW-C10 (NO) Mounting Position 673 Switches & Pilot Devices Nameplates -- TW Series Faceplates NWAL NWAQL 1.13" (29mm) o70mm 0.566" (14.5mm) 1.76" (45mm) 0.975" (25mm) 1.0" Signaling Lights Relays & Sockets Timers 1.76" (45mm) Part Number NWAL-OB (black) NWAL-OR (red) NWAQL-OB (black) NWAQL-OR (red) NWAS-OB NWAR-O Nameplate (engraved) NWAL-j NWAQL-j NWAS-j NWAR-27 1. In place of j, insert either the Standard Legend Code from table below or custom engraving delimited by " ". 2. Standard engravings are available at no charge. 3 NWAR-27 comes marked "Emergency Stop" as shown in drawing. Standard Legend Codes Legend AUTO CLOSE DOWN EMERG.STOP FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON Code 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 Legend OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP STOP TEST UP I (Int'l On) O (Int'l Off) EMO Pushbuttons/Selector Switches Code 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 Legend AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER Code 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 Legend REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN Selector Switches Code Legend Code 216 217 218 219 220 221 222 223 AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. To order engraved nameplates, add legend code to nameplate part number. Character height based on the number of characters and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. Nameplate Order Form on next page. Circuit Breakers Terminal Blocks EMERGENCY STOP Nameplate (blank) Pushbuttons Contactors NWAS 1.13" (29mm) (25.4mm) Switches & Pilot Devices o22mm - TW Series 674 www.IDEC.com Switches & Pilot Devices o22mm - TW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To ensure engraving accuracy, fax it to your IDEC representative. or Distributor. IDEC Rep/Distributor Contact:__________________________________ Your Name:__________________________________________ PO number (if known):__________________________________ Telephone:__________________________________________ IDEC Rep/Distributor Phone:__________________________________ Fax & Email:__________________________________________ IDEC Rep/Distributor Fax & Email:__________________________________ NWAL Engraving Location Step 1. Choose Letter Size - 7/64" or 1/8". 7/64" 11 characters max (for 7/64" size letters) 1/8" 9 characters max (for 1/8" size letters) Letter Size Letter Size Sample Letter Sizes Step 2. 7/64" Letters: Specify Quantity. Enter the number of nameplates desired in the box on the right. NWAQL 1/8" Letters: Qty 1 Step 1. Choose Letter Size - 7/64" or 1/8". 2 3 4 5 6 8 9 10 11 7/64" 11 characters max (for 7/64" size letters) 1/8" 9 characters max (for 1/8" size letters) Letter Size Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 9 characters. 7 Letter Size Sample Letter Sizes Step 2. 7/64" Letters: Specify Quantity. 1/8" Letters: Qty Step 1. Engraving Location A Choose Letter Size - 1/8" or 3/32". Engraving Location B Enter the number of nameplates desired in the box on the right. Enter the location of engraving (A or B), in the box on the right. 4 5 7 8 9 10 11 20 characters max (for 3/32" size letters) 1/8" 14 characters max (for 1/8" size letters) Letter Size Letter Size 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Sample Letter Sizes Specify Location. Qty 6 Circuit Breakers Step 3. Specify Quantity. 3 3/32" 1 Step 2. 2 Terminal Blocks Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 14 characters. 