RSP-750 750W Power Supply with Single Output series Dimension L * W * H 250 * 127 * 41 (1U) 9.84 * * 1.61 (1U) 5 mm inch Bauar t gepruft Sicherheit egel ma ge od o s be wac g R33100 RoHS CNS14336-1 www. tuv.com ID 2000000000 UL62368-1 EN62368-1 GB4943.1 TPTC004 IEC62368-1 Features Universal AC input / Full range Built-in active PFC function High efficiency up to 92% Forced air cooling by built-in DC fan Output voltage and constant current level programmable Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal Protections: Short circuit / Overload / Over voltage Applications Factory control or automation apparatus Test and measurement instrument Laser related machine Burn-in facility RF application / Over temperature Optional conformal coating 5 years warranty Description RSP-750 is a 750W single output enclosed type AC/DC power supply. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70. Moreover, RSP-750 provides vast design flexibility by equipping various built-in functions such as the output programming, remote ON-OFF control, auxiliary power, etc. Model Encoding / Order Information RSP - 750 - 48 Output voltage (5V/12V/15V/24V/27V/48V) Output wattage Series name File Name:RSP-750-SPEC 2019-07-29 RSP-750 750W Power Supply with Single Output series SPECIFICATION MODEL RSP-750-5 RSP-750-12 RSP-750-15 RSP-750-24 RSP-750-27 RSP-750-48 DC VOLTAGE 5V 12V 15V 24V 27V 48V RATED CURRENT 100A 62.5A 50A 31.3A 27.8A 15.7A CURRENT RANGE 0 ~ 100A 0 ~ 62.5A 0 ~ 50A 0 ~ 31.3A 0 ~ 27.8A 0 ~ 15.7A RATED POWER 500W 750W 750W 751.2W 750.6W 753.6W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p RIPPLE & NOISE (max.) Note.2 150mVp-p OUTPUT 10 ~ 13.5V 13.5 ~ 16.5V 20 ~ 26.4V 24 ~ 30V 43 ~ 55V VOLTAGE TOLERANCE Note.3 2.0% 4.75 ~ 5.5V 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms at full load 90.5% 90.5% 92% VOLTAGE ADJ. RANGE 16ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT 16ms/115VAC at full load Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.97/230VAC EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 82% 5V : 5.6A/115VAC 2.8A/230VAC 25A/115VAC 40A/230VAC LEAKAGE CURRENT <2.0mA / 240VAC 0.98/115VAC at full load 87% 89% 12V~48V : 8.2A/115VAC 3.9A/230VAC 105 ~ 125% rated output power OVERLOAD PROTECTION OVER VOLTAGE (OVP) Protection type : Constant current limiting, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V 56.6 ~ 66.2V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE OUTPUT VOLTAGE PROGRAMMABLE(PV) Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual. CONSTANT CURRENT LEVEL PROGRAMMABLE(PC) Adjustment of constant current level is allowable to 40 ~ 110% of rated current. Please refer to the Function Manual. 12V @ 0.1A ; tolerance : 10% FUNCTION AUXILIARY POWER REMOTE ON-OFF CONTROL Power on : short between Remote ON-OFF(pin13) & 12V-AUX(pin14) on CN50 Power off : open between Remote ON-OFF(pin13) & 12-AUX(pin14) on CN50 DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE The TTL signal out, power supply turn on = 0 ~ 1V ; power supply turn off = 3.3 ~ 5.6V -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing 0.03%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL62368-1, TUV EN62368-1 , EAC TP TC 004, CCC GB4943.1 , BSMI CNS14336-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Conducted Test Level / Note EN55032 (CISPR32) / EN55011 (CISPR11) Class B Radiated EN55032 (CISPR32) / EN55011 (CISPR11) Class B Harmonic Current EN61000-3-2 ----- SAFETY & Voltage Flicker EN61000-3-3 ----- EMC EN55024 , EN61204-3, EN61000-6-2, CCC GB17625.1,GB/T9254, BSMI CNS13438 EMC EMISSION (Note 7) EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Parameter Standard Test Level / Note ESD EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact Radiated EN61000-4-3 Level 3 EFT / Burst EN61000-4-4 Level 3 Surge EN61000-4-5 