Example: PPTR1000AP2VB
PPTR Precision Pressure Transducer - Ruggedized
FULL SCALE PRESSURE RANGE
Absolute Gauge
0010 n/a 10 PSI
0015 15 PSI n/a
0020 20 PSI 20 PSI
0040 40 PSI 40 PSI
0100 100 PSI 100 PSI
0300 300 PSI 300 PSI
0500 500 PSI 500 PSI
1000 1000 PSI 1000 PSI
1500 1500 PSI 1500 PSI
3000 3000 PSI 3000 PSI
Type P1 Pressure P2 Pressure
A Absolute
0 (vacuum) to FS N/A
G Gauge
Reference to FS Reference
P1 PRESSURE CONNECTION
P 1/4 - 18 NPT (internal)
OUTPUTS
2V RS-232 digital, 0-5V analog
5V RS-485 digital, 0-5V analog
ELECTRICAL CONFIGURATION AND CONNECTION
B 6-pin connector (4)
D 1/2 - 14 NPT external w/ 4ft pigtail cable
OPTIONS
A Demonstration Kit
B Mating Connector - for 6-pin connector version
C Power Supply/Data Cable - for 6-pin connector version
D Hastelloy Diaphragm
PPTR 1000 A P 2V B - A
Honeywell reserves the right to make changes to any products or technology herein
to improve reliability, function or design. Honeywell does not assume any liability
arising out of the application or use of any product or circuit described herein;
neither does it convey any license under its patent rights nor the rights of others.
Covered by one or more of the following US Patents: 4,918,992; 4,788,521; and
5,948,988.
PPTR SENSOR PRODUCTS
Solid State Electronics Center
12001 State Highway 55
Plymouth, MN 55441
1-800-323-8295
E-Mail: ssec.customer.service@honeywell.com
Web Site: www.ssec.honeywell.com
ORDERING INFORMATION
SPECIFICATIONS
Performance Specifications(1)
Accuracy: (from -40 to 85°C)
Digital: ± 0.10% FS Typ., ± 0.20% FS Max.
Analog: ± 0.12% FS Typ., ± 0.24% FS Max.
Temperature: ± 1°C (at sensing element)
Temperature Range:
Operating: -40 to 85°C (-40 to 185°F)
Storage: -55 to 90°C (-67 to 194°F)
Sample Rate: 8.33ms to 51.2min
Update Rate: 8.33ms to 12s
Resolution:
Digital: Up to 10 PPM
Analog: 1.22mV steps (12 bits)
Response Delay:
(1000/update rate) + 1ms, maximum 17ms
Mechanical Specifications
Pressure Ranges and Type:
See ordering information.
Media Compatibility:
Suitable for media compatible with 316
stainless steel.
Hastello
dia
hra
m o
tion
Weight: 14 oz. (397gm) 6-pin connector
22 oz. (624gm) NPT w/pigtail style
Electrical Specifications
Power Requirements:
Supply Voltage: 6.0 to 30 VDC
Operating Current: 19-27mA
Standby Current: 11mA
Analog Output:
Voltage Range: 0-5 V (User adjustable)
Environmental Features
(2)(3)
Overpressure: 3x FS, maximum 6000 psi
Burst Pressure: 3x FS, maximum 8500psi
Mechanical Shock: 1500g, 0.5ms half sine
Temp Shock: 24 1-hr cycles, -40 to 85°C
Vibration: 0.5in or 20G’s, 20 Hz - 2K Hz
CASE OUTLINES
(1) Accuracy is the sum of worst case linearity, repeatabil-
ity, hysteresis, thermal effects and calibration errors from
-40 to 85°C. Typical is the average of absolute value of
errors at all pressures and temperatures.
(2) Exposure to overpressure will not permanently affect
calibration or accuracy of unit. Burst pressure is the sum
of the measured pressure plus the static pressure and
exceeding it may result in media escape. Mechanical
Shock tested per MIL-STD-883D, M2002.3, Cond B.
Vibration tested per MIL-STD-883D, M2007.2, Cond A.
(3) CE Mark tested per EN50081-2, EN50082-2.
(4) Connector Mil-C-26482, Shell Size #10, 6-pin #20 size.
900132 9/00