1 Contactors Enter the number of nameplates desired in the box on the right. NWAS Timers Engraving Location Relays & Sockets Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 9 characters. Signaling Lights Your Company Name:__________________________________________ Switches & Pilot Devices Custom Engraved Nameplates Order Form -- TW Series 3/32" Letters: Location 800-262-IDEC (4332) * USA & Canada 1/8" Letters: 675 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Switch Engraving Order Form - TW Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To ensure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: Telephone: Name: Fax: Address: Email: PO: Part Number to be Engraved: Please check one of the boxes below to indicate your choice of engraving options: Relays & Sockets o29mm, o40mm Mushroom Head Engraving Round Switch Square Switch Engraving Area 1 Area 2 # of Lines Letter Height Max. Characters Per Line 5/32 6 Timers 1 # of Lines Letter Height Max. Characters Per Line 5/32 5 1 1/8 6 5/32 6 2 1/8 6 5/32 5 2 5 3 1/8 6 4 3/32 5 Contactors 1/8 1. 2. 3. 4. 1/8 6 3 1/8 5 4 3/32 5 Terminal Blocks 1 Engraving Area 2 1 Above mentioned specifications hold true for standard size pushbuttons (round and square). Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters. Sample Letter Sizes 1/8 Letters: Line 1: 5/32 Letters: Line 2: Line 3: Line 4: Circuit Breakers Engraving Area 1 Enter text to be engraved: For IDEC Internal Use Only: Work Order #: 676 # of Lines www.IDEC.com Letter Height Max. Characters Per Line 5/32 5 1/8 5 5/32 7 1/8 7 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Accessories TW Series Accessories Item Appearance Description/Usage Part Number Contact Block Remover Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used to determine panel thickness adjustment. TW-KC1 Nut Locking Wrench Used in OR-14 locking wrench to tighten locking nuts inside square bezel TW-KQ2 Metal Bezel Chrome plated bezels tighten onto operator (replacement for damaged bezels) Plastic Bezel Black plastic bezels for square buttons (replacement for damaged bezels) Standard octagonal units (chrome-pl.) AW-R8 Full shroud octagonal units (chrome-pl.) AW-RF8 Full shroud mushroom head units O 40mm AW-G4 Round flush units (black plastic) AW-RP1B Round extended units (black plastic) AW-FP1B Square units (black plastic) AW-Q1B Square units with full shroud (black plastic) AW-QF1B Waterproof lens cover for square pilot lights APW00LN Waterproof lens cover for square illuminated buttons Boot/Cover APW00L Clear boot for round flush units OC-31 Clear boot for round extended units OC-32 *In place of asterisk, specify Rubber Boot color: B (black), G (green), R (red), Y (yellow) - (nitril rubber) OCW-11* Ring to prevent operator base from rotating in the mounting hole. Used when nameplate is not used OGL-31 Mounting Hole Plug Black rubber plug fills unused mounting holes in panel. OB-31 Metallic Mounting Hole Plug For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of 12 kfg-cm maximum Degree of protection: IP66 Replacement Keys Pair of keys (#0) LW9Z-BM Terminal Blocks TW-SK AKW2B-B Used on flush buttons to prevent inadvertent actuation 800-262-IDEC (4332) * USA & Canada Circuit Breakers Metal Button Guard Contactors Anti-Rotation Ring Replacement Black Sleeve for Keyswitch Timers Used to cover and protect pushbuttons OR-55 Relays & Sockets Rubber tool used to install or remove LED's and incandescent lamps Signaling Lights Lamp Removal Tool OLW-C 677 Switches & Pilot Devices Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - TW Series Item Appearance Description/Usage Part Number Terminal Tab Adaptor Quick- connect terminals #250 (17/64" x 3/64") single tab TW-FA1 Lock-out Adaptor Used to provide lock-out protection for pushbuttons and knob selector switches: * Up to O 40mm mushroom head size (Padlock not included.) Not applicable for e-stops. HW9Z-KL1 TW to TWTD Adaptor Used to mount TW series control unit (except square units) O 7/8" (22mm) into a O 