Conducted EN61000-4-6 Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line Level 3 Magnetic Field EN61000-4-8 Level 4 Voltage Dips and Interruptions EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods 336.9K hrs min. Telcordia SR-332 (Bellcore) ; 109.1K hrs min. 250*127*41mm (L*W*H) 1.64Kg; 6pcs/10.8Kg/1.1CUFT MIL-HDBK-217F (25) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. There is high possibility to trigger the floating over voltage protection when PV voltage is trimmed from a high voltage level to a lower voltage level at light load or no load condition. It is suggested that turn off the power supply and set PV voltage to the lowest level, then adjust output voltage to a desired value. 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-750-5) 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:RSP-750-SPEC 2019-07-29 RSP-750 750W Single Output Power Supply series Block Diagram PFC fosc : 90KHz PWM fosc : 70KHz +S ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & PFC RECTIFIERS & FILTER POWER SWITCHING +V -V -S O.L.P. PFC CONTROL DETECTION CIRCUIT PWM CONTROL DC OK PV/PC O.V.P. RECTIFIERS CONTROL ON/OFF FAN AUX POWER REMOTE ON-OFF AUX POWER(12V/0.1A) RECTIFIERS & FILTER AUX GND Static Characteristics 100 INPUT MODEL 90 100~264VAC 80 LOAD (%) 70 90VAC 60 INPUT 50 40 MODEL 100~264VAC 90 95 100 115 264 90VAC INPUT VOLTAGE (VAC) 60Hz 12V 15V 500W 750W 750W 100A 62.5A 50A 450W 675W 675W 90A 56.25A 45A 24V 27V 48V 751.2W 750.6W 753.6W 31.3A 27.8A 15.7A 676.08W 675.54W 678.24W 28.17A 25.02A 14.13A 5V Efficiency vs Load (48V Model) Derating Curve 95 100 EFFICIENCY (%) 90 80 LOAD (%) 60 50 40 85 230V 80 75 20 70 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD The curve above is measured at 230VAC. File Name:RSP-750-SPEC 2019-07-29 RSP-750 750W Single Output Power Supply series Function Manual 1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. 1 CN50 PIN3 -S +S -S +VS -VS 2 4 5 2 +V 13 CN50 7 PV PS 6 13 PC DC_OK GND REMOTE ON-OFF TB1 1 -V LOAD + 3 PO GND G-AUX 12V-AUX 8 14 14 PIN1 +S Fig 1.1 The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal. By factory default, on CN50 , Remote ON-OFF (pin13) and 12V-AUX (pin14), PV (pin5) and PS (pin6), and PC (pin7) and PO (pin8, respectively, are shorted when shipped. The power supply will have no output if the shorting connector is not assembled unless certain functin needs to be activated. 2.Remote ON-OFF The power supply can be turned ON/OFF by using the "Remote ON-OFF" function. CN50 1 CN50 TB1 1 2 +V 5 7 13 +S -S PV REMOTE PC DC_OK GND ON-OFF +VS -VS PS PO 13 2 -V LOAD + 3 4 6 SW GND G-AUX 12V-AUX 14 8 14 Fig 2.1 Between Remote ON-OFF(pin13) and 12V-AUX(pin14) Power Supply Status SW close (Short) ON SW open (Open) OFF When multiple power supplies need to turn ON/OFF simultaneously by Remote ON-OFF control, -S & -V on CN50, as well as +S & +V, on each power supply should be connected. File Name:RSP-750-SPEC 2019-07-29 RSP-750 750W Single Output Power Supply series 3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~110% of the nominal voltage by applying EXTERNAL VOLTAGE. Vout 120%(Typ.) OUTPUT VOLTAGE (%) Nominal Vout 120 110 100 External Voltage (2~5.5VDC) 80 Non-Linear 1 60 3 5 7 11 13 +S -S PV PC DC_OK GND REMOTE ON-OFF +VS -VS PS PO 40 20 CN50 GND G-AUX 12V-AUX UVP 10%(Typ.) 2 1 2 3 4 4 8 14 5 5.5 6 EXTERNAL VOLTAGE (VDC) Fig 3.1 If EXTERNAL VOLTAGE (VDC) <0.5V,the power supply may enter under voltage protection; it needs to be restarted to work. Caution: By factory default, the Output Voltage Programming is not activated, and PV (pin5) and PS(pin6) are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections' diagrams, please keep PV (pin5) and PS(pin6) shorted ; other wise, the power supply will have no output. 4. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim) The constant current level can be trimmed to 40~110% of the rated current by applying EXTERNAL VOLTAGE. Io 115%(Typ.) CONSTANT CURRENT LEVEL (%) Rated Current 120 110 100 External Voltage (2~5.5VDC) 80 1 Non-Linear 3 +S 60 +VS 40 2 5 -S -VS 4 7 PV PS CN50 11 13 PC DC_OK GND REMOTE ON-OFF PO GND G-AUX 12V-AUX 14 6 20 1 2 3 4 5 5.5 6 EXTERNAL VOLTAGE (VDC) Fig 4.1 Caution: By factory default, the Output Current Programming is not activated, and PC(pin7) and PO(pin8) are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections' diagrams, please keep PC(pin7) and PO(pin8) shorted ; otherwise, the power supply will have no output. CN50 -V LOAD + +V TB1 1 13 2 14 File Name:RSP-750-SPEC 2019-07-29 RSP-750 750W Single Output Power Supply series 5.DC_OK signal "DC_OK" is an open collector signal. It indicates the output status of the power supply. It can operate in two ways : One is sinking current from external TTL signal ; the other is sending out a TTL voltage signal. Sinking current from external TTL signal: The maximum sink current is 10mA and the maximum external voltage is 5.6V. Sending out TTL voltage signal : Between DC- OK(pin9) and GND(pin10&11) Output Status 0 ~ 1V Power supply ON 3.3 ~ 5.6V Power supply OFF CN50 1 CN50 -V LOAD + +V TB1 1 13 2 14 3 5 7 9 11 13 +S -S PV PC DC_OK GND REMOTE ON-OFF +VS -VS PS PO 2 4 6 8 GND G-AUX 12V-AUX 14 Fig 5.1 File Name:RSP-750-SPEC 2019-07-29 RSP-750 750W Single Output Power Supply Mechanical Specification Case No.212A series Unit:mm 236 20.5 7.8 6 25.4 1 3-M4 L=6 1 1 250 231.5 41 18.5 33.5 63.5 2-M5 -V 2 CN50 1 14 13 3 2 1 10 7 SVR51 2 Air flow direction 90 127 +V TB1 2 3-M4 L=4 2 1 1 20.5 25.4 3-M4 L=6 236 Mounting Instruction 7.8 1 6 Chassis of RSP-750 Mounting Surface Hole No. Recommended Screw Size 1 M4 2 M4 MAX. Penetration Depth L 6mm 4mm Recommended mounting torque 7~11Kgf-cm 7~11Kgf-cm Mounting Screw Control Pin No. Assignment (CN50) : HRS DF11-14DP-2DS or equivalent 1 13 2 Mating Housing HRS DF11-14DS or equivalent Terminal HRS DF11-**SC or equivalent L 14 Pin No. Function Description 1 +S Positive sensing for remote sense. 2 +VS +V Signal. The +VS should be connected to the +S to reduce the noise when "output voltage programming" function is in use. 3 -S Negative sensing for remote sense. 4 -VS -V Signal. The -VS should be connected to the -S to reduce the noise when "output voltage programming" function is in use. Connect to external DC voltage source for output voltage programming, referenced to pin 10,11 (GND). PV 5 6 PS Reference pin regarding output voltage programming. Please refer to the Function Manual. 7 PC Connect to external DC voltage source for output current programming. 8 PO Reference pin regarding output current programming. Please refer to the Function Manual. Open collector signal, referenced to pin10,11(GND). Low when PSU turns on. 9 DC_OK The maximum sink current is 10mA and the maximum external voltage is 5.6V. 10,11 12 GND These pins connect to the negative terminal (-V). Return for DC_OK Signal output. Auxiliary voltage output ground. G-AUX The signal return is isolated from the output terminals (+V & -V). 13 REMOTE Turns the output on and off by electrical or dry contact between pin 13 ( ON/OFF) and pin 14 (12V-AUX). ON-OFF Short: Power ON, Open: Power OFF. 14 Auxiliary voltage output, 10.8~13.2V, referenced to pin 12(G-AUX). 12V-AUX The maximum load current is 0.1A. This output is not controlled by the "remote ON/OFF control". File Name:RSP-750-SPEC 2019-07-29 750W Single Output Power Supply RSP-750 series AC Input Terminal Pin No. Assignment Pin No. 1 2 3 Assignment AC/N AC/L FG Diagram Maximum mounting torque 18Kgf-cm DC Output Terminal Pin No. Assignment Assignment Diagram +V, -V Maximum mounting torque 10Kgf-cm Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:RSP-750-SPEC 2019-07-29