1-13/64" (30mm) panel cut-out. TWN-A1R8 Replacement Marking Plates White plastic engraving plate for use on all illuminated units (included in each lens). May be used to capture printed mylar insert (not supplied by IDEC) under lens face. Round Pushbutton (O14mm) ALW2B Round Pilot Light (O 14mm) APW2B Mushroom Pushbutton (O 14mm) ALW3B Square Pilot Light (q 21mm) APQW1B Square Pushbutton (q 21mm) ALQW2B Fingersafe Covers for TW Series Description Used with 678 Part Number Fingersafe terminal cover, adds 6mm to overall depth APW and UPQW full voltage pilot lights APS-PVL Fingersafe terminal cover, adds 3.5mm to overall depth. One required for each contact, only for rearmost terminals Non-illuminated pushbuttons and selectors HW-VL2 Fingersafe terminal cover, adds 3mm to overall depth APW and UPQW transformer pilot lights, and illuminated pushbuttons and illuminated selectors HW-VL3 Fingersafe terminal cover for contacts. Full voltage illuminated pushbuttons and selectors HW-VL4 Fingersafe terminal cover for full voltage adaptor, adds 3 mm to depth Full voltage illuminated pushbuttons and selectors HW-VL5 Fingersafe terminal cover for half size transformer adaptor, adds 3 mm to depth Illuminated pushbuttons and selectors HW-VL6 Circuit Breakers Terminal Blocks Contactors Timers Appearance www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Dimensions Pushbuttons 37 30 30 47 M3.5 Terminal Screws 68.5 (3-4 blocks) 37 37 30 47 Panel Thickness 1 to 6 37 o40 48.5 (1-2 blocks) 25 25 Square Flush Panel Thickness 1 to 6 37 o40 M3.5 Terminal Screws 45 13 68.5 (3-4 blocks) 40mm Push-Pull Reset (unlock) 13 68.5 (3-4 blocks) 48.5 (1-2 blocks) 22.5 45 37 68.5 (3-4 blocks) Panel Thickness Reset 1 to 6 (unlock) Timers 48.5 (1-2 blocks) M3.5 Terminal Screws Reset Angle 75 o40 37 o29 Panel Thickness 1 to 6 Keylock Push On/Off 48.5 (1-2 blocks) 13 30 22.5 40mm Pushlock Key reset M3.5 Terminal Screws Panel Thickness 1 to 6 o29 M3.5 Terminal Screws 30 23 37 40mm Push-Lock-Turn-Reset Reset Angle 75 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) 68.5 (3-4 blocks) Relays & Sockets Panel Thickness 1 to 6 48.5 (1-2 blocks) 30 22.5 25 68.5 (3-4 blocks) 30 Panel Thickness 1 to 6 37 37 22.5 M3.5 Terminal Screw Panel Thickness 1 to 6 48.5 (1-2 blocks) 13 13 29mm Push-Lock-Turn-Reset M3.5 Terminal Screws Mushroom with Full Shroud o40 Panel Thickness 1 to 6 o29 48.5 (1-2 block) o24 40mm Mushroom M3.5 Terminal Screws 30 o46 29mm Mushroom 48.5 (1-2 blocks) 19.5 68.5 (3-4 blocks) 30 19 30 68.5 (3-4 blocks) Signaling Lights 30 Panel Thickness 1 to 6 37 o24 48.5 (1-2 blocks) 13 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) M3.5 Terminal Screws Panel Thickness 1 to 6 37 o29 o24 Panel Thickness 1 to 6 68.5 (3-4 blocks) M3.5 Terminal Screws Extended with Full Shroud M3.5 Terminal Screws o29 Extended M3.5 Terminal Screws o29 Flush 13 25 48.5 (1-2 blocks) 13 30 30.5 30 68.5 (3-4 blocks) Square Extended 37 Contactors 30 Panel Thickness 1 to 6 25 M3.5 Terminal Screws 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) 30 20 Selector Switches 48.5 (2 blocks) 13 25 30 68.5 (4 blocks) 13 25 30 48.5 (2 blocks) 68.5 (4 blocks) 37 o29 o24 37 37 o25 48.5 (2 blocks) 68.5 (4 blocks) Panel Thickness 1 to 6 Terminal Blocks o29 M3.5 Teminal Screws Panel Thickness 1 to 6 o29 M3.5 Terminal Screws Panel Thickness 1 to 6 o24 M3.5 Terminal Screws 13 19 41 30 Circuit Breakers 800-262-IDEC (4332) * USA & Canada 679 Switches & Pilot Devices Dimensions continued Illuminated Pushbuttons Extended with Full Shroud 25 37 o29 o24 37 o29 30 Panel Thickness 1 to 6 Reset Angle: 75 13 30 22.5 13 30 22.5 Marking plate: o13.9mm 21mm Panel Thickness 1 to 6 Reset Angle 75 o40 37 13 Marking plate: Mushroom 37 Panel Thickness 1 to 6 40mm Push-Turn-Reset o29 Marking plate: o15.5mm 29mm Push-Turn-Reset 30 20 Marking plate: o15.5mm 37 20 30 19 o29 Signaling Lights Panel Thickness 1 to 6 13 13 30 22.5 Marking plate: o13.9mm Marking plate: o13.9mm Push-Pull Panel Thickness 1 to 6 37 o40 Relays & Sockets Square Extended Panel Thickness 1 to 6 37 Panel Thickness 1 to 6 30 Extended o24 Switches & Pilot Devices o22mm - TW Series 13 25 30 30.5 Illuminated Selector Switches 1 Contact Block with Full Voltage Adaptor Transformer (2 blocks) X1 X1 Timers Marking plate: o13.9mm M3.5 Terminal Screws 1 Contact Block with Half Size Transformer Panel Thickness 1 to 6 X2 Panel Thickness 1 to 6 X1 X2 X2 Contactors 86.5 64.5 2 Contact Blocks with Full Voltage Adaptor Transformer (4 blocks) X1 M3.5 Terminal Screw Panel Thickness 1 to 6mm M3.5 Terminal Screws 2 Contact Blocks with Half Size Transformer Panel Thickness 1 to 6 X2 Panel Thickness 1 to 6 X1 X2 106.5 63.5 68.5 3 Contact Blocks with Full Voltage Adaptor 4 Contact Blocks with Full Voltage Adaptor 3 Contact Blocks with Half Size Transformer M3.5 Terminal Screws Panel Thickness 1 to 6 Panel Thickness 1 to 6 X1 X2 X2 X1 Terminal Blocks X2 X1 X1 Circuit Breakers X2 68.5 M3.5 Terminal Screws 84.5 680 www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Dimensions continued Pilot Lights Round Flush APW1 Transformer 28.5 30 Marking plate: o15.5 mm 28.5 66.5 25 37 30 37 37 Panel Thickness 1 to 6 28.5 66.5 22 mm Timers 25 Square Flush Marking Type APQW1B Transformer 30 Marking plate: 30 25 M3.5 Terminal Screw Panel Thickness 1 to 6 13 13 16 37 Square Flush Marking Type APQW1B Full Voltage o29 o23.6 37 30 25 13 Marking plate: o15.5 mm Panel Thickness 1 to 6 M3.5 Terminal Screw o29 o23.6 13 30 17 Dome APW2 Transformer Panel Thickness 1 to 6 16 13 Relays & Sockets 66.5 o29 o24 28.5 30 Dome APW2 Full Voltage 28.5 Panel Thickness 1 to 6 37 13 17 28.5 Round Flush Marking Type APW1B Transformer M3.5 Terminal Screw o29 o24 Panel Thickness 1 to 6 30 17 Signaling Lights Round Flush Marking Type APW1B Full Voltage 28.5 13 66.5 17 37 o24 37 13 30 28.5 Panel Thickness 1 to 6 M3.5 Terminal Screw o29 o24 Panel Thickness 1 to 6 o29 Round Flush APW1 Full Voltage 30 Marking plate: 22 mm A: 63.5 (2 blocks) 83.5 (4 blocks) 13 25 37 o29 Panel Thickness 1 to 6 o24 M3.5 Terminal Screws Contactors Illuminated Selector Switches 30 B: 86.5 (2 blocks), 106.5 (4 blocks) Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 681 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Dimensions continued Panel Cut-Out Diagram Dimension Part A A B C D Pushbuttons 1.17" (30mm) Std. Octagonal Pilot Light C Signaling Lights B 1.95" (50mm); 1.76" (45mm) minimum O 0.137" (3.5mm) Illuminated Pushbuttons > 1.56" (40mm) Large Mushroom O 0.878" (22.3mm) Selector Switches D 1.17" (30mm) *See note. Illuminated Selector Switches 1.The O 0.137" (O 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used. 2. *>1.404" (36mm) for 2- or 3-position. >1.95" (50mm) for 4- or 5-position. o22.5 0.8 15 18.5 1.6t Button installed 21 AW-RP1B Round Plastic Bezel Panel Thickness 0.8 to 3.2 o29 o29 2.2 Key hole o8 29.5 30 Waterproof Rubber Gasket 0.5t Finger-Safe Cover Dimensions HW-VL6 HW-VL5 HW-VL4 HW-VL3 HW-VL2 APS-PVL Circuit Breakers Terminal Blocks 30 o2 Contactors 70 30 13 93 6.5 R6 AW-QF1B Square Full Shroud 24 (inside) 0 o5 4.4) 4 :o (ID 682 3.5 3.5 AW-FP1B Round Plastic w/Full Shroud 19.8 82.5 o25 Button installed 13 Timers o29 Extended Flush HW9Z-KL1 Lock-out Adaptor 9 o31 .5 M22 P1.0 OB-31 Mounting Hole Rubber Plug o26 R42 o32 Mounting Centers 50 min. o27.4 9 M22 P1.0 18.6 o22 OCW-11 Pushbutton Rubber Boot o32 OLW-C Metal Button Guard o31 OGL-31 Anti-Rotation Ring 10.2 Relays & Sockets Accessory Dimensions www.IDEC.com Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Component Construction and General Instructions -- TW Series Instructions for Switches and Pilot Devices TW Series: Adjustment for Panel Thickness The panel thickness ring provides adjustment from 0.04" to 0.24" (1 to 6mm) in 0.004" (0.1mm) increments. Rotate the ring until the markings around the periphery are aligned for the desired thickness, as shown below. Signaling Lights Scale on Adjustment (in 0.1 mm) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0 0.1 mm 1 2 3 4 5 1 mm Panel Thickness Scale (in 1 mm on the operator) 6 A 3 5 4 6 Ex. Panel thickness 2.6 mm Ex. Panel thickness 2 mm Note: When a nameplate or an anti-rotation ring is used, add 0.03" (0.8mm) to the panel thickness dimension. An adjustment for panel thicknesses shown below can be made quickly by using the contact block remover tool. Tool TW-KC1 1.6 mm Relays & Sockets 2 4 6 3 5 2.3 mm 3.5 mm Timers 1 mm 2 mm 3.2 mm Contactors Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 683 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Instructions continued Pilot Lights and Pushbuttons IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up. Octagonal and Round Bezels Octagonal and round bezels screw into the operator. Use a locking ring wrench (optional) for secure tightening and easy removal. Round flush and extended buttons snap onto the operator base. Mushroom buttons screw onto the operator base. Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Round Marking Unit Lens Relays & Sockets Insert marking plate under lens Press in round flush and extended lens. Screw in mushroom lens Marking Plate Press in Square Bezels Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally, install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base. Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on. Insert Insert marking plate under lens Marking Plate Insert marking plate under lens Square Lens Press in Illuminated Pushbutton Pilot Light Square Lens Timers Square Marking Units Marking Plate Lens Retainer To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16" screwdriver into one of the recesses. Terminal Blocks Contactors Waterproof Lens Marking Plate Engraving Area Circuit Breakers Shape Round Engraving Area Used With Part Number O 0.55" (14mm) Illuminated pushbuttons ALW2B O 0.55" (14mm) Pilot lights APW2B Mushroom O 0.55" (14mm) Illuminated mushroom Square q 0.83" (21mm) Square pilot lights APQW1B Square q 0.83" (21mm) Square illuminated pushbuttons ALQW2B 684 ALW3B www.IDEC.com Switches & Pilot Devices o22mm - TW Series Selector Switches The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the handle and then press handle into the operator, as shown below. Recess Press in color insert Signaling Lights Press in handle Illuminated Selector Switch Remove color insert before pulling out the handle. Selector Switch (non-illuminated) 3-Postion, 45 4-Postion, 45 0 1 2 1 1 2 2 3 4 Relays & Sockets Standard Operating Positions 2-Postion, 90 Switches & Pilot Devices Instructions, continued 5-Postion, 30 1 2 3 4 5 Positions: Non-Illuminated 3-Position Operators 1 0 1 2 1 0 0 2 Timers 2 Installation TW Pilot Lights Terminal X1 = Positive Terminal X2 = Negative Contactors Make sure slot is facing up TW Illuminated Pushbuttons, TW Selector Switches (AC Transformer or Full Voltage) Terminal Blocks Lamp holder is installed as shown, due to polarity. Lead holder (used with two stacks of contact blocks ) does not have polarity. Installation of LED Illuminated Units AC transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode with DC power supply to protect against surges and noise.) LED Terminal X2 Circuit Breakers Ter minal X1 Diode Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. 800-262-IDEC (4332) * USA & Canada 685